CONTOIL® VZOA

Text for tenders
CONTOIL® VZOA 15...50
VZOA ... RC 130/16
92286
Threaded connection
VZOA 15 RC 130/16
CONTOIL® Oil meter VZOA 15 RC 130/16
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
With threaded ends 3/4”
(for couplings 1/2”)
Nominal pressure:
PN 16 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
92287
VZOA 15 RC 130/16-RV0,1
CONTOIL® Oil meter VZOA 15 RC 130/16-RV 0.1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
With threaded ends 3/4”
(for couplings 1/2”)
Nominal pressure:
PN 16 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92288
integrated in register
48 V AC/DC, 50 mA, 2
0.1 l
VZOA 15 RC 130/16-RV1
CONTOIL® Oil meter VZOA 15 RC 130/16-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
With threaded ends 3/4”
(for couplings 1/2”)
Nominal pressure:
PN 16 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
81900602
09.2010
1/17
Text for tenders
92289
Max. measuring deviation:
value
Repeatability:
Smallest readable value:
Registration capacity:
± 0.5% of measured
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
integrated in register
± 0.1%
0.01 l
1 Mio l
48 V AC/DC, 50 mA, 2
1l
VZOA 15 RC 130/16-IN0,01
CONTOIL® Oil meter VZOA 15 RC 130/16-IN 0.01
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
With threaded ends 3/4”
(for couplings 1/2”)
Nominal pressure:
PN 16 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.01 l
92290
VZOA 20 RC 130/16
CONTOIL® Oil meter VZOA 20 RC 130/16
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 20 mm
With threaded ends 1”
(for couplings 3/4”)
Nominal pressure:
PN 16 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
30...1500 l/h
Max. continuous flow Qn:
1000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
92291
VZOA 20 RC 130/16-RV1
CONTOIL® Oil meter VZOA 20 RC 130/16-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
With threaded ends 1”
81900602
DN 20 mm
(for couplings 3/4”)
09.2010
2/17
Text for tenders
Nominal pressure:
PN 16 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
30...1500 l/h
Max. continuous flow Qn:
1000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92292
integrated in register
48 V AC/DC, 50 mA, 2
1l
VZOA 20 RC 130/16-IN0,01
CONTOIL® Oil meter VZOA 20 RC 130/16-IN 0.01
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 20 mm
With threaded ends 1”
(for couplings 3/4”)
Nominal pressure:
PN 16 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
30...1500 l/h
Max. continuous flow Qn:
1000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.01 l
92293
VZOA 25 RC 130/16
CONTOIL® Oil meter VZOA 25 RC 130/16
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 25 mm
With threaded ends 1 1/4”
(for couplings 1”)
Nominal pressure:
PN 16 bar
Installation length:
190 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
75...3000 l/h
Max. continuous flow Qn:
2000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
81900602
09.2010
3/17
Text for tenders
92294
VZOA 25 RC 130/16-RV1
CONTOIL® Oil meter VZOA 25 RC 130/16-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 25 mm
With threaded ends 1 1/4”
(for couplings 1”)
Nominal pressure:
PN 16 bar
Installation length:
190 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
75...3000 l/h
Max. continuous flow Qn:
2000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92295
integrated in register
48 V AC/DC, 50 mA, 2
1l
VZOA 25 RC 130/16-IN0,1
CONTOIL® Oil meter VZOA 25 RC 130/16-IN 0.1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 25 mm
With threaded ends 1 1/4”
(for couplings 1”)
Nominal pressure:
PN 16 bar
Installation length:
190 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
75...3000 l/h
Max. continuous flow Qn:
2000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.1 l
92296
VZOA 40 RC130/16
CONTOIL® Oil meter VZOA 40 RC 130/16
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 40 mm
With threaded ends 2”
(for couplings 1 1/2”)
Nominal pressure:
PN 16 bar
Installation length:
300 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
225...9000 l/h
81900602
09.2010
4/17
Text for tenders
Max. continuous flow Qn:
Max. measuring deviation:
value
Repeatability:
Smallest readable value:
Registration capacity:
92297
6000 l/h
± 0.5% of measured
± 0.1%
0.1 l
10 Mio l
VZOA 40 RC 130/16-RV1
CONTOIL® Oil meter VZOA 40 RC 130/16-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 40 mm
With threaded ends 2”
(for couplings 1 1/2”)
Nominal pressure:
PN 16 bar
Installation length:
300 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
225...9000 l/h
Max. continuous flow Qn:
6000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92298
integrated in register
48 V AC/DC, 50 mA, 2
1l
VZOA 40 RC 130/16-IN0,1
CONTOIL® Oil meter VZOA 40 RC 130/16-IN 0.1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 40 mm
With threaded ends 2”
(for couplings 1 1/2”)
Nominal pressure:
PN 16 bar
Installation length:
300 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
225...9000 l/h
Max. continuous flow Qn:
6000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.1 l
VZOA Flange 130/25
92299
Flange connection
VZOA 15 FL 130/25
CONTOIL® Oil meter VZOA 15 FL 130/25
81900602
09.2010
5/17
Text for tenders
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
Connection for flanges:
DN 15 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
92300
VZOA 15 FL 130/25-RV0,1
CONTOIL® Oil meter VZOA 15 FL 130/25-RV 0.1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
Connection for flanges:
DN 15 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92301
integrated in register
48 V AC/DC, 50 mA, 2
0.1 l
VZOA 15 FL 130/25-RV1
CONTOIL® Oil meter VZOA 15 FL 130/25-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
Connection for flanges:
DN 15 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
With RV Reed pulser
81900602
integrated in register
09.2010
6/17
Text for tenders
unit
Contact load max.:
W
Pulse value:
92302
48 V AC/DC, 50 mA, 2
1l
VZOA 15 FL 130/25-IN0,01
CONTOIL® Oil meter VZOA 15 FL 130/25-IN 0.01
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
Connection for flanges:
DN 15 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.01 l
92303
VZOA 20 FL 130/25
CONTOIL® Oil meter VZOA 20 FL 130/25
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 20 mm
Connection for flanges:
DN 20 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
30...1500 l/h
Max. continuous flow Qn:
1000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
92304
VZOA 20 FL 130/25-RV1
CONTOIL® Oil meter VZOA 20 FL 130/25-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 20 mm
Connection for flanges:
DN 20 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
30...1500 l/h
Max. continuous flow Qn:
1000 l/h
Max. measuring deviation:
± 0.5% of measured
81900602
09.2010
7/17
Text for tenders
value
Repeatability:
Smallest readable value:
Registration capacity:
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92305
± 0.1%
0.1 l
10 Mio l
integrated in register
48 V AC/DC, 50 mA, 2
1l
VZOA 20 FL 130/25-IN0,01
CONTOIL® Oil meter VZOA 20 FL 130/25-IN 0.01
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 20 mm
Connection for flanges:
DN 20 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
30...1500 l/h
Max. continuous flow Qn:
1000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.01 l
92306
VZOA 25 FL 130/25
CONTOIL® Oil meter VZOA 25 FL 130/25
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 25 mm
Connection for flanges:
DN 25 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
190 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
75...3000 l/h
Max. continuous flow Qn:
2000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
92307
VZOA 25 FL 130/25-RV1
CONTOIL® Oil meter VZOA 25 FL 130/25-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
Connection for flanges:
Nominal pressure:
81900602
DN 25 mm
DN 25 to DIN 2501
PN 25 bar
09.2010
8/17
Text for tenders
Installation length:
190 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
75...3000 l/h
Max. continuous flow Qn:
2000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92308
integrated in register
48 V AC/DC, 50 mA, 2
1l
VZOA 25 FL 130/25-IN0,1
CONTOIL® Oil meter VZOA 25 FL 130/25-IN 0.1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 25 mm
Connection for flanges:
DN 25 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
190 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
75...3000 l/h
Max. continuous flow Qn:
2000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.1 l
92309
VZOA 40 FL 130/25
CONTOIL® Oil meter VZOA 40 FL 130/25
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 40 mm
Connection for flanges:
DN 40 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
300 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
225...9000 l/h
Max. continuous flow Qn:
6000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
92310
81900602
VZOA 40 FL 130/25-RV1
09.2010
9/17
Text for tenders
CONTOIL® Oil meter VZOA 40 FL 130/25-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 40 mm
Connection for flanges:
DN 40 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
300 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
225...9000 l/h
Max. continuous flow Qn:
6000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92311
integrated in register
48 V AC/DC, 50 mA, 2
1l
VZOA 40 FL 130/25-IN0,1
CONTOIL® Oil meter VZOA 40 FL 130/25-IN 0.1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 40 mm
Connection for flanges:
DN 40 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
300 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
225...9000 l/h
Max. continuous flow Qn:
6000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.1 l
92312
VZOA 50 FL 130/25
CONTOIL® Oil meter VZOA 50 FL 130/25
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 50 mm
Connection for flanges:
DN 50 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
350 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
750...30000
l/h
Max. continuous flow Qn:
20000 l/h
Max. measuring deviation:
± 0.5% of measured
81900602
09.2010
10/17
Text for tenders
value
Repeatability:
Smallest readable value:
Registration capacity:
92313
± 0.1%
1l
100 Mio l
VZOA 50 FL 130/25-RV10
CONTOIL® Oil meter VZOA 50 FL 130/25-RV 10
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 50 mm
Connection for flanges:
DN 50 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
350 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
750...30000
l/h
Max. continuous flow Qn:
20000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
1l
Registration capacity:
100 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92314
integrated in register
48 V AC/DC, 50 mA, 2
10 l
VZOA 50 FL 130/25-IN1
CONTOIL® Oil meter VZOA 50 FL 130/25-IN 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 50 mm
Connection for flanges:
DN 50 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
350 mm
Installation position:
horizontal / vertical
Temperature, max.:
130 °C
Measuring range (at visc. 1…20 mPa.s):
750...30000
l/h
Max. continuous flow Qn:
20000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
1l
Registration capacity:
100 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
1l
VZOA Flange 180/25
92315
Flange Connection
VZOA 15 FL 180/25
CONTOIL® Oil meter VZOA 15 FL 180/25
81900602
09.2010
11/17
Text for tenders
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
Connection for flanges:
DN 15 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
92316
VZOA 15 FL 180/25-RV0,1
CONTOIL® Oil meter VZOA 15 FL 180/25-RV 0.1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
Connection for flanges:
DN 15 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92317
integrated in register
48 V AC/DC, 50 mA, 2
0.1 l
VZOA 15 FL 180/25-RV1
CONTOIL® Oil meter VZOA 15 FL 180/25-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
Connection for flanges:
DN 15 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
With RV Reed pulser
81900602
integrated in register
09.2010
12/17
Text for tenders
unit
Contact load max.:
W
Pulse value:
92318
48 V AC/DC, 50 mA, 2
1l
VZOA 15 FL 180/25-IN0,01
CONTOIL® Oil meter VZOA 15 FL 180/25-IN 0.01
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 15 mm
Connection for flanges:
DN 15 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
10...600 l/h
Max. continuous flow Qn:
400 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.01 l
Registration capacity:
1 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.01 l
92319
VZOA 20 FL 180/25
CONTOIL® Oil meter VZOA 20 FL 180/25
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 20 mm
Connection for flanges:
DN 20 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
30...1500 l/h
Max. continuous flow Qn:
1000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
92320
VZOA 20 FL 180/25-RV1
CONTOIL® Oil meter VZOA 20 FL 180/25-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 20 mm
Connection for flanges:
DN 20 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
30...1500 l/h
Max. continuous flow Qn:
1000 l/h
Max. measuring deviation:
± 0.5% of measured
81900602
09.2010
13/17
Text for tenders
value
Repeatability:
Smallest readable value:
Registration capacity:
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92321
± 0.1%
0.1 l
10 Mio l
integrated in register
48 V AC/DC, 50 mA, 2
1l
VZOA 20 FL 180/25-IN0,01
CONTOIL® Oil meter VZOA 20 FL 180/25-IN 0.01
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 20 mm
Connection for flanges:
DN 20 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
165 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
30...1500 l/h
Max. continuous flow Qn:
1000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.01 l
92322
VZOA 25 FL 180/25
CONTOIL® Oil meter VZOA 25 FL 180/25
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 25 mm
Connection for flanges:
DN 25 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
190 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
75...3000 l/h
Max. continuous flow Qn:
2000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
92323
VZOA 25 FL 180/25-RV1
CONTOIL® Oil meter VZOA 25 FL 180/25-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
Connection for flanges:
Nominal pressure:
81900602
DN 25 mm
DN 25 to DIN 2501
PN 25 bar
09.2010
14/17
Text for tenders
Installation length:
190 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
75...3000 l/h
Max. continuous flow Qn:
2000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92324
integrated in register
48 V AC/DC, 50 mA, 2
1l
VZOA 25 FL 180/25-IN0,1
CONTOIL® Oil meter VZOA 25 FL 180/25-IN 0.1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 25 mm
Connection for flanges:
DN 25 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
190 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
75...3000 l/h
Max. continuous flow Qn:
2000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.1 l
92325
VZOA 40 FL 180/25
CONTOIL® Oil meter VZOA 40 FL 180/25
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 40 mm
Connection for flanges:
DN 40 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
300 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
225...9000 l/h
Max. continuous flow Qn:
6000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
92326
81900602
VZOA 40 FL 180/25-RV1
09.2010
15/17
Text for tenders
CONTOIL® Oil meter VZOA 40 FL 180/25-RV 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 40 mm
Connection for flanges:
DN 40 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
300 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
225...9000 l/h
Max. continuous flow Qn:
6000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92327
integrated in register
48 V AC/DC, 50 mA, 2
1l
VZOA 40 FL 180/25-IN0,1
CONTOIL® Oil meter VZOA 40 FL 180/25-IN 0.1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 40 mm
Connection for flanges:
DN 40 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
300 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
225...9000 l/h
Max. continuous flow Qn:
6000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
0.1 l
Registration capacity:
10 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
0.1 l
92328
VZOA 50 FL 180/25
CONTOIL® Oil meter VZOA 50 FL 180/25
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 50 mm
Connection for flanges:
DN 50 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
350 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
750...30000
l/h
Max. continuous flow Qn:
20000 l/h
Max. measuring deviation:
± 0.5% of measured
81900602
09.2010
16/17
Text for tenders
value
Repeatability:
Smallest readable value:
Registration capacity:
92329
± 0.1%
1l
100 Mio l
VZOA 50 FL 180/25-RV10
CONTOIL® Oil meter VZOA 50 FL 180/25-RV 10
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 50 mm
Connection for flanges:
DN 50 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
350 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
750...30000
l/h
Max. continuous flow Qn:
20000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
1l
Registration capacity:
100 Mio l
With RV Reed pulser
unit
Contact load max.:
W
Pulse value:
92330
integrated in register
48 V AC/DC, 50 mA, 2
10 l
VZOA 50 FL 180/25-IN1
CONTOIL® Oil meter VZOA 50 FL 180/25-IN 1
Ring piston meter for mineral oil, with rotatable roller counter
Nominal diameter:
DN 50 mm
Connection for flanges:
DN 50 to DIN 2501
Nominal pressure:
PN 25 bar
Installation length:
350 mm
Installation position:
horizontal / vertical
Temperature, max.:
180 °C
Measuring range (at visc. 1…20 mPa.s):
750...30000
l/h
Max. continuous flow Qn:
20000 l/h
Max. measuring deviation:
± 0.5% of measured
value
Repeatability:
± 0.1%
Smallest readable value:
1l
Registration capacity:
100 Mio l
With built-on inductive IN pulser
as per DIN 19234
Supply 5...15 V DC, signal at 8 V DC  1 mA /  3 mA
Pulse value:
1l
81900602
09.2010
17/17