signal LEDs lubricating channel bearing housing bearing shaft Continuous Monitoring of vibration and temperature ’Stand Alone’ no PC hardware necessary Easy to Mount on the lubricating hole Combination Option with an automatic lubricator What kind of machines can be monitored? Machines to be monitored by the Easy Check Online should comply with the following requirements: • constant rotational speed, constant load, stable operating conditions • machines have to be in good condition, suitable for unrestricted long-term operation according to ISO 10816 Examples of machines that can be monitored: • carrying air fan of coal power plant • exhauster of a cement mill • agitator in a water treatment plant • absorber pump for a desulphurisation unit • coal mill of a coal power plant • recirculation fan of a homogenisation furnace • … To select the exact mounting position please consider the following aspects: • mounting position should be as close as possible to the critical parts of the machine • allow for good sound propagation • stud mounting technique is the first choice • vertical positioning should be preferred • for mounting the Easy Check Online, the position has to be accessible • environmental temperature at max 85°C / 185°F BA010-98/122004 CONFIGURATION • • alarm limits filter ACTIVATION • Connecting to power supply (10 – 30 V) MOUNTING • • best option: screw joint with the lubricating channel max. moment of torque: 10Nm TEACH IN MODE • • press the push button for about 4 seconds learning of the ‘good condition’ BA010-98/122004 The first step is to remove the casing cover to configure the Easy Check Online. On the circular board you find the DIP switch and the Teach in Button (please refer to the photo on the last page). The Easy Check Online is delivered with a default setting for standard machines. This setting can be changed to adapt the system to monitor a specific machine (please refer to the table on the last page). Connecting to the power supply activates the Easy Check Online. The reference values of the good condition remain stored during interruption of power supply. This means no teach in mode necessary after power interruption. Preferably screw joint with the lubricating hole: With the M8 external screw thread the Easy Check Online can be connected to any M8 tapped hole. The easiest option is to use the lubricating channel in the bearing housing. Please take care in sealing the internal M8 screw thread on top of the Easy Check with a screw plug, lubricating nipple or the flexible tube of the automatic lubricator (e.g. FAG Motion Guard) to avoid contamination of the bearing. Adhesive-bounded joint: An adaptor is affixed to the machine with a special adhesive. The Easy Check Online is then screwed onto the adaptor. Start of the Teach in Mode: 1. Run up the machine and wait until it reaches the regular operating condition. 2. Press the Teach in Button for about 4 sec – until red, yellow and green LED flash once. 3. 10 minutes remain to refit the casing cover. Then the teach in mode starts. Do not mechanically manipulate the Easy Check Online any more! Teach in Mode: • yellow and green LEDs flash in turn • duration of the teach in mode: about 15 minutes • base values (benchmarks) for the good condition are determined End of the Teach in Mode: • The green LED lights up to indicate the regular monitoring mode No new Teach in Mode is needed when: • machine is stopped and started again • power supply has been interrupted for a while • false alarm has been triggered – reset alarm (see 8) MEASURING • compares actual measurements with the ’good condition’ Every 16 seconds a new measurement takes place. The measured values are compared with the base values and the configured alarm levels (for details please refer to the examples on the last page). The LEDs display the actual alarm status. Blink code of the LEDs: • • • • green LED lights up: no alarm – everything is OK yellow LED lights up: pre-alarm of at least one measurement value red LED lights up: main alarm of the acceleration measurement red LED lights up + yellow LED flashes: main alarm of velocity measurement Other combinations of blink codes are possible depending on alarm condition. ALARMS • • exceeding of the alarm limits triggers the LEDs refer to the blink code If over a period of about 5 minutes succeeding measurements exceed the alarm limit, an alarm is triggered. This way false alarm is excluded. A main alarm overrules a pre-alarm and only the code with the red+green or red+yellow combination flashes. Check the LEDs in regular intervals! CHECK • • check regularly more detailed measurements? If the Easy Check Online displays an alarm, please check: • Have the process parameters changed since the teach in mode? e.g. load, speed • Have the mechanical parameters changed? e.g. reconstructions • Is the connection of the Easy Check Online still tight? • Do you need an expert for diagnosis? to step 4 SERVICE • • • replacement of bearing balancing alignment BA010-98/122004 After successful service new basic values have to be determined. Press the Teach in Button again for about 4 sec until all 3 LEDs flash to start the teach in mode. Adjust alarm levels: If alarm levels have been set too low and an alarm is triggered too early, the alarm levels can be readjusted without a new ‘teach in’. First open casing cover, then alter DIP switches, press the Teach in Button < 1sec ! to reset the alarms – 10 min remain to refit the casing cover. Then the regular measuring mode proceeds. S2.3, S2.4: VELOCITY ALARM SETTINGS Set the Alarm Levels The alarm levels are set by the position of the DIP switches which represent relative values (in % of the base value). Examples: Temperature was determined in the teach in mode as 42°C. • DIP-switch S1.3 is OFF, S1.4 is ON (pre-alarm +15°C, main alarm +20°C, see table) A measured temperature of 57°C triggers a pre-alarm (42°C + 15°C), and a measured temperature of 62°C triggers a main alarm (42°C + 20°C). Acceleration was determined in the teach in mode as 100mg. • DIP-switches S2.3 and S2.4 are both ON (pre-alarm 140%, main alarm 200%, see table) With a measured value of 140mg a pre-alarm is triggered, and with a measured value of 200mg a main alarm is triggered. S 2.3 S 2.4 Prealarm ON OFF ON OFF ON ON OFF OFF 140 % 200 % 280 % 400 % Main alarm 200 % 280 % 400 % 560 % Example Mill Pump Fan Large electric motor The grey lines represent the default setting! Light Codes of the LEDs: none: no power supply or defect red yellow green: start of teach in mode green yellow: teach in mode green: monitoring mode yellow: at least one pre-alarm red (flashes): alarm for acceleration red (lights up permanently), yellow (flashes): alarm for velocity red (lights up permanently), green (flashes): alarm for temperature Other combinations are possible. Flashing every 4 seconds 3x yellow : no reference values stored 2x or 3x red : serious defect – call support Technical Data S1.1, S1.2: SETTING TO MONITOR VIBRATION / BEARINGS S1.1 S1.2 fHP Machine OFF OFF ON ON OFF ON OFF ON 20 Hz ------------500 Hz special applications S1.4 ON ON ON OFF OFF OFF Prealarm TREF +5°K TREF +15°K TREF +25°K TREF +35°K -20°C to +85 °C TREF +30°K power supply: 10 - 30 V DC 10 - 24 V AC TREF +40°K housing material: Makrolon safety class: IP65 (according to DIN) dustproof / splash proof mounting: M8 external screw thread with a feedthrough tube connection: M8 internal screw thread to optionally connect an automatic lubricator dimension: 90 mm ∅ x 76 mm weight: 260 g inverse not inverse ALARM CONFIGURATION OF THE OUTPUTS OFF S 1.4 ON temperature (-20°C up to +85°C) ambient temperature: FUNCTION OF OUTPUTS S 1.4 demodulated acceleration of vibration (bearing) HP: 20 Hz/ 500 Hz (selectable), LP: 5 kHz min. rot. speed 100 rpm Main alarm TREF +10°K TREF +20°K starts the configuration mode stops the configuration mode OFF ON vibration velocity (2 Hz to 1 kHz), min. rot. speed 120 rpm 3 LED’s (red, yellow, green) S1.6 CONFIGURATION MODE FOR OUTPUT AND INPUT S 1.3 S 1.3 measurements: alarm: S1.5 ONLY ACTIVATED IN CONFIGURATION MODE ON OFF FAG Easy Check Online I standard > 100 rpm S1.3, S1.4: TEMPERATURE SETTING S1.3 ON OFF type: Prealarm temperature and vibration / main alarm temperature and vibration Main alarm acceleration, velocity and temperature FUNCTION OF INPUT S 1.5 S 1.5 ON OFF Alarm reset / Teach mode starting of a measurement S2.1, S2.2: ACCELERATION ALARM SETTINGS S 2.1 ON OFF ON OFF S 2.2 ON ON OFF OFF BA010-98/122004 Prealarm 140 % 200 % 280 % 400 % Main alarm 200 % 280 % 400 % 560 % Example Mill Pump Fan Large electric motor FAG Industrial Services GmbH Kaiserstraße 100, 52134 Herzogenrath Germany Support Hotline +49 (0) 2407 91 49 99 [email protected] For further information visit our website www.fis-services.com
© Copyright 2026 Paperzz