EMC AX-Series Navisphere SP Agent Version 6.20.0.3.12 for FLARE OE 02.20.yyy Release Notes P/N 300-003-516 REV A01 February 23, 2006 These release notes contain supplemental information about EMC® Navisphere® SP Agent for AX-series storage systems that have been upgraded from Navisphere Express to Navisphere Manager. Topics include: Product description ................................................................................... 2 New features and changes........................................................................ 2 Environment and system requirements.................................................. 2 Fixed problems ........................................................................................... 2 Known problems and limitations ............................................................ 3 Technical notes ........................................................................................... 4 Documentation ........................................................................................... 5 Software media, organization, and files ................................................. 6 Installation .................................................................................................. 6 Troubleshooting and getting help ........................................................... 7 1 Product description Product description The EMC Navisphere Storage Processor (SP) Agent is storage-system software that allows a Navisphere client application (such as Navisphere Manager or Navisphere CLI) to communicate with FLARE™ software in an AX-series storage system. The SP Agent is an application with no direct user interface. You configure and control the SP Agent through the Remote Agent Configuration feature of Navisphere Manager and CLI. Several Navisphere clients can communicate with one Navisphere SP Agent running on one SP in a storage system. New features and changes This section describes any new features - enhancements to existing functionality or added functionality - and changes for this release of the product. Support for AX150-series storage systems Environment and system requirements This section identifies the hardware and software requirements for proper operation of this release of the SP Agent. Hardware The minimum hardware requirement is an AX150-series storage system. FLARE software FLARE Operating Environment (OE) version 02.20.yyy is required for AX150-series storage systems. Navisphere management software requirements Navisphere Manager version 6.20.xx.xx.xx is required for the AX150series storage systems. Fixed problems Visit the EMC Powerlink™ Issue Tracker website at http://Powerlink.EMC.com for the most recent updates and information on previous Navisphere SP Agent releases. 2 EMC AX-Series Navisphere SP Agent Release Notes Known problems and limitations Known problems and limitations Visit the EMC Powerlink Issue Tracker website at http://Powerlink.EMC.com for the most recent updates and information on previous Navisphere SP Agent releases. Problem area and description Work-around NDU failure due to problems writing to the event log. The The primary SP for the NDU must be rebooted. agent logs an event in the application log if it encounters an error when trying to write to the Event Monitor Log. The error logged in the application log is EM_EventLog::WriteLog - Error Writing Event. The agent then terminates and as a result the NDU fails. [116046] You cannot not create an incremental copy session with a source LUN that is currently active. [109454] Wait until the active session completes and try again. The loopback address that a client uses is equivalent to the local hostname or IP address, independent of any "-a" options used when invoking the agent. None. When a hot spare is replaced with another drive of same or larger capacity, the new drive's properties should be displayed in the hot spare properties. Instead the old drive's properties are displayed.[125157] None. If you have an off-array CIMOM on the same management The user has to stop the NaviGovernor and restart it to station as the central agent and you stop the agent to add make the CIMOM aware of the changes in the user the user privileges into the agent.config file and restart it, privileges. the off-array CIMOM will not know about the new user entries you just added. [127726] While you try to install a software update with CLI you see This is a result of a transient network condition. Try the operation again. the following error: Error: NDU command failed Error returned from Agent User connect attempt timed out. An inspection of the logs indicates the agent logged the following message: Agent Closing Log File -- Too many consecutive exception events. To prevent an overflow of messages in the application event logs, the logging is turned off and no further events are logged until the socket is reset again and the agent is communicating. The agent is still up and can be connected to once the socket gets reset. [127776] EMC AX-Series Navisphere SP Agent Release Notes 3 Technical notes Technical notes This section includes important information that does not appear anywhere else. Software upgrades For an AX-series storage system, the SP Agent is an integral part of the AX-series storage-system software – called the FLARE Integrated Operating Environment software. An upgrade to the SP Agent is available only as a new version of the AX-Series FLARE Integrated Operating Environment software. Polling of FLARE The SP Agent is in degraded mode when a poll (a get operation) of FLARE returns any error. When a set operation, such as binding a LUN, returns an error, the SP Agent does not go to degraded mode. When the AX-series SP Agent is in degraded mode, Navisphere Manager displays an ‘F’ on the storage system icon, and the following message appears in the Event Log: INTERNAL: Poll failure: agent going into degraded mode: 4 EMC AX-Series Navisphere SP Agent Release Notes Documentation In this situation, only the following functions are guaranteed to work: Retrieval of event log messages File Transfer Manager functionality of the SP Agent Software installation (only if the SP software allows it) Rebooting the SP (for peer or both SPs) Documentation The following table lists the documents with information on reinstalling and configuring the SP Agent: Part Number Description 069001125 EMC Navisphere Manager Administrator's Guide 069001038 EMC Navisphere Command Line Interface (CLI) Reference 300-002-827 EMC AX100-Series Integrated Management Software Version 02.19.100.5.yyy Release Notes 300-003-021 EMC AX150-Series Integrated Management Software version 02.20.150.5.yyy Release Notes These manuals can be found on the EMC Navisphere Manager Upgrade Documentation CD that shipped with the Navisphere Manager upgrade kit or on the AX100-series or AX150-series support website. EMC AX-Series Navisphere SP Agent Release Notes 5 Software media, organization, and files Software media, organization, and files The following table lists the applicable documentation media for this release: Part Number Description 053-001-477 For AX100-series storage systems - EMC CLARiiON Storage-System Hardware and Software Documentation CD 053-001-516 For AX150-series storage systems - EMC Navisphere Manager Upgrade Documentation CD Installation AX-series storage systems ship from the factory with the latest version of the SP Agent installed on each SP. Since the SP Agent is an integral part of the FLARE Integrated Operating Environment on an AX-series storage system, updates to the SP Agent are integral parts of this FLARE software. To update the FLARE Integrated Operating Environment, use the software installation procedure in the EMC Navisphere Manager Administrator's Guide or the EMC Navisphere Command Line Interface (CLI) Reference. 6 EMC AX-Series Navisphere SP Agent Release Notes Troubleshooting and getting help Troubleshooting and getting help This section provides specific instructions for contacting EMC Customer Support and obtaining additional information about EMC products. Where to get help EMC support, product, and licensing information can be obtained as follows. Product information For documentation, release notes, software updates, or for information about EMC products, licensing, and service, go to the EMC Powerlink website (registration required) at: http://Powerlink.EMC.com Technical support For technical support, go to EMC WebSupport on Powerlink. To open a case on EMC WebSupport, you must be a WebSupport customer. Information about your site configuration and the circumstances under which the problem occurred is required. EMC AX-Series Navisphere SP Agent Release Notes 7 Troubleshooting and getting help Copyright © 2006 EMC Corporation. All Rights Reserved. EMC believes the information in this publication is accurate as of its publication date. However, the information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. All other trademarks used herein are the property of their respective owners. 8 EMC AX-Series Navisphere SP Agent Release Notes
© Copyright 2026 Paperzz