Fire And Emergency Response Firefighter II Copyright and Terms of Service Copyright © Texas Education Agency, 2011. These materials are copyrighted © and trademarked ™ as the property of the Texas Education Agency (TEA) and may not be reproduced without the express written permission of TEA, except under the following conditions: 1) Texas public school districts, charter schools, and Education Service Centers may reproduce and use copies of the Materials and Related Materials for the districts’ and schools’ educational use without obtaining permission from TEA. 2) Residents of the state of Texas may reproduce and use copies of the Materials and Related Materials for individual personal use only, without obtaining written permission of TEA. 3) Any portion reproduced must be reproduced in its entirety and remain unedited, unaltered and unchanged in any way. 4) No monetary charge can be made for the reproduced materials or any document containing them; however, a reasonable charge to cover only the cost of reproduction and distribution may be charged. Private entities or persons located in Texas that are not Texas public school districts, Texas Education Service Centers, or Texas charter schools or any entity, whether public or private, educational or non-educational, located outside the state of Texas MUST obtain written approval from TEA and will be required to enter into a license agreement that may involve the payment of a licensing fee or a royalty. Contact TEA Copyrights with any questions you may have. Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 2 Emergency Incident Response Preparedness – Personnel • Properly trained • Continuing education • Certifications – Equipment • Training equipment must be in good condition • Front line equipment must be in good condition Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 3 Emergency Incident Response (continued) Scene management – Develop effective Incident Action Plans (IAPs) – Establish tactical priorities – Establish clear benchmarks Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 4 Emergency Incident Response (continued) • Benchmarks – Personnel Accountability Report (PAR): all fire service personnel working in the hazard zone are okay and accounted for – “All Clear”: primary search completed, all who could be rescued are clear of the hazard zone – “Under Control”: the fire’s forward progress has been halted, and there is no imminent danger to personnel – “Loss Stopped”: the property conservation tactic is achieved Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 5 Simulated Emergencies/ Live Fire Procedures Establish policies and procedures for Live Fire Training – Live fire/burn exercises should be run in accordance with National Fire Protection Association (NFPA) 1403: Standard on Live Fire Training Evolutions • Site preparation – Clear all potential hazards » Hazardous materials » Structural deficiencies » Utilities » Pests and vermin Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 6 Simulated Emergencies/ Live Fire Procedures (continued) Safety – Student-instructor ratio no less than 5 to 1 – Designated safety officer – Humans cannot be used to simulate fire victims – Fires cannot be set in egress (exit) routes – Personal Protective Equipment (PPE) and uniforms should be in compliance with NFPA standards Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 7 Simulated Emergencies/ Live Fire Procedures (continued) Prerequisite training – participants must have completed a basic firefighter training course/class Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 8 Simulated Emergencies/ Live Fire Procedures (continued) Water supply – Adequate water supply for the size of the structure and the specified training – There must be separate water supplies for attack lines and backup lines Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 9 Simulated Emergencies/ Live Fire Procedures (continued) Training plan – have a developed plan and briefing with training participants Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 10 Simulated Emergencies/ Live Fire Procedures (continued) Fuel – flammable liquids are not allowed in acquired structures or burn buildings not designed for their use Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 11 Simulated Emergencies/ Live Fire Procedures (continued) Ventilation – controlled ventilation is required to prevent flashover and backdraft Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 12 Advancing Dry and Charged Hose Lines Into a structure • Bleed air from the line before entry • All team members should be on the same side of the hose line • Feel/check doors for evidence of heating before entering • Stay low and do not impede ventilation efforts • Chock self-locking doors in an effort to keep lines from being kinked Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 13 Advancing Dry and Charged Hose Lines (continued) Up a stairway • Hose lines should be advanced up stairways while they are uncharged • It’s too difficult to negotiate doorways, stairs, and corners while charged • The shoulder-carry works efficiently because the hose is carried rather than being dragged • The minuteman load works well too • Lay the hose against the outside wall to keep the stairwell clear • Avoid sharp bends and kinks in the hose • Take the excess flaked hose up the stairs above the fire floor Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 14 Advancing Dry and Charged Hose Lines (continued) Down a stairway • It is easier to advance dry lines down stairs than it is charged lines • Advancing uncharged lines downstairs should only occur if there is little (minor) or no fire present • Advancing charged lines down stairs is considerably difficult • • • Excess hose should be flaked outside the stairwell, in a hallway, or room adjacent to the stairwell Firefighters can be positioned to feed the hose forward to the nozzle team Have firefighters at corners and tight areas to help negotiate turns and areas of limited access Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 15 Advancing Dry and Charged Hose Lines (continued) From a Standpipe • Use hose rolls or hotel packs carried to upper floors. Have the necessary fittings and nozzles with you • Connect one floor below the fire in most circumstances. If the standpipe is an enclosed stairwell, it is allowable to connect on the fire floor • At the standpipe connection • • • • • Remove the outlet cap Check for foreign objects Check the connection to determine what adaptor to use if necessary A gated wye may be necessary to reduce the line size desired Any extra hose should be flaked up the stairs towards the floor above Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 16 Advancing Dry and Charged Hose Lines (continued) Advancing an uncharged hose line up a ladder • Advancing a hose up a ladder is much safer and easier with an uncharged line • The firefighter heeling the ladder can assist by feeding line as it is being pulled • Have the first firefighter (FF1) carry the hose draped over his or her shoulder from the front with the nozzle on his or her back Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 17 Advancing Dry and Charged Hose Lines (continued) Advancing an uncharged hose line up a ladder (continued) • FF1 advances to the first fly section and waits until the next firefighter (FF2) is ready to advance • FF2 advances with a large loop draped over his or her shoulder and starts up the ladder (on a three section ladder a third firefighter can continue the process). There should never be more than one firefighter on each section of the ladder • The hose can be charged when it is in place for an attack Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 18 Advancing Dry and Charged Hose Lines (continued) Advancing a charged hose line up a ladder • Firefighters should be positioned on the ladder within reach of each other • They should be attached with a leg lock or secured with a ladder belt • The hose is then pushed up from one firefighter to the next. The firefighter on the nozzle will advance through the window while the others support the hose by securing it to the ladder Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 19 Resources • 0135151112, Essentials of Firefighting (5th Edition), International Fire Service Training Association (IFSTA) • National Fire Protection Association (NFPA) 1403: Standard on Live Fire Training Evolutions http://www.nfpa.org/categoryList.asp?categoryID =124&URL=Codes%20&%20Standards • Images used with permission from IFSTA (Slides 14, 15, 18 and 19). Copyright © Texas Education Agency 2011. All rights reserved. Images and other multimedia content used with permission. 20
© Copyright 2026 Paperzz