Text for tenders AMTRON S2 Compact mechanical heat and cooling meter Heating, mounting on Return line 95162 AMTRON S2+ 15 1.5_110_G3/4 B10 Compact mechanical heat meter Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95163 15 ... 90°C 5 … 55°C PN 16 DN 15 1.5 m3/h 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 0.200 bar 3.35 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10 Compact mechanical heat meter Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power 81919489 12.2014 1/18 Text for tenders Optical interface (M-bus protocol) Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95164 1 ... 90°C 5 … 55°C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.170 bar 6.06 m3/h Return line AMTRON S2+ 15 1.5_110_G3/4 B10M Compact mechanical heat meter with M-Bus Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) With M-Bus according EN1434-3 / EN13757 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95165 15 ... 90°C 5 … 55°C PN 16 DN 15 1.5 m3/h 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 0.200 bar 3.35 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10M Compact mechanical heat meter with M-Bus Return line Highly accurate single-jet flow sensor 81919489 12.2014 2/18 Text for tenders Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) With M-Bus according EN1434-3 / EN13757 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95166 15 ... 90°C 5 … 55°C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.170 bar 6.06 m3/h Return line AMTRON S2+ 15 1.5_110_G3/4 B10MEE Compact mechanical heat meter with M-Bus and 2 pulse inputs Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) With M-Bus according EN1434-3 / EN13757 2 pulse inputs for the integration of a cold and a warm water meter Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: 81919489 15 ... 90°C 12.2014 3/18 Text for tenders Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95167 5 … 55°C PN 16 DN 15 1.5 m3/h 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 0.200 bar 3.35 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10MEE Compact mechanical heat meter with M-Bus and 2 pulse inputs Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) With M-Bus according EN1434-3 / EN13757 2 pulse inputs for the integration of a cold and a warm water meter Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95168 15 ... 90°C 5 … 55°C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.170 bar 6.06 m3/h Return line AMTRON S2+ 15 1.5_110_G3/4 B10R Compact mechanical heat meter with Radio Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) 81919489 12.2014 4/18 Text for tenders Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Wireless M-Bus (Radio) 868 MHz according EN13757 OMS compliant modes S1 / T1 and S2 / T2 short or long telegram for WALK-BY or AMR read out transmission interval 2 … 240 min free choice of transmission times encryption AES 128 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95169 15 ... 90°C 5 … 55°C PN 16 DN 15 1.5 m3/h 3.0 m3/h 7 l/h 110 mm G3/4" 0.200 bar 3.35 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10R Compact mechanical heat meter with Radio Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Wireless M-Bus (Radio) 868 MHz according EN13757 OMS compliant for modes S1 / T1 and S2 / T2 short or long telegram for WALK-BY or AMR read out transmission interval: 2 … 240 min 81919489 12.2014 5/18 Text for tenders free choice of transmission times encryption AES 128 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95170 15 ... 90°C 5 … 55°C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.170 bar 6.06 m3/h Return line AMTRON S2+ 15 1.5_110_G3/4 B10REE Compact mechanical heat meter with Radio and 2 pulse inputs Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Wireless M-Bus (Radio) 868 MHz according EN13757 OMS compliant for modes S1 / T1 and S2 / T2 short or long telegram for WALK-BY or AMR read out transmission interval: 2 … 240 min free choice of transmission times encryption AES 128 2 pulse inputs for the integration of a cold and a warm water meter Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: 81919489 15 ... 90°C 5 … 55°C PN 16 DN 15 1.5 m3/h 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 12.2014 6/18 Text for tenders Pressure loss at qp: Value Kvs: Meter mounted: 95171 0.200 bar 3.35 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10REE Compact mechanical heat meter with Radio and 2 pulse inputs Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Wireless M-Bus (Radio) 868 MHz according EN13757 OMS compliant for modes S1 / T1 and S2 / T2 short or long telegram for WALK-BY or AMR read out transmission interval: 2 … 240 min free choice of transmission times encryption AES 128 2 pulse inputs for the integration of a cold and a warm water meter Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95172 15 ... 90°C 5 … 55°C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.170 bar 6.06 m3/h Return line AMTRON S2+ 15 1.5_110_G3/4 B5A Compact mechanical heat meter with pulse output Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor 81919489 12.2014 7/18 Text for tenders Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 5+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Potential-free pulse output (class A0 according to EN1434) 1kWh / pulse Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 15 ... 90°C 5 … 55°C PN 16 DN 15 1.5 m3/h 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 0.200 bar 3.35 m3/h Return line Heating and Cooling, mounting on return line 95175 AMTRON S2+ 15 1.5_110_G3/4 B10-h&c Compact mechanical energy meter for heating and cooling Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: 81919489 5 ... 90°C 5 … 55°C PN 16 DN 15 1.5 m3/h 12.2014 8/18 Text for tenders Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95176 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 0.200 bar 3.35 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10-h&c Compact mechanical energy meter for heating and cooling Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95177 5 ... 90°C 5 … 55°C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.170 bar 6.06 m3/h Return line AMTRON S2+ 15 1.5_110_G3/4 B10M-h&c Compact mechanical energy meter for heating and cooling with M-Bus Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 81919489 12.2014 9/18 Text for tenders Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) With M-Bus according EN1434-3 / EN13757 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95178 5 ... 90°C 5 … 55°C PN 16 DN 15 1.5 m3/h 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 0.200 bar 3.35 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10M-h&c Compact mechanical energy meter for heating and cooling with M-Bus Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) With M-Bus according EN1434-3 / EN13757 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 81919489 5 ... 90°C 5 … 55°C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.170 bar 6.06 m3/h Return line 12.2014 10/18 Text for tenders 95179 AMTRON S2+ 15 1.5_110_G3/4 B10MEE-h&c Compact mechanical energy meter for heating and cooling with M-Bus and 2 pulse inputs, Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) With M-Bus according EN1434-3 / EN13757 2 pulse inputs for the integration of a cold and a warm water meter Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95180 5 ... 90°C 5 … 55°C PN 16 DN 15 1.5 m3/h 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 0.200 bar 3.35 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10MEE-h&c Compact mechanical energy meter for heating and cooling with M-Bus and 2 pulse inputs, Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) 81919489 12.2014 11/18 Text for tenders With M-Bus according EN1434-3 / EN13757 2 pulse inputs for the integration of a cold and a warm water meter Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95181 5 ... 90°C 5 … 55°C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.170 bar 6.06 m3/h Return line AMTRON S2+ 15 1.5_110_G3/4 B10R-h&c Compact mechanical heat meter for heating and cooling with Radio Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Wireless M-Bus (Radio) 868 MHz according EN13757 OMS compliant for modes S1 / T1 and S2 / T2 short or long telegram for WALK-BY or AMR read out transmission interval: 2 … 240 min free choice of transmission times encryption AES 128 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: 81919489 5 ... 90°C 5 … 55°C PN 16 DN 15 1.5 m3/h 3.0 m3/h 7 l/h 110 mm G3/4" 0.200 bar 3.35 m3/h 12.2014 12/18 Text for tenders Meter mounted: 95182 Return line AMTRON S2+ 20 2.5_130_G1 B10R-h&c Compact mechanical energy meter for heating and cooling with Radio Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Wireless M-Bus (Radio) 868 MHz according EN13757 OMS compliant for modes S1 / T1 and S2 / T2 short or long telegram for WALK-BY or AMR read out transmission interval: 2 … 240 min free choice of transmission times encryption AES 128 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95183 5 ... 90°C 5 … 55°C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.170 bar 6.06 m3/h Return line AMTRON S2+ 15 1.5_110_G3/4 B10REE-h&c Compact mechanical energy meter for heating and cooling with Radio and 2 pulse inputs, Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting 81919489 12.2014 13/18 Text for tenders Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Wireless M-Bus (Radio) 868 MHz according EN13757 OMS compliant for modes S1 / T1 and S2 / T2 short or long telegram for WALK-BY or AMR read out transmission interval: 2 … 240 min free choice of transmission times encryption AES 128 2 pulse inputs for the integration of a cold and a warm water meter Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95184 5 ... 90°C 5 … 55°C PN 16 DN 15 1.5 m3/h 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 0.200 bar 3.35 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10REE-h&c Compact mechanical energy meter for heating and cooling with Radio and 2 pulse inputs, Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Wireless M-Bus (Radio) 868 MHz according EN13757 OMS compliant for modes S1 / T1 and S2 / T2 short or long telegram for WALK-BY or AMR read out transmission interval: 2 … 240 min free choice of transmission times 2 pulse inputs for the integration of a cold and a warm water meter 81919489 12.2014 14/18 Text for tenders encryption AES 128 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to 2004/22/EC (MID) Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 5 ... 90°C 5 … 55°C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.170 bar 6.06 m3/h Return line Cooling, mounting return line 95185 AMTRON S2+ 15 1.5_110_G3/4 B10M-ws/c Compact mechanical energy meter for cooling with M-Bus Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) With M-Bus according EN1434-3 / EN13757 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to PTB K 7.2 Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95186 81919489 5 ... 50°C 5 … 55 °C PN 16 DN 15 1.5 m3/h 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 0.230 bar 3.6 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10M-ws/c 12.2014 15/18 Text for tenders Compact mechanical energy meter for cooling with M-Bus Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) With M-Bus according EN1434-3 / EN13757 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to PTB K 7.2 Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95187 5 ... 50°C 5 … 55 °C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm G1" 0.240 bar 6.0 m3/h Return line AMTRON S2+ 15 1.5_110_G3/4 B10R-ws/c Compact mechanical energy meter for cooling with Radio Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Wireless M-Bus (Radio) 868 MHz according EN13757 OMS compliant for modes S1 / T1 and S2 / T2 81919489 12.2014 16/18 Text for tenders short or long telegram for WALK-BY or AMR read out transmission interval: 2 … 240 min free choice of transmission times encryption AES 128 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to PTB K 7.2 Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 95188 5 ... 50°C 5 … 55 °C PN 16 DN 15 1.5 m3/h 3.0 m3/h 30 l/h 7 l/h 110 mm G3/4" 0.230 bar 3.6 m3/h Return line AMTRON S2+ 20 2.5_130_G1 B10R-ws/c Compact mechanical energy meter for cooling with Radio Return line Highly accurate single-jet flow sensor Calculator rotatable Calculator removable with 0.3 m cable 2 temperature sensors Pt 500 (Ø 5 mm) (cable length 1.5 m) Temperature sensor return line integrated in flow sensor Temperature sensor supply line with screwing CEN M10x1 Comfortable LC-display with 8 digits Horizontal or vertical mounting Metrological class 3 according EN 1434 Dynamically controlled measuring cycle from 12.5 ... 60 sec Battery 10+1 years Display MWh 15 months memory Storage of maximum values for flow and power Optical interface (M-bus protocol) Wireless M-Bus (Radio) 868 MHz according EN13757 OMS compliant for modes S1 / T1 and S2 / T2 short or long telegram for WALK-BY or AMR read out transmission interval: 2 … 240 min free choice of transmission times encryption AES 128 Protection class IP54 Electromagnetic environment C according EN 1434 Approvals according to PTB K 7.2 Temperature range: Ambient temperature: Nominal pressure: Nominal diameter: Nominal flowrate qp: Maximum flowrate qs: Minimum flowrate qi: Low flow threshold value: Installation length: 81919489 5 ... 50°C 5 … 55 °C PN 16 DN 20 2.5 m3/h 5.0 m3/h 50 l/h 10 l/h 130 mm 12.2014 17/18 Text for tenders Connecting thread: Pressure loss at qp: Value Kvs: Meter mounted: 81919489 G1" 0.240 bar 6.0 m3/h Return line 12.2014 18/18
© Copyright 2024 Paperzz