HW#1 1) For the calibration data of the Table below, determine the static sensitivity of the system at (a) x=5; (b) x=10; (c) x=20. For which input values is the system more sensitive? Explain what this might mean in terms of a measurement and in terms of measurement errors. X [cm] Y [V] 0.5 0.4 1.0 1.0 2.0 2.3 5.0 6.9 10.0 15.8 20.0 36.4 50.0 110.1 100.0 253.2 2) The following data have the form Y = aXb . Plot the data in an appropriate format to estimate the coefficients a and b. Estimate the static sensitivity K at each value of X. How is K affected by X? X[cm] Y[cm] 0.5 0.14 2.0 2.51 5.0 15.30 10.0 63.71 3) The relation between the flow rate through a pipeline of area, A, and the pressure drop, p, across an orifice-type flow meter inserted in that line is given by Q CA 2 p For a pipe diameter of 1 m and a flow range of 20C water between 2 and 10 m3/min and C=0.75, plot the expected form of the calibration curve for flow rate versus pressure drop over the flow range. Is the static sensitivity a constant?