Intelligence IR high speed dome camera

WARNINGS AND CAUTIONS
WARNING
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS
PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS
THROUGH VENTILATION GRILLS OR OPENINGS ON THE EQUIPMENT.
CAUTION
EXPLANATION OF GRAPHICAL SYMBOLS
The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to
alert the user the presence of non-insulated “dangerous voltage” within the product’s
enclosure that maybe of sufficient magnitude to constitute a risk of electric shock to
different persons.
The exclamation point within an equilateral triangle, is intended to alert the user the
presence of important operating and maintenance (servicing) instructions in the
literature accompanying this product
PRECAUTIONS:
1. Persons without technical qualifications should not attempt to operate this dome device before
reading this manual thoroughly.
2. Remove any power to the dome before attempting any operations or adjustments inside the
dome cover to avoid potential damage to the mechanism.
3. Inside the dome cover there are precision optical and electrical devices. Heavy pressure,
shock and other sudden adjustments or operations should be avoided. Otherwise, you may
cause irreparable damage to the product.
4. Please DO NOT remove or disassemble any internal parts of the video camera to avoid
normal operation and possibly void the warranty. There are no serviceable parts inside the
camera.
5. All electrical connections to the dome should be made in strict accordance with the attached
labels and wiring instructions in this manual. Failure to do so may damage the dome beyond
repair and void the warranty.
6. For outdoor installation especially in high places or poles, it is highly recommended that the
proper lightning arrestors and surge suppressors are installed before the dome is entered into
service.
7. Please do not use the product under circumstances where the limits exceed the maximum
specified temperature, humidity or power supply specifications.
IMPORTANT SAFEGUARDS
1. Read these instructions before attempting installation or operation of dome device
2. Keep these instructions for future reference
3. Heed all warnings and adhere to electrical specifications Follow all instructions
4. Clean only with non abrasive dry cotton cloth, lint free and approved acrylic cleaners
5. Should the lens of the camera become dirty, use special lens cleaning cloth and solution to
properly clean it.
6. Do not block any ventilation openings. Install in accordance with manufacturer’s instructions
7. Use only attachments or accessories specified by the manufacturer
8. Verify that the surface you are planning to use for attaching the dome can adequately support
the weight of the device and mounting hardware
9. Protect this devices against lighting storms with proper power supplies
10. Refer all servicing to qualified service personnel. Servicing is required when the device has
been damaged in any way, when liquid traces are present, or the presence of loose objects is
evident or if the device does not function properly, or has received sever impact or has been
dropped accidentally.
11. Indoor dome is for indoor use only and not suitable for outdoor or high humidity locations.
Do not use this product under circumstances exceeding specified temperature and humidity
ratings.
12. Avoid pointing the camera directly to the sun or other extremely bright objects for
prolonged period of time avoiding the risk of permanent damages to the imaging sensor.
13. The attached instructions are for use by qualified personnel only. To reduce the risks of
electric shock do not perform any servicing other than contained in the operating instructions
unless you are qualified to do so.
14. During usage, user should abide by all electrical safety standards and adhere to electrical
specifications for the operation of the dome. The control cable for RS485 communications as
well as the video signal cables should be isolated from high voltage equipment and or high
voltage cables.
15. Use supplied power supply transformer only.
INDEX
1 Product Introduction .......................................................................................................... 1
1.1 Specification................................................................................................................... 1
1.2 Function Description ...................................................................................................... 2
2 Installation ......................................................................................................................... 3
2.1. Wall Mounted Bracket ................................................................................................... 3
3. Operation Instruction........................................................................................................ 4
3.1 Basic Function ............................................................................................................... 4
3.2 Special Function ............................................................................................................ 4
4 OSD Menu ........................................................................................................................ 6
4.1 Menu Index .................................................................................................................... 6
4.2 System Information ........................................................................................................ 7
4.3 Dome ............................................................................................................................. 7
4.3.1 Communication ............................................................................................. 7
4.3.2 IR Display ..................................................................................................... 8
4.3.3 Guard Tours .................................................................................................. 9
4.3.4 A-B Scan..................................................................................................... 10
4.3.5 Pan Scan .................................................................................................... 11
4.3.6 Park Action ................................................................................................. 11
4.3.7 Privacy Zone ............................................................................................... 12
4.3.8 Advanced .................................................................................................... 12
4.4 Camera ........................................................................................................................ 13
4.5 Language ..................................................................................................................... 13
4.6 Display ......................................................................................................................... 14
4.7 Reset ........................................................................................................................... 14
Appendix Ⅰ Anti-lightning, Anti-surge .............................................................................. 15
Appendix Ⅱ Clean Transparent Cover ............................................................................. 15
Appendix Ⅲ Common Knowledge on RS-485 Bus .......................................................... 16
1. Basic Feature of RS-485bus .......................................................................................... 16
2. Mode of Connection and Terminal Resistance ............................................................... 16
AppendixⅣ Exception Handling ........................................................................................ 17
Copyright Statement .......................................................................................................... 18
1 Product Introduction
1.1 Specification
Horizontal Rotation Speed
0-30°/s
Horizontal Rotation Range
0-160°
Tilt Rotation Range
-45 to +25°/s
(manually)
Auto control IR LED
PWM
A-B Scan
0-160°
A-B Scan Speed
01-64speed setting available
Preset Points
220
Go to Preset Speed
200°/s
Guard Tours
3 groups
Guard Points
Max.16 points, dwell time user selectable
Communication
RS485 Bus
Operating Temperature
-15℃~+60℃
Heater & Blower
Auto temperature control
Power
DC12V 2A
≤ 10W
Power Consumption
Coaxial control
Support
1
1.2 Function Description

Coaxial control
Through BNC cable to control PTZ and no need use the ID address and RS485 to distinguish
cameras.

English OSD menu
The language display on screen menu, the available language is English. User can set PTZ
function and specification by menu. Also including the corresponding PTZ information and
state.

IR Output Power Consumption
IR output power consumption can be set through the OSD after IR is turned on.

IR Detection Time
Time duration switching from Color to B/W or B/W to Color.

Focus
The auto focus enables the camera to focus automatically to maintain clear image. User can
use manual focus to in special condition.
Under the following conditions camera will not auto focus on the camera target:
(1) Target is not the center of the screen;
(2) Attempting to view images that are far and near at the same time;
(3) Target is strongly lighted object, such as neon lamp, etc.;.
(4) Targets are behind the glass covered with water droplets or dust;
(5) Targets are moving quickly;
(6) Monotonous large area targets, such as wall;
(7) Targets are too dark or faint.

BLC
If a bright backlight is present, the target in the picture may appear dark or as a silhouette, BLC
enhance the target in the center of the picture, the dome uses the center of the pictures to
adjust the iris. if there is a bright light source outside this area, it will wash out to white, the
camera will adjust the iris so that the target in the sensitive area will properly exposed.

Iris Control
Factory default is automatic camera aperture, in mode of which camera senses changes in
ambient light through moving and adjust automatically lens aperture to make the brightness of
output image stable.
Users can through pressing OPEN or CLOSE iris adjusting keys, manually adjust the aperture
size to get the required picture brightness.
By controlling the keyboard up, down, left, right or zoom to resume auto iris (auto iris is
recommended).

Day/Night Switch
With auto day/night switch function, when the illumination is low the picture will auto switch from
2
day to night mode and when the illumination is high enough the picture will auto switch from
night to day mode

Ratio Speed
Intelligent pan and tilt speed is variable depend on the zoom factor. When zooming in, the
speed will become slower and when zooming out, the speed will become quicker.

A-B Scan
Dome circularly scan close-up real-time scene according to A-B points at setting speed in both
horizontal and vertical directions.

Pan Scan
Dome 360°clockwise continuous scan the display scene at setting speed in horizontal direction
under the condition that pitch angle remains the same.

Preset
After the dome camera keeps arbitrary PTZ location, it will automatically move to the defined
position when preset is called.

Guard Tour
Dome patrol scans according to certain edited preset order.

Power Off Memory
This feature allows the dome to resume its previous preset or status after power is restored. By
default setting, the dome support power up memory, which improves the reliability and avoids
repeated settings of the parameter.

Park Action
If users don’t operate the dome in set time, it will automatically run preset specific mode (pan
scan, A-B scan, park action, cruise, preserve action etc.).
2 Installation
2.1. Wall Mounted Bracket
3
Fig. 2.1.1.1
3. Operation Instruction
3.1 Basic Function

Zoom
Press ZOOM- button to make the lens farther and minify the scene.
Press ZOOM+ button to make the lens closer and magnify the scene.

Focus
After FOCUS- button is pressed, the object in vicinity will become clearer while the object far
away will become ambiguous.
After FOCUS+ button is pressed, the object far away will become clearer while the object in
vicinity will be ambiguous.

Iris
Press IRIS- to gradually shrink the iris and decrease the image brightness.
Press IRIS+ to enlarge the iris and increase the image brightness.

Preset Point
Setting preset press button “preset”+”number”+”enter”.
Calling preset press button “call”+”number”+”enter”.
Deleting preset press button “clear”+”number”+”enter”.
Remark: Some preset points are used tentatively for special functions.
3.2 Special Function
The follow presets are predefined as special function, please shot+ preset No+ enter to enable
those functions:
4
PREST
FUNCTION
PRESET
FUNCTION
34
Reset
92
A-B scan
81
Auto day/night
94
OSD off
82
Switch to night
95
OSD on
83
Switch to day
96
Guard tour 3
86
BLC on
97
Guard tour 2
87
BLC off
98
Guard tour 1
Remark: A-B scan preset default is that preset “1” as A point , preset “2” as B point .
5
4 OSD Menu
4.1 Menu Index
6
4.2 System Information
<SYSTEM>
MFG
CAMERA
SONY-9600-1
PROTOCOL
PELCOD-P
DOME ID
001
COMM
2400.N.8.1
VERSION
EXIT
Fig. 4.2.1
MFG:Max 15 characters display on the screen.
CAMERA: Camera module protocol.
PROTOCOL:Display the protocol of the dome.
DOME ID:Display the dome address.
COMM: Form: Baud rate. Check bit. Data bit. Start bit.
VERSION: Version will update along with the product upgrading.
Remark: Protocol, ID and COMM all can be set in menu <COMM>.
4.3 Dome
4.3.1 Communication
<COMM>
DEVICE ID
CHECK ID
0000
TARGET ID
001
SOFT PROTOCOL
BAUD RATE
AUTO
2400BPS
<COMM RESET>
SAVE
EXIT
7
Fig.4.3.1.1
DEVICE ID
It is only and used to distinct from the ID of other domes.
CHECK ID
Distinguishing several domes with same ID and altering target ID, soft protocol and baud rate
need to enter check ID in line with the device ID, otherwise altering can’t be completed.
TARGET ID
Target ID is available from 001 to 250.
SOFT PROTOCOL
Soft protocol is auto, Pelco-D and Pelco-P available
BAUD RATE
1200BPS、2400BPS、4800BPS、9600BPS available
SAVE
Please save the change of communication. After saving, the dome will reboot.
COMM RESET
Dome save data and reboot .
4.3.2 IR Display
<IR DISPLAY>
WORKING MODE
AUTO
TESTING TIME
08S
OUTPUT POWER
100%
ILLUMINATION ON
3
AMBIENT LIGHT
IR SWITCH ZOOM
01
EXIT
Fig.4.3.2.1
WORKING MODE
Working mode has auto, black/white, color selectable. Default is auto.
TESTING TIME
On IR auto working mode and the programmed time, the IR will execute the programmed action,
eg. Switch from day to night or from night to day. The detection time is from 2s to 15s
selectable.
8
OUTPUT POWER
IR output consumption has 40%、60%、80%、100% selectable.
ILLUMINATION ON
Illumination on is 1 to15 grade selectable and default is 3. On the auto IR working mode, if the
illumination on level is less than the ambient light, the picture will change to color, the IR
illumination will turn off automatically. If the illumination on level is more than the ambient light,
the picture will change to black , the IR illumination will turn on automatically.
AMBIENT LIGHT
Ambient light is a system data. User can not change it manually. It changes according to the
environment all the time. The data will refresh every time when user enter the OSD. It is from 0
to 50 grade.
IR SWITCH ZOOM
IR switch zoom is 1 grade selectable.
.
4.3.3 Guard Tours
<GUARD TOURS>
GUARD TOUR
<GUARD TOUR 01>
01
ID POINT
TIME(S)
SPEED
<SETTING>
1
01
06
64
INIT
2
02
06
64
CALL
3
03
06
64
DELETE
4
04
06
64
5
05
06
64
6
06
06
64
7
07
06
64
8
08
06
64
EXIT
Fig.4.3.3.1
EXIT
Fig.4.3.3.2
GUARD TOUR
Total 3 guard tours selectable: 01, 02, 03.
SETTING
Each guard tour includes max 16 presets. The number of the preset is from 0-64. 0 is not valid,
dwell time is 1 to 60s selectable. Speed is 1 to 64 grade selectable.
INIT
After init., preset point, dwell time, speed will resume to default setting.
9
CALL
Call the new setting.
DELETE
Delete the guard tour set. After deleting, the present preset points all display as 0. While the
exact preset point information doesn’t be deleted. So it is convenient for user to select the
preset point needing to be guarded tour.
4.3.4 A-B Scan
<A-B SCAN>
PRESET A
01
PRESET B
02
SCAN SPEED
05
DWELL TIME
06S
CALL
EXIT
Fig. 4.3.4.1
Fig.4.3.4.1
PRESET A
On A-B scan, A point can be preset from 0 to 64.
PRESET B
On A-B scan, B point can be preset from 0 to 64.
SCAN SPEED
A-B scan speed is 1 to 64 grade selectable.
DWELL TIME
Dwell time between A to B is 2s to 60s selectable.
CALL
Call the new setting.
10
4.3.5 Pan Scan
<PAN SCAN>
PAN SCAN SPEED
20
INIT
CALL
EXIT
Fig.4.3.5.1
PAN SCAN SPEED
Pan scan speed is 1 to 64 grade selectable.
INIT
Reset the scan speed and tilt degree as default setting.
CALL
Call the new setting.
4.3.6 Park Action
<PARK ACTION>
<PARK ACTION>
PARK MODE
OFF
PARK TIME
01M
<SETTING>
CALL
DELETE
PRESET 1: SAVE
EXIT
PRESET 2: BACK
Fig.4.3.6.1
Fig.4.3.6.2
PARK MODE
Park mode includes OFF, Park action, A-B scan, Pan scan, guard tour01, guard tour02, guard
tour03 and Preserve action.
When park mode is OFF status, the dome doesn’t run park mode.
11
When park mode is PRESERVE ACTION status, it record previous action order(A-B scan, Pan
scan, Guard tour 01, Guard tour 02, Guard tour 03).
Example: Running A-B scan at first, when the action stops unexpectedly, it enters the park
mode to continue to run A-B scan.
PARK TIME
Park time is 01~60 mins selectable.
SETTING
After entering the OSD menu, as 7.4.8.2, move to the desired position and save the settings.
CALL
Call the new setting.
4.3.7 Privacy Zone
Not available .
4.3.8 Advanced
<ADVANCED>
PWR ON ACTION
RATIO SPEED
MEMORY
ON
AUTO FLIP
OFF
<OTHERS>
EXIT
Fig. 4.3.8.1
PWR ON ACTION
Power on action can be set as Memory, A-B scan, Pan scan, Park action, Guard tour 01, Guard
tour 02, Guard tour 03 and No action.
RATIO SPEED
Ratio speed can be set as ON or OFF status.
AUTO FLIP
Does not support this function.
OTHERS
Set other options.
12
4.4 Camera
<CAMERA>
DIGITAL ZOOM
OFF
FOCUS
AUTO
IRIS
AUTO
BLC
OFF
EXIT
Fig.4.4.1
DIGITAL ZOOM
Not available
FOCUS
Focus is auto and manual selectable
IRIS
Iris is auto and manual selectable
BLC
BLC is ON and OFF selectable
Remark: Those functions are available on the present module if it supports those functions .
4.5 Language
<LANGUAGE>
LANGUAGE
ENGLISH
EXIT
Fig.4.5.1
LANGUAGE
Language can be set English. Default settings are English.
13
4.6 Display
<DISPLAY>
P
OFF
ACTION
ON
DOME ID
ON
EXIT
Fig.4.6.1
P
Support , default is not display .
ACTION
On the screen, it displays the current action, such as A-B scan, Call preset, Save preset, Call
park action, Pan scan etc. User can enable or disable it
DOME ID
At the top left corner of screen, it displays the dome ID. User can enable or disable it.
4.7 Reset
<RESET>
<DOME RESTART>
<SYS DATA>
<CAM DATA>
<PRESET>
EXIT
Fig.4.7.1
DOME RESTART: It starts self-test by OSD menu.
SYS DAYA: Making all PTZ data recover the factory default .
CMA DATA: Recovering camera data as default ( remark: it needs camera support).
PRESET: It supports preset reset by sub-menu.
14
Appendix Ⅰ Anti-lightning, Anti-surge
This product is extremely air discharge and lightning protection with TVS tube technology,
which can effectively prevent the transient lightning below voltage 3000V, surge and damages
caused by other types of pulse signals.
However, necessary protective measures should be made in the premise of ensuring
electrical safety for outdoor installation according to the actual situation :
·Signal transmission line must be at least 50 meters far away from the high-voltage
equipment or high voltage cable.
· Try to choose outdoor wiring laid down along the roof line.
· Way of sealed steel pipe buried wiring is used in the area which opened, and steel pipe
units grounded in one point. Overhead wiring is absolutely prohibited.
· In the strong thunderstorms area or areas with high induced voltage (such as high voltage
substations), measure of installation of additional high power lightning protection equipment
and lightning rod must be taken.
· Lightning protection and grounding of outdoor devices and lines must take the
lightning-protection requirements of buildings into consideration, and comply with the related
national standards and industry standards.
· System must be equipotential grounding. Grounding device must meet dual requirements
of anti-interference and electrical safety, and should not be shorted or mixed with the adjacent
lines in the strong power grid. When system is independently grounded, grounding impedance
should be less than 4Ω, and cross-sectional area of grounding conductor must be not less than
25m2.
Appendix Ⅱ Clean Transparent Cover
In order to assure a clear image of dome, the under cover of dome should be cleaned regularly.
● Be careful when cleaning and hold the outer ring of under cover by hands to avoid directly
touching with it. Because the acid sweat of finger membrane may corrode the surface coating
of under cover. Hard tool scratching the under cover may lead to blurring the images of dome
so that affecting image quality.
● Please uses a soft enough dry cloth or other alternatives to wipe internal and external
surface.
● If dirt is serious, user can use a mild detergent. Any senior furniture cleaning products can be
used to clean the under cover.
15
Appendix Ⅲ Common Knowledge on RS-485 Bus
1. Basic Feature of RS-485bus
According to industry bus standard of RS-485, RS-485 bus is half-duplex communication bus
with the characteristic impedance of 120Ω, whose maximum load capacity is 32 payloads
(including the master device and the controlled device).
2. Mode of Connection and Terminal Resistance
2.1 Industry standard of RS485 bus requires that connection mode of daisy chain should be
used between the devices with 120Ω terminal resistances connected at the both ends.
As shown in fig. 26 and fig. 27 is simplified connection, but the distance of part "D" shall not
beyond 7 meters.
Fig 26
2.2
Fig 27
120Ω terminal resistance is connected as shown in fig 27.
120Ω terminal resistance is available in the circuit board and the connection is shown as
following:
When needing to connect 120Ω resistance, toggle the 8th bit of DIP switch SW2 to "ON" . This
way the 120Ω resistance is connected to the circuit.
16
AppendixⅣ Exception Handling
Issue
After power is applied,
there is no motion
(self-test) and no video
image.
Self-test is normal, but
cannot control
Noise after self-testing
Possible Reason
Cable harness is
improperly connected
Solution
Verify that the orientation of the
connector input
Input power voltage is too Verify the voltage of the
low
input power
Power supply is not work
Change a new power supply
Wrong communication
settings
Set the correct protocol, baud rate and
address of dome device
Improper connection of
control cable (polarity)
Verify the polarity of the RS485
connection as per the instruction
manual
Mechanical obstruction
Verify and correct it
Camera module is not Correct
installed correct
Low power
Change the correct power supply
Check the power supply or make sure
the power input is DC 12V
Low power
Image is not stable
Video cable is improperly Verify the contact of the video cable
contact
Image is blurring
Camera is on manual Change to auto focus
focus
The lens is dusted
Clean the lens
Power is too low
Change the DC 12V Power supply
Communication distance
Make sure the distance is in the allowed
range
is too long
Control to the camera is
not smooth
RS485 cable is not properly
Make the RS485 is properly contact
contact
Too many do camera Make sure the connected camera is in
connected
the allowed quantity
17
Copyright Statement
This copyright merely belongs to the manufacturer. Without permission, please don’t plagiarize
or copy the contents of this book in any form or by any means.
The company follows the policy of continuous development. Therefore, the company reserves
the right to modify or improve the products described in this manual without notice.
The content of manual is offered according to the "current state". Unless applicable law
otherwise specified, the company does not make any kind of clear or tacit reassurance about
the accuracy, reliability and contents of this manual. The company reserves the right to revise
or recoup this manual at any time without notice.
18
19