When powered up the circulating pump runs

QI Number:
Service
Report
227126
RTN Number:
Date:
12/12/16
Vessel Information
Vessel Manufacturer:
Princess
Hull Number:
75Y-022
Vessel Name:
N/A
Vessel Location:
Mayflower, Plymouth
Address:
Notes (Related Case
History):
Contact Information
Company Name:
PR Nautica
Contact Email:[email protected]
Contact Name:
Mike Elliott
Contact Address:
Contact Number:
07912 269110
PR Nautica, Mountbatten, Plymouth, PL99SJ
Service Case Information
Initial Problem & Complaint
When powered up the circulating pump runs immediately and pulses in speed before selecting heat
or cooling. Power in chiller is 230V but pump is 110V. Labour required to attend boat and rectify.
Case Start Date:
12/12/16
Case End Date:
12/12/16
On-board Labour Time
Date: 12/12/16
Hours:
Date:
Hours:
Hours:
Date:
Hours:
Hours:
Date:
Hours:
Hours:
Date:
Hours:
Hours:
TOTAL Hours:
3.00
Travel Time
3.00
Hours:
Hours:
0.75
0.75
QI Number:
Service
Report
227126
RTN Number:
Date:
12/12/16
Serial Numbers
Part
Serial Number
F16 X42865
339334 Scott pump
Varc 48
62299726
Varc 48
62098546
Technician Initial Observation
Pump running on 110V – 60Hz,
Fault traced to Motor wiring, Brown wire on motor should be insulated but this was grounded for 220v -60Hz
system.
Description of Work Performed
Wiring changed and pump run and tested Ok
Parts Used (Installed and/or Replaced)
Service
Report
Part Number
QI Number:
227126
RTN Number:
Date:
12/12/16
Description
Quantity
Conclusions & Notes
Suggestions/Observations for Engineering
Sign Off
Serial Number
QI Number:
Service
Report
227126
RTN Number:
Date:
12/12/16
Signature of Service Technician: Steve Ball
Date: 12/12/16
Signature of Customer:
Date:
Additional Pictures / Documents