Text for tenders CONTOIL® VZOA 15...50 VZOA ... RC 130/16 92286 Threaded connection VZOA 15 RC 130/16 CONTOIL® Oil meter VZOA 15 RC 130/16 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm With threaded ends 3/4” (for couplings 1/2”) Nominal pressure: PN 16 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l 92287 VZOA 15 RC 130/16-RV0,1 CONTOIL® Oil meter VZOA 15 RC 130/16-RV 0.1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm With threaded ends 3/4” (for couplings 1/2”) Nominal pressure: PN 16 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92288 integrated in register 48 V AC/DC, 50 mA, 2 0.1 l VZOA 15 RC 130/16-RV1 CONTOIL® Oil meter VZOA 15 RC 130/16-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm With threaded ends 3/4” (for couplings 1/2”) Nominal pressure: PN 16 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h 81900602 09.2010 1/17 Text for tenders 92289 Max. measuring deviation: value Repeatability: Smallest readable value: Registration capacity: ± 0.5% of measured With RV Reed pulser unit Contact load max.: W Pulse value: integrated in register ± 0.1% 0.01 l 1 Mio l 48 V AC/DC, 50 mA, 2 1l VZOA 15 RC 130/16-IN0,01 CONTOIL® Oil meter VZOA 15 RC 130/16-IN 0.01 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm With threaded ends 3/4” (for couplings 1/2”) Nominal pressure: PN 16 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.01 l 92290 VZOA 20 RC 130/16 CONTOIL® Oil meter VZOA 20 RC 130/16 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 20 mm With threaded ends 1” (for couplings 3/4”) Nominal pressure: PN 16 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 30...1500 l/h Max. continuous flow Qn: 1000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l 92291 VZOA 20 RC 130/16-RV1 CONTOIL® Oil meter VZOA 20 RC 130/16-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: With threaded ends 1” 81900602 DN 20 mm (for couplings 3/4”) 09.2010 2/17 Text for tenders Nominal pressure: PN 16 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 30...1500 l/h Max. continuous flow Qn: 1000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92292 integrated in register 48 V AC/DC, 50 mA, 2 1l VZOA 20 RC 130/16-IN0,01 CONTOIL® Oil meter VZOA 20 RC 130/16-IN 0.01 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 20 mm With threaded ends 1” (for couplings 3/4”) Nominal pressure: PN 16 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 30...1500 l/h Max. continuous flow Qn: 1000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.01 l 92293 VZOA 25 RC 130/16 CONTOIL® Oil meter VZOA 25 RC 130/16 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 25 mm With threaded ends 1 1/4” (for couplings 1”) Nominal pressure: PN 16 bar Installation length: 190 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 75...3000 l/h Max. continuous flow Qn: 2000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l 81900602 09.2010 3/17 Text for tenders 92294 VZOA 25 RC 130/16-RV1 CONTOIL® Oil meter VZOA 25 RC 130/16-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 25 mm With threaded ends 1 1/4” (for couplings 1”) Nominal pressure: PN 16 bar Installation length: 190 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 75...3000 l/h Max. continuous flow Qn: 2000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92295 integrated in register 48 V AC/DC, 50 mA, 2 1l VZOA 25 RC 130/16-IN0,1 CONTOIL® Oil meter VZOA 25 RC 130/16-IN 0.1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 25 mm With threaded ends 1 1/4” (for couplings 1”) Nominal pressure: PN 16 bar Installation length: 190 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 75...3000 l/h Max. continuous flow Qn: 2000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.1 l 92296 VZOA 40 RC130/16 CONTOIL® Oil meter VZOA 40 RC 130/16 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 40 mm With threaded ends 2” (for couplings 1 1/2”) Nominal pressure: PN 16 bar Installation length: 300 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 225...9000 l/h 81900602 09.2010 4/17 Text for tenders Max. continuous flow Qn: Max. measuring deviation: value Repeatability: Smallest readable value: Registration capacity: 92297 6000 l/h ± 0.5% of measured ± 0.1% 0.1 l 10 Mio l VZOA 40 RC 130/16-RV1 CONTOIL® Oil meter VZOA 40 RC 130/16-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 40 mm With threaded ends 2” (for couplings 1 1/2”) Nominal pressure: PN 16 bar Installation length: 300 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 225...9000 l/h Max. continuous flow Qn: 6000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92298 integrated in register 48 V AC/DC, 50 mA, 2 1l VZOA 40 RC 130/16-IN0,1 CONTOIL® Oil meter VZOA 40 RC 130/16-IN 0.1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 40 mm With threaded ends 2” (for couplings 1 1/2”) Nominal pressure: PN 16 bar Installation length: 300 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 225...9000 l/h Max. continuous flow Qn: 6000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.1 l VZOA Flange 130/25 92299 Flange connection VZOA 15 FL 130/25 CONTOIL® Oil meter VZOA 15 FL 130/25 81900602 09.2010 5/17 Text for tenders Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm Connection for flanges: DN 15 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l 92300 VZOA 15 FL 130/25-RV0,1 CONTOIL® Oil meter VZOA 15 FL 130/25-RV 0.1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm Connection for flanges: DN 15 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92301 integrated in register 48 V AC/DC, 50 mA, 2 0.1 l VZOA 15 FL 130/25-RV1 CONTOIL® Oil meter VZOA 15 FL 130/25-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm Connection for flanges: DN 15 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l With RV Reed pulser 81900602 integrated in register 09.2010 6/17 Text for tenders unit Contact load max.: W Pulse value: 92302 48 V AC/DC, 50 mA, 2 1l VZOA 15 FL 130/25-IN0,01 CONTOIL® Oil meter VZOA 15 FL 130/25-IN 0.01 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm Connection for flanges: DN 15 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.01 l 92303 VZOA 20 FL 130/25 CONTOIL® Oil meter VZOA 20 FL 130/25 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 20 mm Connection for flanges: DN 20 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 30...1500 l/h Max. continuous flow Qn: 1000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l 92304 VZOA 20 FL 130/25-RV1 CONTOIL® Oil meter VZOA 20 FL 130/25-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 20 mm Connection for flanges: DN 20 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 30...1500 l/h Max. continuous flow Qn: 1000 l/h Max. measuring deviation: ± 0.5% of measured 81900602 09.2010 7/17 Text for tenders value Repeatability: Smallest readable value: Registration capacity: With RV Reed pulser unit Contact load max.: W Pulse value: 92305 ± 0.1% 0.1 l 10 Mio l integrated in register 48 V AC/DC, 50 mA, 2 1l VZOA 20 FL 130/25-IN0,01 CONTOIL® Oil meter VZOA 20 FL 130/25-IN 0.01 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 20 mm Connection for flanges: DN 20 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 30...1500 l/h Max. continuous flow Qn: 1000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.01 l 92306 VZOA 25 FL 130/25 CONTOIL® Oil meter VZOA 25 FL 130/25 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 25 mm Connection for flanges: DN 25 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 190 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 75...3000 l/h Max. continuous flow Qn: 2000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l 92307 VZOA 25 FL 130/25-RV1 CONTOIL® Oil meter VZOA 25 FL 130/25-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: Connection for flanges: Nominal pressure: 81900602 DN 25 mm DN 25 to DIN 2501 PN 25 bar 09.2010 8/17 Text for tenders Installation length: 190 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 75...3000 l/h Max. continuous flow Qn: 2000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92308 integrated in register 48 V AC/DC, 50 mA, 2 1l VZOA 25 FL 130/25-IN0,1 CONTOIL® Oil meter VZOA 25 FL 130/25-IN 0.1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 25 mm Connection for flanges: DN 25 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 190 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 75...3000 l/h Max. continuous flow Qn: 2000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.1 l 92309 VZOA 40 FL 130/25 CONTOIL® Oil meter VZOA 40 FL 130/25 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 40 mm Connection for flanges: DN 40 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 300 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 225...9000 l/h Max. continuous flow Qn: 6000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l 92310 81900602 VZOA 40 FL 130/25-RV1 09.2010 9/17 Text for tenders CONTOIL® Oil meter VZOA 40 FL 130/25-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 40 mm Connection for flanges: DN 40 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 300 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 225...9000 l/h Max. continuous flow Qn: 6000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92311 integrated in register 48 V AC/DC, 50 mA, 2 1l VZOA 40 FL 130/25-IN0,1 CONTOIL® Oil meter VZOA 40 FL 130/25-IN 0.1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 40 mm Connection for flanges: DN 40 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 300 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 225...9000 l/h Max. continuous flow Qn: 6000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.1 l 92312 VZOA 50 FL 130/25 CONTOIL® Oil meter VZOA 50 FL 130/25 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 50 mm Connection for flanges: DN 50 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 350 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 750...30000 l/h Max. continuous flow Qn: 20000 l/h Max. measuring deviation: ± 0.5% of measured 81900602 09.2010 10/17 Text for tenders value Repeatability: Smallest readable value: Registration capacity: 92313 ± 0.1% 1l 100 Mio l VZOA 50 FL 130/25-RV10 CONTOIL® Oil meter VZOA 50 FL 130/25-RV 10 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 50 mm Connection for flanges: DN 50 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 350 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 750...30000 l/h Max. continuous flow Qn: 20000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 1l Registration capacity: 100 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92314 integrated in register 48 V AC/DC, 50 mA, 2 10 l VZOA 50 FL 130/25-IN1 CONTOIL® Oil meter VZOA 50 FL 130/25-IN 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 50 mm Connection for flanges: DN 50 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 350 mm Installation position: horizontal / vertical Temperature, max.: 130 °C Measuring range (at visc. 1…20 mPa.s): 750...30000 l/h Max. continuous flow Qn: 20000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 1l Registration capacity: 100 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 1l VZOA Flange 180/25 92315 Flange Connection VZOA 15 FL 180/25 CONTOIL® Oil meter VZOA 15 FL 180/25 81900602 09.2010 11/17 Text for tenders Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm Connection for flanges: DN 15 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l 92316 VZOA 15 FL 180/25-RV0,1 CONTOIL® Oil meter VZOA 15 FL 180/25-RV 0.1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm Connection for flanges: DN 15 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92317 integrated in register 48 V AC/DC, 50 mA, 2 0.1 l VZOA 15 FL 180/25-RV1 CONTOIL® Oil meter VZOA 15 FL 180/25-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm Connection for flanges: DN 15 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l With RV Reed pulser 81900602 integrated in register 09.2010 12/17 Text for tenders unit Contact load max.: W Pulse value: 92318 48 V AC/DC, 50 mA, 2 1l VZOA 15 FL 180/25-IN0,01 CONTOIL® Oil meter VZOA 15 FL 180/25-IN 0.01 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 15 mm Connection for flanges: DN 15 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 10...600 l/h Max. continuous flow Qn: 400 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.01 l Registration capacity: 1 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.01 l 92319 VZOA 20 FL 180/25 CONTOIL® Oil meter VZOA 20 FL 180/25 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 20 mm Connection for flanges: DN 20 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 30...1500 l/h Max. continuous flow Qn: 1000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l 92320 VZOA 20 FL 180/25-RV1 CONTOIL® Oil meter VZOA 20 FL 180/25-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 20 mm Connection for flanges: DN 20 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 30...1500 l/h Max. continuous flow Qn: 1000 l/h Max. measuring deviation: ± 0.5% of measured 81900602 09.2010 13/17 Text for tenders value Repeatability: Smallest readable value: Registration capacity: With RV Reed pulser unit Contact load max.: W Pulse value: 92321 ± 0.1% 0.1 l 10 Mio l integrated in register 48 V AC/DC, 50 mA, 2 1l VZOA 20 FL 180/25-IN0,01 CONTOIL® Oil meter VZOA 20 FL 180/25-IN 0.01 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 20 mm Connection for flanges: DN 20 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 165 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 30...1500 l/h Max. continuous flow Qn: 1000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.01 l 92322 VZOA 25 FL 180/25 CONTOIL® Oil meter VZOA 25 FL 180/25 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 25 mm Connection for flanges: DN 25 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 190 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 75...3000 l/h Max. continuous flow Qn: 2000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l 92323 VZOA 25 FL 180/25-RV1 CONTOIL® Oil meter VZOA 25 FL 180/25-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: Connection for flanges: Nominal pressure: 81900602 DN 25 mm DN 25 to DIN 2501 PN 25 bar 09.2010 14/17 Text for tenders Installation length: 190 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 75...3000 l/h Max. continuous flow Qn: 2000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92324 integrated in register 48 V AC/DC, 50 mA, 2 1l VZOA 25 FL 180/25-IN0,1 CONTOIL® Oil meter VZOA 25 FL 180/25-IN 0.1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 25 mm Connection for flanges: DN 25 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 190 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 75...3000 l/h Max. continuous flow Qn: 2000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.1 l 92325 VZOA 40 FL 180/25 CONTOIL® Oil meter VZOA 40 FL 180/25 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 40 mm Connection for flanges: DN 40 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 300 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 225...9000 l/h Max. continuous flow Qn: 6000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l 92326 81900602 VZOA 40 FL 180/25-RV1 09.2010 15/17 Text for tenders CONTOIL® Oil meter VZOA 40 FL 180/25-RV 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 40 mm Connection for flanges: DN 40 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 300 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 225...9000 l/h Max. continuous flow Qn: 6000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92327 integrated in register 48 V AC/DC, 50 mA, 2 1l VZOA 40 FL 180/25-IN0,1 CONTOIL® Oil meter VZOA 40 FL 180/25-IN 0.1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 40 mm Connection for flanges: DN 40 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 300 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 225...9000 l/h Max. continuous flow Qn: 6000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 0.1 l Registration capacity: 10 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 0.1 l 92328 VZOA 50 FL 180/25 CONTOIL® Oil meter VZOA 50 FL 180/25 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 50 mm Connection for flanges: DN 50 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 350 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 750...30000 l/h Max. continuous flow Qn: 20000 l/h Max. measuring deviation: ± 0.5% of measured 81900602 09.2010 16/17 Text for tenders value Repeatability: Smallest readable value: Registration capacity: 92329 ± 0.1% 1l 100 Mio l VZOA 50 FL 180/25-RV10 CONTOIL® Oil meter VZOA 50 FL 180/25-RV 10 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 50 mm Connection for flanges: DN 50 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 350 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 750...30000 l/h Max. continuous flow Qn: 20000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 1l Registration capacity: 100 Mio l With RV Reed pulser unit Contact load max.: W Pulse value: 92330 integrated in register 48 V AC/DC, 50 mA, 2 10 l VZOA 50 FL 180/25-IN1 CONTOIL® Oil meter VZOA 50 FL 180/25-IN 1 Ring piston meter for mineral oil, with rotatable roller counter Nominal diameter: DN 50 mm Connection for flanges: DN 50 to DIN 2501 Nominal pressure: PN 25 bar Installation length: 350 mm Installation position: horizontal / vertical Temperature, max.: 180 °C Measuring range (at visc. 1…20 mPa.s): 750...30000 l/h Max. continuous flow Qn: 20000 l/h Max. measuring deviation: ± 0.5% of measured value Repeatability: ± 0.1% Smallest readable value: 1l Registration capacity: 100 Mio l With built-on inductive IN pulser as per DIN 19234 Supply 5...15 V DC, signal at 8 V DC 1 mA / 3 mA Pulse value: 1l 81900602 09.2010 17/17
© Copyright 2026 Paperzz