DIGITAL PRESSURE Explosion-Proof Pressure Transmitter Explosion-proof Differential Pressure Transmitter Mercoid Series 3200G Features • Completely configurable using zero/span buttons (No calibrator required) • Rangeability (100:1) • High accuracy (±0.075%) • Automatic sensor temperature compensation • Fail-mode process function Power Requirements: Output Signal: Electrical Connection: Enclosure Rating: Mercoid Series 3100D Features • Completely configurable using zero/span buttons (No calibrator required) • Rangeability (100:1) • High accuracy (±0.075%) • Automatic sensor temperature compensation • Fail-mode process function • Selectable engineering units 11.9 to 45 VDC 4 to 20 mA / HART* Communication Two 1/2 inch female NPT conduit, screw terminal. NEMA 4X (IP66) and explosion proof for Class I, Div I Groups A, B, C and D. Power Requirements: Output Signal: Electrical Connection: Enclosure Rating: Model Range Max. Pressure psi (kPa) psi (bar) 3200G-1-FM-1-1 -14.5 to 21 (-100 to 150) 58 (4) 3200G-2-FM-1-1-14.5 to 217 (-100 to 1500) 580 (40) 3200G-3-FM-1-1 0 to 725 (0 to 5000) 2000 (138) 3200G-4-FM-1-1 0 to 3600 (0 to 25000) 10000 (690) 11.9 to 45 VDC 4 to 20 mA / HART* Communication Two 1/2 inch female NPT conduit, screw terminal. NEMA 4X (IP66) and explosion proof for Class I, Div I Groups A, B, C and D. For display, add -LCD to model code Model 3100MP-2-FM-1-1 3100MP-3-FM-1-1 3100MP-4-FM-1-1 3100MP-5-FM-1-1 3100MP-6-FM-1-1 Calibrated Span (Min. to Max.) 0.6 to 30 in w.c. 0.15 to 7.5 kPa 1.5 to 150 in w.c. 0.373 to 37.3 kPa 7.5 to 750 in w.c. 1.865 to 186.5 kPa 1 to 100 psi 6.9 to 690 kPa 3 to 300 psi 20.68 to 2068 kPa Lower Range Limit -30 in w.c. -7.5 kPa -150 in w.c. -37.3 kPa -750 in w.c. -186.5 kPa -100 psi -690 kPa -300 psi -2068 kPa Upper Range Limit 30 in w.c. 7.5 kPa 150 in w.c. 37.3 kPa 750 in w.c. 186.5 kPa 100 psi 690 kPa 300 psi 2068 kPa For display, add -LCD to model code DWYER Economical Level Switches Series F7 • Contacts hermetically sealed, compact and reliable Vertical Installation - Standard Models Model Float/Rod Max Temp. Max Pressure Min.S.G. Électrical F7-SB Buna-N & époxy 220°F/105°C 150 psig 0,60 25VA; 1A to 220Vca inox 316 F7-SS2 Inox 316 300°F/149°C 450 psig 0,75 25VA; 1A to 200Vca F7-BT Buna-N & époxy 220°F/105°C 150 psig 0,45 30VA; 0.14A to 220Vca PBT Montage horizontal F6-HPS-11 Polypropylene F6-HPS-21 Polypropylene F6-MHS SS 304 F7-HSS SS 316 FLOTECT® 176°F/80°C 176°F/80°C 257°F/125°C 392°F/200°C Level Switch Series L4 (DWYER) • Magnetic switch, SPDT 5A to 125/250Vca • Leak proof case, explosion proof • Approved UL, CSA, FM, CE, ATEX (optional) • Max 4/275°F (-20/135°C) or option MT up to 400°F (205°C); 1000 psig (brass) or 2000 psig (SS 316), standard float 100 psig (0.7 specific gravity ) • Fitting 1-1/2”npt male • Options: DPDT, gold contacts, high temperature, action delay, ATEX, SAA, vertical installation, floats, etc. Code Description L4 Brass, horizontal installation L4SS SS, horizontal installation L4 116 psig 116 psig 218 psig 300 psig 0,60 0,60 0,85 0,60 FLOTECT® 20VA; 0.08A to 240Vca 20VA; 0.08A to 240Vca 20VA; 0.08A to 240Vca 30VA; 0.14A to 220Vca Level Switch Model L8 (DWYER) • Economical, leak proof case, resistant to chemical products • Approved CE, UL 508 • Max 212°F – 100°C, 150 psig • Fitting ½”npt male (electrical conduit)) and 1”npt male (process) • Switch SPDT 5A to125/250Vac • Float PPS, specific gravity, 0.6 min., SS 316 or Inconel pin and spring, ceramic magnet 8 • Options: Gold (L8-MV), inconel alloy (L8-INC) contacts, airtight case (L8-WP) Code Description L8 Interrupteur à montage horizontal F7-HPS-11 Mount 18”wires No 22, 1/8”npt 18”wires No 22, 1/8”npt 24”wires No 22, 1/8”npt 11,8”wires No 20, threads M16x2 11,8”wires No 20, ½”npt (ext) 11,8”wires No 22, ½” M16 x 2 24”wires No 22, ½”npt (ext/int) FLOTECT® F7-SB Flow Mini-Size Switch Models V10 & V11 (DWYER) • For pipes ½" to 2" (adjustable valve ) • Airtight or waterproof case (V11). Approved: UL, CE, CSA (V10) and UL (V11), ½" npt • Max 93°C - 200°F (V10) and 121°C – 250°F (V11) • Max 1000 psig (brass) or 2000 psig (SS 303) • SPST switch 1.5A to 24Vcc Code Description V10 Brass, adjustable NO or NF V10SS SS 303, adjustable NO or NF L8 w w w. c h e v r i e r i n s t r u m e n t s . c o m 2 0 1 6 Ve r s i o n V10 7
© Copyright 2026 Paperzz