Universal solutions for PLC input/ output cards Contents Universal solutions for PLC input/output cards Universal solutions for PLC input/output cards 1327330000 – 2012/2013 Introduction A A.2 ABB S800 – Selection guide A.12 Emerson DeltaV – Selection guide A.13 GeFanuc 90-30 – Selection guide A.14 GeFanuc RX3i – Selection guide A.15 Honeywell C200 – Selection guide A.16 Mitsubishi MELSEC Q – Selection guide A.17 Moeller XIOC – Selection guide A.18 Omron C200H – Selection guide A.19 Omron CJ1W – Selection guide A.20 Omron CQM1 – Selection guide A.21 Rockwell Compact Logix – Selection guide A.22 Rockwell Control Logix – Selection guide A.23 Rockwell Micro Logix 1400 – Selection guide A.24 Rockwell SLC 500 – Selection guide A.25 Schneider M258 – Selection guide A.26 Schneider M340 – Selection guide A.27 Schneider MICRO – Selection guide A.28 Schneider PREMIUM – Selection guide A.29 Schneider QUANTUM – Selection guide A.30 Schneider TWIDO – Selection guide A.31 Siemens S7-200 – Selection guide A.32 Siemens S7-300 / ET- 200M – Selection guide A.33 Siemens S7-400 – Selection guide A.36 Siemens S7-1200 – Selection guide A.37 RS IO – Selection guide for passive interfaces for digital signals A.38 RS IO – Passive interface for digital signals A.40 RS A – Selection guide for passive interfaces for analogue signals A.60 RS A – Passive interface for analogue signals A.61 RSM – Selection guide for insulated interfaces for digital input signals A.66 RSM – Isolated interfaces for digital input signals A.67 RSM – Selection guide for insulated interfaces for digital output signals A.70 RSM – Isolated interfaces for digital output signals A.71 PAC-UNIV universal pre-asembled cables with wire-end ferrules A.82 A.1 Universal solutions for PLC input/ output cards Introduction Universal solutions for PLC input/output cards Aimed at reducing costs, and to save space and time in the construction of electrical cabinets, the universal cabling system for PLCs is provided as an effective alternative to end-to-end cabling design. Weidmüller offers a wide range of pre-assembled cables and interfaces to major PLC manufacturers: A • The interfaces are used as an interconnection element between the control and the process, and are supplied with tension clamp or screw connection. Those interfaces, with a compact design, provide different functions such as LEDs, fuses, disconnectors or relays. • The pre-assembled cables are supplied with the manufacturer’s own connector at one end and are available in different lengths. Universal system The system is designed to be compatible with all main commercial PLCs: ABB, Emerson, Fanuc, Honeywell, Mitsubishi, Omron, Rockwell, Schneider, Siemens, ... Guaranteed connection The original factory connector is on one end of the PLC and standard connectors are on the other end: ribbon cable with fixing housing for digital signals and SUB-D connector for analogue signals. Available in different lengths. A.2 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Introduction Simple system configuration Selection tables are available in this catalogue to assist you in choosing the right products for your application. In addition, there is also an automatic software selection guide on the website. Selection guide PLC Input/Output cards Manufacturer code 6ES7321-1BH00-0AA0 6ES7321-1BH01-0AA0 6ES7321-1BH02-0AA0 6ES7321-1BH50-0AA0 6ES7321-1BH80-0AA0 6ES7321-1BH81-0AA0 6ES7321-1BH82-0AA0 6ES7321-1BL00-0AA0 6ES7321-1BL80-0AA0 6ES7321-1BP00-0AA0 DI DO 6ES7321-1CH20-0AA0 6ES7321-1CH80-0AA0 6ES7321-1EH00-0AA0 6ES7321-1EH01-0AA0 6ES7321-1EL00-0AA0 6ES7321-1FF00-0AA0 6ES7321-1FF01-0AA0 6ES7321-1FF81-0AA0 6ES7321-1FH00-0AA0 6ES7321-7BH00-0AB0 A) 6ES7321-7BH01-0AB0 A) 6ES7321-7BH80-0AB0 A) 6ES7321-7RD00-0AB0 B) 6ES7322-1BF00-0AA0 6ES7322-1BF01-0AA0 6ES7322-1BH00-0AA0 6ES7322-1BH01-0AA0 6ES7322-1BH10-0AA0 6ES7322-1BH81-0AA0 6ES7322-1BL00-0A00 6ES7322-1BP00-0AA0 6ES7322-1BP50-0AA0 C) 6ES7322-1CF00-0AA0 6ES7322-1CF80-0AA0 6ES7322-1EH00-0AA0 6ES7322-1EH01-0AA0 6ES7322-1EL00-0AA0 6ES7322-1FF00-0AA0 6ES7322-1FF01-0AA0 6ES7322-1FF81-0AA0 6ES7322-1FH00-0AA0 6ES7322-1FL00-0AA0 6ES7322-1HF80-0AA0 6ES7322-5RD00-0AB0 D) 6ES7322-5SD00-0AB0 D) 6ES7322-8BF00-0AB0 6ES7322-8BF00-0AB0 6ES7322-8BH01-0AB0 6ES7322-8BH01-0AB0 6ES7323-1BH00-0A00 6ES7323-1BH01-00A0 DI/DO 6ES7323-1BH80-0AA0 6ES7323-1BH80-0A00 6ES7323-1BL00-0AA0 1327330000 – 2012/2013 Number/Type of channels 16 DI 16 DI 16 DI 16 DI 16 DI 16 DI 16 DI 32 DI 32 DI 64 DI, positive logic 64 DI, negative logic A) 16 DI 16 DI 16 DI 16 DI 16 DI 8 DI 8 DI 8 DI 16 DI 16 DI 16 DI 16 DI 16 DI 8 DO 8 DO 16 DO 16 DO 16 DO 16 DO 32 DO 64 DO 64 DO 8 DO 8 DO 16 DO 16 DO 32 DO 8 DO 8 DO 8 DO 16 DO 32 DO 8 DO 4 DO 4 DO 8 DO, without redundancy 8 DO, with redundancy 16 DO, without redundancy 16 DO, with redundancy 8 DI 8DO 8 DI 8 DO 8 DI 8 DO 8 DI 8 DO 16 DI 16 DO Cables Interfaces Standard Order No. 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789236xxx 7789236xxx 7789771xxx 7789768xxx 7789211xxx 7789211xxx 7789212xxx 7789212xxx 7789215xxx 7789219xxx 7789219xxx 7789219xxx 7789212xxx 7789210xxx 7789210xxx 7789210xxx 7789801xxx 7789239xxx 7789239xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789236xxx 7789246xxx 7789246xxx 7789191xxx 7789191xxx 7789211xxx 7789211xxx 7789211xxx 7789219xxx 7789219xxx 7789219xxx 7789211xxx 7789211xxx 7789190xxx 7789192xxx 7789192xxx 7789239xxx 7789830xxx 7789729xxx 7789730xxx 7789237xxx A Universal solutions for PLC input/ output cards PLC SIEMENS – S7-300/ET- 200M Quantity 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 2 1 1 1 1 2 1 1 1 1 1 1 1 1 7789237xxx 1 7789237xxx 1 7789237xxx 1 7789236xxx 1 Direct inputs/outputs Insulated inputs - see page A.38 (H) or A.60 (A) Type Quantity H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 H2016 4 H2016 4 R2416 1 R2416 1 R2416 1 R2416 1 R3632 1 R1208 1 R1208 1 R1208 1 R2416 1 R2416 1 R2416 1 R2416 1 H20 1 H2008 1 H2008 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 4 H2016 4 R1208 1 R1208 1 R2416 1 R2416 1 R2416 2 R1208 1 R1208 1 R1208 1 R2416 1 R2416 2 R2416 1 H2016 1 H2016 1 H2008 1 H2008 1 H2016 1 H2016 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2016 1 H2016 1 - see page A.66 Type Quantity I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 2 I2016 2 I2016 4 Insulated outputs - see page A.70 Type Quantity O2008 O2008 O2016 O2016 O2016 O2016 O2016 O2016 O2016 1 1 1 1 1 1 2 4 4 O2008 O2008 O2016 O2016 1 1 1 1 O2008 I2016 A Wide range of passive interfaces The range includes passive input/output interfaces for digital and analogue signals. The interfaces are available in screw or tension clamp connection and the sensors/actuators can be connected with 1, 2 or 3 wires, whichever is needed. You can also choose from a large variety of functions: •LED indication •Fuse •Circuit Breaker •Test leads 1 O2008 1 O2008 1 O2008 1 O2016 1 1 A.33 Wide range of relay insulated interfaces Available in versions with 8-12 and 16 relays, the RSM family offers the possibility of insulating digital signals both in input and output cards. Options include our compact format (6 mm relays) or standard (RCL relay), with additional features including: •Switch in coil and contact •Fuse in contact •1 or 2 CO contacts 1327330000 – 2012/2013 A.3 Universal solutions for PLC input/ output cards Introduction Universal solutions for PLC input/output cards The increasing complexity of machinery and facilities in the industry means that attention is being drawn to the resulting rise in the costs of wiring. Traditional end-to-end cabling between the PLC and the field components has many drawbacks: A • High assembly costs: Time-consuming routing and assembly of connecting leads. • The risk of wiring mistakes increases in proportion with the number of individual wires at one end. • Individual wires occupy a considerable amount of space in the cabinet. • High installation and implementation time. • High labelling and documentation workload Weidmüller offers a complete line of pre-assembled cables, together with a range of compact interfaces, to connect with the main commercial PLCs: • ABB S88 • Emerson Delta V • Ge Fanuc 90-30 and RX3i • Honeywell C200 • Mitsubishi Melsec • Omron C200, CJ1 and CQM1 • Rockwell Compact Logix , Control Logix, Micro Logix and SLC500 • Schneider Micro, Premium, Twido, Quantum, M340 and M258 • Siemens S7-200,S7-300,S7-400 and S7-1200 A.4 PLC interface The range includes passive input/output interfaces for digital and analogue signals and relay boards to insulate the input and output signals. These modules accept all common commercial connectors and are available for screw or tension clamp connection. The Weidmüller universal interfaces for the PLC have the following individual components: • Extruded profile for inserting the PCB • Clip-on feet for locking on standardised mounting rails TS 32 and TS 35 • Printed circuit board where the following elements can be identified –Plug-in connectors to the PLC (Ribbon cable, RSV or SUB-D) –Weidmüller terminals for screw or tension clamp connection –Electronic or mechanical components offering additional functions: LED, relays, fuses… These interfaces are universal: the same interface can be used by different PLCs from different manufacturers. Pre-assembled cables are responsible for adequately communicating the PLC with its field components. Digital input/output interfaces (H System) The digital input/output interfaces have been designed using a ribbon cable connector suitable for the majority of signals coming from the PLC. In addition, the pre-assembled cables are designed using a cross-section of 0.25 mm2 and have a cover that guarantees complete and safe fastening with the interface connector. 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Introduction The range has been designed for 4, 8,12,16 and 32 signals in tension clamp or screw connection and you can choose additional functions including: 2-wire system: The 2 wires of the field element are connected to the interface with power bus in one of them. • LED • Fusible • Interruptor A 0.0 C Additionally, sensors/actuators can be connected using 1-, 2-, or 3-wire techniques; this way, the space that is usually needed for connecting the common power supply points, which are normally connected via additional terminals, is not required. 0.1 1-wire system: In field components, one of the wires is connected to the interface while the other is connected to a common power supply point (for example a terminal block). 0.7 C C + 0.0 0.1 C + – – 0.7 + + – – 3-wire system: The interface is designed for 3 wire field components, with one for positive, one for negative and one for the signal that is sent to the PLC. + 0.0 – + 0.1 – + 1.7 – + + – 1327330000 – 2012/2013 – A.5 Universal solutions for PLC input/ output cards Introduction Universal solutions for PLC input/output cards Digital input/output interfaces for high voltage (R System) A The digital signals used by PLCs are usually 24V DC or a maximum of 48 V DC. Nevertheless, a few cards also work at higher voltages, up to 230 V AC. For these voltages, the insulation distance between channels has to be increased up to values that the ribbon cable connector is not able provide. In this case, interfaces supplied with RSV connectors have been included in the range. Insulated digital input/output interfaces The insulated digital input/output interfaces are used, when necessary, to isolate the PLC signal from the field signal, normally when adapting voltages between the field components and the PLC operational voltage. The current provided by the PLC is not high enough for the different field components in the output cards. In this case, the relay acts like an amplifier and offers enough power to connect the different elements, such as, for example, electro valves. The RSM family, available in 8,12, and 16 relay versions connects to the PLC with a ribbon cable and is available in compact form (6 mm relays) or standard (RCL relay) and includes additional features such as: • Switch in coil and contact • Fuse in contact • 1 or 2 CO contacts In addition, the relays also can be replaced by the Weidmüller opto modules. ((Prüfen)) Analogue input/output interfaces (S System) A.6 The analogue input/output interfaces have been designed using a shielded SUB-D connector, ideal for avoid interferences in the transmission of analogue signals. The pre-assembled cables are also supplied with shielded cable. 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Introduction Pre-assembled cables The connection using pre-assembled cables drastically reduces the connection work between the PLC and the field components. Table of colour codes according to DIN 47.100 Nº 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Colour White Brown Green Yellow Grey Pink Blue Red Black Violet Grey/Pink Red/Blue White/Green Brown/Green White/Yellow Yellow/Brown White/Grey Grey/Brown White/Pink Pink/Brown White/Blue Nº 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Colour Brown/Blue White/Red Brown/Red White/Black Brown/Black Grey/Green Yellow/Grey Pink/Green Yellow/Pink Green/Blue Yellow/Blue Green/Red Yellow/Red Green/Black Yellow/Black Grey/Blue Pink/Blue Grey/Red Pink/Red Grey/Black Pink/Black Nº 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 Each pre-assembled cable has the following features: Tables and automatic selection guides: • PLC connector: The original connector of the manufacturer is used. • Interface Connector: 3 types of connectors are used according to the interface they connect to. –Ribbon cable connectors - which are supplied with a hood to protect them from cable extraction forces and ensure secure and reliable connection. – Very sturdy RSV connectors that allow working with high voltages of up to 230 V. –SUB-D connectors, where the wire screening for analogue signals is connected directly to the metallic body of the connector to minimise the effect of electromagnetic interferences. • Cable: A multipole 0.25 mm2 cross-section wire is used. This is also shielded for analogue signal cables. Each of the individual wires is identified by means of a colour code according to DIN 47.100. To help you choose the right products for your application, Weidmüller offers a catalogue with a selection of tables which can be found on the following pages. 1327330000 – 2012/2013 A Colour Blue/Black Red/Black White/Brown/Black Yellow/Green/Black Grey/Pink/Black Blue/Red/Black White/Green/Black Green/Brown/Black White/Yellow/Black Yellow/Brown/Black White/Grey/Black Grey/Brown/Black White/Pink/Black Pink/Brown/Black White/Blue/Black Brown/Blue/Black White/Red/Black Brown/Red/Black Black/White In addition, on our website, we have an automatic selection guide, using intuitive software that can help you to choose the appropriate interface cable for your Input/Output cards. This can be found at www.weidmueller.com A.7 Universal solutions for PLC input/ output cards Introduction Universal solutions for PLC input/output cards Advantages of the system: A The combination of pre-assembled cables and the interfaces allows the final connecting system to be: • Safe – It excludes the risk of errors in cabling • Fast The use of pre-assembled cables means there are real savings in time: – during design, thanks to the selection guides. – during assembly. – during startup. – in the detection/resolution of problems. • Reliable – no cabling errors, – clean cabling in cabinet (multi-pole cables instead of single cables) • Flexible – a multitude of input/output interfaces – variable cable lengths, – expansions can be made without any problem. – flexibility thanks to the simplicity of interchanging and diverse input/output interfaces. – easy migration to another system, simply by changing the pre-assembled cable. •Small-space reduction – more space in the cable ducts, – narrow modules, – no terminal block A.8 1327330000 – 2012/2013 A 1327330000 – 2012/2013 A.9 Universal solutions for PLC input/ output cards Universal solutions for PLC input/ output cards Introduction PLC interface selection tables A PLC SIEMENS – S7-300/ET- 200M Universal solutions for PLC input/ output cards Selection guide 4 1 Universal solutions for PLC input/ output cards A.38 Cables Standard Number/Type of channels 16 DI 16 DI 16 DI 16 DI 16 DI 16 DI 16 DI 32 DI 32 DI 64 DI, positive logic 6ES7321-1BP00-0AA0 64 DI, negative logic A) 6ES7321-1CH20-0AA0 16 DI DI 6ES7321-1CH80-0AA0 16 DI Selection guide 6ES7321-1EH00-0AA0 16 DI 6ES7321-1EH01-0AA0 16 DI 6ES7321-1EL00-0AA0 16 DI 6ES7321-1FF00-0AA0 8 DI 6ES7321-1FF01-0AA0 RS IO – Selection guide for passive interfaces 8 DI 6ES7321-1FF81-0AA0 8 DI for digital signals 6ES7321-1FH00-0AA0 16 DI 16 DI 6ES7321-7BH00-0AB0 A) A) Type Features Interfaces 16 DI 6ES7321-7BH01-0AB0 Number of Family Type of wiring Connection LED by channel Disconnectable Fuse Order No. Type Page channels Screw Tension clamp 16 DI 6ES7321-7BH80-0AB0 A) connection B) V L 9445530000 RS 8IO 2W L H S A.40 H2008 2-wire 6ES7321-7RD00-0AB0 16 DI 8-channel V 9441540000 RS 8IO 2W R S A.41 R1208 2-wire 6ES7322-1BF00-0AA0 89445630000 DO V L 12-channel H2012 2-wire RS 12IO 2W L H S A.42 6ES7322-1BF01-0AA0 8 DO V 9445700000 RS 16IO 1W H S A.43 V L 9445710000 RS 16IO 1W L H S A.43 6ES7322-1BH00-0AA0 16 DO Z 1311750000 RS 16IO 1W H Z A.43 1-wire Z 6ES7322-1BH01-0AA0 L 1311770000 RS 16IO 1W L H Z A.43 16 DO V L I 9445810000 RS 16IO 1W I-L H S A.44 Z 6ES7322-1BH10-0AA0 L I 1311780000 RS 16IO 1W I-L H Z A.44 169445720000 DO RS 16IO 2W H S V A.45 V L 9445730000 RS 16IO 2W L H S A.45 6ES7322-1BH81-0AA0 161311790000 DO RS 16IO 2W H Z Z A.45 Z L 1311800000 RS 16IO 2W L H Z A.45 6ES7322-1BL00-0A00 32 DO V I 1311810000 RS 16IO 2W I H S A.46 H2016 V L I 9445750000 RS 16IO 2W I-L H S A.46 6ES7322-1BP00-0AA0 64 DO 2-wire Z I 1311820000 RS 16IO 2W I H Z A.46 Z L I 1311830000 RS 16IO 2W I-L H Z A.46 16-channel C) 64 DO 6ES7322-1BP50-0AA0 V F 9445820000 RS 16IO 2W F H S A.47 V L F RS 16IO 2W F-L H S A.47 6ES7322-1CF00-0AA0 81311850000 DO Z F 1311840000 RS 16IO 2W F H Z A.47 Z L F 1311870000 RS 16IO 2W F-L H Z A.47 6ES7322-1CF80-0AA0 89445760000 DO V RS 16IO 3W H S A.48 V L 9445770000 RS 16IO 3W L H S A.48 3-wire 161311880000 DO RS 16IO 3W H Z Z 6ES7322-1EH00-0AA0 A.48 Z L 1311890000 RS 16IO 3W L H Z A.48 6ES7322-1EH01-0AA0 16 DO V 9441500000 RS 16IO 1W R S A.49 1-wire DO V I 9441860000 RS 16IO 1W I R S A.49 6ES7322-1EL00-0AA0 32 DO V R2416 9441700000 RS 16IO 2W R S A.50 2-wire V F 9441560000 RS 16IO 2W F R S A.50 6ES7322-1FF00-0AA0 89441600000 DO V I RS 16IO 3W I R S A.51 3-wire 6ES7322-1FF01-0AA0 89445900000 DO V RS 32IO 1W H S A.52 V L 9445910000 RS 32IO 1W L H S A.52 1-wire 6ES7322-1FF81-0AA0 89445870000 DO V L I RS 32IO 1W I-L H S A.53 V L 9445930000 RS 32IO 2W L H S A.54 H2032 6ES7322-1FH00-0AA0 169445950000 DO RS 32IO 2W I-L H S 2-wire V L I A.54 V F 9445980000 RS 32IO 2W F H S A.55 6ES7322-1FL00-0AA0 329445960000 DO RS 32IO 3W H S 32-channel V A.56 3-wire V L 9445970000 RS 32IO 3W L H S A.56 6ES7322-1HF80-0AA0 89441510000 DO V RS 32IO 1W R S A.57 1-wire V I 9441870000 RS 32IO 1W I R S A.57 D) 4 DO 6ES7322-5RD00-0AB0 V R3632 9441710000 RS 32IO 2W R S A.58 2-wire V F 9441570000 RS 32IO 2W F R S A.58 D) V I RS 32IO 3W I R S A.59 3-wire 49441610000 DO 6ES7322-5SD00-0AB0 Coding of the interface descriptions RS 8IO: 8 inputs/outputs 1W:1-wire (empty): Direct H HE connector (ribbon cable) S: Screw Note 1: 12IO: 12 inputs/outputs 2W:2-wire I: Switch R: RSV connector Z: Tension clamp connection 6ES7322-8BF00-0AB0 8 DO, without redundancy 16IO: 16 inputs/outputs 3W:3-wire L: LED 32IO: 32 inputs/outputs Number of wires F: Fuse I-L Switch + LED 6ES7322-8BF00-0AB0F-L: Fuse + LED 8 DO, with redundancy 2 units of the following products from the Note 2: 16 DO, without redundancy 9445700000 RS 6ES7322-8BH01-0AB0 16IO 1W H S 2 units 9445900000 RS 32IO 1W H S 1 unit H2016 family can be replaced by 1 unit 9445710000 RS 16IO 1W L H S 2 units 9445910000 RS 32IO 1W L H S 1 unit from the H2032 family 16 DO, with 9445810000 RS 6ES7322-8BH01-0AB0 16IO 1W I-L H S 2 units 9445870000 RS 32IO 1W I-L Hredundancy S 1 unit 9445730000 RS 16IO 2W L H S 2 units 9445930000 RS 32IO 2W L H S 1 unit 8 DI RS 32IO 2W I-L H S 9445750000 RS 16IO 2W I-L H S 2 units 9445950000 1 unit 9445820000 RS 6ES7323-1BH00-0A00 16IO 2W F H S 2 units 9445980000 RS 32IO 2W F H S 1 unit 8DO RS 32IO 3W H S 9445760000 RS 16IO 3W H S 2 units 9445960000 1 unit 9445770000 RS 16IO 3W L H S 2 units 9445970000 RS 32IO 3W L H S 1 unit 8 DI 6ES7323-1BH01-00A0 8 DO 8 DI DI/DO 6ES7323-1BH80-0AA0 8 DO 1327330000 – 2012/2013 8 DI 6ES7323-1BH80-0A00 8 DO 16 DI 6ES7323-1BL00-0AA0 16 DO 2 A PLC Input/Output cards Manufacturer code 6ES7321-1BH00-0AA0 6ES7321-1BH01-0AA0 6ES7321-1BH02-0AA0 6ES7321-1BH50-0AA0 6ES7321-1BH80-0AA0 6ES7321-1BH81-0AA0 6ES7321-1BH82-0AA0 6ES7321-1BL00-0AA0 6ES7321-1BL80-0AA0 5 6 A.10 7 Interfaces Order No. 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789236xxx 7789236xxx 7789771xxx 7789768xxx 7789211xxx 7789211xxx 7789212xxx 7789212xxx 7789215xxx 7789219xxx 7789219xxx 7789219xxx 7789212xxx 7789210xxx 7789210xxx 7789210xxx 7789801xxx 7789239xxx 7789239xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789236xxx 7789246xxx 7789246xxx 7789191xxx 7789191xxx 7789211xxx 7789211xxx 7789211xxx 7789219xxx 7789219xxx 7789219xxx 7789211xxx 7789211xxx 7789190xxx 7789192xxx 7789192xxx 7789239xxx 7789830xxx 7789729xxx 7789730xxx Quantity 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 2 1 1 1 1 2 1 1 1 1 1 1 1 7789237xxx 1 7789237xxx 1 7789237xxx 1 7789237xxx 1 7789236xxx 1 Direct inputs/outputs Insulated inputs - see page A.38 (H) or A.60 (A) Type Quantity H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 H2016 4 H2016 4 R2416 1 R2416 1 R2416 1 R2416 1 R3632 1 R1208 1 R1208 1 R1208 1 R2416 1 R2416 1 R2416 1 R2416 1 H20 1 H2008 1 H2008 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 4 H2016 4 R1208 1 R1208 1 R2416 1 R2416 1 R2416 2 R1208 1 R1208 1 R1208 1 R2416 1 R2416 2 R2416 1 H2016 1 H2016 1 H2008 1 H2008 1 H2016 1 H2016 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2016 1 H2016 1 - see page A.66 Type Quantity I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 2 I2016 2 I2016 4 Insulated outputs - see page A.70 Type Quantity A 3 O2008 1 O2016 O2016 O2016 O2016 O2016 O2016 1 1 1 2 4 4 The selection tables help you to choose the O2008pre-assembled 1 O2016 1 cables and interfaces. 1Select the PLC card from the corresponding table Example: • PLC: Siemens S7-300 • Card: 6ES7321-1BH82-0AA0 2Check the code of the cable to be ordered: Example: • Cable code 7789234xxx • Quantity: 1 unit (by card) The last 3 digits indicate the length: For example 015 indicates 1.5 m I2016 O2008 O2008 O2016 O2016 1 1 1 1 O2008 1 O2008 1 O2008 1 O2008 1 O2016 1 1 1327330000 – 2012/2013 1327330000 – 2012/2013 A.33 Universal solutions for PLC input/ output cards Introduction 3Locate the exact family of modules and the quantity you require Example: • H2016 System Quantity: 1 unit (by card) or • I2016 System Quantity: 1 unit (by card) Take the notes into account (if there are any) The portfolio includes: Passive digital input/output interfaces (H System) H20: Universal interface for pin to pin 20 pole ribbon cable (see chapter C) H2008: Passive input/output 8-channel digital interface H2012: Passive input/output 12-channel digital interface H2016: Passive input/output 16-channel digital interface H2032: Passive input/output 32-channel digital interface H40: Universal interface for pin to pin 40 pole ribbon cable (see chapter C) P assive digital input/output interfaces for high voltage (R System) R1208: Passive input/output 8-channel digital interface (for high voltage) R2416: Passive input/output 16-channel digital interface (for high voltage) R3632: Passive input/output 32-channel digital interface (for high voltage) Passive analogue output/input interfaces (S System) A15: Universal interface for pin to pin SUB-D 15 male poles (see catalogue C) A25: Universal interface for pin to pin SUB-D 25 male poles (see catalogue C) A1504: Passive input/output 4-channel analogue interface A2508: Passive input/output 8-channel analogue interface A3716: Passive input/output 16-channel analogue interface A1504M: Passive input/output 4-channel analogue interface (specific) A2508P: Passive input/output 8-channel analogue interface (specific) A2509M: Passive input/output 8+1-channel analogue interface (specific) 1327330000 – 2012/2013 Relay insulated digital output/input interfaces O2008: 8-channel insulated digital output interface O2012: 12-channel insulated digital output interface O2016: 16-channel insulated digital output interface I2016: 16-channel insulated digital input interface A 4Note the page number that is shown in the top part of the column Example: • H2016 System -> See page A.38 or • I2016 System -> See page A.66 5 O nce the module family is chosen (step 3 - eg H2016), go to the page identified in step 4 and locate that family in the new table on that page. 6Choose the interface according to your application needs ie. 1, 2 or 3 wires, screw or tension clamp connection, with fuse, LED, switch, etc. 7 G o to the specifications page where you can check all the details of the interface. A.11 Universal solutions for PLC input/ output cards Selection guide PLC ABB S800 A DI DO AI AO Note PLC Cables Input/Output cards Standard Manufacturer code DI810 DI811 DI814 A) DI830 DI831 DI840 DI880 DO810 DO814 B) DO815 DO840 DO880 AI810 C) AI820 C) AI830 C) AI830A C) AI845 C) AO810 C) AO810V2 C) AO820 C) AO845 C) Number/Type of channels 16 DI 16 DI 16 DI 16 DI 16 DI 16 DI 16 DI 16 DO 16 DO 16 DO 16 DO 16 DO 8 AI 4 AI 8 AI 8 AI 8 AI 8 AO 8 AO 4 AO 8 AO Order No. 7789641xxx 7789642xxx 7789641xxx 7789641xxx 7789642xxx 7789641xxx 7789641xxx 7789641xxx 7789641xxx 7789643xxx 7789641xxx 7789641xxx 7789657xxx 7789657xxx 7789657xxx 7789657xxx 7789657xxx 7789657xxx 7789657xxx 7789657xxx 7789657xxx Interfaces Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Direct inputs/outputs Insulated inputs - see page A.38 (H) or A.60 (A) Type Quantity H2016 1 R2416 1 H0216 1 H2016 1 R2416 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 A25 1 A25 1 A25 1 A25 1 A25 1 A25 1 A25 1 A25 1 A25 1 - see page A.66 Type Quantity I2016 1 I2016 I2016 1 1 I2016 I2016 1 1 Insulated outputs - see page A.70 Type Quantity O2016 O2016 O2016 O2016 O2016 1 1 1 1 1 A) Attention! Only use interfaces without LEDs B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option C) Attention! Only use these interfaces: 8537370000 or 8005181001. More information in chapter C •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. •Use with 812TU MTU * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.12 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC EMERSON DELTA V DI DO AI AO Note PLC Cables Input/Output cards Standard Manufacturer code VE4001S2T1B1 A) VE4001S2T1B2 A) VE4001S2T1B3 A) VE4001S2T2B1 A) VE4001S2T2B2 A) VE4001S2T2B3 A) VE4001S2T2B4 A) VE4001S2T2B5 A) VE4001S3T1B1 VE4001S3T1B2 VE4001S3T2B1 VE4001S3T2B2 VE4002S1T1B1 A) VE4002S1T1B2 A) VE4002S1T1B3 A) VE4002S1T2B1 A) VE4002S1T2B2 A) VE4002S1T2B3 A) VE4002S1T2B4 A) VE4002S1T2B5 A) VE4002S1T2B6 A) VE4002S2T1B2 VE4002S2T2B1 VE4002S2T2B2 VE4003S2B1 VE4003S2B2 VE4003S2B3 VE4003S2B4 VE4003S2B6 VE4003S3B3 VE4003S3B4 VE4003S6B1 VE4005S2B1 VE4005S2B2 VE4005S2B3 Number/Type of channels 8 DI 8 DI 8 DI 8 DI 8 DI 8 DI 32 DI 32 DI 8 DI 8 DI 8 DI 8 DI 8 DO 8 DO 8 DO 8 DO 8 DO 8 DO 8 DO 32 DO 32 DO 8 DO 8 DO 8 DO 8 AI 8 AI 8 AI 8 AI 16 AI 8 AI 8 AI 8 AI 8 AO 8 AO 8 AO Order No. 7789100xxx 7789100xxx 7789701xxx 7789100xxx 7789100xxx 7789701xxx 7789100xxx 7789702xxx 7789104xxx 7789104xxx 7789104xxx 7789104xxx 7789100xxx 7789100xxx 7789701xxx 7789100xxx 7789100xxx 7789700xxx 7789703xxx 7789100xxx 7789702xxx 7789108xxx 7789104xxx 7789104xxx 7789252xxx 7789252xxx 7789252xxx 7789704xxx 7789254xxx 7789252xxx 7789704xxx 7789254xxx 7789252xxx 7789252xxx 7789704xxx Interfaces Direct inputs/outputs Quantity 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 R2416 1 R2416 1 R2416 1 R2416 1 H2008 1 H2008 1 H2016 1 H2008 1 H2008 1 H2008 1 H2008 1 H2016 2 H2016 2 R1208 1 R2416 1 R2416 1 A2508 1 A2508 1 A2508 1 A2508 1 A3716 1 A2508 1 A2508 1 A3716 1 A2508 1 A2508 1 A2508 1 Insulated inputs - see page A.66 Type Quantity Insulated outputs - see page A.70 Type Quantity A A) Attention! Only use interfaces without LEDs •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. •Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end. These cables do not have a PLC connector. Colour code according to DIN 47100. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.13 Universal solutions for PLC input/ output cards Selection guide PLC GEFANUC 90-30 A DI DO AO AI/AO Note Cables Standard Manufacturer code IC693MDL230 IC693MDL231 IC693MDL240 IC693MDL241 IC693MDL630 IC693MDL632 IC693MDL634 IC693MDL640 IC693MDL643 IC693MDL645 IC693MDL646 IC693MDL654 IC693MDL655 IC693MDL310 IC693MDL340 IC693MDL730 IC693MDL731 A) IC693MDL732 IC693MDL733 A) IC693MDL740 IC693MDL741 A) IC693MDL742 IC693MDL752 A) IC693MDL753 IC693MDL930 IC693ALG220 AI PLC Input/Output cards IC693ALG221 IC693ALG222 IC693ALG223 IC693ALG390 IC693ALG391 IC693ALG392 IC693ALG392 IC693ALG442 Numero/Type canales 8 DI 8 DI 16 DI 16 DI, positive logic 8 DI 8 DI, positive logic 8 DI, positive logic 16 DI 16 DI 16 DI, positive logic 16 DI, positive logic 32 DI, positive logic 32 DI, positive logic 12 DO 16 DO 8 DO 8 DO 8 DO 8 DO 16 DO 16 DO 16 DO 32 DO 32 DO 8 DO 4 AI, voltage differential applications 4 AI, current applications 16 AI or 8 AI 16 AI 4 AO 4 AO 8 AO, current applications 8 AO, voltage applications 4 AI 2 AO Interfaces Direct inputs/outputs - see page A.38 (H) or A.60 (A) Type Quantity R2416 1 R2416 1 R2416 1 H2016 1 H2008 1 R1208 1 H2008 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 R2416 1 R2416 1 H2008 1 H2016 1 H2008 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 R2416 1 Order No. 7789064xxx 7789064xxx 7789061xxx 7789067xxx 7789067xxx 7789634xxx 7789067xxx 7789067xxx 7789067xxx 7789067xxx 7789067xxx 7789066xxx 7789066xxx 7789063xxx 7789063xxx 7789069xxx 7789069xxx 7789068xxx 7789068xxx 7789068xxx 7789068xxx 7789068xxx 7789066xxx 7789066xxx 7798064xxx Quantity 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 2 2 1 7789076xxx 1 A1504 1 7789075xxx 1 A1504 1 7789072xxx 7789072xxx 7789073xxx 7789073xxx 7789620xxx 7789624xxx 1 1 1 1 1 A2508 A2508 A2508 A2508 A1504 A1504 1 1 1 1 1 1 7789074xxx 1 A3716 1 Insulated inputs - see page A.66 Type Quantity I2016 1 I2016 I2016 I2016 I2016 1 1 2 2 Insulated outputs - see page A.70 Type Quantity O2008 O2016 O2008 O2016 O2016 O2016 O2016 O2016 O2016 1 1 1 1 1 1 1 2 2 A) Attention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.14 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC GEFANUC RX3i DI DO IC694ALG221 IC694ALG222 IC694ALG223 IC695ALG600 IC695ALG600 IC695ALG608 AO AI/AO Note Cables Standard Manufacturer code IC694MDL230 IC694MDL231 IC694MDL240 IC694MDL241 IC694MDL250 IC694MDL260 IC694MDL632 IC694MDL634 IC694MDL645 IC694MDL646 IC694MDL654 IC694MDL655 IC694MDL660 IC694MDL310 IC694MDL330 IC694MDL340 IC694MDL350 IC694MDL390 IC694MDL732 IC694MDL734 IC694MDL740 IC694MDL741 A) IC694MDL742 IC694MDL752 A) IC694MDL753 IC694MDL754 IC694MDL916 IC694MDL930 IC694MDL931 IC694MDL940 IC694ALG220 AI PLC Input/Output cards IC695ALG616 IC695ALG616 IC694ALG390 IC694ALG391 IC694ALG392 IC694ALG392 IC695ALG704 IC695ALG708 IC695ALG808 IC694ALG442 Number/Type of channels 8 DI 8 DI 16 DI 16 DI, positive logic 16 DI 32 DI 8 DI, positive logic 8 DI, positive logic 16 DI, positive logic 16 DI, positive logic 32 DI, positive logic 32 DI, positive logic 32 DI 12 DO 8 DO 16 DO 16 DO 5 DO 8 DO 6 DO 16 DO 16 DO 16 DO 32 DO 32 DO 32 DO 16 DO 8 DO 8 DO 16 DO 4 AI, voltage differential applications 4 AI, voltage differential applications 16 AI 16 AI 8AI, resistance applications 8AI, voltage or current applications 8AI, common applications 16 AI, differential applications 8 AI, differential applications 16 AI, common mode applications 2 AO 2 AO 8 AO, current applications 8 AO, voltage applications 4 AO 8 AO 8 AO 4 AI 2 AO Interfaces Direct inputs/outputs - see page A.38 (H) or A.60 (A) Type Quantity R2416 1 R2416 1 R2416 1 H2016 1 R3632 1 R3632 1 R1208 1 H2008 1 H2008 1 H2008 1 H2016 2 H2016 2 H2016 2 R2416 1 R1208 1 R2416 1 R3632 1 R2416 1 H2008 1 R2416 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 H2016 2 R3632 1 R2416 1 R3632 1 R2416 1 Order No. 7789064xxx 7789064xxx 7789061xxx 7789067xxx 7789631xxx 7789632xxx 7789634xxx 7789067xxx 7789067xxx 7789067xxx 7789066xxx 7789066xxx 7789619xxx 7789063xxx 7789634xxx 7789063xxx 7789631xxx 7789636xxx 7789068xxx 7789669xxx 7789068xxx 7789068xxx 7789068xxx 7789066xxx 7789066xxx 7789618xxx 7789696xxx 7789064xxx 7789665xxx 7789666xxx Quantity 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 7789076xxx 1 A1504 1 7789075xxx 1 A1504 1 7789072xxx 7789072xxx 7789622xxx 7789623xxx 1 1 1 1 A2508 A2508 A3716 A3716 1 1 1 1 7789667xxx 1 A2508 1 7789626xxx 7789798xxx 7789073xxx 7789073xxx 7789620xxx 7789624xxx 7789668xxx 7789625xxx 7789621xxx 1 1 1 1 1 1 1 1 1 A3716 A3716 A2508 A2508 A1504 A1504 A1504 A2508 A2508 1 1 1 1 1 1 1 1 1 7789074xxx 1 A3716 1 Insulated inputs - see page A.66 Type Quantity I2016 1 I2016 I2016 I2016 I2016 I2016 1 1 2 2 2 Insulated outputs - see page A.70 Type Quantity O2016 1 O2016 O2016 O2016 O2016 O2016 O2016 1 1 1 2 2 2 A A) Attention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will * always find the most up-to-date information. 1327330000 – 2012/2013 A.15 Universal solutions for PLC input/ output cards Selection guide PLC HONEYWELL C200 A DI DO AI AO Note PLC Cables Input/Output cards Standard Manufacturer code TC-IDA161 / TK-IDA161 TC-IDD321 / TK-IDD321 TC-IDJ161 / TK-IDJ161 TC-IDK161 / TK-IDK161 TC-IDW161 / TK-IDW161 TC-IDX081 / TK-IDX081 TC-IDX161 / TK-IDX161 TC-ODA161 TK-ODA161 TC-ODD321 / TK-ODD321 TC-ODJ161 / TK-ODJ161 TC-ODK161 / TK-ODK161 TC-ODX081 / TK-ODX081 TC-ODX161 / TK-ODX161 TC-ORC081 / TK-ORC081 TC-ORC161 / TK-ORC161 TC-IAH061 / TK-IAH061 TC-IAH061 / TK-IAH061 TC-IAH161 / TK-IAH161 TC-IXR061 / TK-IXR061 TC-OAH061 / TK-OAH061 TC-OAV061 / TK-OAV161 TC-OAV081 / TK-OAV081 TC-OAV081 / TK-OAV081 Number/Type of channels 16 DI 32 DI 16 DI 16 DI 16 DI 8 DI 16 DI 16 DO 32 DO 16 DO 16 DO 8 DO 16 DO 8 DO 16 DO 6 AI, current applications 6 AI, voltage applications 16 AI 6 AI, resistances 0 to 550 Ω 6 AO 6 AO 8 AO, current applications 8 AO, voltage applications Order No. 7789031xxx 7789041xxx 7789049xxx 7789030xxx 7789030xxx 7789048xxx 7789049xxx 7789056xxx 7789042xxx 7789059xxx 7789030xxx 7789057xxx 7789040xxx 7789155xxx 7789030xxx 7789156xxx 7789157xxx 7789032xxx 7789158xxx 7789159xxx 7789157xxx 7789037xxx 7789038xxx Interfaces Direct inputs/outputs Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity R2416 1 H2016 2 H2016 1 R3632 1 R3632 1 R1208 1 H2016 1 R2416 1 H2016 1 H2016 1 R3632 1 R1208 1 H2016 1 R2416 1 R3632 1 A2508 1 A2508 1 A3716 1 A2508 1 A2508 1 A2508 1 A2508 1 A2508 1 Insulated inputs - see page A.66 Type Quantity I2016 I2016 2 1 I2016 1 Insulated outputs - see page A.70 Type Quantity O2016 O2016 1 1 O2016 1 A) Attention! Only use interfaces without LEDs B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.16 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC MITSUBISHI MELSEC Q DI DO QX41Y41P C) QX48Y57 C) AI AO Note Cables Standard Manufacturer code QX10 QX28 QX40 A) QX40-S1 A) QX41 A) QX41-S1 A) QX42 A) QX42-S1 A) QX50 QX70 A) QX71 A) QX72 A) QX80 QX82 QX82-S1 QY10 QY18A QY22 QY40P B) QY41P B) QY42P B) QY50 B) QY68A QY70 B) QY71 B) QY80 QH42P C) DI/DO PLC Input/Output cards Q62AD-DGH Q64AD Q64AD-GH Q68AD-G Q68AD-G Q68ADI Q68ADV Q62DA Q62DA-FG Q62DAN Q64DA Q64DAN Q66DA-G Q66DA-G Q68DAI Q68DAIN Q68DAV Q68DAVN Number/Type of channels 16 DI 8 DI 16 DI 16 DI 32 DI 32 DI 64 DI 64 DI 16 DI 16 DI 32 DI 64 DI 16 DI 64 DI 64 DI 16 DO 8 DO 16 DO 16 DO 32 DO 64 DO 16 DO 8 DO 16 DO 32 DO 16 DO 32 DI 32 DO 32 DI 32 DO 8 DI 7 DO 2 AI 4 AI 4 AI 8 AI, current applications 8 AI, voltage applications 8 AI 8 AI 2 AO 2AO 2 AO 4 AO 4 AO 6 AO, current applications 6 AO, voltage applications 8 AO 8 AO 8 AO 8 AO Interfaces Direct inputs/outputs Order No. 7789104xxx 7789108xxx 7789100xxx 7789100xxx 7789681xxx 7789681xxx 7789681xxx 7789681xxx 7789104xxx 7789100xxx 7789681xxx 7789681xxx 7789100xxx 7789683xxx 7789683xxx 7789104xxx 7789104xxx 7789104xxx 7789100xxx 7789708xxx 7789708xxx 7789100xxx 7789100xxx 7789100xxx 7789708xxx 7789100xxx 7789681xxx 7789708xxx 7789681xxx 7789708xxx Quantity 1 1 1 1 1 1 2 2 1 1 1 2 1 2 2 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 7789100xxx 2 7789250xxx 7789250xxx 7789250xxx 7789684xxx 7789685xxx 7789252xxx 7789252xxx 7789250xxx 7789250xxx 7789250xxx 7789250xxx 7789250xxx 7789710xxx 7789711xxx 7789252xxx 7789252xxx 7789252xxx 7789252xxx 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity R2416 1 R1208 1 H2016 1 H2016 1 H2016 2 H2016 2 H2016 4 H2016 4 R2416 1 H2016 1 H2016 2 H2016 4 H2016 1 H2016 4 H2016 4 R2416 1 R2416 1 R2416 1 H2016 1 H2016 2 H2016 4 H2016 1 H2016 1 H2016 1 H2016 2 H2016 1 H2016 2 H2016 2 H2016 2 H2016 2 H2016 1 H2016 1 A1504 1 A1504 1 A1504 1 A2508 1 A2508 1 A2508 1 A2508 1 A1504 1 A1504 1 A1504 1 A1504 1 A1504 1 A2508 1 A2508 1 A2508 1 A2508 1 A2508 1 A2508 1 Insulated inputs - see page A.66 Type Quantity I2016 I2016 I2016 Insulated outputs - see page A.70 Type Quantity A 1 4 4 O2016 O2016 O2016 O2016 O2016 O2016 O2016 O2016 1 2 4 1 1 1 2 1 O2016 2 O2016 2 O2016 1 A) Attention! Only use interfaces without LEDs B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option C) Attention! Use only interfaces without LEDs for the direct options. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated outlet option •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. •Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end. These cables do not have a PLC connector. Colour code according to DIN 47100. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.17 Universal solutions for PLC input/ output cards Selection guide PLC MOELLER XIOC A PLC Cables Input/Output cards Standard Manufacturer code XIOC-16DI DI XIOC-16DI-AC XIOC-16DI-AC110 XIOC-32DI XIOC-8DI DO DI/DO AI AO XIOC-12DO-R B) XIOC-16DO XIOC-16DO-S XIOC-32DO XIOC-8DO XIOC-16DX XIOC-8AI-I2 XIOC-8AI-U1 XIOC-8AI-U2 XIOC-2AO-U1-2AO-I2 XIOC-2AO-U2 XIOC-4AO-U1 XIOC-4AO-U2 XIOC-2AI-1AO-U1 AI/AO XIOC-2AI-1A0-U1-I1 XIOC-4AI-2AO-U1 XIOC-4AI-2AO-U1-I1 Note Number/Type of channels 16 DI, positive logic 16 DI, negative logic A) 16 DI 16 DI 32 DI, positive logic 32 DI, negative logic A) 8 DI, positive logic 8 DI, negative logic A) 12 DO 16 DO 16 DO 32 DO 8 DO 16 DI 16 DO 8 AI 8 AI 8 AI 4 AO 2 AO 4 AO 4 AO 2 AI 2 AO 2 AI 2 AO 4 AI 2 AO 4 AI 2 AO Interfaces Direct inputs/outputs Insulated inputs - see page A.38 (H) or A.60 (A) Type Quantity H2016 1 H2016 1 R2416 1 R2416 1 H2016 2 H2016 2 H2008 1 H2016 1 R2416 1 H2016 1 H2016 1 H2016 2 H2008 1 - see page A.66 Type Quantity I2016 1 Order No. 7789862xxx 7789863xxx 7789864xxx 7789864xxx 7789771xxx 7789768xxx 7789862xxx 7789863xxx 7789871xxx 7789865xxx 7789865xxx 7789866xxx 7789865xxx Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 7789872xxx 1 H2016 1 7789867xxx 7789867xxx 7789867xxx 7789868xxx 7789868xxx 7789868xxx 7789868xxx 1 1 1 1 1 1 1 A2508 A2508 A2508 A1504 A1504 A1504 A1504 1 1 1 1 1 1 1 7789870xxx 1 A1504 1 7789870xxx 1 A1504 1 7789869xxx 1 A2508 1 7789869xxx 1 A2508 1 I2016 Insulated outputs - see page A.70 Type Quantity 2 O2016 O2016 O2016 O2008 1 1 2 1 A) Attention! Only use interfaces without LEDs B) The 24 V DC power supply should be provided externally •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.18 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC OMRON – C200H PLC Cables Input/Output cards Standard Manufacturer code IA121 IA122 IA122V IA222V ID001 A) ID002 DI ID211 ID212 ID216 ID217 DO Note IM211 IM212 A) OA221 OA222V OC221 OC222V OC223 OC224V OC225 OD211 B) OD212 B) OD213 B) OD214 OD217 OD411 B) Number/Type of channels 8 DI 16 DI 16 DI 16 DI 8 DI 8 DI 8 DI, positive logic 8 DI, negative logic A) 16 DI, positive logic 16 DI, negative logic A) 32 DI, positive logic 32 DI, negative logic A) 64 DI, positive logic 64 DI, negative logic A) 8 DI, 24 V DC applications 16 DI, 24 V DC applications 8 DO 12 DO 8 DO 12 DO 5 DO 8 DO 16 DO 16 DO 16 DO 8 DO 8 DO 12 DO 8 DO Order No. 7789108xxx 7789104xxx 7789104xxx 7789104xxx 7789100xxx 7789100xxx 7789100xxx 7789100xxx 7789100xxx 7789100xxx 7789771xxx 7789768xxx 7789771xxx 7789768xxx 7789100xxx 7789100xxx 7789108xxx 7789104xxx 7789108xxx 7789104xxx 7789108xxx 7789104xxx 7789104xxx 7789100xxx 7789100xxx 7789100xxx 7789100xxx 7789100xxx 7789100xxx Interfaces Direct inputs/outputs Quantity 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity R1208 1 R2416 R2416 1 R2416 1 H2016 1 H2008 1 H2008 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 H2016 4 H2016 4 H2008 1 H2016 1 R1208 1 R2416 1 R1208 1 R2416 1 R1208 1 R2416 1 R2416 1 H2016 1 H2016 1 H2016 1 H2008 1 H2012 1 H2016 1 Insulated inputs - see page A.66 Type Quantity Insulated outputs - see page A.70 Type Quantity I2016 1 I2016 2 I2016 4 O2016 O2016 O2016 O2008 O2012 O2016 A 1 1 1 1 1 1 A) Attention! Only use interfaces without LEDs B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. •Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end. These cables do not have a PLC connector. Colour code according to DIN 47100. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.19 Universal solutions for PLC input/ output cards Selection guide PLC OMRON – CJ1W A PLC Cables Input/Output cards Standard Manufacturer code IA111 IA201 ID211 DI ID231 ID232 ID261 ID262 DO DI/DO Note OA201 OC201 OC211 OD201 B) OD202 OD211 B) OD212 OD231 B) OD232 OD233 B) OD261 B) OD262 OD263 B) MD232 MD232 C) Number/Type of channels 16 DI 8 DI 16 DI, positive logic 16 DI, negative logic A) 32 DI, positive logic 32 DI, negative logic A) 32 DI, positive logic 32 DI, negative logic A) 64 DI, positive logic 64 DI, negative logic A) 64 DI, positive logic 64 DI, negative logic A) 8 DO 8 DO 16 DO 8 DO 8 DO 16 DO 16 DO 32 DO 32 DO 32 DO 64 DO 64 DO 64 DO 16 DI, positive logic 16 DO 16 DI, negative logic 16 DO Order No. 7789664xxx 7789648xxx 7789645xxx 7789833xxx 7789771xxx 7789768xxx 7789772xxx 7789767xxx 7789771xxx 7789768xxx 7789772xxx 7789767xxx 7789648xxx 7789649xxx 7789664xxx 7789650xxx 7789650xxx 7789794xxx 7789794xxx 7789793xxx 7789373xxx 7789373xxx 7789793xxx 7789373xxx 7789373xxx 7789328xxx 7789329xxx 7789329xxx 7789329xxx Interfaces Direct inputs/outputs Quantity 1 1 1 1 1 1 1 1 2 2 2 2 1 1 1 1 1 1 1 1 1 1 2 2 2 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity R2416 1 R1208 1 H2016 1 H2016 1 H2016 2 H2016 2 H2016 2 H2016 2 H2016 4 H2016 4 H2016 4 H2016 4 R1208 1 R2416 1 R2416 1 H2016 1 H2008 1 H2016 1 H2016 1 H2016 2 H2016 2 H2016 2 H2016 4 H2016 4 H2016 4 H2016 1 H2016 1 H2016 1 H2016 1 Insulated inputs - see page A.66 Type Quantity I2016 1 I2016 2 I2016 2 I2016 4 I2016 4 Insulated outputs - see page A.70 Type Quantity O2016 O2008 O2016 O2016 O2016 O2016 O2016 O2016 O2016 O2016 1 1 2 2 2 2 2 4 4 4 O2016 1 O2016 1 A) Attention! Only use interfaces without LEDs B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option C) Attention! Use only interfaces without LEDs for the direct input option •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.20 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC OMRON – CQM1 DI DO Note AI AO PLC Cables Input/Output cards Standard Manufacturer code IA121 IA221 ID211 A) ID211 A) ID212 ID213 ID213 A) OA221 OC221 OC222 OD211 B) OD212 B) OD213 B) OD214 AD041 DA021 Number/Type of channels 8 DI 8 DI 8 DI, positive logic 8 DI, negative logic 16 DI, positive logic 32 DI, positive logic 32 DI, negative logic 8 DO 8 DO 16 DO 8 DO 16 DO 32 DO 16 DO 4 AI 2 AO Order No. 7789108xxx 7789108xxx 7789100xxx 7789100xxx 7789100xxx 7789771xxx 7789768xxx 7789108xxx 7789104xxx 7789104xxx 7789663xxx 7789100xxx 7789793xxx 7789100xxx 7789252xxx 7789250xxx Interfaces Direct inputs/outputs Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity R1208 1 R1208 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 R1208 1 R2416 1 R2416 1 H2016 1 H2016 1 H2016 2 H2016 1 A2508 1 A1504 1 Insulated inputs - see page A.66 Type Quantity I2016 I2016 Insulated outputs - see page A.70 Type Quantity A 1 2 O2016 O2016 O2016 O2016 1 1 2 1 A) Attention! Only use interfaces without LEDs B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. •Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end. These cables do not have a PLC connector. Colour code according to DIN 47100. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.21 Universal solutions for PLC input/ output cards Selection guide PLC ROCKWELL – COMPACT LOGIX A PLC Cables Input/Output cards Standard Manufacturer code 1769-IA16 1769-IA8I 1769-IM12 1769-IQ16 DI 1769-IQ16F 1769-IQ32 32 DI, positive logic 1769-IQ32 A) 32 DI, negative logic 1769-OA16 1769-OA8 1769-OB16 1769-OB16P 32 DI, positive logic 32 DI, negative logic A) 16 DO 8 DO 16 DO 16 DO 1769-OB32 32 DO 1769-OB32T 1769-OB8 1769-OV16 1769-OW16 1769-OW8 1769-OW8I 1769-IF4 1769-IF4 1769-IF4I 1769-IF4I 1769-IF8 1769-IF8 1769-OF2 1769-OF4CI 1769-OF8C 1769-OF8V 32 DO 8 DO 16 DO 16 DO 8 DO 8 DO 4 AI, current applications 4 AI, voltage applications 4 AI, current applications 4 AI, voltage applications 8 AI, current applications 8 AI, voltage applications 2 AO 4 AO 8 AO 8 AO 1769-IQ32T DO AI AO Note Number/Type of channels 16 DI 8 DI 12 DI 16 DI, positive logic 16 DI, negative logic A) 16 DI, positive logic 16 DI, negative logic A) Order No. 7789025xxx 7789016xxx 7789025xxx 7789770xxx 7789831xxx 7789770xxx 7789831xxx 7789770xxx 7789695xxx 7789831xxx 7789832xxx 7789005xxx 7789670xxx 7789024xxx 7789017xxx 7789769xxx 7789769xxx 7789769xxx 7789697xxx 7789006xxx 7789015xxx 7789769xxx 7789024xxx 7789017xxx 7789016xxx 7789026xxx 7789046xxx 7789027xxx 7789047xxx 7789028xxx 7789045xxx 7789029xxx 7789043xxx 7789044xxx 7789044xxx Interfaces Direct inputs/outputs Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity R2416 1 R2416 1 R2416 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 H2016 H2016 R2416 R1208 H2016 H2016 1 1 1 1 1 1 H2016 H2016 H2008 H2016 R2416 R1208 R2416 A1504 A1504 A1504 A1504 A2508 A2508 A1504 A1504 A2508 A2508 Insulated inputs - see page A.66 Type Quantity I2016 1 I2016 1 I2016 2 I2016 1 Insulated outputs - see page A.70 Type Quantity O2016 O2016 1 1 2 O2016 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 O2016 O2008 O2016 2 1 1 A) Attention! Only use interfaces without LEDs •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.22 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC ROCKWELL – CONTROL LOGIX DI DO AI AO Note PLC Cables Input/Output cards Standard Manufacturer code 1756-IA16 1756-IA16I 1756-IA8D 1756-IB16 1756-IB16D 1756-IB16I 1756-IB32 1756-IC16 1756-IH16I 1756-IM16I 1756-IN16 1756-OA16 1756-OA16I 1756-OA8 1756-OA8D 1756-OA8E 1756-OB16D 1756-OB16E 1756-OB16I 1756-OB32 1756-OB8 1756-OB8EI 1756-OC8 1756-OH8I 1756-ON8 1756-OV16E 1756-OW16I 1756-OX8I 1756-IF16 1756-IF6I 1756-IF6I 1756-IF8 1756-IF8 1756-IR6I 1756-OF4 1756-OF4 1756-OF6CI 1756-OF6VI 1756-OF8 1756-OF8 Number/Type of channels 16 DI 16 DI 8 DI 16 DI 16 DI 16 DI 32 DI 16 DI 16 DI 16 DI 16 DI 16 DO 16 DO 8 DO 8 DO 8 DO 16 DO 16 DO 16 DO 32 DO 8 DO 8 DO 8 DO 8 DO 8 DO 16 DO 16 DO 8 DO 16 AI 6 AI, current applications 6 AI, voltage applications 8 AI, current applications 8 AI, voltage applications 6 AI 4 AO, current applications 4 AO, voltage applications 6 AO, resistances 0 to 550 Ω 6 AO 8 AO, current applications 8 AO, voltage applications Order No. 7789031xxx 7789030xxx 7789048xxx 7789039xxx 7789049xxx 7789049xxx 7789041xxx 7789031xxx 7789030xxx 7789030xxx 7789031xxx 7789056xxx 7789030xxx 7789057xxx 7789048xxx 7789048xxx 7789040xxx 7789058xxx 7789059xxx 7789042xxx 7789151xxx 7789152xxx 7789153xxx 7789154xxx 7789057xxx 7789058xxx 7789030xxx 7789155xxx 7789032xxx 7789156xxx 7789157xxx 7789035xxx 7789036xxx 7789158xxx 7789033xxx 7789034xxx 7789159xxx 7789157xxx 7789037xxx 7789038xxx Interfaces Direct inputs/outputs Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity R2416 1 R3632 1 R1208 1 H2016 1 H2016 1 H2016 1 H2016 2 R2416 1 R3632 1 R3632 1 R3632 1 R3632 1 R3632 1 R1208 1 R1208 1 R1208 1 H2016 1 H2016 1 H2016 1 H2016 2 H2008 1 H2008 1 R2416 1 R2416 1 R1208 1 H2016 1 R3632 1 R2416 1 A3716 1 A2508 1 A2508 1 A2508 1 A2508 1 A2508 1 A1504 1 A1504 1 A2508 1 A2508 1 A2508 1 A2508 1 Insulated inputs - see page A.66 Type Quantity I2016 I2016 I2016 I2016 Insulated outputs - see page A.70 Type Quantity A 1 1 1 2 O2016 O2016 O2016 O2016 O2008 O2008 1 1 1 2 1 1 O2016 1 •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.23 Universal solutions for PLC input/ output cards Selection guide PLC ROCKWELL MICRO LOGIX 1400 A DI DO DI/DO AI AO AI/AO Note PLC Cables Input/Output cards Standard Manufacturer code 1762-IA8 1762-IQ16 1762-IQ32T 1762-IQ8 1762-OA8 1762-OB16 1762-OB32T 1762-OB8 1762-OV32T A) 1762-OW16 1762-OW8 1762-OX6I 1762-IQ8OW6 1762-IQ8OW6 B) 1762-IF4 1762-IR4 1762-IR4 C) 1762-OF4 1762-IF2OF2 Number/Type of channels 16 DI 16 DI 16 DI, positive logic 16 DI, negative logic 8 DI 8 DO 16 DO 32 DO 8 DO 32 DO 16 DO 8 DO 6 DO 8 DI, positive logic 6 DO 8 DI, negative logic 6 DO 4 AI 4 AI, 2-wire applications 4 AI, 3 and 4-wire applications 4 AO 2 AI 2 AO Interfaces Direct inputs/outputs Order No. 7789108xxx 7789100xxx 7789005xxx 7789670xxx 7789100xxx 7789108xxx 7789100xxx 7789006xxx 7789100xxx 7789006xxx 7789104xxx 7789108xxx 7789106xxx 7789100xxx 7789108xxx 7789100xxx 7789108xxx 7789250xxx 7789250xxx 7789252xxx 7789250xxx Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7789250xxx 1 - see page A.38 (H) or A.60 (A) Type Quantity R1208 1 H2016 1 H2016 2 H2016 2 H2008 1 R1208 1 H2016 1 H2016 2 H2008 1 H2016 2 R2416 1 R1208 1 R3632 1 H2008 1 R1208 1 H2016 1 R1208 1 A1504 1 A1504 1 A2508 1 A1504 1 A1504 Insulated inputs - see page A.66 Type Quantity I2016 I2016 Insulated outputs - see page A.70 Type Quantity 1 2 O2016 O2032 O2008 O2016 1 2 1 2 1 A) Attention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option B) A ttention! Use only interfaces without LEDs for the direct input option C) Attention! Only use Interfaces without insulators and test points •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. •Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end. These cables do not have a PLC connector. Colour code according to DIN 47100. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.24 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC ROCKWELL – SLC 500 DI DO AI AO AI/AO Note PLC Cables Input/Output cards Standard Manufacturer code 1746-IB16 1746-IB32 1746-IB8 1746-IC16 1746-IN16 1746-ITB16 1746-ITV16 1746-IV16 1746-IV32 A) 1746-IV8 A) 1746-OA16 1746-OB16 1746-OB16E 1746-OB32 1746-OB32E 1746-OB8 1746-OBP16 1746-OBP8 1746-OG16 A) 1746-OV16 A) 1746-OV32 A) 1746-OV8 A) 1746-OVP16 A) 1746-OW16 1746-OW4 1746-OW8 1746-OX8 1746-NI4 1746-NI8 1746-NO4I 1746-NO4V 1746-NIO4I 1746-NIO4V Number/Type of channels 16 DI 32 DI 8 DI 16 DI 16 DI, DC applications 16 DI 16 DI 16 DI 32 DI 8 DI 16 DO 16 DO 16 DO 32 DO 32 DO 8 DO 16 DO 8 DO 16 DO 16 DO 32 DO 8 DO 16 DO 16 DO, 24 V DC applications 4 DO 8 DO 8 DO 4 AI 8 AI 4 AO 4 AO 2 AI 2 AO 2 AI 2 AO Interfaces Direct inputs/outputs Insulated inputs - see page A.38 (H) or A.60 (A) Type Quantity H2016 1 H2016 2 H2008 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 1 R2416 1 H2016 1 H2016 1 H2016 2 H2016 2 H2008 1 H2016 1 H2008 1 H2016 1 H2016 1 H2016 2 H2016 1 H2016 1 H2016 1 R1208 1 R1208 1 R2416 1 A1504 1 A2508 1 A2508 1 A2508 1 - see page A.66 Type Quantity I2016 1 I2016 2 Order No. 7789001xxx 7789005xxx 7789100xxx 7789001xxx 7789001xxx 7789001xxx 7789000xxx 7789000xxx 7789670xxx 7789100xxx 7789728xxx 7789003xxx 7789003xxx 7789006xxx 7789006xxx 7789100xxx 7789003xxx 7789100xxx 7789003xxx 7789003xxx 7789006xxx 7789100xxx 7789003xxx 7789002xxx 7789108xxx 7789108xxx 7789104xxx 7789008xxx 7789011xxx 7789010xxx 7789010xxx Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7789009xxx 1 A1504 1 7789009xxx 1 A1504 1 1 I2016 I2016 I2016 I2016 I2016 Insulated outputs - see page A.70 Type Quantity A 1 1 1 1 1 O2016 O2016 O2016 O2016 O2008 O2016 O2008 O2016 O2016 O2016 O2016 O2016 1 1 2 2 1 1 1 1 1 2 1 1 A) Attention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.25 Universal solutions for PLC input/ output cards Selection guide PLC SCHNEIDER – M258 A DI DO DI/DO AI AO Note PLC Cables Input/Output cards Standard Manufacturer code TM5SDI12D TM5SDI2D A) TM5SDI4A TM5SDI4D A) TM5SDI6A TM5SDI6D A) TM5SDO12T TMSDO2T A) TM5SDO4R TM5SDO4T A) TM5SDO4TA A) TM5SDO6T A) TM5SDO8TA TM5SDM12DT TM5SAI2H TM5SAI2L TM5SAI2PH B) TM5SAI4H TM5SAI4L TM5SAI4PH B) TM5SAO2H TM5SAO2L TM5SAO4H TM5SAO4L Number/Type of channels 12 DI 2 DI 4 DI 4 DI 6 DI 6 DI 12 DO 2 DO 4 DO 4 DO 4 DO 6 DO 8 DO 8 DI 4 DO 2 AI 2 AI 2 AI 4 AI 4 AI 4 AI 2 AO 2 AO 4 AO 4 AO Interfaces Direct inputs/outputs Order No. 7789840xxx 7789100xxx 7789854xxx 7789100xxx 7789855xxx 7789100xxx 7789840xxx 7789100xxx 7789858xxx 7789100xxx 7789100xxx 7789100xxx 7789857xxx Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 7789859xxx 1 7789841xxx 7789841xxx 7789841xxx 7789841xxx 7789841xxx 7789841xxx 7789841xxx 7789841xxx 7789841xxx 7789841xxx 1 1 1 1 1 1 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity H2012 1 H20 1 R1208 1 H20 1 R1208 1 H20 1 H2012 1 H20 1 R1208 1 H20 1 H20 1 H20 1 H2008 1 H2008 1 H2008 1 A1504M 1 A1504M 1 A15 1 A1504M 1 A1504M 1 A15 1 A1504M 1 A1504M 1 A1504M 1 A1504M 1 Insulated inputs - see page A.66 Type Quantity Insulated outputs - see page A.70 Type Quantity O2012 1 O2008 1 O2008 1 A) Attention! Only use these interfaces: 8537110000 or 0224261001. More information in chapter C B) A ttention! Only use these interfaces: 8233350000. More information in chapter C •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. •Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end. These cables do not have a PLC connector. Colour code according to DIN 47100. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.26 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC SCHNEIDER – M340 Manufacturer code BMX DAI 1602 DI DO BMX DAI 1603 BMX DAI 1604 BMX DDI 1602 BMX DDI 1603 BMX DDI 3202 K BMX DDI 6402 K BMX DAO 1605 BMX DDO 1602 BMX DDO 1612 B) BMX DDO 3202 K BMX DDO 6402 K BMX DRA 0805 BMX DRA 1605 BMX DDM 16022 DI/DO BMX DDM 16025 BMX DDM 3202 K AI AO AI/AO Note BMX AMI 0410 BMX AMI 0410 BMX ART 0414 BMX ART 0814 BMX AMO 0210 BMX AMM 0600 BMX AMM 0600 PLC Cables Input/Output cards Standard Number/Type of channels 16 DI, negative logic A) 16 DI, positive logic 16 DI 16 DI 16 DI 16 DI 32 DI 64 DI 16 DO 16 DO 16 DO 32 DO 64 DO 8 DO 16 DO 8 DI 8 DO 8 DI 8 DO 16 DI 16 DO 4 AI, current applications 4 AI, voltage applications 4 AI 8 AI 2 AO 4 AI + 2 AO, current applications 4 AI + 2 AO, voltage applications Interfaces Direct inputs/outputs Order No. 7789630xxx 7789382xxx 7789382xxx 7789382xxx 7789380xxx 7789382xxx 7789387xxx 7789387xxx 7789383xxx 7789380xxx 7789380xxx 7789387xxx 7789387xxx 7789633xxx 7789384xxx Quantity 1 1 1 1 1 1 1 2 1 1 1 1 2 1 1 7789386xxx 1 7789635xxx 1 7789387xxx 1 7789638xxx 7789637xxx 7789639xxx 7789639xxx 7789640xxx 7789629xxx 7789628xxx 1 1 1 2 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity H2016 1 R2416 1 R2416 1 R2416 1 H2016 1 R2416 1 H2016 2 H2016 2 R2416 1 H2016 1 H2016 1 H2016 2 H2016 4 R2416 1 R2416 1 H2008 1 H2008 1 H2008 1 R1208 1 H2016 1 H2016 1 A1504 1 A1504 1 A3716 1 A3716 2 A1504 1 A1504 2 A1504 2 Insulated inputs - see page A.66 Type Quantity I2016 1 I2016 I2016 2 2 Insulated outputs - see page A.70 Type Quantity O2016 O2016 O2016 O2016 1 1 2 4 O2008 1 O2016 1 A A) Attention! Only use interfaces without LEDs B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.27 Universal solutions for PLC input/ output cards Selection guide PLC SCHNEIDER – MICRO A DI DO TSX DMZ 28AR TSX DMZ 28DR TSX DMZ 28DT TSX DMZ 28DTK TSX DMZ 64DTK AI AO Note Cables Standard Manufacturer code TSX DEZ 08A4 TSX DEZ 08A5 TSX DEZ 12D2 A) TSX DEZ 12D2K TSX DEZ 32D2 TSD DSZ 32R5 TSX DSZ 32T2 TSX DSZ 04T22 TSX DSZ 08R5 TSX DSZ 08T2 TSX DSZ 08T2K TSX DMZ 16DTK DI/DO PLC Input/Output cards TSX AEZ 414 TSX AEZ 801 TSX AEZ 802 TSX ASZ 200 TSX ASZ 401 Number/Type of channels 8 DI 8 DI 12 DI 12 DI 32 DI 32 DI 32 DI 4 DO 16 DO 8 DO 8 DO 8 DI 8 DO 16 DI 12 DO 16 DI 12 DO 16 DI 12 DO 16 DI 12 DO 32 DI 32 DO 4 AI 8 AI 8 AI 2 AO 4 AO Interfaces Direct inputs/outputs Order No. 7789307xxx 7789307xxx 7789312xxx 7789301xxx 7789314xxx 7789330xxx 7789314xxx 7789312xxx 7789308xxx 7789312xxx 7789301xxx Quantity 1 1 1 1 1 1 1 1 1 1 1 7789834xxx 1 7789331xxx 1 7789331xxx 1 7789313xxx 1 7789301xxx 7789301xxx 7789301xxx 7789301xxx 7789309xxx 7789311xxx 7789311xxx 7789310xxx 7789310xxx 1 1 2 2 1 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity R1208 1 R1208 1 H2016 1 H2012 1 H2016 2 R3632 1 H2016 2 H2008 1 R2416 1 H2008 1 H2008 1 H2008 1 H2008 1 R2416 1 R2416 1 R2416 1 R2416 1 H2016 1 H2016 1 H2016 1 H2012 1 H2016 2 H2016 2 A1504 1 A2508 1 A2508 1 A1504 1 A1504 1 Insulated inputs - see page A.66 Type Quantity I2016 2 I2016 2 Insulated outputs - see page A.70 Type Quantity O2008 1 O2008 O2008 1 1 O2008 1 O2016 1 O2012 1 O2016 2 A) Attention! Only use interfaces without LEDs •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.28 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC SCHNEIDER – PREMIUM DI DO AI AO Note PLC Cables Input/Output cards Standard Manufacturer code TSX DEY 08D2 TSX DEY 16A2 TSX DEY 16A3 TSX DEY 16A4 TSX DEY 16A5 TSX DEY 16D2 TSX DEY 16D3 TSX DEY 16FK TSX DEY 32D2K TSX DEY 64D2K TSX DSY 08R4D TSX DSY 08R5 TSX DSY 08R5A TSX DSY 08S5 TSX DSY 08T2 TSX DSY 08T22 TSX DSY 08T31 TSX DSY 16R5 TSX DSY 16S4 TSX DSY 16T2 TSX DSY 16T3 A) TSX DSY 32T2K TSX DSY 64T2K TSX AEY 1600 TSZ AEY 414 TSX AEY 414 TSX AEY 420 TSX AEY 800 TSX AEY 810 TSX ASY 410 TSX ASY 410 TSX ASY 800 Number/Type of channels 8 DI 16 DI 16 DI 16 DI 16 DI 16 DI 16 DI 16 DI 32 DI 64 DI 8 DO 8 DO 8 DO 8 DO 8 DO 8 DO 8 DO 16 DO 16 DO 16 DO 16 DO 32 DO 64 DO 16 AI 4 AI, resistances applications 4 AI, current and voltage applications 4 AI 8 AI 8 AI 4 AO, current applications 4 AO, voltage applications 8 AO Interfaces Direct inputs/outputs - see page A.38 (H) or A.60 (A) Type Quantity H2008 1 R2416 1 R2416 1 R2416 1 R2416 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 4 R2416 1 R2416 1 R2416 1 R2416 1 H2008 1 R1208 1 R1208 1 R2416 1 R2416 1 H2016 1 H2016 1 H2016 2 H2016 4 A2508P 2 A2508P 1 Order No. 7789322xxx 7789315xxx 7789315xxx 7789315xxx 7789315xxx 7789322xxx 7789322xxx 7789301xxx 7789301xxx 7789301xxx 7789318xxx 7789316xxx 7789318xxx 7789316xxx 7789322xxx 7789317xxx 7789317xxx 7789316xxx 7789316xxx 7789322xxx 7789322xxx 7789301xxx 7789301xxx 7789259xxx 7789319xxx Quantity 1 1 1 1 1 1 1 1 2 4 1 1 1 1 1 1 1 1 1 2 4 2 4 2 1 7789320xxx 1 A1504 1 7789259xxx 7789259xxx 7789261xxx 7789320xxx 7789321xxx 7789259xxx 1 1 1 1 1 1 A2508P A2508P A2508P A1504 A1504 A2508P 1 1 1 1 1 1 Insulated inputs - see page A.66 Type Quantity I2016 I2016 I2016 I2016 I2016 Insulated outputs - see page A.70 Type Quantity A 1 1 1 2 4 O2008 1 O2016 1 O2016 O2016 2 4 A) Attention! Only use interfaces without LEDs •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.29 Universal solutions for PLC input/ output cards Selection guide PLC SCHNEIDER – QUANTUM A DI DO DI/DO 140 DDM 390 00 140 AII 330 00 140 ARI 030 10 AO Note Cables Standard Manufacturer code 140 DAI 340 00 140 DAI 353 00 140 DAI 440 00 140 DAI 453 00 140 DAI 540 00 140 DAI 553 00 140 DAI 740 00 140 DDI 353 00 140 DDI 364 00 140 DDI 841 00 140 DDI 853 00 140 DAO 840 00 140 DAO 842 10 140 DDO 353 00 140 DDO 364 00 140 DDO 843 00 140 DRA 840 00 140 ACI 030 00 140 ACI 030 00 140 ACI 040 00 AI PLC Input/Output cards 140 AVI 030 00 140 AVI 030 00 140 ACO 020 00 140 ACO 130 00 140 AIO 330 00 Number/Type of channels 16 DI 32 DI 16 DI 32 DI 16 DI 32 DI 16 DI 32 DI 96 DI 16 DI 32 DI 16 DO 16 DO 32 DO 96 DO 16 DO 16 DO 16 DI 8 DO 8 AI, current applications 8 AI, voltage applications 16 AI 8 AI, 2-wire resistances applications 8 AI, 2-wire resistances applications 8 AI, current applications 8 AI, voltage applications 4 AO 8 AO, without monitoring 8 AIO Order No. 7789118xxx 7789118xxx 7789118xxx 7789118xxx 7789118xxx 7789118xxx 7789118xxx 7789121xxx 7789301xxx 7789119xxx 7789121xxx 7789118xxx 7789113xxx 7789121xxx 7789301xxx 7789120xxx 7789118xxx Interfaces Direct inputs/outputs Quantity 1 1 1 1 1 1 1 1 6 1 1 1 1 1 6 1 1 - see page A.38 (H) or A.60 (A) Type Quantity R3632 1 R3632 1 R3632 1 R3632 1 R3632 1 R3632 1 R3632 1 H2016 2 H2016 6 H2016 1 H2016 2 R3632 1 R2416 1 H2016 2 H2016 6 H2016 1 R3632 1 H2016 1 H2008 1 A2508 1 A2508 1 A3716 1 7789133xxx 1 7789125xxx 7789134xxx 7789123xxx 1 1 1 7789136xxx 1 A2508 1 7789135xxx 1 A2508 1 7789125xxx 7789134xxx 7789124xxx 7789126xxx 7789137xxx 1 1 1 1 1 A2508 A2508 A1504 A2508 A2508 1 1 1 1 1 Insulated inputs - see page A.66 Type Quantity I2016 I2016 I2016 I2016 Insulated outputs - see page A.70 Type Quantity 2 6 1 2 O2016 O2016 O2016 2 6 1 O2008 1 •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.30 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC SCHNEIDER – TWIDO DI DO TWD LMDA 20DRT C) TWD LMDA 20DTK TWD LMDA 20DUK D) TWD LMDA 40DTK TWD LMDA 40DUK D) AI AO AI/AO Note Cables Standard Manufacturer code TWD DDI 16DK TWD DDI 16DT TWD DDI 16DT A) TWD DII 32DK TWD DDI 8DT TWD DDI 8DT A) TWD DDO 16TK TWD DDO 16UK B) TWD DDO 32TK TWD DDO 32UK B) TWD DDO 8TT TWD DDO 8UT A) TWD DRA 16RT TWD DRA 8RT TWD LMDA 20DRT DI/DO PLC Input/Output cards TWD AMI 2HT TWD AMO 1HT TWD ALM 3LT TWD AMM 3HT Number/Type of channels 16 DI, positive logic 16 DI, positive logic 16 DI, negative logic 32 DI 8 DI, positive logic 8 DI, negative logic 16 DO 16 DO 32 DO 32 DO 8 DO 8 DO 16 DO 8 DO 12 DI, positive logic 8 DO 12 DI, negative logic 8 DO 12 DI, positive logic 8 DO 12 DI, positive logic 8 DO 24 DI, positive logic 16 DO 24 DI, positive logic 16 DO 2 AI 1 AI 2 AI 1 AO 2 AI 1 AO Interfaces Order No. 7789328xxx 7789100xxx 7789100xxx 7789328xxx 7789100xxx 7789100xxx 7789329xxx 7789328xxx 7789329xxx 7789328xxx 7789100xxx 7789100xxx 7789104xxx 7789108xxx 7789100xxx 7789104xxx 7789100xxx 7789104xxx Quantity 1 1 1 2 1 1 1 1 2 2 1 1 1 1 1 7789327xxx 1 7789326xxx 1 7789327xxx 2 7789326xxx 2 7789250xxx 7789250xxx 1 1 7789250xxx 1 7789250xxx 1 1 Direct inputs/outputs Insulated inputs - see page A.38 (H) or A.60 (A) Type Quantity H2016 1 H2016 1 H2016 1 H2016 2 H2008 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 H2008 1 H2016 1 R2416 1 R1208 1 H2012 1 R2416 1 H2016 1 R2416 1 H2012 1 H2016 1 H2012 1 H2016 1 H2012 2 H2016 2 H2012 2 H2008 2 A1504 1 A1504 1 1 A1504 1 1 A1504 1 - see page A.66 Type Quantity I2016 1 I2016 1 I2016 I2016 Insulated outputs - see page A.70 Type Quantity A 2 1 O2016 O2016 O2016 O2016 O2008 1 1 2 2 1 O2016 1 H2008 2 A) Attention! Only use interfaces without LEDs B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option C) Attention! Use only interfaces without LEDs for the direct input option D) Attention! Use only interfaces without LEDs for the direct output option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated outlet option •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. •Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end. These cables do not have a PLC connector. Colour code according to DIN 47100. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.31 Universal solutions for PLC input/ output cards Selection guide PLC SIEMENS – S7-200 A DI DO PLC Cables Input/Output cards Standard Manufacturer code 6ES7221-1BF22-0XA0 6ES7221-1BH22-0XA0 6ES7221-1EF22-0XA0 6ES7222-1BD22-0XA0 6ES7222-1BF22-0XA0 6ES7222-1EF22-0XA0 6ES7222-1HD22-0XA0 6ES7223-1BF22-0AX0 6ES7223-1BH22-0XA0 6ES7223-1BL22-0XA0 DI/DO 6ES7223-1BM22-0XA0 6ES7223-1HF22-0XA0 6ES7223-1PH22-0XA0 6ES7223-1PL22-0XA0 6ES223-1PM22-0XA0 AI AO AI/AO Note 6ES7231-0HC22-0XA0 6ES7231-0HF22-0XA0 6ES7232-0HB22-0XA0 6ES7232-0HD22-0XA0 6ES7235-0KD22-0XA0 Number/Type of channels 8 DI 16 DI 8 DI 4 DO 8 DO 8 DO 8 DO 4 DI 4 DO 8 DI 8 DO 16 DI 16 DO 32 DI 32 DO 4 DI 4 DO 8 DI 8 DO 16 DI 16 DO 32 DI 32 DO 4 AI 8 AI 2 AO 4 AO 4 AI / 1 AO Interfaces Direct inputs/outputs Order No. 7789100xxx 7789100xxx 7789104xxx 7789100xxx 7789100xxx 7789104xxx 7789104xxx Quantity 1 1 1 1 1 1 1 7789100xxx 2 7789100xxx 2 7789100xxx 2 7789100xxx 4 7789100xxx 7789108xxx 7789100xxx 7789108xxx 7789100xxx 7789104xxx 7789100xxx 7789104xxx 7789250xxx 7789252xxx 7789250xxx 7789250xxx 7789252xxx 1 1 1 1 1 1 2 2 1 1 1 1 1 - see page A.38 (H) or A.60 (A) Type Quantity H2008 1 H2016 1 R2416 1 H2008 1 H2008 1 R2416 1 R2416 1 H2008 1 H2008 1 H2008 1 H2008 1 H2016 1 H2016 1 H2016 2 H2016 2 H2008 1 R1208 1 H2008 1 R1208 1 H2016 1 R2416 1 H2016 2 R2416 2 A1504 1 A2508 1 A1504 1 A1504 1 A2508 1 Insulated inputs - see page A.66 Type Quantity I2016 Insulated outputs - see page A.70 Type Quantity 1 O2008 O2008 1 1 O2008 1 O2008 1 O2016 1 O2016 2 •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. •Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end. These cables do not have a PLC connector. Colour code according to DIN 47100. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.32 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC SIEMENS – S7-300/ET- 200M PLC Cables Input/Output cards Standard Manufacturer code 6ES7321-1BH00-0AA0 6ES7321-1BH01-0AA0 6ES7321-1BH02-0AA0 6ES7321-1BH50-0AA0 6ES7321-1BH80-0AA0 6ES7321-1BH81-0AA0 6ES7321-1BH82-0AA0 6ES7321-1BL00-0AA0 6ES7321-1BL80-0AA0 6ES7321-1BP00-0AA0 DI DO 6ES7321-1CH20-0AA0 6ES7321-1CH80-0AA0 6ES7321-1EH00-0AA0 6ES7321-1EH01-0AA0 6ES7321-1EL00-0AA0 6ES7321-1FF00-0AA0 6ES7321-1FF01-0AA0 6ES7321-1FF81-0AA0 6ES7321-1FH00-0AA0 6ES7321-7BH00-0AB0 A) 6ES7321-7BH01-0AB0 A) 6ES7321-7BH80-0AB0 A) 6ES7321-7RD00-0AB0 B) 6ES7322-1BF00-0AA0 6ES7322-1BF01-0AA0 6ES7322-1BH00-0AA0 6ES7322-1BH01-0AA0 6ES7322-1BH10-0AA0 6ES7322-1BH81-0AA0 6ES7322-1BL00-0A00 6ES7322-1BP00-0AA0 6ES7322-1BP50-0AA0 C) 6ES7322-1CF00-0AA0 6ES7322-1CF80-0AA0 6ES7322-1EH00-0AA0 6ES7322-1EH01-0AA0 6ES7322-1EL00-0AA0 6ES7322-1FF00-0AA0 6ES7322-1FF01-0AA0 6ES7322-1FF81-0AA0 6ES7322-1FH00-0AA0 6ES7322-1FL00-0AA0 6ES7322-1HF80-0AA0 6ES7322-5RD00-0AB0 D) 6ES7322-5SD00-0AB0 D) 6ES7322-8BF00-0AB0 6ES7322-8BF00-0AB0 6ES7322-8BH01-0AB0 6ES7322-8BH01-0AB0 6ES7323-1BH00-0A00 6ES7323-1BH01-00A0 DI/DO 6ES7323-1BH80-0AA0 6ES7323-1BH80-0A00 6ES7323-1BL00-0AA0 1327330000 – 2012/2013 Number/Type of channels 16 DI 16 DI 16 DI 16 DI 16 DI 16 DI 16 DI 32 DI 32 DI 64 DI, positive logic 64 DI, negative logic A) 16 DI 16 DI 16 DI 16 DI 16 DI 8 DI 8 DI 8 DI 16 DI 16 DI 16 DI 16 DI 16 DI 8 DO 8 DO 16 DO 16 DO 16 DO 16 DO 32 DO 64 DO 64 DO 8 DO 8 DO 16 DO 16 DO 32 DO 8 DO 8 DO 8 DO 16 DO 32 DO 8 DO 4 DO 4 DO 8 DO, without redundancy 8 DO, with redundancy 16 DO, without redundancy 16 DO, with redundancy 8 DI 8DO 8 DI 8 DO 8 DI 8 DO 8 DI 8 DO 16 DI 16 DO Interfaces Order No. 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789236xxx 7789236xxx 7789771xxx 7789768xxx 7789211xxx 7789211xxx 7789212xxx 7789212xxx 7789215xxx 7789219xxx 7789219xxx 7789219xxx 7789212xxx 7789210xxx 7789210xxx 7789210xxx 7789801xxx 7789239xxx 7789239xxx 7789234xxx 7789234xxx 7789234xxx 7789234xxx 7789236xxx 7789246xxx 7789246xxx 7789191xxx 7789191xxx 7789211xxx 7789211xxx 7789211xxx 7789219xxx 7789219xxx 7789219xxx 7789211xxx 7789211xxx 7789190xxx 7789192xxx 7789192xxx 7789239xxx 7789830xxx 7789729xxx 7789730xxx Quantity 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 2 1 1 1 1 2 1 1 1 1 1 1 1 7789237xxx 1 7789237xxx 1 7789237xxx 1 7789237xxx 1 7789236xxx 1 Direct inputs/outputs Insulated inputs - see page A.38 (H) or A.60 (A) Type Quantity H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 2 H2016 4 H2016 4 R2416 1 R2416 1 R2416 1 R2416 1 R3632 1 R1208 1 R1208 1 R1208 1 R2416 1 R2416 1 R2416 1 R2416 1 H20 1 H2008 1 H2008 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 2 H2016 4 H2016 4 R1208 1 R1208 1 R2416 1 R2416 1 R2416 2 R1208 1 R1208 1 R1208 1 R2416 1 R2416 2 R2416 1 H2016 1 H2016 1 H2008 1 H2008 1 H2016 1 H2016 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2008 1 H2016 1 H2016 1 - see page A.66 Type Quantity I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 2 I2016 2 I2016 4 I2016 Insulated outputs - see page A.70 Type Quantity O2008 O2008 O2016 O2016 O2016 O2016 O2016 O2016 O2016 1 1 1 1 1 1 2 4 4 O2008 O2008 O2016 O2016 1 1 1 1 O2008 1 O2008 1 O2008 1 O2008 1 O2016 1 A 1 A.33 Universal solutions for PLC input/ output cards Selection guide PLC SIEMENS – Siemens S7-300 / ET- 200M A AI AO AI/AO PLC Cables Input/Output cards Standard Manufacturer code 6ES7331-1KF01-0AB0 6ES7331-1KF02-0AB0 6ES7331-7KB00-0AB0 6ES7331-7KB01-0AB0 6ES7331-7KB02-0AB0 6ES7331-7KF00-0AB0 6ES7331-7KF01-0AB0 6ES7331-7KF02-0AB0 6ES7331-7NF00-0AB0 6ES7331-7PF00-0AB0 6ES7331-7PF00-0AB0 E) 6ES7331-7PF01-0AB0 6ES7331-7PF01-0AB0 E) 6ES7331-7RD00-0AB0 6ES7331-7RD00-0AB0 6ES7331-7TF01-0AB0 6ES7331-7TF01-0AB0 6ES7332-5HB00-0AB0 6ES7332-5HB00-0AB0 B) 6ES7332-5HB00-0AB0 6ES7332-5HB01-0AB0 6ES7332-5HB01-0AB0 B) 6ES7332-5HB01-0AB0 6ES7332-5HB81-0AB0 6ES7332-5HB81-0AB0 B) 6ES7332-5HB81-0AB0 6ES7332-5HD00-0AB0 6ES7332-5HD00-0AB0 B) 6ES7332-5HD00-0AB0 6ES7332-5HD01-0AB0 6ES7332-5HD01-0AB0 B) 6ES7332-5HD01-0AB0 6ES7332-5HF00-0AB0 6ES7332-5HF00-0AB0 B) 6ES7332-5RD00-0AB0 6ES7332-7ND01-0AB0 6ES7332-7ND01-0AB0 B) 6ES7332-7ND01-0AB0 6ES7332-7ND02-0AB0 6ES7332-7ND02-0AB0 B) 6ES7332-7ND02-0AB0 6ES7334-0CE01-0AA0 6ES7334-0KE00-0AB0 6ES7335-7HG01-0AB0 6ES7335-7HG02-0AB0 6ES7312-5BD00-0AB0 6ES7312-5BD01-0AB0 6ES7312-5BE03-0AB0 CPU 6ES7313-5BE00-0AB0 6ES7313-5BE01-0AB0 A.34 Number/Type of channels 8 AI 8 AI 2 AI 2 AI 2 AI 8AI 8 AI 8 AI 8 AI 8 AI, 2-wire applications 8 AI, 3 and 4-wire applications 8 AI, 2-wire applications 8 AI, 3 and 4-wire applications 4 AI, 2-wire applications 4 AI, 4-wire applications 8 AI, 2-wire applications 8 AI, 4-wire applications 2 AO, 2-wire voltage applications 2 AO, 4-wire voltage applications 2 AO, current applications 2 AO, 2-wire voltage applications 2 AO, 4-wire voltage applications 2 AO, current applications 2 AO, 2-wire voltage applications 2 AO, 4-wire voltage applications 2 AO, current applications 4 AO, 2-wire voltage applications 4 AO, 4-wire voltage applications 4 AO, current applications 4 AO, 2-wire voltage applications 4 AO, 4-wire voltage applications 4 AO, current applications 8 AO, voltage applications 8 AO, current applications 4 AO 4 AO, 2-wire voltage applications 4 AO, 4-wire voltage applications 4 AO, current applications 4 AO, 2-wire voltage applications 4 AO, 4-wire voltage applications 4 AO, current applications 4 AI + 2 AO 4 AI + 2 AO 4 AI + 2 AO 4 AI + 2 AO 10 DI 6 DO 10 DI 6 DO 10 DI 6 DO 16 DI 16 DO 8 DI 5 AI + 2 AO 16 DI 16 DO 8 DI 5 AI + 2 AO Interfaces Direct inputs/outputs Order No. 7789604xxx 7789604xxx 7789224xxx 7789224xxx 7789224xxx 7789229xxx 7789229xxx 7789229xxx 7789231xxx 7789230xxx 7789759xxx 7789230xxx 7789759xxx 7789193xxx 7789194xxx 7789229xxx 7789800xxx 7789228xxx 7789801xxx 7789227xxx 7789228xxx 7789801xxx 7789227xxx 7789228xxx 7789801xxx 7789227xxx 7789228xxx 7789801xxx 7789227xxx 7789228xxx 7789801xxx 7789227xxx 7789759xxx 7789233xxx 7789195xxx 7789228xxx 7789801xxx 7789227xxx 7789228xxx 7789801xxx 7789227xxx 7789225xxx 7789196xxx 7789226xxx 7789226xxx Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7789221xxx 1 7789221xxx 1 7789221xxx 1 7789222xxx 1 7789223xxx 1 7789222xxx 1 7789223xxx 1 - see page A.38 (H) or A.60 (A) Type Quantity A3716 1 A3716 1 A1504 1 A1504 1 A1504 1 A2508 1 A2508 1 A2508 1 A3716 1 A2508 1 H40 1 A2508 1 H40 1 A1504 1 A2508 1 A2508 1 A2508 1 A1504 1 H20 1 A1504 1 A1504 1 H20 1 A1504 1 A1504 1 H20 1 A1504 1 A1504 1 H20 1 A1504 1 A1504 1 H20 1 A1504 1 H40 1 A2508 1 A1504 1 A1504 1 H20 1 A1504 1 A1504 1 H20 1 A1504 1 A3716 1 A2508 1 A3716 1 A3716 1 H2012 1 H2008 1 H2012 1 H2008 1 H2012 1 H2008 1 H2016 1 H2016 1 H2008 1 A2508P 1 H2016 1 H2016 1 H2008 1 A2508P 1 Insulated inputs - see page A.66 Type Quantity I2016 Insulated outputs - see page A.70 Type Quantity O2008 1 O2008 1 O2008 1 O2016 1 O2016 1 1 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC Siemens S7-300 / ET- 200M PLC Cables Input/Output cards Standard Manufacturer code 6ES7313-5BF03-0AB0 6ES7313-6BE00-0AB0 6ES7313-6BE01-0AB0 6ES7313-6BF03-0AB0 6ES7313-6CE00-0AB0 6ES7313-6CE01-0AB0 6ES7313-6CF03-0AB0 6ES7314-6BF00-0AB0 CPU 6ES7314-6BF01-0AB0 6ES7314-6BF02-0AB0 6ES7314-6CF00-0AB0 6ES7314-6CF01-0AB0 6ES7314-6CF02-0AB0 Note Number/Type of channels 16 DI 16 DO 8 DI 5 AI + 2 AO 16 DI 16 DO 16 DI 16 DO 16 DI 16 DO 16 DI 16 DO 16 DI 16 DO 16 DI 16 DO 16 DI 16 DO 8 DI 5 AI + 2 AO 16 DI 16 DO 8 DI 5 AI + 2 AO 16 DI 16 DO 8 DI 5 AI + 2 AO 16 DI 16 DO 8 DI 5 AI + 2 AO 16 DI 16 DO 8 DI 5 AI + 2 AO 16 DI 16 DO 8 DI 5 AI + 2 AO Interfaces Order No. Quantity 7789222xxx 1 7789223xxx 1 7789222xxx 1 7789222xxx 1 7789222xxx 1 7789222xxx 1 7789222xxx 1 7789222xxx 1 7789222xxx 1 7789223xxx 1 7789222xxx 1 7789223xxx 1 7789222xxx 1 7789223xxx 1 7789222xxx 1 7789223xxx 1 7789222xxx 1 7789223xxx 1 7789222xxx 1 7789223xxx 1 Direct inputs/outputs Insulated inputs - see page A.38 (H) or A.60 (A) Type Quantity H2016 1 H2016 1 H2008 1 A2508P 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2016 1 H2008 1 A2508P 1 H2016 1 H2016 1 H2008 1 A2508P 1 H2016 1 H2016 1 H2008 1 A2508P 1 H2016 1 H2016 1 H2008 1 A2508P 1 H2016 1 H2016 1 H2008 1 A2508P 1 H2016 1 H2016 1 H2008 1 A2508P 1 - see page A.66 Type Quantity I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 1 I2016 I2016 I2016 I2016 I2016 Insulated outputs - see page A.70 Type Quantity O2016 1 O2016 1 O2016 1 O2016 1 O2016 1 O2016 1 O2016 1 O2016 1 O2016 1 O2016 1 O2016 1 O2016 1 O2016 1 A 1 1 1 1 1 A) Attention! Only use interfaces without LEDs B) Attention! Only use these interfaces: 8537110000 or 0224261001. More information in chapter C C) Attention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option D) This is not an ATEX solution. The interface cannot have LEDs, fuses, disconnectors or test points E) Attention! Only use these interfaces: 8537140000 or 0224461001. More information in chapter C •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. *In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.35 Universal solutions for PLC input/ output cards Selection guide PLC SIEMENS – S7-400 A DI DO AI Note AO PLC Cables Input/Output cards Standard Manufacturer code 6ES7421-1BL00-0AA0 6ES7421-1BL01-0AA0 6ES7421-1EL00-0AA0 6ES7421-1FH00-0AA0 6ES7421-1FH20-0AA0 6ES7421-7BH00-0AB0 6ES7421-7BH01-0AB0 6ES7421-7DH00-0AB0 6ES7422-1BH10-0AA0 6ES7422-1BH11-0AA0 6ES7422-1BL00-0AA0 6ES7422-1FF00-0AA0 6ES7422-1FH00-0AA0 6ES7422-1HH00-0AA0 6ES7422-5EH10-0AB0 6ES7422-7BL00-0AB0 6ES7431-0HH00-0AB0 6ES7431-1KF00-0AB0 6ES7431-1KF00-0AB0 6ES7431-1KF10-0AB0 6ES7431-1KF20-0AB0 6ES7431-7KF10-0AB0 6ES7431-7QH00-0AB0 6ES7432-1HF00-0AB0 Number/Type of channels 32 DI 32 DI 32 DI 16 DI 16 DI 16 DI 16 DI 16 DI 16 DO 16 DO 32 DO 8 DO 16 DO 16 DO 16 DO 32 DO 16 AI 8 AI, voltage and resistance applications 8 AI, current applications 8 AI 8 AI 16 AI 16 AI 8 AO, 8 AO, common mode voltage applications Order No. 7789292xxx 7789292xxx 7789278xxx 7789273xxx 7789273xxx 7789290xxx 7789290xxx 7789278xxx 7789291xxx 7789291xxx 7789292xxx 7789283xxx 7789273xxx 7789270xxx 7789291xxx 7789292xxx 7789284xxx 7789286xxx 7789287xxx 7789285xxx 7789285xxx 7789284xxx 7789284xxx 7789288xxx Interfaces Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Direct inputs/outputs Insulated inputs - see page A.38 (H) or A.60 (A) Type Quantity H2016 2 H2016 2 R3632 1 R2416 1 R2416 1 H2016 2 H2016 2 R3632 1 H2016 1 H2016 1 H2016 2 R1208 1 R2416 1 R3632 1 H2016 1 H2016 2 A3716 1 A2508 1 A2508 1 A2508 1 A2508 1 A3716 1 A3716 1 A2508 1 - see page A.66 Type Quantity H2016 2 H2016 2 H2016 H2016 Insulated outputs - see page A.70 Type Quantity 2 2 O2016 O2016 O2016 1 1 2 O2016 O2016 1 2 •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. * In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. A.36 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards Selection guide PLC SIEMENS – S7-1200 DI DO PLC Cables Input/Output cards Standard Manufacturer code 6ES7221-1BF30-0XB0 6ES7221-1BH30-0XB0 6ES7222-1HF30-0XB0 6ES7222-1HH30-0XB0 6ES7222-1BF30-0XB0 6ES7222-1BH30-0XB0 6ES7223-1PH30-0XB0 DI/DO 6ES7223-1PL30-0XB0 6ES7223-1BH30-0XB0 6ES7223-1BL30-0XB0 AI AO AI/AO 6ES7231-4HD30-0XB0 6ES7231-4HF30-0XB0 6ES7232-4HB30-0XB0 6ES7232-4HD30-0XB0 6ES7234-4HE30-0XB0 Note Number/Type of channels 8 DI 16 DI 8 DO 16 DO 8 DO 16 DO 8 DI 8 DO 16 DI 16 DO 8 DI 8 DO 16 DI 16 DO 4 AI 8 AI 2 AO 4 AO 4 AI 2 AO Interfaces Direct inputs/outputs Order No. 1329110xxx 1329120xxx 1329130xxx 1329140xxx 1329150xxx 1329170xxx 1329180xxx 1329190xxx 1329200xxx 1329210xxx 1329180xxx 1329230xxx 1329200xxx 1329240xxx 1329250xxx 1329270xxx 1329280xxx 1329290xxx Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1329300xxx 1 - see page A.38 (H) or A.60 (A) Type Quantity H2008 1 H2016 1 R1208 1 R2416 1 H2008 1 H2016 1 H2008 1 R1208 1 H2016 1 R2416 1 H2008 1 H2008 1 H2016 1 H2016 1 A1504 1 A2508 1 A1504 1 A1504 1 A2508 Insulated inputs - see page A.66 Type Quantity Insulated outputs - see page A.70 Type Quantity A H2016 O2008 O2016 1 1 O2008 1 O2016 1 1 •Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at higher voltages than those indicated in the interface. •The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long. *In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will always find the most up-to-date information. 1327330000 – 2012/2013 A.37 Universal solutions for PLC input/ output cards Selection guide A RS IO – Selection guide for passive interfaces for digital signals Type Family Type of wiring 8-channel H2008 R1208 2-wire 2-wire 12-channel H2012 2-wire Number of channels Connection Screw Tension clamp connection L 9445630000 RS 12IO 2W L H S A.42 V V L 9445700000 9445710000 1311750000 1311770000 9445810000 1311780000 9445720000 9445730000 1311790000 1311800000 1311810000 9445750000 1311820000 1311830000 9445820000 1311850000 1311840000 1311870000 9445760000 9445770000 1311880000 1311890000 9441500000 9441860000 9441700000 9441560000 9441600000 RS 16IO 1W H S RS 16IO 1W L H S RS 16IO 1W H Z RS 16IO 1W L H Z RS 16IO 1W I-L H S RS 16IO 1W I-L H Z RS 16IO 2W H S RS 16IO 2W L H S RS 16IO 2W H Z RS 16IO 2W L H Z RS 16IO 2W I H S RS 16IO 2W I-L H S RS 16IO 2W I H Z RS 16IO 2W I-L H Z RS 16IO 2W F H S RS 16IO 2W F-L H S RS 16IO 2W F H Z RS 16IO 2W F-L H Z RS 16IO 3W H S RS 16IO 3W L H S RS 16IO 3W H Z RS 16IO 3W L H Z RS 16IO 1W R S RS 16IO 1W I R S RS 16IO 2W R S RS 16IO 2W F R S RS 16IO 3W I R S A.43 A.43 A.43 A.43 A.44 A.44 A.45 A.45 A.45 A.45 A.46 A.46 A.46 A.46 A.47 A.47 A.47 A.47 A.48 A.48 A.48 A.48 A.49 A.49 A.50 A.50 A.51 9445900000 9445910000 9445870000 9445930000 9445950000 9445980000 9445960000 9445970000 9441510000 9441870000 9441710000 9441570000 9441610000 RS 32IO 1W H S RS 32IO 1W L H S RS 32IO 1W I-L H S RS 32IO 2W L H S RS 32IO 2W I-L H S RS 32IO 2W F H S RS 32IO 3W H S RS 32IO 3W L H S RS 32IO 1W R S RS 32IO 1W I R S RS 32IO 2W R S RS 32IO 2W F R S RS 32IO 3W I R S A.52 A.52 A.53 A.54 A.54 A.55 A.56 A.56 A.57 A.57 A.58 A.58 A.59 Z Z V V Z Z H2032 32-channel 2-wire 3-wire 1-wire R3632 A.38 2-wire 3-wire L I I I I F F F F L V V L L Z Z L V V V V V V V V V V V V V V V V V V I I L L Z Z 1-wire L L L L V V 3-wire Page V 16-channel 2-wire Interfaces A.40 A.41 Z Z R2416 Type RS 8IO 2W L H S RS 8IO 2W R S V V 1-wire Order No. 9445530000 9441540000 Z 3-wire Fuse L V 2-wire Disconnectable V V 1-wire H2016 Features LED by channel I F I L L L L I I F L I F I Note 1: Coding of the interface descriptions RS 8IO: 8 inputs/outputs 1W:1-wire 12IO: 12 inputs/outputs 2W:2-wire 16IO: 16 inputs/outputs 3W:3-wire 32IO: 32 inputs/outputs Number of wires Note 2: 2 units of the following products from the H2016 family can be replaced by 1 unit from the H2032 family 9445700000 9445710000 9445810000 9445730000 9445750000 9445820000 9445760000 9445770000 RS 16IO 1W H S RS 16IO 1W L H S RS 16IO 1W I-L H S RS 16IO 2W L H S RS 16IO 2W I-L H S RS 16IO 2W F H S RS 16IO 3W H S RS 16IO 3W L H S 2 units 2 units 2 units 2 units 2 units 2 units 2 units 2 units (empty): Direct H HE connector (ribbon cable) S: Screw I: Switch R: RSV connector Z: Tension clamp connection L: LED F: Fuse I-L Switch + LED F-L: Fuse + LED 9445900000 9445910000 9445870000 9445930000 9445950000 9445980000 9445960000 9445970000 RS 32IO 1W H S RS 32IO 1W L H S RS 32IO 1W I-L H S RS 32IO 2W L H S RS 32IO 2W I-L H S RS 32IO 2W F H S RS 32IO 3W H S RS 32IO 3W L H S 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1327330000 – 2012/2013 A 1327330000 – 2012/2013 A.39 Universal solutions for PLC input/ output cards Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals A RS IO - Interface for 8 digital signals 2-wire H (HE connector) system RS 8IO 2W L H H system, 2 wires with LED Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug green yellow No 3.15 A No 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 74 mm / 87 mm Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note The common C may carry up to 3 A if the external jumpers are not used Ordering data Screw connection with LED Type RS 8IO 2W L H S Height 72 mm Order No. 9445530000 Note Accessories Note A.40 1327330000 – 2012/2013 RS IO - Interface for 8 digital signals 2-wire R system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS 8IO 2W R R system, 2 wires A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Connector RSV 1.6 12-pole socket No No No 3.15 A No 250 V UC 1A 24 V DC ± 10% 3A -25...+50°C -40...+60 °C CE; GOSTME25 < 250 V AC II 2 2.1 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 68 mm / 87 mm Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note The common C may carry up to 3 A if the external jumpers are not used Ordering data Screw connection without LED Type RS 8IO 2W R S Height 72 mm Order No. 9441540000 Note Accessories Note 1327330000 – 2012/2013 A.41 Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS IO - Interface for 12 digital signals 2-wire H system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 12IO 2W L H H system, 2 wires with LED A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug green yellow No 3.15 A No 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 95 mm / 87 mm Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note The common C may carry up to 3 A if the external jumpers are not used Ordering data Screw connection with LED Type RS 12IO 2W L H S Height 72 mm Order No. 9445630000 Note Accessories Note A.42 1327330000 – 2012/2013 RS IO - Interface for 16 digital signals 1-wire H system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 16IO 1W H RS 16IO 1W L H H system, 1 wire H system, 1 wire with LED Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug No yellow No 3.15 A No Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug green yellow No 3.15 A No 25 V AC / 50 V DC 1A 24 V DC ± 10% 2A 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE; GOSTME25 -25...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 46 mm / 87 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 46 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 46 mm / 87 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 46 mm / 87 mm Ordering data Screw connection without LED Screw connection with LED Tension-clamp connection without LED Tension-clamp connection with LED Note Type RS 16IO 1W H S Height 72 mm Order No. 9445700000 RS 16IO 1W H Z 72 mm 1311750000 Type Height Order No. RS 16IO 1W L H S 72 mm 9445710000 RS 16IO 1W L H Z 72 mm 1311770000 Accessories Note 1327330000 – 2012/2013 A.43 Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS IO - Interface for 16 digital signals 1-wire H system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 16IO 1W I-L H H system, 1 wire with LED and disconnection per channel A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug green yellow No 3.15 A No 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 110 mm / 87 mm Tension clamp connection 0.14 mm² / 1.5 mm² 0.14 mm² / 1.5 mm² TS 32, TS 35 110 mm / 87 mm Ordering data Screw connection without LED Screw connection with LED Tension-clamp connection without LED Tension-clamp connection with LED Note Type Height Order No. RS 16IO 1W I-L H S 72 mm 9445810000 RS 16IO 1W I-L H Z 72 mm 1311780000 Accessories Note A.44 1327330000 – 2012/2013 RS IO - Interface for 16 digital signals 2-wire H system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 16IO 2W H RS 16IO 2W L H H system, 2 wires H system, 2 wires with LED Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug No yellow No 3.15 A No Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug green yellow No 3.15 A No 25 V AC / 50 V DC 1A 24 V DC ± 10% 2A 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE; GOSTME25 -25...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 87 mm / 87 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 87 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 87 mm / 87 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 87 mm / 87 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type RS 16IO 2W H S Height 72 mm Order No. 9445720000 Type Height Order No. 72 mm 72 mm 1311790000 RS 16IO 2W L H S RS 16IO 2W H Z 9445730000 RS 16IO 2W L H Z 72 mm 1311800000 Ordering data Screw connection without LED Screw connection with LED Tension-clamp connection without LED Tension-clamp connection with LED Note Accessories Note 1327330000 – 2012/2013 A.45 Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS IO - Interface for 16 digital signals 2-wire H system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 16IO 2W I H RS 16IO 2W I L H H system, 2 wires with disconnection per channel H system, 2 wires with LED and disconnection per channel A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug No yellow No 3.15 A No Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug green yellow No 3.15 A No 25 V AC / 50 V DC 1A 24 V DC ± 10% 2A 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE -25...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 95 mm / 87 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 95 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 95 mm / 87 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 95 mm / 87 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type RS 16IO 2W I H S Height 72 mm Order No. 1311810000 Type Height Order No. 72 mm 72 mm 1311820000 RS 16IO 2W I-L H S RS 16IO 2W I H Z 9445750000 RS 16IO 2W I-L H Z 72 mm 1311830000 Ordering data Screw connection without LED Screw connection with LED Tension-clamp connection without LED Tension-clamp connection with LED Note Accessories Note A.46 1327330000 – 2012/2013 RS IO - Interface for 16 digital signals 2-wire H system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 16IO 2W F H RS 16IO 2W F-L H H system, 2 wires with fuse per channel H system, 2 wires with LED and fuse per channel Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug No yellow 500 mA 3.15 A No Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug green yellow 500 mA 3.15 A No 25 V AC / 50 V DC 1A 24 V DC ± 10% 2A 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C -25...+50°C -40...+60 °C CE < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 122 mm / 87 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 122 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 122 mm / 87 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 122 mm / 87 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type RS 16IO 2W F H S Height 72 mm Order No. 9445820000 Type Height Order No. 72 mm 72 mm 1311840000 RS 16IO 2W F-L H S RS 16IO 2W F H Z 1311850000 RS 16IO 2W F-L H Z 72 mm 1311870000 Ordering data Screw connection without LED Screw connection with LED Tension-clamp connection without LED Tension-clamp connection with LED Note Accessories Note 1327330000 – 2012/2013 A.47 Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS IO - Interface for 16 digital signals 3-wire H system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 16IO 3W H RS 16IO 3W L H H system, 3 wires H system, 3 wires with LED A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug No yellow No 3.15 A No Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug green yellow No 3.15 A No 25 V AC / 50 V DC 1A 24 V DC ± 10% 2A 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE; GOSTME25 -25...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 90 mm / 87 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 90 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 90 mm / 87 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 90 mm / 87 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type RS 16IO 3W H S Height 72 mm Order No. 9445760000 Type Height Order No. 72 mm 72 mm 1311880000 RS 16IO 3W L H S RS 16IO 3W H Z 9445770000 RS 16IO 3W L H Z 72 mm 1311890000 Ordering data Screw connection without LED Screw connection with LED Tension-clamp connection without LED Tension-clamp connection with LED Note Accessories Note A.48 1327330000 – 2012/2013 RS IO - Interface for 16 digital signals 1-wire R system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 16IO 1W R RS 16IO 1W I R R system, 1 wire R system, 1 wire with disconnection per channel Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Connector RSV 1.6 24-pole female No No No No No Connector RSV 1.6 24-pole female No No No 3.15 A No 150 V UC 1A 24 V DC ± 10% 3A 250 V UC 1A 24 V DC ± 10% 3A -25...+50°C -40...+60 °C CE; GOSTME25 -25...+50°C -40...+60 °C CE; GOSTME25 < 150 V AC II 2 1.5 kV < 250 V AC II 2 2.1 kV Screw connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 97 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 127 mm / 87 mm Ordering data Screw connection without LED Type RS 16IO 1W R S Height 68 mm Order No. 9441500000 Type RS 16IO 1W I R S Height 72 mm Order No. 9441860000 Note Accessories Note 1327330000 – 2012/2013 A.49 Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS IO - Interface for 16 digital signals 2-wire R system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 16IO 2W R RS 16IO 2W F R R system, 2 wires R system, 2 wires with fuse per channel A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Rated voltage (text) Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Connector RSV 1.6 24-pole female No No No 3.15 A No Connector RSV 1.6 24-pole female No No 1A 3.15 A No 150 V UC 1A 24 V DC ± 10% 3A 150 V UC 1A 24 V DC ± 10% 3A -25...+50°C -40...+60 °C CE; GOSTME25 -25...+50°C -40...+60 °C CE; GOSTME25 < 150 V AC II 2 1.5 kV < 150 V AC II 2 1.5 kV Screw connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 123 mm / 87 mm Screw connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 123 mm / 109 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type RS 16IO 2W R S Type RS 16IO 2W F R S Ordering data Screw connection without LED Height 72 mm Order No. 9441700000 Height 72 mm Order No. 9441560000 Note Accessories Note A.50 1327330000 – 2012/2013 RS IO - Interface for 16 digital signals 3-wire R system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS 16IO 3W I R R system, 3 wires with disconnection per channel A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Connector RSV 1.6 24-pole female No No No 3.15 A No 250 V UC 1A 24 V DC ± 10% 3A -25...+50°C -40...+60 °C CE; GOSTME25 250 V AC II 2 2.1 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 116 mm / 109 mm Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note The common C may carry up to 3 A if the external jumpers are not used Ordering data Screw connection without LED Type RS 16IO 3W I R S Height 84 mm Order No. 9441600000 Note Accessories Note 1327330000 – 2012/2013 A.51 Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS IO - Interface for 32 digital signals 1-wire H system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 32IO 1W H RS 32IO 1W L H H system, 1 wire H system, 1 wire with LED A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note 2x Plug-in connector acc. IEC 603-1 / DIN 41651 2x20-pole plug No yellow No 3.15 A No 2x Plug-in connector acc. IEC 603-1 / DIN 41651 2x20-pole plug green yellow No 3.15 A No 25 V AC / 50 V DC 1A 24 V DC ± 10% 2A 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE -25...+50°C -40...+60 °C CE < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 90 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 90 mm / 87 mm Ordering data Screw connection without LED Screw connection with LED Type RS 32IO 1W H S Height 72 mm Order No. 9445900000 Type Height Order No. RS 32IO 1W L H S 72 mm 9445910000 Note Accessories Note A.52 1327330000 – 2012/2013 RS 32IO 1W I-L H H system, 1 wire with LED and disconnection per channel Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals A 2x Plug-in connector acc. IEC 603-1 / DIN 41651 2x20-pole plug green yellow No 3.15 A No 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 220 mm / 87 mm Type Height Order No. RS 32IO 1W I-L H S 72 mm 9445870000 1327330000 – 2012/2013 A.53 Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS IO - Interface for 32 digital signals 2-wire H system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 32IO 2W L H RS 32IO 2W I-L H H system, 2 wires with LED H system, 2 wires with LED and disconnection per channel A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note 2x Plug-in connector acc. IEC 603-1 / DIN 41651 2x20-pole plug green yellow No 3.15 A No 2x Plug-in connector acc. IEC 603-1 / DIN 41651 2x20-pole plug green yellow No 3.15 A No 24 V DC ± 10% 1A 24 V DC ± 10% 2A 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE -25...+50°C -40...+60 °C CE < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 170 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 170 mm / 87 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type Height Order No. Type Height Order No. RS 32IO 2W L H S 72 mm 9445930000 RS 32IO 2W I-L H S 72 mm 9445950000 Ordering data Screw connection without LED Screw connection with LED Note Accessories Note A.54 1327330000 – 2012/2013 Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS 32IO 2W F H H system, 2 wires with fuse per channel A 2x Plug-in connector acc. IEC 603-1 / DIN 41651 2x20-pole plug No yellow 500 mA 3.15 A No 25 V AC / 50 V DC 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 248 mm / 87 mm The common C may carry up to 3 A if the external jumpers are not used Type RS 32IO 2W F H S 1327330000 – 2012/2013 Height 72 mm Order No. 9445980000 A.55 Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS IO - Interface for 32 digital signals 3-wire H system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 32IO 3W H RS 32IO 3W L H H system, 3 wires H system, 3 wires with LED A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note 2x Plug-in connector acc. IEC 603-1 / DIN 41651 2x20-pole plug No yellow No 3.15 A No 2x Plug-in connector acc. IEC 603-1 / DIN 41651 2x20-pole plug green yellow No 3.15 A No 25 V AC / 50 V DC 1A 24 V DC ± 10% 2A 24 V DC ± 10% 1A 24 V DC ± 10% 2A -25...+50°C -40...+60 °C CE -25...+50°C -40...+60 °C CE < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 176 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 176 mm / 87 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type RS 32IO 3W H S Type Height Order No. RS 32IO 3W L H S 72 mm 9445970000 Ordering data Screw connection without LED Screw connection with LED Height 72 mm Order No. 9445960000 Note Accessories Note A.56 1327330000 – 2012/2013 RS IO - Interface for 32 digital signals 1-wire R system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 32IO 1W R RS 32IO 1W I R R system, 1 wire R system, 1 wire with disconnection per channel Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Connector RSV 1.6 36-pole female No No No No No Connector RSV 1.6 36-pole female No No No 3.15 A No 150 V UC 1A 24 V DC ± 10% 3A 250 V UC 1A 24 V DC ± 10% 3A -25...+50°C -40...+60 °C CE -25...+50°C -40...+60 °C CE < 150 V AC II 2 1.5 kV < 250 V AC II 2 2.1 kV Screw connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 148 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 188 mm / 87 mm Ordering data Screw connection without LED Type RS 32IO 1W R S Height 72 mm Order No. 9441510000 Type RS 32IO 1W I R S Height 72 mm Order No. 9441870000 Note Accessories Note 1327330000 – 2012/2013 A.57 Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS IO - Interface for 32 digital signals 2-wire R system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection RS 32IO 2W R RS 32IO 2W F R R system, 2 wires R system, 2 wires with fuse per channel A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Connector RSV 1.6 36-pole female No No No 3.15 A No Connector RSV 1.6 36-pole female No No 2A 3.15 A No 150 V UC 1A 24 V DC ± 10% 3A 150 V UC 1A 24 V DC ± 10% 3A -25...+50°C -40...+60 °C CE -25...+50°C -40...+60 °C CE < 150 V AC II 2 1.5 kV < 150 V AC II 2 1.5 kV Screw connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 200 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 200 mm / 109 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type RS 32IO 2W R S Type RS 32IO 2W F R S Ordering data Screw connection without LED Height 72 mm Order No. 9441710000 Height 84 mm Order No. 9441570000 Note Accessories Note A.58 1327330000 – 2012/2013 RS IO - Interface for 32 digital signals 3-wire R system Digital input/output passive interface • 1 , 2 or 3 wires •W ith LED indicator (optional) •W ith fuse or disconnection per channel (optional) • F use powered protection • S crew or tension clamp connection Universal solutions for PLC input/ output cards RS IO - Passive interface for digital signals RS 32IO 3W I R R system, 3 wires with disconnection per channel A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Fuse per channel Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Connector RSV 1.6 36-pole female No No No 3.15 A No 150 V UC 1A 24 V DC ± 10% 3A -25...+50°C -40...+60 °C CE < 150 V AC II 2 1.5 kV Screw connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 188 mm / 109 mm Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note The common C may carry up to 3 A if the external jumpers are not used Ordering data Screw connection without LED Type RS 32IO 3W I R S Height 84 mm Order No. 9441610000 Note Accessories Note 1327330000 – 2012/2013 A.59 Universal solutions for PLC input/ output cards Selection guide A RS A – Selection guide for passive interfaces for analogue signals Type of Interface Number of Family channels Connection Screw Tension clamp connection Features Common distribution V 4-channels A1504 Z V Z 4-channels M A1504M A2508 Z V Z 8-channel P A2508P V 8-channel M A2508M V 16-channel A3716 V Z V Z Note: T T M M M M I I M I M M M M I I T T T T Interfaces Order No. Type Page 9448000000 1308230000 9448100000 1308240000 1289090000 RS 4AIO DP SD S RS 4AIO DP SD Z RS 4AIO I-M-DP SD S RS 4AIO I-M-DP SD Z RS 4AIO DP-M258 SD S A.61 A.61 A.61 A.61 A.62 9448010000 1308250000 9448110000 9449110000 RS 8AIO DP SD S RS 8AIO DP SD Z RS 8AIO I-M-DP SD S RS 8AIO I-M-DP SD Z A.63 A.63 A.63 A.63 9448030000 RS 8AI PREM/APR SD S A.64 9448040000 RS 8AI1AO MICRO SD S A.64 9448020000 1308270000 9448120000 1308280000 RS 16AIO DP SD S RS 16AIO DP SD Z RS 16AIO I-M-DP SD S RS 16AIO I-M-DP SD Z A.65 A.65 A.65 A.65 Coding of the interface descriptions RS 4AIO: 4 inputs/outputs DP: Power distribution 8AIO: 8 inputs/outputs (empty) 8AI: 8 inputs 8AI1AO: 8 inputs/1 outputs 16AIO: 16 inputs/outputs A.60 I I Test points V V 8-channel M M M M Disconnectable I-M: Switch + Test point SD connector SUB-D M258: For Schneider M258 PREM/APR: For Schneider Premium MICRO: For Schneider Micro (empty) S: Screw Z: Tension clamp connection 1327330000 – 2012/2013 RS A - Passive interface for 4 analogue signals Analogue input/output passive interface: •W ith test points or disconnection per channel (optional) • S crew or tension clamp connection RS 4AIO DP SD RS 4AIO I-M-DP SD 4 channels 4 channels, test points and disconnection per channel Universal solutions for PLC input/ output cards RS A - Passive interface for analogue signals A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) SUB-D plug, in compliance with IEC 807-2 / DIN 41652 15-pole plug No No 3.15 A No SUB-D plug, in compliance with IEC 807-2 / DIN 41652 15-pole plug No No 3.15 A Diameter: 4 mm ≤ 25 V AC / 50 V DC 0.5 A 24 V DC ± 10% 3A ≤ 25 V AC / 50 V DC 0.5 A 24 V DC ± 10% 3A -20...+50°C -40...+60 °C CE -20...+50°C -40...+60 °C CE < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 75 mm / 87 mm Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 75 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 73 mm / 109 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 73 mm / 109 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type RS 4AIO DP SD S RS 4AIO DP SD Z Type RS 4AIO I-M-DP SD S RS 4AIO I-M-DP SD Z Ordering data Screw connection Tension clamp connection Height 72 mm 72 mm Order No. 9448000000 1308230000 Height 81 mm 81 mm Order No. 9448100000 1308240000 Note Accessories Note 1327330000 – 2012/2013 A.61 Universal solutions for PLC input/ output cards RS A - Passive interface for analogue signals RSA - Interface for 4 analogue signals for Schneider M258 Analogue input/output passive interface: •W ith test points or disconnection per channel (optional) • S crew or tension clamp connection RS 4AIO DP-M258 SD 4 channels for M258 (Schneider), config. by voltage or current A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) SUB-D plug, in compliance with IEC 807-2 / DIN 41652 15-pole plug No No No No ≤ 25 V AC / 50 V DC 0.5 A 24 V DC ± 10% 3A -20...+50°C -40...+60 °C CE < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 45 mm / 70 mm Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Ordering data Screw connection Type RS 4AIO DP-M258 SD S Height 60 mm Order No. 1289090000 Note Accessories Note A.62 1327330000 – 2012/2013 RSA - Interface for 8 analogue signals Analogue input/output passive interface: •W ith test points or disconnection per channel (optional) • S crew or tension clamp connection RS 8AIO DP SD RS 8AIO I-M-DP SD 8 channels 8 channels, test points and disconnection per channel Universal solutions for PLC input/ output cards RS A - Passive interface for analogue signals A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) SUB-D plug, in compliance with IEC 807-2 / DIN 41652 25-pole plug No No 3.15 A No SUB-D plug, in compliance with IEC 807-2 / DIN 41652 25-pole plug No No 3.15 A Diameter: 4 mm ≤ 25 V AC / 50 V DC 0.5 A 24 V DC ± 10% 3A ≤ 25 V AC / 50 V DC 0.5 A 24 V DC ± 10% 3A -20...+50°C -40...+60 °C CE; GOSTME25 -20...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 117 mm / 87 mm Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 117 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 114 mm / 109 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 114 mm / 109 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type RS 8AIO DP SD S RS 8AIO DP SD Z Type RS 8AIO I-M-DP SD S RS 8AIO I-M-DP SD Z Ordering data Screw connection Tension clamp connection Height 72 mm 72 mm Order No. 9448010000 1308250000 Height 81 mm 81 mm Order No. 9448110000 9449110000 Note Accessories Note 1327330000 – 2012/2013 A.63 Universal solutions for PLC input/ output cards RS A - Passive interface for analogue signals RSA - Interface for 8 and 9 analogue signals for Schneider Micro/Premium RS 8AI PREM/APR SD RS 8AI1AO MICRO SD 8 channels for Premium (Schneider) config. by volt. or current 9 channels for Micro (Schneider) Analogue input/output passive interface: •W ith test points or disconnection per channel (optional) • S crew or tension clamp connection A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note SUB-D plug, in compliance with IEC 807-2 / DIN 41652 25-pole plug No No No No SUB-D plug, in compliance with IEC 807-2 / DIN 41652 15-pole plug No No No No ≤ 25 V AC / 50 V DC 0.5 A 24 V DC ± 10% 3A ≤ 25 V AC / 50 V DC 0.5 A 24 V DC ± 10% 3A -20...+50°C -40...+60 °C CE; GOSTME25 -20...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 116 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 100 mm / 87 mm The common C may carry up to 3 A if the external jumpers are not used Ordering data Screw connection Type RS 8AI PREM/APR SD S Height 72 mm Order No. 9448030000 Type RS 8AI1AO MICRO SD S Height 72 mm Order No. 9448040000 Note Accessories Note A.64 1327330000 – 2012/2013 RSA - Interface for 16 analogue signals Analogue input/output passive interface: •W ith test points or disconnection per channel (optional) • S crew or tension clamp connection RS 16AIO DP SD RS 16AIO I-M-DP SD 16 channels 16 channels, test points and disconnection per channel Universal solutions for PLC input/ output cards RS A - Passive interface for analogue signals A Technical data Connection data and functionality Connection on control side Number of poles (control side) LED status display per channel LED status of the supply voltage Power supply fuse Type of test point Rated data Operating voltage Max. current per channel Operating voltage (supply) Operating current (supply) General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated insulation voltage Surge voltage category Pollution severity level Pulse voltage test (1,2/50μs) SUB-D plug, in compliance with IEC 807-2 / DIN 41652 37-pole plug No No 3.15 A No SUB-D plug, in compliance with IEC 807-2 / DIN 41652 37-pole plug No No 3.15 A Diameter: 4 mm ≤ 25 V AC / 50 V DC 0.5 A 24 V DC ± 10% 3A ≤ 25 V AC / 50 V DC 0.5 A 24 V DC ± 10% 3A -20...+50°C -40...+60 °C CE; GOSTME25 -20...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC III 2 0.8 kV < 50 V AC III 2 0.8 kV Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 205 mm / 87 mm Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 205 mm / 87 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 197 mm / 109 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 197 mm / 109 mm The common C may carry up to 3 A if the external jumpers are not used The common C may carry up to 3 A if the external jumpers are not used Type RS 16AIO DP SD S RS 16AIO DP SD Z Type RS 16AIO I-M-DP SD S RS 16AIO I-M-DP SD Z Ordering data Screw connection Tension clamp connection Height 81 mm 72 mm Order No. 9448020000 1308270000 Height 81 mm 81 mm Order No. 9448120000 1308280000 Note Accessories Note 1327330000 – 2012/2013 A.65 Universal solutions for PLC input/ output cards Selection guide A RSM – Selection guide for insulated interfaces for digital input signals Type of Interface Number of Family channels 16-channel I2016 Design C C C C Screw Features Connection Tension clamp connection V Z V Z Interfaces Voltage Order No. Type 24 V DC 24 V DC 48 V DC 48 V DC 1312000000 1312010000 1312020000 1312030000 RSM-16DI 24VDC S RSM-16DI 24VDC Z RSM-16DI 48VDC S RSM-16DI 48VDC Z Page A.67 A.67 A.68 A.68 Note A.66 1327330000 – 2012/2013 RSM - isolated interfaces for 16 digital input signals Relay digital input interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system: • E lectrical insulation using pluggable relays (interchangeable with solid-state relays; MICROSERIES family) Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital input signals RSM-16 DI 24 V DC 6 mm relays; 24 V DC AU A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. DC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category input/input Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RSS green yellow 2A 24 V DC ± 10% 13 mA 24 V DC ± 10% 2A AgNi, gold flashed 24 V DC ± 10% 0.1 A 1 mA 1V 5 x 106 switching cycles -20...+50°C -20...+70 °C CE ≤ 50 V DC ≤ 50 V DC III III 2 1.5 kV 0.35 kVAC ≥ 6 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 124 mm / 109 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 124 mm / 109 mm Ordering data Screw connection without switch Tension-clamp connection without switch Type RSM-16DI 24VDC S RSM-16DI 24VDC Z Height 72 mm 72 mm Order No. 1312000000 1312010000 Note Accessories Note 1327330000 – 2012/2013 Relay 4061590000 RSS 24 V DC 1CO AU A.67 Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital input signals RSM - isolated interfaces for 16 digital input signals Relay digital input interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system: • E lectrical insulation using pluggable relays (interchangeable with solid-state relays; MICROSERIES family) RSM-16 DI 48 V DC 6 mm relays; 48 V DC AU A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. DC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category input/input Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RSS green yellow 2A 48 V DC ± 10% 10 mA 24 V DC ± 10% 2A AgNi, gold flashed 24 V DC ± 10% 0.1 A 2 mA 5V 10 x 106 switching cycles -20...+50°C -20...+70 °C CE ≤ 50 V DC ≤ 50 V DC III III 2 1.5 kV 0.35 kVAC ≥ 6 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 124 mm / 109 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 124 mm / 109 mm Ordering data Screw connection without switch Tension-clamp connection without switch Type RSM-16DI 48VDC S RSM-16DI 48VDC Z Height 72 mm 72 mm Order No. 1312020000 1312030000 Note Accessories Note A.68 1327330000 – 2012/2013 A 1327330000 – 2012/2013 A.69 Universal solutions for PLC input/ output cards Universal solutions for PLC input/ output cards Selection guide A RSM – Selection guide for insulated interfaces for digital output signals Type of Interface Number of Family channels 8-channel O2008 12-channel O2012 16-channel Note 1: O2016 Design: Note 2: A.70 Design Connection Screw Tension clamp connection Features Voltage Type of contact 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 1CO 1CO 1CO 1CO 1CO 1CO V V 24 V DC 24 V DC 1CO 1CO C C C C V V 1 line 1 line 1 line 1 line 2 lines 2 lines 1 line 1 line 1 line 1 line 1 line 1 line 1 line V V 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC (+/-) 24 V DC (+/-) 24 V DC (+/-) 24 V DC (+/-) 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 24 V DC 1CO 1CO 1CO 1CO 1CO 1CO 1CO 1CO 1CO 1CO 1CO 1CO 2CO 2CO 1CO 1CO 1CO C C C C V V 2 lines 2 lines V C Z Z Z 2 lines Z Z Z Z V Z V Z V Z V Z V C Relays with 6 mm relay Fuse Switch (coil) Switch (contact) P P P P P P F F P Interfaces Order No. Type 1128970000 1128990000 1128980000 1129000000 9445000000 9447000000 RSM-8 PLC C 1CO S RSM-8 PLC C SW 1CO S RSM-8 PLC C 1CO Z RSM-8 PLC C SW 1CO Z RSM-8 C 1CO S RSM-8 C 1CO Z A.71 A.71 A.71 A.71 A.72 A.72 1289100000 9445060000 RSM-12 PLC C 1CO S RSM-12 C 1CO S A.73 A.74 1129010000 1129030000 1129020000 1129040000 1129100000 1129120000 1129110000 1129130000 9445100000 9447100000 9444610000 9444660000 9445160000 9447160000 9445120000 9447120000 9445140000 RSM-16 PLC C 1CO S RSM-16 PLC C SW 1CO S RSM-16 PLC C 1CO Z RSM-16 PLC C SW 1CO Z RSM-16 PLC 1CO S RSM-16 PLC SW 1CO S RSM-16 PLC 1CO Z RSM-16 PLC SW 1CO Z RSM-16 C 1CO S RSM-16 C 1CO Z RSM-16 24V(-/+) 1CO S RSM-16 24V(-/+) 1CO Z RSM-16 2CO S RSM-16 2CO Z RSM-16 FUS 1CO S RSM-16 FUS 1CO Z RSM-16 FOR 1CO S A.75 A.75 A.75 A.75 A.76 A.76 A.76 A.76 A.77 A.77 A.78 A.78 A.79 A.79 A.80 A.80 A.81 1 line 2 lines RCL Relays arranged in 1 single line RCL relays (arranged in 2 rows) Page Voltage: Modules indicated with 24 V DC (+/-) can function as positive or negative and can function with negative logic PLC cards 1327330000 – 2012/2013 RSM - Interfaces for 8 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals RSM-8 PLC C 1CO 6 mm relay with 1 CO contact and switch A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RSS green yellow No 2.5 A 24 V DC ± 10% 13 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 2.5 A 0.1 A 5V 5 x 106 switching cycles -25...+50°C -40...+60 °C CE < 50 V AC 250 V AC III II 2 6 kV 1.2 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 75 mm / 109 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 75 mm / 109 mm Ordering data Screw connection without switch Screw connection with switch Tension-clamp connection without switch Tension-clamp connection with switch Type RSM-8 PLC C 1CO S RSM-8 PLC C SW 1CO S RSM-8 PLC C 1CO Z RSM-8 PLC C SW 1CO Z Note Height 85 mm 85 mm 80 mm 80 mm Order No. 1128970000 1128990000 1128980000 1129000000 Accessories Note 1327330000 – 2012/2013 Relay 4060120000 RSS 24 V DC 1CO A.71 Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals RSM - Interfaces for 8 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) RSM-8 C 1C RCL relays (arranged in 2 rows) with 1 CO contact A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RCL green yellow No 3.15 A 24 V DC ± 10% 20 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 5A 0.01 A 12 V 3 x 107 switching cycles -25...+50°C -40...+60 °C CE; GOSTME25 < 50 V AC < 250 V AC III II 2 6 kV 1.2 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 35, TS 32 110 mm / 109 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 35, TS 32 110 mm / 109 mm Ordering data Screw connection without switch Screw connection with switch Tension-clamp connection without switch Tension-clamp connection with switch Type RSM-8 C 1CO S Height 68 mm Order No. 9445000000 RSM-8 C 1CO Z 68 mm 9447000000 Note Accessories Note A.72 Relay 8693260000 RCL314024 24 V DC 1CO 1327330000 – 2012/2013 RSM - Interfaces for 12 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals RSM-12 PLC 1C 6 mm relay with 1 CO contact A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RSS green yellow No 2.5 A 24 V DC ± 10% 13 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 2.5 A 0.1 A 5V 5 x 106 switching cycles -25...+50°C -40...+60 °C < 50 V AC 250 V AC III II 2 6 kV 1.2 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 95 mm / 109 mm Ordering data Screw connection without switch Type RSM-12 PLC C 1CO S Height 85 mm Order No. 1289100000 Note Accessories Note 1327330000 – 2012/2013 Relay 4060120000 RSS 24 V DC 1CO A.73 Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals RSM - Interfaces for 12 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) RSM-12 C 1CO S RCL relays (arranged in 2 rows) with 1 CO contact A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RCL green yellow No 3.15 A 24 V DC ± 10% 20 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 5A 0.01 A 12 V 3 x 107 switching cycles -25...+40°C -40...+60 °C CE; GOSTME25 < 50 V AC < 250 V AC III II 2 6 kV 1.2 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 35, TS 32 147 mm / 109 mm Ordering data Screw connection without switch Type RSM-12 C 1CO S Height 68 mm Order No. 9445060000 Note Accessories Note A.74 Relay 8693260000 RCL314024 24 V DC 1CO 1327330000 – 2012/2013 RSM - Interfaces for 16 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals RSM-16 PLC C 1CO 6 mm relay with 1 CO contact and switch A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RSS green yellow No 2.5 A 24 V DC ± 10% 13 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 2.5 A 0.1 A 5V 5 x 106 switching cycles -25...+50°C -40...+60 °C CE < 50 V AC 250 V AC III II 2 6 kV 1.2 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 111 mm / 109 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 111 mm / 109 mm Ordering data Screw connection without switch Screw connection with switch Tension-clamp connection without switch Tension-clamp connection with switch Type RSM-16 PLC C 1CO S RSM-16 PLC C SW 1CO S RSM-16 PLC C 1CO Z RSM-16 PLC C SW 1CO Z Note Height 85 mm 85 mm 80 mm 80 mm Order No. 1129010000 1129030000 1129020000 1129040000 Accessories Note 1327330000 – 2012/2013 Relay 4060120000 RSS 24 V DC 1CO A.75 Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals RSM - Interfaces for 16 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) RSM-16 PLC 1CO 6 mm relay with 1 CO contact and switch A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RCL green yellow No 2.5 A 24 V DC ± 10% 22 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 6A 0.01 A 12 V 3 x 107 switching cycles -25...+50°C -40...+60 °C CE < 50 V AC 250 V AC III II 2 6 kV 1.2 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 32, TS 35 255 mm / 109 mm Tension clamp connection 0.13 mm² / 2.5 mm² 0.13 mm² / 2.5 mm² TS 32, TS 35 255 mm / 109 mm Ordering data Screw connection without switch Screw connection with switch Tension-clamp connection without switch Tension-clamp connection with switch Type RSM-16 PLC 1CO S RSM-16 PLC SW 1CO S RSM-16 PLC 1CO Z RSM-16 PLC SW 1CO Z Note Height 68 mm 68 mm 68 mm 68 mm Order No. 1129100000 1129120000 1129110000 1129130000 Accessories Note A.76 Relay 8693260000 RCL314024 24 V DC 1CO 1327330000 – 2012/2013 RSM - Interfaces for 16 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) RSM-16 C 1CO RCL relays (arranged in 2 rows) with 1 CO contact Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RCL green yellow No 3.15 A 24 V DC ± 10% 20 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 5A 0.01 A 12 V 3 x 107 switching cycles -25...+40°C -40...+60 °C CE; GOSTME25 < 50 V AC < 250 V AC III II 2 6 kV 1.2 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 35, TS 32 185 mm / 109 mm Tension clamp connection 0.15 mm² / 1.5 mm² 0.15 mm² / 1.5 mm² TS 35, TS 32 185 mm / 109 mm Ordering data Screw connection without switch Screw connection with switch Tension-clamp connection without switch Tension-clamp connection with switch Type RSM-16 C 1CO S Height 68 mm Order No. 9445100000 RSM-16 C 1CO Z 68 mm 9447100000 Note Accessories Note 1327330000 – 2012/2013 Relay 8693260000 RCL314024 24 V DC 1CO A.77 Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals RSM - Interfaces for 16 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) RSM-16 24 V(-/+) 1CO RCL relays, 24 V DC voltage with 1 CO contact A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RCL green yellow No No 24 V DC ± 10% 22 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 5A 0.01 A 12 V 3 x 107 switching cycles -25...+40°C -40...+60 °C CE; GOSTME25 < 50 V AC < 250 V AC III II 2 6 kV 2.5 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 35, TS 32 267 mm / 87.5 mm Tension clamp connection 0.15 mm² / 1.5 mm² 0.15 mm² / 1.5 mm² TS 35, TS 32 267 mm / 87.5 mm Ordering data Screw connection without switch Screw connection with switch Tension-clamp connection without switch Tension-clamp connection with switch Type RSM-16 24V(-/+) 1CO S Height 68 mm Order No. 9444610000 RSM-16 24V(-/+) 1CO Z 68 mm 9444660000 Note Accessories Note A.78 Relay 8693260000 RCL314024 24 V DC 1CO 1327330000 – 2012/2013 RSM - Interfaces for 16 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals RSM-16 2CO RCL relays with 2 CO contacts A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RCL green yellow No 3.15 A 24 V DC ± 10% 17 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 4A 0.01 A 12 V 3 x 107 switching cycles -25...+40°C -40...+60 °C CE; GOSTME25 < 50 V AC < 250 V AC III II 2 6 kV 2.5 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 35, TS 32 263 mm / 109 mm Tension clamp connection 0.15 mm² / 1.5 mm² 0.15 mm² / 1.5 mm² TS 35, TS 32 263 mm / 109 mm Ordering data Screw connection without switch Screw connection with switch Tension-clamp connection without switch Tension-clamp connection with switch Type RSM-16 2CO S Height 68 mm Order No. 9445160000 RSM-16 2CO Z 68 mm 9447160000 Note Accessories Note 1327330000 – 2012/2013 Relay 4058570000 RCL424024 2CO A.79 Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals RSM - Interfaces for 16 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) RSM-16 FUS 1CO RCL relays, 1 CO contact with fuse relay contact A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RCL green yellow 5A 3.15 A 24 V DC ± 10% 20 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 5A 0.01 A 12 V 3 x 107 switching cycles -25...+40°C -40...+60 °C CE; GOSTME25 < 50 V AC < 250 V AC III II 2 6 kV 1.2 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 35, TS 32 261 mm / 109 mm Tension clamp connection 0.15 mm² / 1.5 mm² 0.15 mm² / 1.5 mm² TS 35, TS 32 261 mm / 109 mm Ordering data Screw connection without switch Screw connection with switch Tension-clamp connection without switch Tension-clamp connection with switch Type RSM-16 FUS 1CO S Height 75 mm Order No. 9445120000 RSM-16 FUS 1CO Z 75 mm 9447120000 Note Accessories Note A.80 Relay 8693260000 RCL314024 24 V DC 1CO 1327330000 – 2012/2013 RSM - Interfaces for 16 isolated digital output signals Relay digital output interface for transmitting electrical signals between the PLC and the field via pre-wired cables of Weidmüller’s universal system. • Input/output reinforced insulation (basic between contacts) Universal solutions for PLC input/ output cards RSM - isolated interfaces for digital output signals RSM-16 FOR 1CO RCL relays, 1 CO contact and switch A Technical data Connection data and functionality Connection on control side Number of poles (control side) Relay type LED status display per relay LED status of the supply voltage Fuse per relay Power supply fuse Nominal input data Input voltage Input current Operating voltage (supply) Operating current (supply) Nominal output data Contact material Operating voltage Max. AC continuous current Minimum contact current Minimum contact voltage Mechanical service life General data Ambient temperature (operational) Storage temperature Approvals Insulation coordination (EN50178) Rated input insulation voltage Rated output insulation voltage Overvoltage category input/output Overvoltage category output/output Pollution severity level Pulse voltage test (1,2/50μs) Insulation test voltage Clearance input/output Dimensions Clamping range, min. /max. [Field] Clamping range, min. /max. [supply] Mounting rail Length x width Note Plug-in connector acc. IEC 603-1 / DIN 41651 20-pole plug RCL green yellow No 3.15 A 24 V DC ± 10% 17 mA 24 V DC ± 10% 2A AgNi 90/10 250 V AC 2A 0.01 A 12 V 3 x 107 switching cycles -25...+40°C -40...+60 °C CE; GOSTME25 < 50 V AC < 250 V AC III II 2 6 kV 1.2 kVAC ≥ 5.5 mm Screw connection 0.13 mm² / 6 mm² 0.13 mm² / 6 mm² TS 35, TS 32 263 mm / 109 mm Ordering data Screw connection without switch Screw connection with switch Tension-clamp connection without switch Tension-clamp connection with switch Type RSM-16 FOR 1CO S Height 75 mm Order No. 9445140000 Note Accessories Note 1327330000 – 2012/2013 Relay 8693260000 RCL314024 24 V DC 1CO A.81 Universal solutions for PLC input/ output cards Selection guide A PAC-UNIV Universal pre-asembled cables You can choose the ideal pre-assembled cable for your PLC card from the following tables. Calculate voltage and current values allowed by the cable as dictated by the application. More technical information can be found in our on-line catalogue at www.weidmueller.com Input/Output cards Siemens S7-300 6ES7312-5BD00-0AB0 6ES7312-5BD01-0AB0 6ES7312-5BE03-0AB0 6ES7313-5BE00-0AB0 6ES7313-5BE01-0AB0 6ES7313-5BF03-0AB0 6ES7313-6BE00-0AB0 6ES7313-6BE01-0AB0 6ES7313-6BF03-0AB0 6ES7313-6CE00-0AB0 6ES7313-6CE01-0AB0 6ES7313-6CF03-0AB0 6ES7314-6BF00-0AB0 6ES7314-6BF01-0AB0 6ES7314-6BF02-0AB0 6ES7314-6CF00-0AB0 6ES7314-6CF01-0AB0 6ES7314-6CF02-0AB0 6ES7321-1BH00-0AA0 6ES7321-1BH01-0AA0 6ES7321-1BH02-0AA0 6ES7321-1BH50-0AA0 6ES7321-1BH80-0AA0 6ES7321-1BH81-0AA0 6ES7321-1BH82-0AA0 6ES7321-1BL00-0AA0 6ES7321-1BL80-0AA0 6ES7321-1BP00-0AA0 6ES7321-1CH20-0AA0 6ES7321-1CH80-0AA0 6ES7321-1EH00-0AA0 6ES7321-1EH01-0AA0 6ES7321-1EL00-0AA0 6ES7321-1FF00-0AA0 6ES7321-1FF01-0AA0 6ES7321-1FF81-0AA0 6ES7321-1FH00-0AA0 6ES7321-7BH00-0AB0 6ES7321-7BH01-0AB0 6ES7321-7BH80-0AB0 6ES7321-7RD00-0AB0 6ES7322-1BF00-0AA0 6ES7322-1BF01-0AA0 6ES7322-1BH00-0AA0 6ES7322-1BH01-0AA0 6ES7322-1BH10-0AA0 6ES7322-1BH81-0AA0 6ES7322-1BL00-0A00 6ES7322-1BP00-0AA0 6ES7322-1BP50-0AA0 6ES7322-1CF00-0AA0 6ES7322-1CF80-0AA0 6ES7322-1EH00-0AA0 6ES7322-1EH01-0AA0 6ES7322-1EL00-0AA0 6ES7322-1FF00-0AA0 6ES7322-1FF01-0AA0 6ES7322-1FF81-0AA0 6ES7322-1FH00-0AA0 6ES7322-1FL00-0AA0 A.82 Cables 7789606xxx 7789606xxx 7789606xxx 7789608xxx + 7789609xxx 7789608xxx + 7789609xxx 7789608xxx + 7789609xxx 7789608xxx 7789608xxx 7789608xxx 7789608xxx 7789608xxx 7789608xxx 7789608xxx + 7789609xxx 7789608xxx + 7789609xxx 7789608xxx + 7789609xxx 7789608xxx + 7789609xxx 7789608xxx + 7789609xxx 7789608xxx + 7789609xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789608xxx 7789608xxx 7789790xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789608xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789608xxx 7789790xxx 7789790xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx Unit/ card 1 1 1 1+1 1+1 1+1 1 1 1 1 1 1 1+1 1+1 1+1 1+1 1+1 1+1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 2 1 1 1 1 2 Input/Output cards Siemens S7-300 6ES7322-1HF10-0AA0 6ES7322-1HF80-0AA0 6ES7322-5RD00-0AB0 6ES7322-5SD00-0AB0 6ES7322-8BF00-0AB0 6ES7322-8BH01-0AB0 6ES7323-1BH00-0A00 6ES7323-1BH01-00A0 6ES7323-1BH80-0A00 6ES7323-1BH80-0AA0 6ES7323-1BL00-0AA0 6ES7331-1KF01-0AB0 6ES7331-1KF02-0AB0 6ES7331-7KB00-0AB0 6ES7331-7KB01-0AB0 6ES7331-7KB02-0AB0 6ES7331-7KF00-0AB0 6ES7331-7KF01-0AB0 6ES7331-7KF02-0AB0 6ES7331-7NF00-0AB0 6ES7331-7PF00-0AB0 6ES7331-7PF01-0AB0 6ES7331-7RD00-0AB0 6ES7331-7TF01-0AB0 6ES7332-5HB00-0AB0 6ES7332-5HB01-0AB0 6ES7332-5HB81-0AB0 6ES7332-5HD00-0AB0 6ES7332-5HD01-0AB0 6ES7332-5HF00-0AB0 6ES7332-5RD00-0AB0 6ES7332-7ND01-0AB0 6ES7332-7ND02-0AB0 6ES7334-0CE01-0AA0 6ES7334-0KE00-0AB0 6ES7335-7HG01-0AB0 6ES7335-7HG02-0AB0 Input/Output cards Rockwell Control-Logix 1756-IA16 1756-IA16I 1756-IA8D 1756-IB16 1756-IB16D 1756-IB16I 1756-IB32 1756-IC16 1756-IF16 1756-IF6I 1756-IF8 1756-IH16I 1756-IM16I 1756-IN16 1756-IR6I 1756-OA16 1756-OA16I 1756-OA8 1756-OA8D 1756-OA8E 1756-OB16D 1756-OB16E 1756-OB16I 1756-OB32 1756-OB8 1756-OB8EI 1756-OC8 1756-OF4 Cables 7789608xxx 7789608xxx 7789606xxx 7789606xxx 7789606xxx 7789608xxx 7789606xxx 7789606xxx 7789606xxx 7789606xxx 7789608xxx 7789609xxx 7789609xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx 7789609xxx 7789609xxx 7789609xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx 7789609xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx 7789607xxx Cables 7789731xxx 7789733xxx 7789731xxx 7789731xxx 7789733xxx 7789733xxx 7789733xxx 7789731xxx 7789734xxx 7789732xxx 7789734xxx 7789733xxx 7789733xxx 7789731xxx 7789732xxx 7789731xxx 7789733xxx 7789731xxx 7789731xxx 7789731xxx 7789733xxx 7789731xxx 7789733xxx 7789733xxx 7789731xxx 7789733xxx 7789731xxx 7789732xxx Unit/ card 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Unit/ card 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 PAC- UNIV Pre-assembled cables •At one end of the PLC connector •The other end has a wire-end ferrule •Shielded cable with 0.25 mm2 cross section for analogue cards and un-shielded for digital cards. Input/Output cards Rockwell Control-Logix 1756-OF6CI 1756-OF6VI 1756-OF8 1756-OH8I 1756-ON8 1756-OV16E 1756-OW16I 1756-OX8I Cables Input/Output cards Omron CJ1W ID231 ID232 ID261 ID262 OD231 OD232 OD233 OD261 OD262 OD263 Cables Input/Output cards Mitsubishi Melsec Q QH42P QX41 QX41-S1 QX41Y41P QX42 QX42-S1 QX71 QX72 QX82 QX82-S1 QY41P QY42P QY71 Cables 7789732xxx 7789732xxx 7789732xxx 7789733xxx 7789731xxx 7789731xxx 7789733xxx 7789733xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx 7789790xxx Unit/ card 1 1 1 1 1 1 1 1 Unit/ card 1 1 2 2 1 1 1 2 2 2 Unit/ card 2 1 1 2 2 2 1 2 2 2 1 2 1 Universal pre-assembled cable composition Cables PLC Connector 7789606xxx 7789607xxx 7789608xxx 7789609xxx 7789731xxx 7789732xxx 7789733xxx 7789734xxx 7789790xxx S7300 6ES7921-3AH0-1AA0 20P S7300 6ES7921-3AH0-1AA0 20P S7300 6ES7921-3AH20-1AA0 40P S7300 6ES7921-3AH20-1AA0 40P 1756-TBNH 20P 1756-TBNH 20P 1756-TBCH 36P 1756-TBCH 36P FCN 40P Cable type LIYY LiYCY LIYY LiYCY LIYY LiYCY LIYY LiYCY LIYY The last 3 digits of the cable code indicate its length in decimetres For example, if the code ends in 100, the cable would be 10 m long. 1327330000 – 2012/2013
© Copyright 2026 Paperzz