WARNINGS AND CAUTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECTS THROUGH VENTILATION GRILLS OR OPENINGS ON THE EQUIPMENT. CAUTION EXPLANATION OF GRAPHICAL SYMBOLS The lighting flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user the presence of non-insulated “dangerous voltage” within the product’s enclosure that maybe of sufficient magnitude to constitute a risk of electric shock to different persons. The exclamation point within an equilateral triangle, is intended to alert the user the presence of important operating and maintenance (servicing) instructions in the literature accompanying this product PRECAUTIONS: 1. Persons without technical qualifications should not attempt to operate this dome device before reading this manual thoroughly. 2. Remove any power to the dome before attempting any operations or adjustments inside the dome cover to avoid potential damage to the mechanism. 3. Inside the dome cover there are precision optical and electrical devices. Heavy pressure, shock and other sudden adjustments or operations should be avoided. Otherwise, you may cause irreparable damage to the product. 4. Please DO NOT remove or disassemble any internal parts of the video camera to avoid normal operation and possibly void the warranty. There are no serviceable parts inside the camera. 5. All electrical connections to the dome should be made in strict accordance with the attached labels and wiring instructions in this manual. Failure to do so may damage the dome beyond repair and void the warranty. 6. For outdoor installation especially in high places or poles, it is highly recommended that the proper lightning arrestors and surge suppressors are installed before the dome is entered into service. 7. Please do not use the product under circumstances where the limits exceed the maximum specified temperature, humidity or power supply specifications. IMPORTANT SAFEGUARDS 1. Read these instructions before attempting installation or operation of dome device 2. Keep these instructions for future reference 3. Heed all warnings and adhere to electrical specifications Follow all instructions 4. Clean only with non abrasive dry cotton cloth, lint free and approved acrylic cleaners 5. Should the lens of the camera become dirty, use special lens cleaning cloth and solution to properly clean it. 6. Do not block any ventilation openings. Install in accordance with manufacturer’s instructions 7. Use only attachments or accessories specified by the manufacturer 8. Verify that the surface you are planning to use for attaching the dome can adequately support the weight of the device and mounting hardware 9. Protect this devices against lighting storms with proper power supplies 10. Refer all servicing to qualified service personnel. Servicing is required when the device has been damaged in any way, when liquid traces are present, or the presence of loose objects is evident or if the device does not function properly, or has received sever impact or has been dropped accidentally. 11. Indoor dome is for indoor use only and not suitable for outdoor or high humidity locations. Do not use this product under circumstances exceeding specified temperature and humidity ratings. 12. Avoid pointing the camera directly to the sun or other extremely bright objects for prolonged period of time avoiding the risk of permanent damages to the imaging sensor. 13. The attached instructions are for use by qualified personnel only. To reduce the risks of electric shock do not perform any servicing other than contained in the operating instructions unless you are qualified to do so. 14. During usage, user should abide by all electrical safety standards and adhere to electrical specifications for the operation of the dome. The control cable for RS485 communications as well as the video signal cables should be isolated from high voltage equipment and or high voltage cables. 15. Use supplied power supply transformer only. INDEX 1 Product Introduction .......................................................................................................... 1 1.1 Specification................................................................................................................... 1 1.2 Function Description ...................................................................................................... 2 2 Installation ......................................................................................................................... 3 2.1. Wall Mounted Bracket ................................................................................................... 3 3. Operation Instruction........................................................................................................ 4 3.1 Basic Function ............................................................................................................... 4 3.2 Special Function ............................................................................................................ 4 4 OSD Menu ........................................................................................................................ 6 4.1 Menu Index .................................................................................................................... 6 4.2 System Information ........................................................................................................ 7 4.3 Dome ............................................................................................................................. 7 4.3.1 Communication ............................................................................................. 7 4.3.2 IR Display ..................................................................................................... 8 4.3.3 Guard Tours .................................................................................................. 9 4.3.4 A-B Scan..................................................................................................... 10 4.3.5 Pan Scan .................................................................................................... 11 4.3.6 Park Action ................................................................................................. 11 4.3.7 Privacy Zone ............................................................................................... 12 4.3.8 Advanced .................................................................................................... 12 4.4 Camera ........................................................................................................................ 13 4.5 Language ..................................................................................................................... 13 4.6 Display ......................................................................................................................... 14 4.7 Reset ........................................................................................................................... 14 Appendix Ⅰ Anti-lightning, Anti-surge .............................................................................. 15 Appendix Ⅱ Clean Transparent Cover ............................................................................. 15 Appendix Ⅲ Common Knowledge on RS-485 Bus .......................................................... 16 1. Basic Feature of RS-485bus .......................................................................................... 16 2. Mode of Connection and Terminal Resistance ............................................................... 16 AppendixⅣ Exception Handling ........................................................................................ 17 Copyright Statement .......................................................................................................... 18 1 Product Introduction 1.1 Specification Horizontal Rotation Speed 0-30°/s Horizontal Rotation Range 0-160° Tilt Rotation Range -45 to +25°/s (manually) Auto control IR LED PWM A-B Scan 0-160° A-B Scan Speed 01-64speed setting available Preset Points 220 Go to Preset Speed 200°/s Guard Tours 3 groups Guard Points Max.16 points, dwell time user selectable Communication RS485 Bus Operating Temperature -15℃~+60℃ Heater & Blower Auto temperature control Power DC12V 2A ≤ 10W Power Consumption Coaxial control Support 1 1.2 Function Description Coaxial control Through BNC cable to control PTZ and no need use the ID address and RS485 to distinguish cameras. English OSD menu The language display on screen menu, the available language is English. User can set PTZ function and specification by menu. Also including the corresponding PTZ information and state. IR Output Power Consumption IR output power consumption can be set through the OSD after IR is turned on. IR Detection Time Time duration switching from Color to B/W or B/W to Color. Focus The auto focus enables the camera to focus automatically to maintain clear image. User can use manual focus to in special condition. Under the following conditions camera will not auto focus on the camera target: (1) Target is not the center of the screen; (2) Attempting to view images that are far and near at the same time; (3) Target is strongly lighted object, such as neon lamp, etc.;. (4) Targets are behind the glass covered with water droplets or dust; (5) Targets are moving quickly; (6) Monotonous large area targets, such as wall; (7) Targets are too dark or faint. BLC If a bright backlight is present, the target in the picture may appear dark or as a silhouette, BLC enhance the target in the center of the picture, the dome uses the center of the pictures to adjust the iris. if there is a bright light source outside this area, it will wash out to white, the camera will adjust the iris so that the target in the sensitive area will properly exposed. Iris Control Factory default is automatic camera aperture, in mode of which camera senses changes in ambient light through moving and adjust automatically lens aperture to make the brightness of output image stable. Users can through pressing OPEN or CLOSE iris adjusting keys, manually adjust the aperture size to get the required picture brightness. By controlling the keyboard up, down, left, right or zoom to resume auto iris (auto iris is recommended). Day/Night Switch With auto day/night switch function, when the illumination is low the picture will auto switch from 2 day to night mode and when the illumination is high enough the picture will auto switch from night to day mode Ratio Speed Intelligent pan and tilt speed is variable depend on the zoom factor. When zooming in, the speed will become slower and when zooming out, the speed will become quicker. A-B Scan Dome circularly scan close-up real-time scene according to A-B points at setting speed in both horizontal and vertical directions. Pan Scan Dome 360°clockwise continuous scan the display scene at setting speed in horizontal direction under the condition that pitch angle remains the same. Preset After the dome camera keeps arbitrary PTZ location, it will automatically move to the defined position when preset is called. Guard Tour Dome patrol scans according to certain edited preset order. Power Off Memory This feature allows the dome to resume its previous preset or status after power is restored. By default setting, the dome support power up memory, which improves the reliability and avoids repeated settings of the parameter. Park Action If users don’t operate the dome in set time, it will automatically run preset specific mode (pan scan, A-B scan, park action, cruise, preserve action etc.). 2 Installation 2.1. Wall Mounted Bracket 3 Fig. 2.1.1.1 3. Operation Instruction 3.1 Basic Function Zoom Press ZOOM- button to make the lens farther and minify the scene. Press ZOOM+ button to make the lens closer and magnify the scene. Focus After FOCUS- button is pressed, the object in vicinity will become clearer while the object far away will become ambiguous. After FOCUS+ button is pressed, the object far away will become clearer while the object in vicinity will be ambiguous. Iris Press IRIS- to gradually shrink the iris and decrease the image brightness. Press IRIS+ to enlarge the iris and increase the image brightness. Preset Point Setting preset press button “preset”+”number”+”enter”. Calling preset press button “call”+”number”+”enter”. Deleting preset press button “clear”+”number”+”enter”. Remark: Some preset points are used tentatively for special functions. 3.2 Special Function The follow presets are predefined as special function, please shot+ preset No+ enter to enable those functions: 4 PREST FUNCTION PRESET FUNCTION 34 Reset 92 A-B scan 81 Auto day/night 94 OSD off 82 Switch to night 95 OSD on 83 Switch to day 96 Guard tour 3 86 BLC on 97 Guard tour 2 87 BLC off 98 Guard tour 1 Remark: A-B scan preset default is that preset “1” as A point , preset “2” as B point . 5 4 OSD Menu 4.1 Menu Index 6 4.2 System Information <SYSTEM> MFG CAMERA SONY-9600-1 PROTOCOL PELCOD-P DOME ID 001 COMM 2400.N.8.1 VERSION EXIT Fig. 4.2.1 MFG:Max 15 characters display on the screen. CAMERA: Camera module protocol. PROTOCOL:Display the protocol of the dome. DOME ID:Display the dome address. COMM: Form: Baud rate. Check bit. Data bit. Start bit. VERSION: Version will update along with the product upgrading. Remark: Protocol, ID and COMM all can be set in menu <COMM>. 4.3 Dome 4.3.1 Communication <COMM> DEVICE ID CHECK ID 0000 TARGET ID 001 SOFT PROTOCOL BAUD RATE AUTO 2400BPS <COMM RESET> SAVE EXIT 7 Fig.4.3.1.1 DEVICE ID It is only and used to distinct from the ID of other domes. CHECK ID Distinguishing several domes with same ID and altering target ID, soft protocol and baud rate need to enter check ID in line with the device ID, otherwise altering can’t be completed. TARGET ID Target ID is available from 001 to 250. SOFT PROTOCOL Soft protocol is auto, Pelco-D and Pelco-P available BAUD RATE 1200BPS、2400BPS、4800BPS、9600BPS available SAVE Please save the change of communication. After saving, the dome will reboot. COMM RESET Dome save data and reboot . 4.3.2 IR Display <IR DISPLAY> WORKING MODE AUTO TESTING TIME 08S OUTPUT POWER 100% ILLUMINATION ON 3 AMBIENT LIGHT IR SWITCH ZOOM 01 EXIT Fig.4.3.2.1 WORKING MODE Working mode has auto, black/white, color selectable. Default is auto. TESTING TIME On IR auto working mode and the programmed time, the IR will execute the programmed action, eg. Switch from day to night or from night to day. The detection time is from 2s to 15s selectable. 8 OUTPUT POWER IR output consumption has 40%、60%、80%、100% selectable. ILLUMINATION ON Illumination on is 1 to15 grade selectable and default is 3. On the auto IR working mode, if the illumination on level is less than the ambient light, the picture will change to color, the IR illumination will turn off automatically. If the illumination on level is more than the ambient light, the picture will change to black , the IR illumination will turn on automatically. AMBIENT LIGHT Ambient light is a system data. User can not change it manually. It changes according to the environment all the time. The data will refresh every time when user enter the OSD. It is from 0 to 50 grade. IR SWITCH ZOOM IR switch zoom is 1 grade selectable. . 4.3.3 Guard Tours <GUARD TOURS> GUARD TOUR <GUARD TOUR 01> 01 ID POINT TIME(S) SPEED <SETTING> 1 01 06 64 INIT 2 02 06 64 CALL 3 03 06 64 DELETE 4 04 06 64 5 05 06 64 6 06 06 64 7 07 06 64 8 08 06 64 EXIT Fig.4.3.3.1 EXIT Fig.4.3.3.2 GUARD TOUR Total 3 guard tours selectable: 01, 02, 03. SETTING Each guard tour includes max 16 presets. The number of the preset is from 0-64. 0 is not valid, dwell time is 1 to 60s selectable. Speed is 1 to 64 grade selectable. INIT After init., preset point, dwell time, speed will resume to default setting. 9 CALL Call the new setting. DELETE Delete the guard tour set. After deleting, the present preset points all display as 0. While the exact preset point information doesn’t be deleted. So it is convenient for user to select the preset point needing to be guarded tour. 4.3.4 A-B Scan <A-B SCAN> PRESET A 01 PRESET B 02 SCAN SPEED 05 DWELL TIME 06S CALL EXIT Fig. 4.3.4.1 Fig.4.3.4.1 PRESET A On A-B scan, A point can be preset from 0 to 64. PRESET B On A-B scan, B point can be preset from 0 to 64. SCAN SPEED A-B scan speed is 1 to 64 grade selectable. DWELL TIME Dwell time between A to B is 2s to 60s selectable. CALL Call the new setting. 10 4.3.5 Pan Scan <PAN SCAN> PAN SCAN SPEED 20 INIT CALL EXIT Fig.4.3.5.1 PAN SCAN SPEED Pan scan speed is 1 to 64 grade selectable. INIT Reset the scan speed and tilt degree as default setting. CALL Call the new setting. 4.3.6 Park Action <PARK ACTION> <PARK ACTION> PARK MODE OFF PARK TIME 01M <SETTING> CALL DELETE PRESET 1: SAVE EXIT PRESET 2: BACK Fig.4.3.6.1 Fig.4.3.6.2 PARK MODE Park mode includes OFF, Park action, A-B scan, Pan scan, guard tour01, guard tour02, guard tour03 and Preserve action. When park mode is OFF status, the dome doesn’t run park mode. 11 When park mode is PRESERVE ACTION status, it record previous action order(A-B scan, Pan scan, Guard tour 01, Guard tour 02, Guard tour 03). Example: Running A-B scan at first, when the action stops unexpectedly, it enters the park mode to continue to run A-B scan. PARK TIME Park time is 01~60 mins selectable. SETTING After entering the OSD menu, as 7.4.8.2, move to the desired position and save the settings. CALL Call the new setting. 4.3.7 Privacy Zone Not available . 4.3.8 Advanced <ADVANCED> PWR ON ACTION RATIO SPEED MEMORY ON AUTO FLIP OFF <OTHERS> EXIT Fig. 4.3.8.1 PWR ON ACTION Power on action can be set as Memory, A-B scan, Pan scan, Park action, Guard tour 01, Guard tour 02, Guard tour 03 and No action. RATIO SPEED Ratio speed can be set as ON or OFF status. AUTO FLIP Does not support this function. OTHERS Set other options. 12 4.4 Camera <CAMERA> DIGITAL ZOOM OFF FOCUS AUTO IRIS AUTO BLC OFF EXIT Fig.4.4.1 DIGITAL ZOOM Not available FOCUS Focus is auto and manual selectable IRIS Iris is auto and manual selectable BLC BLC is ON and OFF selectable Remark: Those functions are available on the present module if it supports those functions . 4.5 Language <LANGUAGE> LANGUAGE ENGLISH EXIT Fig.4.5.1 LANGUAGE Language can be set English. Default settings are English. 13 4.6 Display <DISPLAY> P OFF ACTION ON DOME ID ON EXIT Fig.4.6.1 P Support , default is not display . ACTION On the screen, it displays the current action, such as A-B scan, Call preset, Save preset, Call park action, Pan scan etc. User can enable or disable it DOME ID At the top left corner of screen, it displays the dome ID. User can enable or disable it. 4.7 Reset <RESET> <DOME RESTART> <SYS DATA> <CAM DATA> <PRESET> EXIT Fig.4.7.1 DOME RESTART: It starts self-test by OSD menu. SYS DAYA: Making all PTZ data recover the factory default . CMA DATA: Recovering camera data as default ( remark: it needs camera support). PRESET: It supports preset reset by sub-menu. 14 Appendix Ⅰ Anti-lightning, Anti-surge This product is extremely air discharge and lightning protection with TVS tube technology, which can effectively prevent the transient lightning below voltage 3000V, surge and damages caused by other types of pulse signals. However, necessary protective measures should be made in the premise of ensuring electrical safety for outdoor installation according to the actual situation : ·Signal transmission line must be at least 50 meters far away from the high-voltage equipment or high voltage cable. · Try to choose outdoor wiring laid down along the roof line. · Way of sealed steel pipe buried wiring is used in the area which opened, and steel pipe units grounded in one point. Overhead wiring is absolutely prohibited. · In the strong thunderstorms area or areas with high induced voltage (such as high voltage substations), measure of installation of additional high power lightning protection equipment and lightning rod must be taken. · Lightning protection and grounding of outdoor devices and lines must take the lightning-protection requirements of buildings into consideration, and comply with the related national standards and industry standards. · System must be equipotential grounding. Grounding device must meet dual requirements of anti-interference and electrical safety, and should not be shorted or mixed with the adjacent lines in the strong power grid. When system is independently grounded, grounding impedance should be less than 4Ω, and cross-sectional area of grounding conductor must be not less than 25m2. Appendix Ⅱ Clean Transparent Cover In order to assure a clear image of dome, the under cover of dome should be cleaned regularly. ● Be careful when cleaning and hold the outer ring of under cover by hands to avoid directly touching with it. Because the acid sweat of finger membrane may corrode the surface coating of under cover. Hard tool scratching the under cover may lead to blurring the images of dome so that affecting image quality. ● Please uses a soft enough dry cloth or other alternatives to wipe internal and external surface. ● If dirt is serious, user can use a mild detergent. Any senior furniture cleaning products can be used to clean the under cover. 15 Appendix Ⅲ Common Knowledge on RS-485 Bus 1. Basic Feature of RS-485bus According to industry bus standard of RS-485, RS-485 bus is half-duplex communication bus with the characteristic impedance of 120Ω, whose maximum load capacity is 32 payloads (including the master device and the controlled device). 2. Mode of Connection and Terminal Resistance 2.1 Industry standard of RS485 bus requires that connection mode of daisy chain should be used between the devices with 120Ω terminal resistances connected at the both ends. As shown in fig. 26 and fig. 27 is simplified connection, but the distance of part "D" shall not beyond 7 meters. Fig 26 2.2 Fig 27 120Ω terminal resistance is connected as shown in fig 27. 120Ω terminal resistance is available in the circuit board and the connection is shown as following: When needing to connect 120Ω resistance, toggle the 8th bit of DIP switch SW2 to "ON" . This way the 120Ω resistance is connected to the circuit. 16 AppendixⅣ Exception Handling Issue After power is applied, there is no motion (self-test) and no video image. Self-test is normal, but cannot control Noise after self-testing Possible Reason Cable harness is improperly connected Solution Verify that the orientation of the connector input Input power voltage is too Verify the voltage of the low input power Power supply is not work Change a new power supply Wrong communication settings Set the correct protocol, baud rate and address of dome device Improper connection of control cable (polarity) Verify the polarity of the RS485 connection as per the instruction manual Mechanical obstruction Verify and correct it Camera module is not Correct installed correct Low power Change the correct power supply Check the power supply or make sure the power input is DC 12V Low power Image is not stable Video cable is improperly Verify the contact of the video cable contact Image is blurring Camera is on manual Change to auto focus focus The lens is dusted Clean the lens Power is too low Change the DC 12V Power supply Communication distance Make sure the distance is in the allowed range is too long Control to the camera is not smooth RS485 cable is not properly Make the RS485 is properly contact contact Too many do camera Make sure the connected camera is in connected the allowed quantity 17 Copyright Statement This copyright merely belongs to the manufacturer. Without permission, please don’t plagiarize or copy the contents of this book in any form or by any means. The company follows the policy of continuous development. Therefore, the company reserves the right to modify or improve the products described in this manual without notice. The content of manual is offered according to the "current state". Unless applicable law otherwise specified, the company does not make any kind of clear or tacit reassurance about the accuracy, reliability and contents of this manual. The company reserves the right to revise or recoup this manual at any time without notice. 18 19
© Copyright 2026 Paperzz