PROJECT NAME DATE ____________________________________________________________________________ SECTION 10 22 39 FOLDING PARTITIONS PART 1 – GENERAL **NOTE: THE PK30 ACCORDION FOLDING SYSTEMS ARE FOR FOLDING PARTITIONS WEIGHING UP TO 176 LBS (80 KG) PER PANEL. REFER TO THE PK30 SYSTEM WEIGHT CALCULATOR EXCEL SPREADSHEET TO CONFIRM THAT INDIVIDUAL PANEL WEIGHT IS UNDER THE SYSTEM’S LIMITATIONS. ONE-SIDED INSTALLATIONS ARE POSSIBLE UP TO 6000 MM (19 FEET-8 INCHES OR 732 INCHES) IN WIDTH OR DOUBLE THIS FIGURE FOR TWO-SIDED (MIRRORED) INSTALLATIONS. A TOP & BOTTOM CENTER PIVOT HINGE SECURES THE FIRST PANEL IN THE SET, SUBSEQUENT PANELS ARE HINGED TOGETHER. THE VARIOFOLD SYSTEM’S SUSPENSION POINT IS AT THE END OF THE PANEL, PANELS ARE OFFSET TO THE SUSPENSION TRACK WHEN FOLDED/STACKED. VARIOFOLD MUST BE INSTALLED WITH A CONTINUOUS BOTTOM GUIDE CHANNEL FOR CONFIGURATIONS WITH MORE THAN TWO PANELS, ALL PANELS MAY BE EQUAL IN WIDTH. THE CENTERFOLD SYSTEM’S MID-POINT PANEL SUSPENSION ALLOWS INSTALLATIONS WITHOUT A CONTINUOUS RECESSED BOTTOM GUIDE CHANNEL, BOTTOM RAIL LOCKS & DUST-PROOF STRIKES KEEP THE CENTERFOLD WALL SECURE WHEN CLOSED. THE GEOMETERY OF THE CENTERFOLD SYSTEM REQUIRES THE FIRST PANEL TO BE ROUGHLY HALF THE WIDTH OF SUBSEQUENT PANELS. GENERAL NOTES: A COMMUNICATING PIVOT DOOR MAY BE ADDED TO THE PANEL STACK, OR TO THE OPPOSING END. ATTACHED TO EVERY OTHER PANEL IS A FOLDING/PIVOT DOOR CATCH WITH AN INTEGRATED, INDIVIDUALLY ADJUSTABLE RETAINER TO HOLD THE FOLDING WALL FLUSH WHEN CLOSED. BOTH VARIANTS HOLD MANY OTHER ACCOMMODATING ADVANTAGES; EASY PLANNING AND INSTALLATION, EXTREMELY QUIET RUNNING PROPERTIES, LOW PARKING AREA SPACE REQUIREMENTS AND EXCELLENT QUALITY WITH REGARD TO MATERIALS AND FINISH. **NOTE: SPECIAL CONDITIONS CAN BE ACCOMMODATED. PLEASE CONTACT PK30 SYSTEM IF YOUR PROJECT HAS UNUSUAL REQUIREMENTS OR CONDITIONS THAT HAVE NOT BEEN SPECIFICALLY ADDRESSED. SPECIALIZED SOLUTIONS ARE AVAILABLE UPON REQUEST.** 1.1 SUMMARY A. Section includes folding partitions as shown on the drawings, inferable therefrom and as specified. 1. Folding partitions includes the following: Provide all elements from a single manufacturer. ____________________________________________________________________________ Folding Partitions – 10 22 39 Page 1 PROJECT NAME DATE ____________________________________________________________________________ **NOTE: EDIT “a” BELOW FOR THE TYPES OF PARTITION SYSTEM FOR THE PROJECT.** a. Metal framed glass folding partitions including all accessories. **NOTE: THE SYSTEM MAY INCLUDE SWINGING DOORS. DELETE BELOW IF NO DOORS AND REVIEW THE ENTIRE SECTION CAREFULLY WHERE OTHER REFERENCES TO DOORS SHOULD BE DELETED.** b. Integrated metal framed glass doors including all accessories. 1.2 REFERENCES B. Reference Standards: Publications referenced in the text of this Section are listed by source, designation, where applicable, and title. 1. AAMA 611.98: Voluntary Specification for Anodized Architectural Aluminum. 1.3 ADMINISTRATIVE REQUIREMENTS A. Coordination: 1. Single Responsibility: Assign undivided responsibility of the folding partitions to a single firm specializing in this type of work. Do not engage a firm unacceptable to the manufacturer of the system. The firm shall engage other specialty firms to perform any part of the work which he is not equipped or qualified to perform with their own personnel. **NOTE: CHOOSE ABOVE OR BELOW. ABOVE FOR USE OF JUST THIS SECTION. BELOW WHERE SOME OR ALL OF THE FOLLOWING SECTIONS ARE PART OF THE PROJECT.** 1. Single Responsibility: Assign undivided responsibility of the following scopes of work to a single firm specializing in these types of work. Do not engage a firm unacceptable to the manufacturer of the system. The firm shall engage other specialty firms to perform any part of the work which he is not equipped or qualified to perform with their own personnel. **NOTE: EDIT BELOW FOR ONLY THOSE SECTIONS USED.** a. Section 10 22 19, DEMOUNTABLE PARTITIONS. b. Section 10 22 43, SLIDING PARTITIONS. c. Section 10 22 44, SLIDING-STACKING PARTITIONS. d. Section 10 22 45, OFFICE ENTRANCES. **NOTE: USE “2” ONLY WHEN CHOOSING THE SECOND OPTION FOR “1” AND EDITE THE REFERENCE SECTIONS AS REQUIRED.** 2. Coordinated Submittals: Coordinate submittals with the following Sections: a. Section 10 22 19, DEMOUNTABLE PARTITIONS. b. Section 10 22 43, SLIDING PARTITIONS. c. Section 10 22 44, SLIDING-STACKING PARTITIONS. d. Section 10 22 45, OFFICE ENTRANCES. ____________________________________________________________________________ 10 22 39 – Folding Partitions Page 2 PROJECT NAME DATE ____________________________________________________________________________ B. Preinstallation Meetings: Prior to the installation of folding partitions, and at the Contractor's direction, meet at the project site to review the installation procedures and methods. 1.4 ACTION SUBMITTALS A. Product Data: Submit manufacturer's product data and hardware details including rough in requirements and dimensions, installation instructions, and parts lists for all folding partitions and accessories required. 1. The broad application range requires that the HAWA-Variotec 150/H Modular wall hardware system be custom engineered to attain the best solution for a given project. **NOTE: BELOW IN SHOP DRAWINGS, THE SUPPORT FOR THE SYSTEM IS NOT INCLUDED. SYSTEM REQUIREMENTS FOR THE SUSPENSION TRACK ARE DEPENDENT UPON THE STRUCTURE/ARCHITECTURE OF THE GIVEN APPLICATION, THEREFORE THE ARCHITECT/DESIGNER’S ENGINEERING CONSULTANT SHOULD DETERMINE THE NECESSARY STRUCTURAL REQUIREMENTS FOR SUPPORTING THE SUSPENSION TRACK ACCORDING TO LOCAL CODES AND CALCULATIONS MADE OF EXISTING CONDITIONS. PK30 WILL OFFER ALL ASSISTANCE POSSIBLE INCLUDING BUT NOT LIMITED TO PANEL WEIGHTS, COMBINED PARKING AREA WEIGHTS FOR LOADING CALCULATIONS, AND EXAMPLES OF POSSIBLE SUPPORT METHODOLOGIES.** B. Shop Drawings: Prior to ordering materials, submit shop drawings for the fabrication and installation of folding partitions. As specified under Existing Conditions, note all field measurements required on the shop drawings. Include large scale elevations, details, and sections of all component members anchorage, jointing, and other accessories as follows: 1. Layout and installation details, including relationship to adjacent work. 2. Elevations at minimum 1/4 inch equals 1 foot scale. 3. Detail sections of typical members. 4. Anchors and reinforcement. 5. Hardware mounting locations including dimensions. 6. Glazing details. C. Samples: 1. Initial Selection Requirements: a. Colors: Provide manufacturer’s standard coupon samples of each color required. 2. Verification Requirements: Provide only after approval of color selections. a. Profiles: Submit the required sets of samples of each component with each finish on 12 inch long sections. Where color variations are anticipated include two or more units in each set of samples indicating the anticipated range. ____________________________________________________________________________ Folding Partitions – 10 22 39 Page 3 PROJECT NAME DATE ____________________________________________________________________________ b. c. Corner Fabrication: 8 inch long legs of full-size corners, including fullsize sections of extrusions with factory-applied color finish. Glazing: Manufacturer's standard-size unit, but not less than 3 inches square. 1.5 INFORMATIONAL SUBMITTALS A. Sustainable Design Submittals: 1. Recycled Content: Submit certification letter from material suppliers certifying specified percentage requirements of recycled content indicating percentages by weight of post-consumer and pre-consumer recycled content. Include statement indicating costs for each product provided. 1.6 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: 1. Provide manufacturer's care instructions for maintenance of folding partitions including cleaning instructions, operating instructions and precautions, and any limitations. B. Warranty Documentation: Provide signed warranty as specified. 1.7 QUALITY ASSURANCE A. Qualifications: Personnel engaged in the work shall be able to demonstrate successful experience with work of comparable extent, complexity and quality to that shown and specified, including quality control and testing procedures. This includes the following additional requirements: 1. Manufacturers: Capable of providing complete, precision built, engineered, pre-fitted units with a minimum 10 years’ experience in the sale of foldingsliding door systems for large openings in the North American market. 2. Installers: Experienced in the installation of the manufacturer’s products or other similar products for large openings. Provide reference list of at least 3 projects of similar scale and complexity successfully completed in the last 3 years. a. Installers shall be trained and certified by the manufacturer. **NOTE: BELOW FIRST TIME INSTALLER PROGRAM’S INSTALLATION SUPERVISION AND ASSISTANCE COSTS $700.00 PER DAY PLUS TRAVEL AND HOTEL EXPENSES. A 2 DAY CERTIFICATION SERVICE IS THE MINIMUM REQUIREMENT FOR INSTALLATION CERTIFICATION. INSTALLATIONS WITHOUT PK30 CERTIFICATION ARE NOT WARRANTED. SERVICE CALLS TO ADJUST AND REPAIR THE PK30 PRODUCT ON UNCERTIFIED INSTALLATIONS WILL BE BILLED TO CUSTOMER AT A RATE OF $700.00 PER DAY PLUS TRAVEL AND LODGING EXPENSES.** ____________________________________________________________________________ 10 22 39 – Folding Partitions Page 4 PROJECT NAME DATE ____________________________________________________________________________ b. B. First Time Installer Program: Where the installer has been trained and certified by the manufacturer but where this is the installer’s first time installation of the manufacturer’s product, the manufacturer shall provide a full time, on site, installation supervisor for a minimum of 2 days to ensure that the system is correctly installed Single Source Limitation: Provide all components and accessories for folding partitions from a single manufacturer. 1.8 DELIVERY, STORAGE, AND HANDLING A. Delivery, Storage and Handling Requirements: Deliver materials to job site in manufacturers original sealed, unopened cartons or crates. Protect units from damage. Store on pallets in dry, weather protected locations and free from dirt, dust, construction debris. Comply with the manufacturer’s requirements for protection including limitations for the contact of any protective materials. Storage area shall be free from the requirement to move or relocate delivered materials prior to installation. 1.9 SITE CONDITIONS A. Ambient Requirements: Do not deliver or install folding partitions or components until the installation site is enclosed and all finishing including ceiling, floor covering and painting are completed. B. Existing Conditions: 1. Manufacturer’s shop drawing dimensions, including tolerances shall be based on the Architect’s drawings. 2. Verify with field measurements prior to fabrication the dimensions of openings, and stack storage area. Mark field measurements on shop drawing submittal. 3. Where field dimensions cannot be verified, the General Contractor shall be responsible for maintaining the tolerances required for installation. 1.10 WARRANTY A. Manufacturer’s Warranty: Submit copies of written warranty, signed by the manufacturer and the installer, agreeing to repair or replace defective components and work which has failed. Repairs and replacements required because of failure of materials or workmanship shall be completed without additional expense to the Owner. The period of the warranty shall be an extension to 2 years starting on the date of acceptance by the Owner for substantial completion. Failures include but are not limited to the following: 1. Component structural failure including excessive deflection. ____________________________________________________________________________ Folding Partitions – 10 22 39 Page 5 PROJECT NAME DATE ____________________________________________________________________________ 2. 3. Faulty operation of components or hardware. Deterioration of metals, metal finishes including coatings. PART 2 – PRODUCTS 2.1 SYSTEMS A. Manufacturer: Substitutions will not be permitted. Provide precision built, preengineered, pre-fitted sliding partition system from the following: 1. PK30 System LLC PO BOX 656 3607 Atwood Road Stone Ridge, NY 12484 (212) 473-8050 (845) 687-9774 website: www.pk30.com email: [email protected] **NOTE: EDIT BELOW IF NO SWINGING DOORS.** B. Product: Sliding partition system for folding metal framed panels and integrated metal framed glass door including all hardware, accessories, and anchorages. 1. PK30 System. C. Sustainability Requirements: **NOTE: BELOW IS BASED ON LEED V3. VERIFY AND MODIFY AS REQUIRED.** 1. Recycled Content: a. Products shall have a minimum recycled content of 40 percent preconsumer and 22 percent post consumer. D. E. Performance/Design Criteria: Provide partitions and doors of dimensions and configurations shown complying with performance requirements specified. 1. Loading: a. Withstand gravity loads. b. Limit lateral deflection to less than L/175 or 3/4 inch, whichever is less, complying with ASTM E72 tested under a uniformly distributed load of 5 pounds per square foot. 2. Glass Deflection: a. Limit lateral deflections of glass panel edges to less than L/175 of glass-edge length or 3/4 inch, whichever is less. Materials: 1. Aluminum: Alloy and temper recommended by the manufacturer for strength, corrosion resistance, and application of required finish. a. Comply with the following: 1) Aluminum Extrusions: ASTM B 221, Alloy 6063, T6,T5/T52. ____________________________________________________________________________ 10 22 39 – Folding Partitions Page 6 PROJECT NAME DATE ____________________________________________________________________________ 2) Aluminum Sheet or Plate: ASTM B 209, Alloy 6061, T6. 3) Aluminum Bars, Rod and Wire: ASTM B 221, Alloy 6063, T6. b. Provide main extrusions of not less than 0.080-inch wall thickness, profiles as shown. c. Provide extruded glazing stops and other applied trim extrusions with minimum wall thickness of 0.050-inch. 2. Fasteners; Provide 18/8 stainless steel, or other non-corrosive metal fasteners compatible with aluminum components, hardware, anchors, and other items being fastened. a. Reinforcement: Where fasteners screw anchor into aluminum extrusions where there is no screw boss, or that is less than 0.125inch thick, reinforce the interior with aluminum or steel as required to receive screw threads. b. Exposed fasteners: Provide all exposed fasteners shall be flat socket head or Phillips head 18/8 stainless steel machine screws, use only one type of exposed fastener for all work. 3. Glazing: a. Glazing System: Use manufacturer's standard glazing system of setting blocks, gaskets, and glazing tapes as required to cushion the glass and prevent metal to glass contact. b. Glass: Provide manufacturer’s glass of the type as selected by the Architect. Where custom glass is selected, coordinate with the sliding partition manufacturer for factory glazing before shipment to the site. **NOTE: DELETE BELOW OR SPECIFY AS REQUIRED. THE SYSTEM CAN ACCOMMODATE MANY PANEL TYPES (WOOD, GLASS, PLASTIC, METAL) WITH A THICKNESS RANGING BETWEEN 1/4 INCH AND 9/16 INCH. WHERE WOOD IS COORDINATE WITH ARCHITECTURAL WOODWORK, CONSIDER REFERENCING SECTION 06 40 00 AND DESCRIBE THE WOOD PANELS THERE COORDINATING THAT THEY ARE REQUIRED TO BE PROVIDED TO THE PARTITION INSTALLER FOR INSTALLATION.** c. Panels: xxx. F. Fabrication: 1. Provide shop assembled panels with hardware and accessories required for a complete assembly. Provide concealed fastening devices and pressure-fit components that will not damage ceiling or floor coverings. Fabricate panels with light and sound seals at floor, ceiling, and other locations where panels abut fixed construction. 2. Factory prepare interior aluminum frames to receive templated mortised hardware; include cutouts, reinforcements, mortising, drilling, and tapping, 3. Fabricate frames for glazing with removable stops to allow glazing replacement without dismantling frame. 4. Fabricate components to allow secure installation without exposed fasteners. ____________________________________________________________________________ Folding Partitions – 10 22 39 Page 7 PROJECT NAME DATE ____________________________________________________________________________ G. Design Configuration: **NOTE: COORDINATE ALL OF THE CONFIGURATIONS DESCRIBED WITH WHAT IS SHOWN DELETE THOSE NOT REQUIRED.** 1. Sizes and Configurations: As shown for selected number and size of panels, location of swing panels, and location of tracks and stacking bays. 2. Operation: Adjustable sliding and swinging hardware with the following track options: **NOTE: EDIT BELOW TRACK CONFIGURATIONS AS REQUIRED.** a. Top and bottom tracks. b. Top tracks, bottom track will not be permitted. c. Top and bottom tracks as shown, some locations a bottom track will not be permitted. 3. Panel Configurations: **NOTE: EDIT BELOW PANEL CONFIGURATIONS AS REQUIRED.** a. One-sided Installation comprised of ( ) Panels. b. Two-sided (Bi-Parting Folding Wall) installation comprised of ( ) Panels. c. With Pivot Door added to Stack. d. With Pivot Door added opposite stack. 4. Mounting Types: **NOTE: EDIT BELOW MOUNTING TYPES AS REQUIRED.** a. Surface mounted. b. Recessed mounted. H. Finishes: **NOTE: DELETE OR EDIT THE DIFFERENT FINISH SYSTEMS AS REQUIRED. A PROJECT MAY HAVE ONLY ONE OR SEVERAL DIFFERENT SYSTEMS, OR SEVERAL COLORS OF BAKED ENAMEL. COORDINATE WITH DRAWINGS AS REQUIRED TO DESIGNATE LOCATIONS.** 1. Anodized Coating: Provide the following for all aluminum work shown or specified to receive anodized finishes, NAAMM nomenclature, as required to match Architect's sample: a. Clear Anodized Finish: AA-M12C22A41, Class I, 0.07 mm or thicker. 1) Color: Manufacturer’s medium matte clear finish. b. Color Anodized Finish: AA-M12C22A42/A44, Class I, 0.07 mm or thicker. 1) Color: Manufacturer’s medium matte black finish. 2. Baked Enamel Coating: Thermosetting acrylic enamel coating shall be factory applied and shall meet the high performance requirements of AAMA 2603. a. Preparation: Prepare surfaces in accordance with coating manufacturer’s written recommendations. This shall include pretreatment and primer. ____________________________________________________________________________ 10 22 39 – Folding Partitions Page 8 PROJECT NAME DATE ____________________________________________________________________________ b. Coating films shall be uniform and free from flow lines, streaks, blisters, sags or other surface imperfections in dry film state on all surfaces. Slight variations in appearance of abutting or adjacent pieces are acceptable. Noticeable variations in the same piece will not be permitted. **NOTE: BELOW TYPICAL SHEEN IS 20% GLOSS. VERIFY WITH MANUFACTURER IF A HIGHER LEVEL OF GLOSS IS REQUIRED.** c. Products: Color and sheen as selected by the Architect. 1) Duracron Series, PPG Industries, Inc. 2.4 ACCESSORIES **NOTE: COORDINATE WITH DRAWINGS FOR LOCATIONS OF WHICH DOORS RECEIVE WHICH TYPES OF HARDWARE, DEVELOP A HARDWARE SET SCHEDULE FOR EACH DOOR.** A. Factory install hardware, except surface mounted hardware. Remove only as required for final door finishing operation, delivery, and installation at the project site. B. Hardware for Sliding/Folding Doors: **NOTE: COORDINATE WITH THE MANUFACTURER FOR ADDITIONAL HARDWARE DESIRED.** 1. Operating Hardware: Sliding hardware system for folding partitions with panel weights of up to 176 pounds. a. Product and Manufacturer: 1) Variofold 80/H Sliding Hardware System, Hawa AG. 2) Centerfold 80/H Sliding Hardware System, Hawa AG. **NOTE: VARIOFOLD HARDWARE SET AS FOLLOWS.** 2. Hardware sets as required in accordance with the application: a. Hawa 19532 Basic set for first two starter panels. b. Hawa 19533 Additional set for every two additional panels added to stack. c. Hawa 15405 Bottom guide channel. d. Hawa 16852 Top Suspension Track - Aluminum-clear anodized. **NOTE: CENTERFOLD HARDWARE SET AS FOLLOWS.** 3. Hardware sets as required per application: a. Hawa 19535 Basic set for first two starter panels. b. Hawa 19536 Additional set for every two additional panels added to stack. c. Hawa 16852 Top Suspension Track - Aluminum-clear anodized. **NOTE: VARIOFOLD/CENTERFOLD COMMON HARDWARE LISTED BELOW. DELETE “4.” BELOW IF A COMMUNICATING PIVOT DOOR IS NOT ADDED TO STACK. PIVOT DOORS ADDED TO THE STACK MUST SWING 180° AND FOLD FLAT AGAINST THE STACK FOR PROPER OPERATION THEREFORE NO PROJECTING HARDWARE SUCH ____________________________________________________________________________ Folding Partitions – 10 22 39 Page 9 PROJECT NAME DATE ____________________________________________________________________________ AS MORTISE LOCK LEVERS, BAR PULLS AND SURFACE MOUNTED DOOR CLOSERS MAY BE SPECIFIED** 4. Pivot door added to stack: a. Hawa 19620 Pivot Door set to Folded Stack. **NOTE: DELETE ALL OF “C” BELOW IF NO COMMUNICATING PIVOT DOOR IS ADDED TO FAR END-OPPOSITE STACK. INDEPENDENT PIVOT DOORS ADDED TO FAR ENDOPPOSITE STACK MAY HAVE TRADITIONAL OPERATING HARDWARE SUCH AS MORTISE LOCKS, BAR PULLS AND DOOR CLOSERS.** C. Independent communicating Swing Door Opposite the Stack: **NOTE: DELETE BELOW IF NO FLOOR CLOSERS. BELOW INCLUDES THE MANUFACTURER’S SPECIAL TOP AND BOTTOM PIVOT REQUIRED FOR THE FLOOR CLOSER** 1. Center Hung Floor Closers: a. Products and Manufacturers: 1) Top Pivot: 16485, Hawa AG. 2) Bottom Pivot for Floor Closer: 13276, Hawa AG. 3) Center Hung, Concealed Floor Closer: BTS80, DORMA Group. **NOTE: DELETE BELOW IF NO LOCKING PIVOT HINGES. NOTE THAT THIS IS A ‘FREE SWINGING’ (NO CLOSER) DOOR.** 2. Center Hung Pivot Hinges: a. Products and Manufacturers: 1) Top Pivot: 16485, Hawa AG. **NOTE: BELOW ARE THREE OPTIONS, CHOOSE ONLY ONE AND DELETE THE OTHER. THE FIRST IS FOR THE VARIOFOLD, THE SECOND FOR THE CENTERFOLD, THE THIRD IS FOR THE PROPRIETARY PK30 CENTER PIVOT. COORDINATE WITH THE MANUFACTURER FOR ADVICE ON CHOICE AND COST DIFFERENCES.** 2) Bottom Pivot: 19516, Hawa AG. 2) Bottom Pivot: 19515, Hawa AG. 2) Bottom Pivot: PK06-1010, PK30 System, LLC. **NOTE: DELETE BELOW OF NO NON-LOCKING PULL HANDLES. BRACKETS INDICATE A CHOICE OF STAINLESS STEEL OR ALUMINUM, AND THE ROCKWOOD PRODUCT IS AN EXAMPLE. ANY GLASS MOUNTED BACK TO BACK PULL HANDLE SUGGESTED BY THE DESIGNER AND APPROVED IN ADVANCE BY PK30 SYSTEM IS ACCEPTABLE, EDIT THE DESCRIPTION AND PRODUCT AS REQUIRED. 3. Non-Locking Pull Handles: 1-1/4 inch diameter [stainless steel] [aluminum] tube 36 inches long with flat ends and back to back concealed mounting. a. Products and Manufacturers: 1) MegaTek Series, RM3301, Rockwood Manufacturing Co. **NOTE: DELETE BELOW IF NO LOCKING PULL HANDLES.** 4. Locking Pull Handles: Locking type pull handle with lock pull handle manufacturer’s matching dust proof strike. a. Products and Manufacturers: ____________________________________________________________________________ 10 22 39 – Folding Partitions Page 10 PROJECT NAME DATE ____________________________________________________________________________ 1) PostMount or GeoMetek Series, Rockwood Manufacturing Co. **NOTE: DELETE BELOW IF NO MORTISE LOCKS** 5. Mortise Locks: Sliding partition manufacturer’s recommended mortise locks. a. Products and Manufacturers: **NOTE: THE MANUFACTURER PROVIDES SELECTIONS FROM FSB. REFER TO THE FSB CATALOG FOR THEIR FULL LINE OF MORTISE LOCKS, LEVER DESIGNS, FUNCTIONS AND FINISHES. ** 1) xxx, FSB USA **NOTE: DELETE BELOW IF NO BOTTOM RAIL DEADLOCKS** 6. Bottom Rail Deadlocks: a. Products and Manufacturers: 1) PK04-3010 Bottom Rail Lock, Key x Thumb-turn Cylinder into dust-proof floor strike. 2.5 HARDWARE SET SCHEDULE **NOTE: THERE ARE VARIOUS WAYS TO FORMAT A HARDWARE SET SCHEDULE, THE FOLLOWING IS JUST AN EXAMPLE AND NEEDS TO HAVE THE SET NUMBER INCLUDED IN THE DOOR SCHEDULE ON THE DRAWINGS. ALSO, THIS IS AN EXAMPLE USING ONLY GENERIC NAMES FOR ITEMS, THE SPECIFIER SHOULD INCLUDE MORE SPECIFIC INFORMATION.** Set No. Quantity Item Finish **NOTE: IN THE EXAMPLES BELOW, THE ** UNDER THE FINISH COLUMN SHOULD BE REPLACED BY THE FINISH DESIGNATION.** **NOTE: FOLDING PARTITION EXAMPLE.** 101 1 set Folding Partition, operating hardware ** 1 Communicating Door Opposite Stack hardware set ** **NOTE: SWINGING DOOR EXAMPLE.** 100 1 set Floor closers, center hung, single acting, heavy duty, with recessed dress plates, extended spindles, less exposed alignment screws, and no holdopen 2 Non-locking pull handles ** ** PART 3 – EXECUTION 3.1 EXAMINATION A. Verification of Conditions: ____________________________________________________________________________ Folding Partitions – 10 22 39 Page 11 PROJECT NAME DATE ____________________________________________________________________________ 1. Condition of Substrate: Examine the substrates and the conditions under which the work is to be performed. Notify the Architect and do not proceed until unsatisfactory conditions have been corrected. a. Coordinate with the General Contractor as required to obtain verification that adequate support has been provided by the installers of the substrates providing anchorage for the system. b. Verify that other trades have completed the necessary related work before installing the sliding hardware track. c. Verify that floor and mounting surfaces shall be level, plumb, secure, true and straight with not less than 1/8 inch in a 10 foot run in any direction. Substrates shall be of proper dimensions and material. 3.2 PREPARATION A. Templates and diagrams: Furnish templates, diagrams, and other data to fabricators and installers of related work, as necessary, for coordination of the adjacent finishes. 3.3 INSTALLATION A. Install complete system in accordance with manufacturer’s recommendations and written installation instructions. B. Provide appropriate anchorage devices to securely and rigidly fit frames into place, absolutely level, straight, plumb and square. Install frames in proper elevation, plane and location, and in proper alignment other work. 1. Installation Tolerance: Install each demountable partition so surfaces vary not more than 1/8 inch from the plane formed by the faces of adjacent partitions. C. Install frame components in the longest possible lengths, components up to 72 inches shall be single lengths unless otherwise permitted by the Architect. 1. Anchor to the required structural support with anchorage type and spacing as recommended by the manufacturer. 2. Use concealed installation fasteners to produce tightly fitted and aligned splices and connections. **NOTE: BELOW EXPOSED FASTENERS ARE MINIMAL. THE DESIGNER IS ENCOURAGED TO FAMILIARIZE THEMSELVES WITH THEIR LOCATION BY CONTACTING PK30 SYSTEM.** 3. Do not leave installation screws or other fasteners exposed to view when installation is complete, except where required by the manufacturer. D. Clean track and hardware surfaces prior to hanging sliding door panels. ____________________________________________________________________________ 10 22 39 – Folding Partitions Page 12 PROJECT NAME DATE ____________________________________________________________________________ E. Install panels, handles, locks, decorative hardware and trim in accordance with sliding partition manufacturer’s and component manufacturer's recommendations and installation instructions for each item. 1. Adjust system as required at the ceiling and at the floor to accommodate out of level conditions. 3.4 SITE QUALITY CONTROL A. Non-Conforming Work: Do not install components and accessories damaged during shipping and storage. Remove damaged materials from the site and return them to the manufacturer for replacement. 3.5 ADJUSTING A. After repeated operation of installed units, adjust all moveable and operating components as required to provide smooth and continuous long term operation and safety. Any repairs or replacement of components shall be performed as required to comply with the sliding partition manufacturer’s requirements for new installations. 3.6 CLEANING A. Remove temporary coverings and protection only when recommended by the sliding partition manufacturer. Remove construction debris from project site and legally dispose of debris. B. Clean exposed framing and glass surfaces promptly after installation, using cleaning only methods recommended by sliding partition manufacturer. 3.7 CLOSEOUT ACTIVITIES A. Demonstration and Training.: Provide demonstrate and training to the Owner's personnel to adjust, operate, and maintain the system and accessories partitions. Demonstration shall be by a representative approved by the manufacturer of the folding partitions. Refer to Division 01 for additional requirements. 3.8 PROTECTION A. Provide protective measures throughout the remainder of the construction period to ensure that sliding partition system shall be without damage or deterioration at the time of substantial completion. Remove and replace all components damaged. END OF SECTION ____________________________________________________________________________ Folding Partitions – 10 22 39 Page 13
© Copyright 2026 Paperzz