Universal solutions for PLC input/output cards A

Universal solutions for PLC input/
output cards
Contents
Universal solutions for PLC input/output cards
Universal solutions for PLC input/output cards
1327330000 – 2012/2013
Introduction
A
A.2
ABB S800
– Selection guide
A.12
Emerson DeltaV
– Selection guide
A.13
GeFanuc 90-30
– Selection guide
A.14
GeFanuc RX3i
– Selection guide
A.15
Honeywell C200
– Selection guide
A.16
Mitsubishi MELSEC Q
– Selection guide
A.17
Moeller XIOC
– Selection guide
A.18
Omron C200H
– Selection guide
A.19
Omron CJ1W
– Selection guide
A.20
Omron CQM1
– Selection guide
A.21
Rockwell Compact Logix
– Selection guide
A.22
Rockwell Control Logix
– Selection guide
A.23
Rockwell Micro Logix 1400
– Selection guide
A.24
Rockwell SLC 500
– Selection guide
A.25
Schneider M258
– Selection guide
A.26
Schneider M340
– Selection guide
A.27
Schneider MICRO
– Selection guide
A.28
Schneider PREMIUM
– Selection guide
A.29
Schneider QUANTUM
– Selection guide
A.30
Schneider TWIDO
– Selection guide
A.31
Siemens S7-200
– Selection guide
A.32
Siemens S7-300 / ET- 200M
– Selection guide
A.33
Siemens S7-400
– Selection guide
A.36
Siemens S7-1200
– Selection guide
A.37
RS IO – Selection guide for passive interfaces for digital signals
A.38
RS IO – Passive interface for digital signals
A.40
RS A – Selection guide for passive interfaces for analogue signals
A.60
RS A – Passive interface for analogue signals
A.61
RSM – Selection guide for insulated interfaces for digital input signals
A.66
RSM – Isolated interfaces for digital input signals
A.67
RSM – Selection guide for insulated interfaces for digital output signals
A.70
RSM – Isolated interfaces for digital output signals
A.71
PAC-UNIV universal pre-asembled cables with wire-end ferrules
A.82
A.1
Universal solutions for PLC input/
output cards
Introduction
Universal solutions for PLC input/output cards
Aimed at reducing costs, and to save space and time in the
construction of electrical cabinets, the universal cabling
system for PLCs is provided as an effective alternative
to end-to-end cabling design. Weidmüller offers a wide
range of pre-assembled cables and interfaces to major
PLC manufacturers:
A
• The interfaces are used as an interconnection element
between the control and the process, and are supplied
with tension clamp or screw connection. Those interfaces,
with a compact design, provide different functions such
as LEDs, fuses, disconnectors or relays.
• The pre-assembled cables are supplied with the
manufacturer’s own connector at one end and are
available in different lengths.
Universal system
The system is designed to be compatible with
all main commercial PLCs: ABB, Emerson,
Fanuc, Honeywell, Mitsubishi, Omron, Rockwell,
Schneider, Siemens, ...
Guaranteed connection
The original factory connector is on one end
of the PLC and standard connectors are on the
other end: ribbon cable with fixing housing
for digital signals and SUB-D connector for
analogue signals. Available in different lengths.
A.2
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Introduction
Simple system configuration
Selection tables are available in this catalogue
to assist you in choosing the right products
for your application. In addition, there is also
an automatic software selection guide on the
website.
Selection guide
PLC
Input/Output cards
Manufacturer code
6ES7321-1BH00-0AA0
6ES7321-1BH01-0AA0
6ES7321-1BH02-0AA0
6ES7321-1BH50-0AA0
6ES7321-1BH80-0AA0
6ES7321-1BH81-0AA0
6ES7321-1BH82-0AA0
6ES7321-1BL00-0AA0
6ES7321-1BL80-0AA0
6ES7321-1BP00-0AA0
DI
DO
6ES7321-1CH20-0AA0
6ES7321-1CH80-0AA0
6ES7321-1EH00-0AA0
6ES7321-1EH01-0AA0
6ES7321-1EL00-0AA0
6ES7321-1FF00-0AA0
6ES7321-1FF01-0AA0
6ES7321-1FF81-0AA0
6ES7321-1FH00-0AA0
6ES7321-7BH00-0AB0 A)
6ES7321-7BH01-0AB0 A)
6ES7321-7BH80-0AB0 A)
6ES7321-7RD00-0AB0 B)
6ES7322-1BF00-0AA0
6ES7322-1BF01-0AA0
6ES7322-1BH00-0AA0
6ES7322-1BH01-0AA0
6ES7322-1BH10-0AA0
6ES7322-1BH81-0AA0
6ES7322-1BL00-0A00
6ES7322-1BP00-0AA0
6ES7322-1BP50-0AA0 C)
6ES7322-1CF00-0AA0
6ES7322-1CF80-0AA0
6ES7322-1EH00-0AA0
6ES7322-1EH01-0AA0
6ES7322-1EL00-0AA0
6ES7322-1FF00-0AA0
6ES7322-1FF01-0AA0
6ES7322-1FF81-0AA0
6ES7322-1FH00-0AA0
6ES7322-1FL00-0AA0
6ES7322-1HF80-0AA0
6ES7322-5RD00-0AB0 D)
6ES7322-5SD00-0AB0 D)
6ES7322-8BF00-0AB0
6ES7322-8BF00-0AB0
6ES7322-8BH01-0AB0
6ES7322-8BH01-0AB0
6ES7323-1BH00-0A00
6ES7323-1BH01-00A0
DI/DO
6ES7323-1BH80-0AA0
6ES7323-1BH80-0A00
6ES7323-1BL00-0AA0
1327330000 – 2012/2013
Number/Type of channels
16 DI
16 DI
16 DI
16 DI
16 DI
16 DI
16 DI
32 DI
32 DI
64 DI, positive logic
64 DI, negative logic A)
16 DI
16 DI
16 DI
16 DI
16 DI
8 DI
8 DI
8 DI
16 DI
16 DI
16 DI
16 DI
16 DI
8 DO
8 DO
16 DO
16 DO
16 DO
16 DO
32 DO
64 DO
64 DO
8 DO
8 DO
16 DO
16 DO
32 DO
8 DO
8 DO
8 DO
16 DO
32 DO
8 DO
4 DO
4 DO
8 DO, without redundancy
8 DO, with redundancy
16 DO, without redundancy
16 DO, with redundancy
8 DI
8DO
8 DI
8 DO
8 DI
8 DO
8 DI
8 DO
16 DI
16 DO
Cables
Interfaces
Standard
Order No.
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789236xxx
7789236xxx
7789771xxx
7789768xxx
7789211xxx
7789211xxx
7789212xxx
7789212xxx
7789215xxx
7789219xxx
7789219xxx
7789219xxx
7789212xxx
7789210xxx
7789210xxx
7789210xxx
7789801xxx
7789239xxx
7789239xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789236xxx
7789246xxx
7789246xxx
7789191xxx
7789191xxx
7789211xxx
7789211xxx
7789211xxx
7789219xxx
7789219xxx
7789219xxx
7789211xxx
7789211xxx
7789190xxx
7789192xxx
7789192xxx
7789239xxx
7789830xxx
7789729xxx
7789730xxx
7789237xxx
A
Universal solutions for PLC input/
output cards
PLC SIEMENS – S7-300/ET- 200M
Quantity
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1
1
1
1
7789237xxx
1
7789237xxx
1
7789237xxx
1
7789236xxx
1
Direct inputs/outputs
Insulated inputs
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
H2016
4
H2016
4
R2416
1
R2416
1
R2416
1
R2416
1
R3632
1
R1208
1
R1208
1
R1208
1
R2416
1
R2416
1
R2416
1
R2416
1
H20
1
H2008
1
H2008
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
4
H2016
4
R1208
1
R1208
1
R2416
1
R2416
1
R2416
2
R1208
1
R1208
1
R1208
1
R2416
1
R2416
2
R2416
1
H2016
1
H2016
1
H2008
1
H2008
1
H2016
1
H2016
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2016
1
H2016
1
- see page A.66 Type
Quantity
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
2
I2016
2
I2016
4
Insulated outputs
- see page A.70 Type
Quantity
O2008
O2008
O2016
O2016
O2016
O2016
O2016
O2016
O2016
1
1
1
1
1
1
2
4
4
O2008
O2008
O2016
O2016
1
1
1
1
O2008
I2016
A
Wide range of passive interfaces
The range includes passive input/output
interfaces for digital and analogue signals.
The interfaces are available in screw or tension
clamp connection and the sensors/actuators
can be connected with 1, 2 or 3 wires,
whichever is needed. You can also choose from
a large variety of functions:
•LED indication
•Fuse
•Circuit Breaker
•Test leads
1
O2008
1
O2008
1
O2008
1
O2016
1
1
A.33
Wide range of relay insulated interfaces
Available in versions with 8-12 and 16 relays,
the RSM family offers the possibility of
insulating digital signals both in input and
output cards. Options include our compact
format (6 mm relays) or standard (RCL relay),
with additional features including:
•Switch in coil and contact
•Fuse in contact
•1 or 2 CO contacts
1327330000 – 2012/2013
A.3
Universal solutions for PLC input/
output cards
Introduction
Universal solutions for PLC input/output cards
The increasing complexity of machinery and facilities in the
industry means that attention is being drawn to the resulting
rise in the costs of wiring. Traditional end-to-end cabling
between the PLC and the field components has many
drawbacks:
A
• High assembly costs: Time-consuming routing and
assembly of connecting leads.
• The risk of wiring mistakes increases in proportion with
the number of individual wires at one end.
• Individual wires occupy a considerable amount of space
in the cabinet.
• High installation and implementation time.
• High labelling and documentation workload
Weidmüller offers a complete line of pre-assembled cables,
together with a range of compact interfaces, to connect with
the main commercial PLCs:
• ABB S88
• Emerson Delta V
• Ge Fanuc 90-30 and RX3i
• Honeywell C200
• Mitsubishi Melsec
• Omron C200, CJ1 and CQM1
• Rockwell Compact Logix , Control Logix,
Micro Logix and SLC500
• Schneider Micro, Premium, Twido, Quantum,
M340 and M258
• Siemens S7-200,S7-300,S7-400 and S7-1200
A.4
PLC interface
The range includes passive input/output interfaces for digital
and analogue signals and relay boards to insulate the input
and output signals. These modules accept all common
commercial connectors and are available for screw or
tension clamp connection.
The Weidmüller universal interfaces for the PLC have the
following individual components:
• Extruded profile for inserting the PCB
• Clip-on feet for locking on standardised mounting rails
TS 32 and TS 35
• Printed circuit board where the following elements can
be identified
–Plug-in connectors to the PLC (Ribbon cable,
RSV or SUB-D)
–Weidmüller terminals for screw or tension clamp
connection
–Electronic or mechanical components offering
additional functions: LED, relays, fuses…
These interfaces are universal: the same interface can
be used by different PLCs from different manufacturers.
Pre-assembled cables are responsible for adequately
communicating the PLC with its field components.
Digital input/output interfaces (H System)
The digital input/output interfaces have been designed using
a ribbon cable connector suitable for the majority of signals
coming from the PLC. In addition, the pre-assembled cables
are designed using a cross-section of 0.25 mm2 and have a
cover that guarantees complete and safe fastening with the
interface connector.
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Introduction
The range has been designed for 4, 8,12,16 and 32 signals
in tension clamp or screw connection and you can choose
additional functions including:
2-wire system:
The 2 wires of the field element are connected to the
interface with power bus in one of them.
• LED
• Fusible
• Interruptor
A
0.0
C
Additionally, sensors/actuators can be connected using
1-, 2-, or 3-wire techniques; this way, the space that is
usually needed for connecting the common power supply
points, which are normally connected via additional
terminals, is not required.
0.1
1-wire system:
In field components, one of the wires is connected to the
interface while the other is connected to a common power
supply point (for example a terminal block).
0.7
C
C
+
0.0
0.1
C
+
–
–
0.7
+
+
–
–
3-wire system:
The interface is designed for 3 wire field components, with
one for positive, one for negative and one for the signal that
is sent to the PLC.
+
0.0
–
+
0.1
–
+
1.7
–
+
+
–
1327330000 – 2012/2013
–
A.5
Universal solutions for PLC input/
output cards
Introduction
Universal solutions for PLC input/output cards
Digital input/output interfaces for high voltage
(R System)
A
The digital signals used by PLCs are usually 24V DC or a
maximum of 48 V DC. Nevertheless, a few cards also work
at higher voltages, up to 230 V AC. For these voltages, the
insulation distance between channels has to be increased up
to values that the ribbon cable connector is not able provide.
In this case, interfaces supplied with RSV connectors have
been included in the range.
Insulated digital input/output interfaces
The insulated digital input/output interfaces are used,
when necessary, to isolate the PLC signal from the field
signal, normally when adapting voltages between the field
components and the PLC operational voltage.
The current provided by the PLC is not high enough for the
different field components in the output cards. In this case,
the relay acts like an amplifier and offers enough power to
connect the different elements, such as, for example, electro
valves.
The RSM family, available in 8,12, and 16 relay versions
connects to the PLC with a ribbon cable and is available in
compact form (6 mm relays) or standard (RCL relay) and
includes additional features such as:
• Switch in coil and contact
• Fuse in contact
• 1 or 2 CO contacts
In addition, the relays also can be replaced by the
Weidmüller opto modules.
((Prüfen))
Analogue input/output interfaces (S System)
A.6
The analogue input/output interfaces have been designed
using a shielded SUB-D connector, ideal for avoid
interferences in the transmission of analogue signals.
The pre-assembled cables are also supplied with shielded
cable.
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Introduction
Pre-assembled cables
The connection using pre-assembled cables drastically
reduces the connection work between the PLC and the field
components.
Table of colour codes according to DIN 47.100
Nº
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Colour
White
Brown
Green
Yellow
Grey
Pink
Blue
Red
Black
Violet
Grey/Pink
Red/Blue
White/Green
Brown/Green
White/Yellow
Yellow/Brown
White/Grey
Grey/Brown
White/Pink
Pink/Brown
White/Blue
Nº
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
Colour
Brown/Blue
White/Red
Brown/Red
White/Black
Brown/Black
Grey/Green
Yellow/Grey
Pink/Green
Yellow/Pink
Green/Blue
Yellow/Blue
Green/Red
Yellow/Red
Green/Black
Yellow/Black
Grey/Blue
Pink/Blue
Grey/Red
Pink/Red
Grey/Black
Pink/Black
Nº
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
Each pre-assembled cable has the following features:
Tables and automatic selection guides:
• PLC connector: The original connector of the
manufacturer is used.
• Interface Connector: 3 types of connectors are used
according to the interface they connect to.
–Ribbon cable connectors - which are supplied with a
hood to protect them from cable extraction forces and
ensure secure and reliable connection.
– Very sturdy RSV connectors that allow working with
high voltages of up to 230 V.
–SUB-D connectors, where the wire screening for
analogue signals is connected directly to the metallic
body of the connector to minimise the effect of
electromagnetic interferences.
• Cable: A multipole 0.25 mm2 cross-section wire is used.
This is also shielded for analogue signal cables. Each of
the individual wires is identified by means of a colour
code according to DIN 47.100.
To help you choose the right products for your application,
Weidmüller offers a catalogue with a selection of tables
which can be found on the following pages.
1327330000 – 2012/2013
A
Colour
Blue/Black
Red/Black
White/Brown/Black
Yellow/Green/Black
Grey/Pink/Black
Blue/Red/Black
White/Green/Black
Green/Brown/Black
White/Yellow/Black
Yellow/Brown/Black
White/Grey/Black
Grey/Brown/Black
White/Pink/Black
Pink/Brown/Black
White/Blue/Black
Brown/Blue/Black
White/Red/Black
Brown/Red/Black
Black/White
In addition, on our website, we have an automatic selection
guide, using intuitive software that can help you to choose
the appropriate interface cable for your Input/Output cards.
This can be found at www.weidmueller.com
A.7
Universal solutions for PLC input/
output cards
Introduction
Universal solutions for PLC input/output cards
Advantages of the system:
A
The combination of pre-assembled cables and the interfaces
allows the final connecting system to be:
• Safe
– It excludes the risk of errors in cabling
• Fast
The use of pre-assembled cables means there are real
savings in time:
– during design, thanks to the selection guides.
– during assembly.
– during startup.
– in the detection/resolution of problems.
• Reliable
– no cabling errors,
– clean cabling in cabinet
(multi-pole cables instead of single cables)
• Flexible
– a multitude of input/output interfaces
– variable cable lengths,
– expansions can be made without any problem.
– flexibility thanks to the simplicity of interchanging and
diverse input/output interfaces.
– easy migration to another system, simply by changing
the pre-assembled cable.
•Small-space reduction
– more space in the cable ducts,
– narrow modules,
– no terminal block
A.8
1327330000 – 2012/2013
A
1327330000 – 2012/2013
A.9
Universal solutions for PLC input/
output cards
Universal solutions for PLC input/
output cards
Introduction
PLC interface selection tables
A
PLC SIEMENS – S7-300/ET- 200M
Universal solutions for PLC input/
output cards
Selection guide
4
1
Universal solutions for PLC input/
output cards
A.38
Cables
Standard
Number/Type of channels
16 DI
16 DI
16 DI
16 DI
16 DI
16 DI
16 DI
32 DI
32 DI
64 DI, positive logic
6ES7321-1BP00-0AA0
64 DI, negative logic A)
6ES7321-1CH20-0AA0
16 DI
DI
6ES7321-1CH80-0AA0
16 DI
Selection guide
6ES7321-1EH00-0AA0
16 DI
6ES7321-1EH01-0AA0
16 DI
6ES7321-1EL00-0AA0
16 DI
6ES7321-1FF00-0AA0
8 DI
6ES7321-1FF01-0AA0
RS IO – Selection guide for passive
interfaces 8 DI
6ES7321-1FF81-0AA0
8 DI
for digital signals
6ES7321-1FH00-0AA0
16 DI
16 DI
6ES7321-7BH00-0AB0 A)
A)
Type
Features
Interfaces
16 DI
6ES7321-7BH01-0AB0
Number of
Family
Type of wiring
Connection
LED by channel
Disconnectable
Fuse
Order No.
Type
Page
channels
Screw
Tension clamp
16 DI
6ES7321-7BH80-0AB0 A)
connection
B)
V
L
9445530000
RS
8IO
2W L H S
A.40
H2008
2-wire
6ES7321-7RD00-0AB0
16 DI
8-channel
V
9441540000 RS 8IO 2W R S
A.41
R1208
2-wire
6ES7322-1BF00-0AA0
89445630000
DO
V
L
12-channel
H2012
2-wire
RS 12IO 2W L H S
A.42
6ES7322-1BF01-0AA0
8
DO
V
9445700000 RS 16IO 1W H S
A.43
V
L
9445710000
RS 16IO 1W L H S
A.43
6ES7322-1BH00-0AA0
16
DO
Z
1311750000 RS 16IO 1W H Z
A.43
1-wire
Z 6ES7322-1BH01-0AA0
L
1311770000
RS 16IO 1W L H Z
A.43
16
DO
V
L
I
9445810000 RS 16IO 1W I-L H S
A.44
Z 6ES7322-1BH10-0AA0
L
I
1311780000
RS
16IO
1W
I-L
H
Z
A.44
169445720000
DO RS 16IO 2W H S
V
A.45
V
L
9445730000 RS 16IO 2W L H S
A.45
6ES7322-1BH81-0AA0
161311790000
DO RS 16IO 2W H Z
Z
A.45
Z
L
1311800000 RS 16IO 2W L H Z
A.45
6ES7322-1BL00-0A00
32
DO
V
I
1311810000 RS 16IO 2W I H S
A.46
H2016
V
L
I
9445750000 RS 16IO 2W I-L H S
A.46
6ES7322-1BP00-0AA0
64
DO
2-wire
Z
I
1311820000 RS 16IO 2W I H Z
A.46
Z
L
I
1311830000 RS 16IO 2W I-L H Z
A.46
16-channel
C)
64
DO
6ES7322-1BP50-0AA0
V
F
9445820000 RS 16IO 2W F H S
A.47
V
L
F
RS 16IO 2W F-L H S
A.47
6ES7322-1CF00-0AA0
81311850000
DO
Z
F
1311840000 RS 16IO 2W F H Z
A.47
Z
L
F
1311870000 RS 16IO 2W F-L H Z
A.47
6ES7322-1CF80-0AA0
89445760000
DO
V
RS 16IO 3W H S
A.48
V
L
9445770000 RS 16IO 3W L H S
A.48
3-wire
161311880000
DO RS 16IO 3W H Z
Z 6ES7322-1EH00-0AA0
A.48
Z
L
1311890000 RS 16IO 3W L H Z
A.48
6ES7322-1EH01-0AA0
16
DO
V
9441500000 RS 16IO 1W R S
A.49
1-wire
DO
V
I
9441860000 RS 16IO 1W I R S
A.49
6ES7322-1EL00-0AA0
32
DO
V
R2416
9441700000 RS 16IO 2W R S
A.50
2-wire
V
F
9441560000 RS 16IO 2W F R S
A.50
6ES7322-1FF00-0AA0
89441600000
DO
V
I
RS 16IO 3W I R S
A.51
3-wire
6ES7322-1FF01-0AA0
89445900000
DO
V
RS 32IO 1W H S
A.52
V
L
9445910000 RS 32IO 1W L H S
A.52
1-wire
6ES7322-1FF81-0AA0
89445870000
DO
V
L
I
RS 32IO 1W I-L H S
A.53
V
L
9445930000 RS 32IO 2W L H S
A.54
H2032
6ES7322-1FH00-0AA0
169445950000
DO RS 32IO 2W I-L H S
2-wire
V
L
I
A.54
V
F
9445980000 RS 32IO 2W F H S
A.55
6ES7322-1FL00-0AA0
329445960000
DO RS 32IO 3W H S
32-channel
V
A.56
3-wire
V
L
9445970000 RS 32IO 3W L H S
A.56
6ES7322-1HF80-0AA0
89441510000
DO
V
RS 32IO 1W R S
A.57
1-wire
V
I
9441870000 RS 32IO 1W I R S
A.57
D)
4
DO
6ES7322-5RD00-0AB0
V
R3632
9441710000
RS 32IO 2W R S
A.58
2-wire
V
F
9441570000 RS 32IO 2W F R S
A.58
D)
V
I
RS 32IO 3W I R S
A.59
3-wire
49441610000
DO
6ES7322-5SD00-0AB0
Coding of the interface descriptions
RS 8IO: 8 inputs/outputs
1W:1-wire
(empty): Direct
H HE connector (ribbon cable) S: Screw
Note 1:
12IO: 12 inputs/outputs
2W:2-wire
I: Switch
R: RSV connector
Z: Tension clamp connection
6ES7322-8BF00-0AB0
8 DO, without redundancy
16IO:
16 inputs/outputs
3W:3-wire
L: LED
32IO: 32 inputs/outputs
Number of wires
F: Fuse
I-L Switch + LED
6ES7322-8BF00-0AB0F-L: Fuse + LED 8 DO, with redundancy
2 units of the following products from the
Note 2:
16 DO,
without
redundancy
9445700000 RS 6ES7322-8BH01-0AB0
16IO 1W H S
2 units
9445900000
RS 32IO
1W H S
1 unit
H2016 family can be replaced by 1 unit
9445710000 RS 16IO 1W L H S
2 units
9445910000 RS 32IO 1W L H S
1 unit
from the H2032 family
16 DO,
with
9445810000 RS 6ES7322-8BH01-0AB0
16IO 1W I-L H S
2 units
9445870000
RS 32IO
1W I-L Hredundancy
S
1 unit
9445730000 RS 16IO 2W L H S
2 units
9445930000 RS 32IO 2W L H S
1 unit
8 DI RS 32IO 2W I-L H S
9445750000 RS 16IO 2W I-L H S
2 units
9445950000
1 unit
9445820000 RS 6ES7323-1BH00-0A00
16IO 2W F H S
2 units
9445980000 RS 32IO 2W F H S
1 unit
8DO RS 32IO 3W H S
9445760000 RS 16IO 3W H S
2 units
9445960000
1 unit
9445770000 RS 16IO 3W L H S
2 units
9445970000 RS 32IO 3W L H S
1 unit
8 DI
6ES7323-1BH01-00A0
8 DO
8 DI
DI/DO
6ES7323-1BH80-0AA0
8 DO
1327330000 – 2012/2013
8 DI
6ES7323-1BH80-0A00
8 DO
16 DI
6ES7323-1BL00-0AA0
16 DO
2
A
PLC
Input/Output cards
Manufacturer code
6ES7321-1BH00-0AA0
6ES7321-1BH01-0AA0
6ES7321-1BH02-0AA0
6ES7321-1BH50-0AA0
6ES7321-1BH80-0AA0
6ES7321-1BH81-0AA0
6ES7321-1BH82-0AA0
6ES7321-1BL00-0AA0
6ES7321-1BL80-0AA0
5
6
A.10
7
Interfaces
Order No.
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789236xxx
7789236xxx
7789771xxx
7789768xxx
7789211xxx
7789211xxx
7789212xxx
7789212xxx
7789215xxx
7789219xxx
7789219xxx
7789219xxx
7789212xxx
7789210xxx
7789210xxx
7789210xxx
7789801xxx
7789239xxx
7789239xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789236xxx
7789246xxx
7789246xxx
7789191xxx
7789191xxx
7789211xxx
7789211xxx
7789211xxx
7789219xxx
7789219xxx
7789219xxx
7789211xxx
7789211xxx
7789190xxx
7789192xxx
7789192xxx
7789239xxx
7789830xxx
7789729xxx
7789730xxx
Quantity
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1
1
1
7789237xxx
1
7789237xxx
1
7789237xxx
1
7789237xxx
1
7789236xxx
1
Direct inputs/outputs
Insulated inputs
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
H2016
4
H2016
4
R2416
1
R2416
1
R2416
1
R2416
1
R3632
1
R1208
1
R1208
1
R1208
1
R2416
1
R2416
1
R2416
1
R2416
1
H20
1
H2008
1
H2008
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
4
H2016
4
R1208
1
R1208
1
R2416
1
R2416
1
R2416
2
R1208
1
R1208
1
R1208
1
R2416
1
R2416
2
R2416
1
H2016
1
H2016
1
H2008
1
H2008
1
H2016
1
H2016
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2016
1
H2016
1
- see page A.66 Type
Quantity
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
2
I2016
2
I2016
4
Insulated outputs
- see page A.70 Type
Quantity
A
3
O2008
1
O2016
O2016
O2016
O2016
O2016
O2016
1
1
1
2
4
4
The selection tables help you to choose the
O2008pre-assembled
1
O2016
1
cables and interfaces.
1Select the PLC card from the corresponding table
Example:
• PLC: Siemens S7-300
• Card: 6ES7321-1BH82-0AA0
2Check the code of the cable to be ordered:
Example:
• Cable code 7789234xxx
• Quantity: 1 unit (by card)
The last 3 digits indicate the length:
For example 015 indicates 1.5 m
I2016
O2008
O2008
O2016
O2016
1
1
1
1
O2008
1
O2008
1
O2008
1
O2008
1
O2016
1
1
1327330000 – 2012/2013
1327330000 – 2012/2013
A.33
Universal solutions for PLC input/
output cards
Introduction
3Locate the exact family of modules and the
quantity you require
Example:
• H2016 System Quantity: 1 unit (by card)
or
• I2016 System Quantity: 1 unit (by card)
Take the notes into account (if there are any)
The portfolio includes:
Passive digital input/output interfaces
(H System)
H20: Universal interface for pin to pin 20 pole ribbon
cable (see chapter C)
H2008: Passive input/output 8-channel digital interface
H2012: Passive input/output 12-channel digital interface
H2016: Passive input/output 16-channel digital interface
H2032: Passive input/output 32-channel digital interface
H40: Universal interface for pin to pin 40 pole ribbon
cable (see chapter C)
P
assive digital input/output interfaces for high
voltage (R System)
R1208: Passive input/output 8-channel digital interface
(for high voltage)
R2416: Passive input/output 16-channel digital interface
(for high voltage)
R3632: Passive input/output 32-channel digital interface
(for high voltage)
Passive analogue output/input interfaces
(S System)
A15: Universal interface for pin to pin SUB-D 15 male
poles (see catalogue C)
A25: Universal interface for pin to pin SUB-D 25 male
poles (see catalogue C)
A1504: Passive input/output 4-channel analogue
interface
A2508: Passive input/output 8-channel analogue
interface
A3716: Passive input/output 16-channel analogue
interface
A1504M: Passive input/output 4-channel analogue
interface (specific)
A2508P: Passive input/output 8-channel analogue
interface (specific)
A2509M: Passive input/output 8+1-channel analogue
interface (specific)
1327330000 – 2012/2013
Relay insulated digital output/input interfaces
O2008: 8-channel insulated digital output interface
O2012: 12-channel insulated digital output interface
O2016: 16-channel insulated digital output interface
I2016: 16-channel insulated digital input interface
A
4Note the page number that is shown in the top part
of the column
Example:
• H2016 System -> See page A.38
or
• I2016 System -> See page A.66
5 O
nce the module family is chosen (step 3 - eg H2016), go
to the page identified in step 4 and locate that family in
the new table on that page.
6Choose the interface according to your application needs
ie. 1, 2 or 3 wires, screw or tension clamp connection,
with fuse, LED, switch, etc.
7 G
o to the specifications page where you can check all the
details of the interface.
A.11
Universal solutions for PLC input/
output cards
Selection guide
PLC ABB S800
A
DI
DO
AI
AO
Note
PLC
Cables
Input/Output cards
Standard
Manufacturer code
DI810
DI811
DI814 A)
DI830
DI831
DI840
DI880
DO810
DO814 B)
DO815
DO840
DO880
AI810 C)
AI820 C)
AI830 C)
AI830A C)
AI845 C)
AO810 C)
AO810V2 C)
AO820 C)
AO845 C)
Number/Type of channels
16 DI
16 DI
16 DI
16 DI
16 DI
16 DI
16 DI
16 DO
16 DO
16 DO
16 DO
16 DO
8 AI
4 AI
8 AI
8 AI
8 AI
8 AO
8 AO
4 AO
8 AO
Order No.
7789641xxx
7789642xxx
7789641xxx
7789641xxx
7789642xxx
7789641xxx
7789641xxx
7789641xxx
7789641xxx
7789643xxx
7789641xxx
7789641xxx
7789657xxx
7789657xxx
7789657xxx
7789657xxx
7789657xxx
7789657xxx
7789657xxx
7789657xxx
7789657xxx
Interfaces
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Direct inputs/outputs
Insulated inputs
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
1
R2416
1
H0216
1
H2016
1
R2416
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
A25
1
A25
1
A25
1
A25
1
A25
1
A25
1
A25
1
A25
1
A25
1
- see page A.66 Type
Quantity
I2016
1
I2016
I2016
1
1
I2016
I2016
1
1
Insulated outputs
- see page A.70 Type
Quantity
O2016
O2016
O2016
O2016
O2016
1
1
1
1
1
A) Attention! Only use interfaces without LEDs
B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
C) Attention! Only use these interfaces: 8537370000 or 8005181001. More information in chapter C
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
•Use with 812TU MTU
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.12
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC EMERSON DELTA V
DI
DO
AI
AO
Note
PLC
Cables
Input/Output cards
Standard
Manufacturer code
VE4001S2T1B1 A)
VE4001S2T1B2 A)
VE4001S2T1B3 A)
VE4001S2T2B1 A)
VE4001S2T2B2 A)
VE4001S2T2B3 A)
VE4001S2T2B4 A)
VE4001S2T2B5 A)
VE4001S3T1B1
VE4001S3T1B2
VE4001S3T2B1
VE4001S3T2B2
VE4002S1T1B1 A)
VE4002S1T1B2 A)
VE4002S1T1B3 A)
VE4002S1T2B1 A)
VE4002S1T2B2 A)
VE4002S1T2B3 A)
VE4002S1T2B4 A)
VE4002S1T2B5 A)
VE4002S1T2B6 A)
VE4002S2T1B2
VE4002S2T2B1
VE4002S2T2B2
VE4003S2B1
VE4003S2B2
VE4003S2B3
VE4003S2B4
VE4003S2B6
VE4003S3B3
VE4003S3B4
VE4003S6B1
VE4005S2B1
VE4005S2B2
VE4005S2B3
Number/Type of channels
8 DI
8 DI
8 DI
8 DI
8 DI
8 DI
32 DI
32 DI
8 DI
8 DI
8 DI
8 DI
8 DO
8 DO
8 DO
8 DO
8 DO
8 DO
8 DO
32 DO
32 DO
8 DO
8 DO
8 DO
8 AI
8 AI
8 AI
8 AI
16 AI
8 AI
8 AI
8 AI
8 AO
8 AO
8 AO
Order No.
7789100xxx
7789100xxx
7789701xxx
7789100xxx
7789100xxx
7789701xxx
7789100xxx
7789702xxx
7789104xxx
7789104xxx
7789104xxx
7789104xxx
7789100xxx
7789100xxx
7789701xxx
7789100xxx
7789100xxx
7789700xxx
7789703xxx
7789100xxx
7789702xxx
7789108xxx
7789104xxx
7789104xxx
7789252xxx
7789252xxx
7789252xxx
7789704xxx
7789254xxx
7789252xxx
7789704xxx
7789254xxx
7789252xxx
7789252xxx
7789704xxx
Interfaces
Direct inputs/outputs
Quantity
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
R2416
1
R2416
1
R2416
1
R2416
1
H2008
1
H2008
1
H2016
1
H2008
1
H2008
1
H2008
1
H2008
1
H2016
2
H2016
2
R1208
1
R2416
1
R2416
1
A2508
1
A2508
1
A2508
1
A2508
1
A3716
1
A2508
1
A2508
1
A3716
1
A2508
1
A2508
1
A2508
1
Insulated inputs
- see page A.66 Type
Quantity
Insulated outputs
- see page A.70 Type
Quantity
A
A) Attention! Only use interfaces without LEDs
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
•Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end.
These cables do not have a PLC connector. Colour code according to DIN 47100.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.13
Universal solutions for PLC input/
output cards
Selection guide
PLC GEFANUC 90-30
A
DI
DO
AO
AI/AO
Note
Cables
Standard
Manufacturer code
IC693MDL230
IC693MDL231
IC693MDL240
IC693MDL241
IC693MDL630
IC693MDL632
IC693MDL634
IC693MDL640
IC693MDL643
IC693MDL645
IC693MDL646
IC693MDL654
IC693MDL655
IC693MDL310
IC693MDL340
IC693MDL730
IC693MDL731 A)
IC693MDL732
IC693MDL733 A)
IC693MDL740
IC693MDL741 A)
IC693MDL742
IC693MDL752 A)
IC693MDL753
IC693MDL930
IC693ALG220
AI
PLC
Input/Output cards
IC693ALG221
IC693ALG222
IC693ALG223
IC693ALG390
IC693ALG391
IC693ALG392
IC693ALG392
IC693ALG442
Numero/Type canales
8 DI
8 DI
16 DI
16 DI, positive logic
8 DI
8 DI, positive logic
8 DI, positive logic
16 DI
16 DI
16 DI, positive logic
16 DI, positive logic
32 DI, positive logic
32 DI, positive logic
12 DO
16 DO
8 DO
8 DO
8 DO
8 DO
16 DO
16 DO
16 DO
32 DO
32 DO
8 DO
4 AI,
voltage differential applications
4 AI,
current applications
16 AI or 8 AI
16 AI
4 AO
4 AO
8 AO, current applications
8 AO, voltage applications
4 AI
2 AO
Interfaces
Direct inputs/outputs
- see page A.38 (H) or A.60 (A) Type
Quantity
R2416
1
R2416
1
R2416
1
H2016
1
H2008
1
R1208
1
H2008
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
R2416
1
R2416
1
H2008
1
H2016
1
H2008
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
R2416
1
Order No.
7789064xxx
7789064xxx
7789061xxx
7789067xxx
7789067xxx
7789634xxx
7789067xxx
7789067xxx
7789067xxx
7789067xxx
7789067xxx
7789066xxx
7789066xxx
7789063xxx
7789063xxx
7789069xxx
7789069xxx
7789068xxx
7789068xxx
7789068xxx
7789068xxx
7789068xxx
7789066xxx
7789066xxx
7798064xxx
Quantity
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
2
2
1
7789076xxx
1
A1504
1
7789075xxx
1
A1504
1
7789072xxx
7789072xxx
7789073xxx
7789073xxx
7789620xxx
7789624xxx
1
1
1
1
1
A2508
A2508
A2508
A2508
A1504
A1504
1
1
1
1
1
1
7789074xxx
1
A3716
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
1
I2016
I2016
I2016
I2016
1
1
2
2
Insulated outputs
- see page A.70 Type
Quantity
O2008
O2016
O2008
O2016
O2016
O2016
O2016
O2016
O2016
1
1
1
1
1
1
1
2
2
A) Attention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.14
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC GEFANUC RX3i
DI
DO
IC694ALG221
IC694ALG222
IC694ALG223
IC695ALG600
IC695ALG600
IC695ALG608
AO
AI/AO
Note
Cables
Standard
Manufacturer code
IC694MDL230
IC694MDL231
IC694MDL240
IC694MDL241
IC694MDL250
IC694MDL260
IC694MDL632
IC694MDL634
IC694MDL645
IC694MDL646
IC694MDL654
IC694MDL655
IC694MDL660
IC694MDL310
IC694MDL330
IC694MDL340
IC694MDL350
IC694MDL390
IC694MDL732
IC694MDL734
IC694MDL740
IC694MDL741 A)
IC694MDL742
IC694MDL752 A)
IC694MDL753
IC694MDL754
IC694MDL916
IC694MDL930
IC694MDL931
IC694MDL940
IC694ALG220
AI
PLC
Input/Output cards
IC695ALG616
IC695ALG616
IC694ALG390
IC694ALG391
IC694ALG392
IC694ALG392
IC695ALG704
IC695ALG708
IC695ALG808
IC694ALG442
Number/Type of channels
8 DI
8 DI
16 DI
16 DI, positive logic
16 DI
32 DI
8 DI, positive logic
8 DI, positive logic
16 DI, positive logic
16 DI, positive logic
32 DI, positive logic
32 DI, positive logic
32 DI
12 DO
8 DO
16 DO
16 DO
5 DO
8 DO
6 DO
16 DO
16 DO
16 DO
32 DO
32 DO
32 DO
16 DO
8 DO
8 DO
16 DO
4 AI, voltage differential
applications
4 AI, voltage differential
applications
16 AI
16 AI
8AI, resistance applications
8AI, voltage or current applications
8AI, common applications
16 AI, differential applications
8 AI, differential applications
16 AI, common mode applications
2 AO
2 AO
8 AO, current applications
8 AO, voltage applications
4 AO
8 AO
8 AO
4 AI
2 AO
Interfaces
Direct inputs/outputs
- see page A.38 (H) or A.60 (A) Type
Quantity
R2416
1
R2416
1
R2416
1
H2016
1
R3632
1
R3632
1
R1208
1
H2008
1
H2008
1
H2008
1
H2016
2
H2016
2
H2016
2
R2416
1
R1208
1
R2416
1
R3632
1
R2416
1
H2008
1
R2416
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
H2016
2
R3632
1
R2416
1
R3632
1
R2416
1
Order No.
7789064xxx
7789064xxx
7789061xxx
7789067xxx
7789631xxx
7789632xxx
7789634xxx
7789067xxx
7789067xxx
7789067xxx
7789066xxx
7789066xxx
7789619xxx
7789063xxx
7789634xxx
7789063xxx
7789631xxx
7789636xxx
7789068xxx
7789669xxx
7789068xxx
7789068xxx
7789068xxx
7789066xxx
7789066xxx
7789618xxx
7789696xxx
7789064xxx
7789665xxx
7789666xxx
Quantity
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
7789076xxx
1
A1504
1
7789075xxx
1
A1504
1
7789072xxx
7789072xxx
7789622xxx
7789623xxx
1
1
1
1
A2508
A2508
A3716
A3716
1
1
1
1
7789667xxx
1
A2508
1
7789626xxx
7789798xxx
7789073xxx
7789073xxx
7789620xxx
7789624xxx
7789668xxx
7789625xxx
7789621xxx
1
1
1
1
1
1
1
1
1
A3716
A3716
A2508
A2508
A1504
A1504
A1504
A2508
A2508
1
1
1
1
1
1
1
1
1
7789074xxx
1
A3716
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
1
I2016
I2016
I2016
I2016
I2016
1
1
2
2
2
Insulated outputs
- see page A.70 Type
Quantity
O2016
1
O2016
O2016
O2016
O2016
O2016
O2016
1
1
1
2
2
2
A
A) Attention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
*
always find the most up-to-date information.
1327330000 – 2012/2013
A.15
Universal solutions for PLC input/
output cards
Selection guide
PLC HONEYWELL C200
A
DI
DO
AI
AO
Note
PLC
Cables
Input/Output cards
Standard
Manufacturer code
TC-IDA161 / TK-IDA161
TC-IDD321 / TK-IDD321
TC-IDJ161 / TK-IDJ161
TC-IDK161 / TK-IDK161
TC-IDW161 / TK-IDW161
TC-IDX081 / TK-IDX081
TC-IDX161 / TK-IDX161
TC-ODA161 TK-ODA161
TC-ODD321 / TK-ODD321
TC-ODJ161 / TK-ODJ161
TC-ODK161 / TK-ODK161
TC-ODX081 / TK-ODX081
TC-ODX161 / TK-ODX161
TC-ORC081 / TK-ORC081
TC-ORC161 / TK-ORC161
TC-IAH061 / TK-IAH061
TC-IAH061 / TK-IAH061
TC-IAH161 / TK-IAH161
TC-IXR061 / TK-IXR061
TC-OAH061 / TK-OAH061
TC-OAV061 / TK-OAV161
TC-OAV081 / TK-OAV081
TC-OAV081 / TK-OAV081
Number/Type of channels
16 DI
32 DI
16 DI
16 DI
16 DI
8 DI
16 DI
16 DO
32 DO
16 DO
16 DO
8 DO
16 DO
8 DO
16 DO
6 AI, current applications
6 AI, voltage applications
16 AI
6 AI, resistances 0 to 550 Ω
6 AO
6 AO
8 AO, current applications
8 AO, voltage applications
Order No.
7789031xxx
7789041xxx
7789049xxx
7789030xxx
7789030xxx
7789048xxx
7789049xxx
7789056xxx
7789042xxx
7789059xxx
7789030xxx
7789057xxx
7789040xxx
7789155xxx
7789030xxx
7789156xxx
7789157xxx
7789032xxx
7789158xxx
7789159xxx
7789157xxx
7789037xxx
7789038xxx
Interfaces
Direct inputs/outputs
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
R2416
1
H2016
2
H2016
1
R3632
1
R3632
1
R1208
1
H2016
1
R2416
1
H2016
1
H2016
1
R3632
1
R1208
1
H2016
1
R2416
1
R3632
1
A2508
1
A2508
1
A3716
1
A2508
1
A2508
1
A2508
1
A2508
1
A2508
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
I2016
2
1
I2016
1
Insulated outputs
- see page A.70 Type
Quantity
O2016
O2016
1
1
O2016
1
A) Attention! Only use interfaces without LEDs
B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.16
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC MITSUBISHI MELSEC Q
DI
DO
QX41Y41P C)
QX48Y57 C)
AI
AO
Note
Cables
Standard
Manufacturer code
QX10
QX28
QX40 A)
QX40-S1 A)
QX41 A)
QX41-S1 A)
QX42 A)
QX42-S1 A)
QX50
QX70 A)
QX71 A)
QX72 A)
QX80
QX82
QX82-S1
QY10
QY18A
QY22
QY40P B)
QY41P B)
QY42P B)
QY50 B)
QY68A
QY70 B)
QY71 B)
QY80
QH42P C)
DI/DO
PLC
Input/Output cards
Q62AD-DGH
Q64AD
Q64AD-GH
Q68AD-G
Q68AD-G
Q68ADI
Q68ADV
Q62DA
Q62DA-FG
Q62DAN
Q64DA
Q64DAN
Q66DA-G
Q66DA-G
Q68DAI
Q68DAIN
Q68DAV
Q68DAVN
Number/Type of channels
16 DI
8 DI
16 DI
16 DI
32 DI
32 DI
64 DI
64 DI
16 DI
16 DI
32 DI
64 DI
16 DI
64 DI
64 DI
16 DO
8 DO
16 DO
16 DO
32 DO
64 DO
16 DO
8 DO
16 DO
32 DO
16 DO
32 DI
32 DO
32 DI
32 DO
8 DI
7 DO
2 AI
4 AI
4 AI
8 AI, current applications
8 AI, voltage applications
8 AI
8 AI
2 AO
2AO
2 AO
4 AO
4 AO
6 AO, current applications
6 AO, voltage applications
8 AO
8 AO
8 AO
8 AO
Interfaces
Direct inputs/outputs
Order No.
7789104xxx
7789108xxx
7789100xxx
7789100xxx
7789681xxx
7789681xxx
7789681xxx
7789681xxx
7789104xxx
7789100xxx
7789681xxx
7789681xxx
7789100xxx
7789683xxx
7789683xxx
7789104xxx
7789104xxx
7789104xxx
7789100xxx
7789708xxx
7789708xxx
7789100xxx
7789100xxx
7789100xxx
7789708xxx
7789100xxx
7789681xxx
7789708xxx
7789681xxx
7789708xxx
Quantity
1
1
1
1
1
1
2
2
1
1
1
2
1
2
2
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
7789100xxx
2
7789250xxx
7789250xxx
7789250xxx
7789684xxx
7789685xxx
7789252xxx
7789252xxx
7789250xxx
7789250xxx
7789250xxx
7789250xxx
7789250xxx
7789710xxx
7789711xxx
7789252xxx
7789252xxx
7789252xxx
7789252xxx
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
R2416
1
R1208
1
H2016
1
H2016
1
H2016
2
H2016
2
H2016
4
H2016
4
R2416
1
H2016
1
H2016
2
H2016
4
H2016
1
H2016
4
H2016
4
R2416
1
R2416
1
R2416
1
H2016
1
H2016
2
H2016
4
H2016
1
H2016
1
H2016
1
H2016
2
H2016
1
H2016
2
H2016
2
H2016
2
H2016
2
H2016
1
H2016
1
A1504
1
A1504
1
A1504
1
A2508
1
A2508
1
A2508
1
A2508
1
A1504
1
A1504
1
A1504
1
A1504
1
A1504
1
A2508
1
A2508
1
A2508
1
A2508
1
A2508
1
A2508
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
I2016
I2016
Insulated outputs
- see page A.70 Type
Quantity
A
1
4
4
O2016
O2016
O2016
O2016
O2016
O2016
O2016
O2016
1
2
4
1
1
1
2
1
O2016
2
O2016
2
O2016
1
A) Attention! Only use interfaces without LEDs
B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
C) Attention! Use only interfaces without LEDs for the direct options. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated outlet option
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
•Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end.
These cables do not have a PLC connector. Colour code according to DIN 47100.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.17
Universal solutions for PLC input/
output cards
Selection guide
PLC MOELLER XIOC
A
PLC
Cables
Input/Output cards
Standard
Manufacturer code
XIOC-16DI
DI
XIOC-16DI-AC
XIOC-16DI-AC110
XIOC-32DI
XIOC-8DI
DO
DI/DO
AI
AO
XIOC-12DO-R B)
XIOC-16DO
XIOC-16DO-S
XIOC-32DO
XIOC-8DO
XIOC-16DX
XIOC-8AI-I2
XIOC-8AI-U1
XIOC-8AI-U2
XIOC-2AO-U1-2AO-I2
XIOC-2AO-U2
XIOC-4AO-U1
XIOC-4AO-U2
XIOC-2AI-1AO-U1
AI/AO
XIOC-2AI-1A0-U1-I1
XIOC-4AI-2AO-U1
XIOC-4AI-2AO-U1-I1
Note
Number/Type of channels
16 DI, positive logic
16 DI, negative logic A)
16 DI
16 DI
32 DI, positive logic
32 DI, negative logic A)
8 DI, positive logic
8 DI, negative logic A)
12 DO
16 DO
16 DO
32 DO
8 DO
16 DI
16 DO
8 AI
8 AI
8 AI
4 AO
2 AO
4 AO
4 AO
2 AI
2 AO
2 AI
2 AO
4 AI
2 AO
4 AI
2 AO
Interfaces
Direct inputs/outputs
Insulated inputs
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
1
H2016
1
R2416
1
R2416
1
H2016
2
H2016
2
H2008
1
H2016
1
R2416
1
H2016
1
H2016
1
H2016
2
H2008
1
- see page A.66 Type
Quantity
I2016
1
Order No.
7789862xxx
7789863xxx
7789864xxx
7789864xxx
7789771xxx
7789768xxx
7789862xxx
7789863xxx
7789871xxx
7789865xxx
7789865xxx
7789866xxx
7789865xxx
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
7789872xxx
1
H2016
1
7789867xxx
7789867xxx
7789867xxx
7789868xxx
7789868xxx
7789868xxx
7789868xxx
1
1
1
1
1
1
1
A2508
A2508
A2508
A1504
A1504
A1504
A1504
1
1
1
1
1
1
1
7789870xxx
1
A1504
1
7789870xxx
1
A1504
1
7789869xxx
1
A2508
1
7789869xxx
1
A2508
1
I2016
Insulated outputs
- see page A.70 Type
Quantity
2
O2016
O2016
O2016
O2008
1
1
2
1
A) Attention! Only use interfaces without LEDs
B) The 24 V DC power supply should be provided externally
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.18
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC OMRON – C200H
PLC
Cables
Input/Output cards
Standard
Manufacturer code
IA121
IA122
IA122V
IA222V
ID001 A)
ID002
DI
ID211
ID212
ID216
ID217
DO
Note
IM211
IM212 A)
OA221
OA222V
OC221
OC222V
OC223
OC224V
OC225
OD211 B)
OD212 B)
OD213 B)
OD214
OD217
OD411 B)
Number/Type of channels
8 DI
16 DI
16 DI
16 DI
8 DI
8 DI
8 DI, positive logic
8 DI, negative logic A)
16 DI, positive logic
16 DI, negative logic A)
32 DI, positive logic
32 DI, negative logic A)
64 DI, positive logic
64 DI, negative logic A)
8 DI, 24 V DC applications
16 DI, 24 V DC applications
8 DO
12 DO
8 DO
12 DO
5 DO
8 DO
16 DO
16 DO
16 DO
8 DO
8 DO
12 DO
8 DO
Order No.
7789108xxx
7789104xxx
7789104xxx
7789104xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789771xxx
7789768xxx
7789771xxx
7789768xxx
7789100xxx
7789100xxx
7789108xxx
7789104xxx
7789108xxx
7789104xxx
7789108xxx
7789104xxx
7789104xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
Interfaces
Direct inputs/outputs
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
R1208
1
R2416
R2416
1
R2416
1
H2016
1
H2008
1
H2008
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
H2016
4
H2016
4
H2008
1
H2016
1
R1208
1
R2416
1
R1208
1
R2416
1
R1208
1
R2416
1
R2416
1
H2016
1
H2016
1
H2016
1
H2008
1
H2012
1
H2016
1
Insulated inputs
- see page A.66 Type
Quantity
Insulated outputs
- see page A.70 Type
Quantity
I2016
1
I2016
2
I2016
4
O2016
O2016
O2016
O2008
O2012
O2016
A
1
1
1
1
1
1
A) Attention! Only use interfaces without LEDs
B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
•Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end.
These cables do not have a PLC connector. Colour code according to DIN 47100.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.19
Universal solutions for PLC input/
output cards
Selection guide
PLC OMRON – CJ1W
A
PLC
Cables
Input/Output cards
Standard
Manufacturer code
IA111
IA201
ID211
DI
ID231
ID232
ID261
ID262
DO
DI/DO
Note
OA201
OC201
OC211
OD201 B)
OD202
OD211 B)
OD212
OD231 B)
OD232
OD233 B)
OD261 B)
OD262
OD263 B)
MD232
MD232 C)
Number/Type of channels
16 DI
8 DI
16 DI, positive logic
16 DI, negative logic A)
32 DI, positive logic
32 DI, negative logic A)
32 DI, positive logic
32 DI, negative logic A)
64 DI, positive logic
64 DI, negative logic A)
64 DI, positive logic
64 DI, negative logic A)
8 DO
8 DO
16 DO
8 DO
8 DO
16 DO
16 DO
32 DO
32 DO
32 DO
64 DO
64 DO
64 DO
16 DI, positive logic
16 DO
16 DI, negative logic
16 DO
Order No.
7789664xxx
7789648xxx
7789645xxx
7789833xxx
7789771xxx
7789768xxx
7789772xxx
7789767xxx
7789771xxx
7789768xxx
7789772xxx
7789767xxx
7789648xxx
7789649xxx
7789664xxx
7789650xxx
7789650xxx
7789794xxx
7789794xxx
7789793xxx
7789373xxx
7789373xxx
7789793xxx
7789373xxx
7789373xxx
7789328xxx
7789329xxx
7789329xxx
7789329xxx
Interfaces
Direct inputs/outputs
Quantity
1
1
1
1
1
1
1
1
2
2
2
2
1
1
1
1
1
1
1
1
1
1
2
2
2
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
R2416
1
R1208
1
H2016
1
H2016
1
H2016
2
H2016
2
H2016
2
H2016
2
H2016
4
H2016
4
H2016
4
H2016
4
R1208
1
R2416
1
R2416
1
H2016
1
H2008
1
H2016
1
H2016
1
H2016
2
H2016
2
H2016
2
H2016
4
H2016
4
H2016
4
H2016
1
H2016
1
H2016
1
H2016
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
1
I2016
2
I2016
2
I2016
4
I2016
4
Insulated outputs
- see page A.70 Type
Quantity
O2016
O2008
O2016
O2016
O2016
O2016
O2016
O2016
O2016
O2016
1
1
2
2
2
2
2
4
4
4
O2016
1
O2016
1
A) Attention! Only use interfaces without LEDs
B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
C) Attention! Use only interfaces without LEDs for the direct input option
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.20
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC OMRON – CQM1
DI
DO
Note
AI
AO
PLC
Cables
Input/Output cards
Standard
Manufacturer code
IA121
IA221
ID211 A)
ID211 A)
ID212
ID213
ID213 A)
OA221
OC221
OC222
OD211 B)
OD212 B)
OD213 B)
OD214
AD041
DA021
Number/Type of channels
8 DI
8 DI
8 DI, positive logic
8 DI, negative logic
16 DI, positive logic
32 DI, positive logic
32 DI, negative logic
8 DO
8 DO
16 DO
8 DO
16 DO
32 DO
16 DO
4 AI
2 AO
Order No.
7789108xxx
7789108xxx
7789100xxx
7789100xxx
7789100xxx
7789771xxx
7789768xxx
7789108xxx
7789104xxx
7789104xxx
7789663xxx
7789100xxx
7789793xxx
7789100xxx
7789252xxx
7789250xxx
Interfaces
Direct inputs/outputs
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
R1208
1
R1208
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
R1208
1
R2416
1
R2416
1
H2016
1
H2016
1
H2016
2
H2016
1
A2508
1
A1504
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
I2016
Insulated outputs
- see page A.70 Type
Quantity
A
1
2
O2016
O2016
O2016
O2016
1
1
2
1
A) Attention! Only use interfaces without LEDs
B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
•Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end.
These cables do not have a PLC connector. Colour code according to DIN 47100.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.21
Universal solutions for PLC input/
output cards
Selection guide
PLC ROCKWELL – COMPACT LOGIX
A
PLC
Cables
Input/Output cards
Standard
Manufacturer code
1769-IA16
1769-IA8I
1769-IM12
1769-IQ16
DI
1769-IQ16F
1769-IQ32
32 DI, positive logic
1769-IQ32 A)
32 DI, negative logic
1769-OA16
1769-OA8
1769-OB16
1769-OB16P
32 DI, positive logic
32 DI, negative logic A)
16 DO
8 DO
16 DO
16 DO
1769-OB32
32 DO
1769-OB32T
1769-OB8
1769-OV16
1769-OW16
1769-OW8
1769-OW8I
1769-IF4
1769-IF4
1769-IF4I
1769-IF4I
1769-IF8
1769-IF8
1769-OF2
1769-OF4CI
1769-OF8C
1769-OF8V
32 DO
8 DO
16 DO
16 DO
8 DO
8 DO
4 AI, current applications
4 AI, voltage applications
4 AI, current applications
4 AI, voltage applications
8 AI, current applications
8 AI, voltage applications
2 AO
4 AO
8 AO
8 AO
1769-IQ32T
DO
AI
AO
Note
Number/Type of channels
16 DI
8 DI
12 DI
16 DI, positive logic
16 DI, negative logic A)
16 DI, positive logic
16 DI, negative logic A)
Order No.
7789025xxx
7789016xxx
7789025xxx
7789770xxx
7789831xxx
7789770xxx
7789831xxx
7789770xxx
7789695xxx
7789831xxx
7789832xxx
7789005xxx
7789670xxx
7789024xxx
7789017xxx
7789769xxx
7789769xxx
7789769xxx
7789697xxx
7789006xxx
7789015xxx
7789769xxx
7789024xxx
7789017xxx
7789016xxx
7789026xxx
7789046xxx
7789027xxx
7789047xxx
7789028xxx
7789045xxx
7789029xxx
7789043xxx
7789044xxx
7789044xxx
Interfaces
Direct inputs/outputs
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
R2416
1
R2416
1
R2416
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
H2016
H2016
R2416
R1208
H2016
H2016
1
1
1
1
1
1
H2016
H2016
H2008
H2016
R2416
R1208
R2416
A1504
A1504
A1504
A1504
A2508
A2508
A1504
A1504
A2508
A2508
Insulated inputs
- see page A.66 Type
Quantity
I2016
1
I2016
1
I2016
2
I2016
1
Insulated outputs
- see page A.70 Type
Quantity
O2016
O2016
1
1
2
O2016
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
O2016
O2008
O2016
2
1
1
A) Attention! Only use interfaces without LEDs
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.22
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC ROCKWELL – CONTROL LOGIX
DI
DO
AI
AO
Note
PLC
Cables
Input/Output cards
Standard
Manufacturer code
1756-IA16
1756-IA16I
1756-IA8D
1756-IB16
1756-IB16D
1756-IB16I
1756-IB32
1756-IC16
1756-IH16I
1756-IM16I
1756-IN16
1756-OA16
1756-OA16I
1756-OA8
1756-OA8D
1756-OA8E
1756-OB16D
1756-OB16E
1756-OB16I
1756-OB32
1756-OB8
1756-OB8EI
1756-OC8
1756-OH8I
1756-ON8
1756-OV16E
1756-OW16I
1756-OX8I
1756-IF16
1756-IF6I
1756-IF6I
1756-IF8
1756-IF8
1756-IR6I
1756-OF4
1756-OF4
1756-OF6CI
1756-OF6VI
1756-OF8
1756-OF8
Number/Type of channels
16 DI
16 DI
8 DI
16 DI
16 DI
16 DI
32 DI
16 DI
16 DI
16 DI
16 DI
16 DO
16 DO
8 DO
8 DO
8 DO
16 DO
16 DO
16 DO
32 DO
8 DO
8 DO
8 DO
8 DO
8 DO
16 DO
16 DO
8 DO
16 AI
6 AI, current applications
6 AI, voltage applications
8 AI, current applications
8 AI, voltage applications
6 AI
4 AO, current applications
4 AO, voltage applications
6 AO, resistances 0 to 550 Ω
6 AO
8 AO, current applications
8 AO, voltage applications
Order No.
7789031xxx
7789030xxx
7789048xxx
7789039xxx
7789049xxx
7789049xxx
7789041xxx
7789031xxx
7789030xxx
7789030xxx
7789031xxx
7789056xxx
7789030xxx
7789057xxx
7789048xxx
7789048xxx
7789040xxx
7789058xxx
7789059xxx
7789042xxx
7789151xxx
7789152xxx
7789153xxx
7789154xxx
7789057xxx
7789058xxx
7789030xxx
7789155xxx
7789032xxx
7789156xxx
7789157xxx
7789035xxx
7789036xxx
7789158xxx
7789033xxx
7789034xxx
7789159xxx
7789157xxx
7789037xxx
7789038xxx
Interfaces
Direct inputs/outputs
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
R2416
1
R3632
1
R1208
1
H2016
1
H2016
1
H2016
1
H2016
2
R2416
1
R3632
1
R3632
1
R3632
1
R3632
1
R3632
1
R1208
1
R1208
1
R1208
1
H2016
1
H2016
1
H2016
1
H2016
2
H2008
1
H2008
1
R2416
1
R2416
1
R1208
1
H2016
1
R3632
1
R2416
1
A3716
1
A2508
1
A2508
1
A2508
1
A2508
1
A2508
1
A1504
1
A1504
1
A2508
1
A2508
1
A2508
1
A2508
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
I2016
I2016
I2016
Insulated outputs
- see page A.70 Type
Quantity
A
1
1
1
2
O2016
O2016
O2016
O2016
O2008
O2008
1
1
1
2
1
1
O2016
1
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.23
Universal solutions for PLC input/
output cards
Selection guide
PLC ROCKWELL MICRO LOGIX 1400
A
DI
DO
DI/DO
AI
AO
AI/AO
Note
PLC
Cables
Input/Output cards
Standard
Manufacturer code
1762-IA8
1762-IQ16
1762-IQ32T
1762-IQ8
1762-OA8
1762-OB16
1762-OB32T
1762-OB8
1762-OV32T A)
1762-OW16
1762-OW8
1762-OX6I
1762-IQ8OW6
1762-IQ8OW6 B)
1762-IF4
1762-IR4
1762-IR4 C)
1762-OF4
1762-IF2OF2
Number/Type of channels
16 DI
16 DI
16 DI, positive logic
16 DI, negative logic
8 DI
8 DO
16 DO
32 DO
8 DO
32 DO
16 DO
8 DO
6 DO
8 DI, positive logic
6 DO
8 DI, negative logic
6 DO
4 AI
4 AI, 2-wire applications
4 AI, 3 and 4-wire applications
4 AO
2 AI
2 AO
Interfaces
Direct inputs/outputs
Order No.
7789108xxx
7789100xxx
7789005xxx
7789670xxx
7789100xxx
7789108xxx
7789100xxx
7789006xxx
7789100xxx
7789006xxx
7789104xxx
7789108xxx
7789106xxx
7789100xxx
7789108xxx
7789100xxx
7789108xxx
7789250xxx
7789250xxx
7789252xxx
7789250xxx
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7789250xxx
1
- see page A.38 (H) or A.60 (A) Type
Quantity
R1208
1
H2016
1
H2016
2
H2016
2
H2008
1
R1208
1
H2016
1
H2016
2
H2008
1
H2016
2
R2416
1
R1208
1
R3632
1
H2008
1
R1208
1
H2016
1
R1208
1
A1504
1
A1504
1
A2508
1
A1504
1
A1504
Insulated inputs
- see page A.66 Type
Quantity
I2016
I2016
Insulated outputs
- see page A.70 Type
Quantity
1
2
O2016
O2032
O2008
O2016
1
2
1
2
1
A) Attention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
B) A ttention! Use only interfaces without LEDs for the direct input option
C) Attention! Only use Interfaces without insulators and test points
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
•Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end.
These cables do not have a PLC connector. Colour code according to DIN 47100.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.24
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC ROCKWELL – SLC 500
DI
DO
AI
AO
AI/AO
Note
PLC
Cables
Input/Output cards
Standard
Manufacturer code
1746-IB16
1746-IB32
1746-IB8
1746-IC16
1746-IN16
1746-ITB16
1746-ITV16
1746-IV16
1746-IV32 A)
1746-IV8 A)
1746-OA16
1746-OB16
1746-OB16E
1746-OB32
1746-OB32E
1746-OB8
1746-OBP16
1746-OBP8
1746-OG16 A)
1746-OV16 A)
1746-OV32 A)
1746-OV8 A)
1746-OVP16 A)
1746-OW16
1746-OW4
1746-OW8
1746-OX8
1746-NI4
1746-NI8
1746-NO4I
1746-NO4V
1746-NIO4I
1746-NIO4V
Number/Type of channels
16 DI
32 DI
8 DI
16 DI
16 DI, DC applications
16 DI
16 DI
16 DI
32 DI
8 DI
16 DO
16 DO
16 DO
32 DO
32 DO
8 DO
16 DO
8 DO
16 DO
16 DO
32 DO
8 DO
16 DO
16 DO, 24 V DC applications
4 DO
8 DO
8 DO
4 AI
8 AI
4 AO
4 AO
2 AI
2 AO
2 AI
2 AO
Interfaces
Direct inputs/outputs
Insulated inputs
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
1
H2016
2
H2008
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
1
R2416
1
H2016
1
H2016
1
H2016
2
H2016
2
H2008
1
H2016
1
H2008
1
H2016
1
H2016
1
H2016
2
H2016
1
H2016
1
H2016
1
R1208
1
R1208
1
R2416
1
A1504
1
A2508
1
A2508
1
A2508
1
- see page A.66 Type
Quantity
I2016
1
I2016
2
Order No.
7789001xxx
7789005xxx
7789100xxx
7789001xxx
7789001xxx
7789001xxx
7789000xxx
7789000xxx
7789670xxx
7789100xxx
7789728xxx
7789003xxx
7789003xxx
7789006xxx
7789006xxx
7789100xxx
7789003xxx
7789100xxx
7789003xxx
7789003xxx
7789006xxx
7789100xxx
7789003xxx
7789002xxx
7789108xxx
7789108xxx
7789104xxx
7789008xxx
7789011xxx
7789010xxx
7789010xxx
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7789009xxx
1
A1504
1
7789009xxx
1
A1504
1
1
I2016
I2016
I2016
I2016
I2016
Insulated outputs
- see page A.70 Type
Quantity
A
1
1
1
1
1
O2016
O2016
O2016
O2016
O2008
O2016
O2008
O2016
O2016
O2016
O2016
O2016
1
1
2
2
1
1
1
1
1
2
1
1
A) Attention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.25
Universal solutions for PLC input/
output cards
Selection guide
PLC SCHNEIDER – M258
A
DI
DO
DI/DO
AI
AO
Note
PLC
Cables
Input/Output cards
Standard
Manufacturer code
TM5SDI12D
TM5SDI2D A)
TM5SDI4A
TM5SDI4D A)
TM5SDI6A
TM5SDI6D A)
TM5SDO12T
TMSDO2T A)
TM5SDO4R
TM5SDO4T A)
TM5SDO4TA A)
TM5SDO6T A)
TM5SDO8TA
TM5SDM12DT
TM5SAI2H
TM5SAI2L
TM5SAI2PH B)
TM5SAI4H
TM5SAI4L
TM5SAI4PH B)
TM5SAO2H
TM5SAO2L
TM5SAO4H
TM5SAO4L
Number/Type of channels
12 DI
2 DI
4 DI
4 DI
6 DI
6 DI
12 DO
2 DO
4 DO
4 DO
4 DO
6 DO
8 DO
8 DI
4 DO
2 AI
2 AI
2 AI
4 AI
4 AI
4 AI
2 AO
2 AO
4 AO
4 AO
Interfaces
Direct inputs/outputs
Order No.
7789840xxx
7789100xxx
7789854xxx
7789100xxx
7789855xxx
7789100xxx
7789840xxx
7789100xxx
7789858xxx
7789100xxx
7789100xxx
7789100xxx
7789857xxx
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
7789859xxx
1
7789841xxx
7789841xxx
7789841xxx
7789841xxx
7789841xxx
7789841xxx
7789841xxx
7789841xxx
7789841xxx
7789841xxx
1
1
1
1
1
1
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
H2012
1
H20
1
R1208
1
H20
1
R1208
1
H20
1
H2012
1
H20
1
R1208
1
H20
1
H20
1
H20
1
H2008
1
H2008
1
H2008
1
A1504M
1
A1504M
1
A15
1
A1504M
1
A1504M
1
A15
1
A1504M
1
A1504M
1
A1504M
1
A1504M
1
Insulated inputs
- see page A.66 Type
Quantity
Insulated outputs
- see page A.70 Type
Quantity
O2012
1
O2008
1
O2008
1
A) Attention! Only use these interfaces: 8537110000 or 0224261001. More information in chapter C
B) A ttention! Only use these interfaces: 8233350000. More information in chapter C
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
•Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end.
These cables do not have a PLC connector. Colour code according to DIN 47100.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.26
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC SCHNEIDER – M340
Manufacturer code
BMX DAI 1602
DI
DO
BMX DAI 1603
BMX DAI 1604
BMX DDI 1602
BMX DDI 1603
BMX DDI 3202 K
BMX DDI 6402 K
BMX DAO 1605
BMX DDO 1602
BMX DDO 1612 B)
BMX DDO 3202 K
BMX DDO 6402 K
BMX DRA 0805
BMX DRA 1605
BMX DDM 16022
DI/DO
BMX DDM 16025
BMX DDM 3202 K
AI
AO
AI/AO
Note
BMX AMI 0410
BMX AMI 0410
BMX ART 0414
BMX ART 0814
BMX AMO 0210
BMX AMM 0600
BMX AMM 0600
PLC
Cables
Input/Output cards
Standard
Number/Type of channels
16 DI, negative logic A)
16 DI, positive logic
16 DI
16 DI
16 DI
16 DI
32 DI
64 DI
16 DO
16 DO
16 DO
32 DO
64 DO
8 DO
16 DO
8 DI
8 DO
8 DI
8 DO
16 DI
16 DO
4 AI, current applications
4 AI, voltage applications
4 AI
8 AI
2 AO
4 AI + 2 AO, current applications
4 AI + 2 AO, voltage applications
Interfaces
Direct inputs/outputs
Order No.
7789630xxx
7789382xxx
7789382xxx
7789382xxx
7789380xxx
7789382xxx
7789387xxx
7789387xxx
7789383xxx
7789380xxx
7789380xxx
7789387xxx
7789387xxx
7789633xxx
7789384xxx
Quantity
1
1
1
1
1
1
1
2
1
1
1
1
2
1
1
7789386xxx
1
7789635xxx
1
7789387xxx
1
7789638xxx
7789637xxx
7789639xxx
7789639xxx
7789640xxx
7789629xxx
7789628xxx
1
1
1
2
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
1
R2416
1
R2416
1
R2416
1
H2016
1
R2416
1
H2016
2
H2016
2
R2416
1
H2016
1
H2016
1
H2016
2
H2016
4
R2416
1
R2416
1
H2008
1
H2008
1
H2008
1
R1208
1
H2016
1
H2016
1
A1504
1
A1504
1
A3716
1
A3716
2
A1504
1
A1504
2
A1504
2
Insulated inputs
- see page A.66 Type
Quantity
I2016
1
I2016
I2016
2
2
Insulated outputs
- see page A.70 Type
Quantity
O2016
O2016
O2016
O2016
1
1
2
4
O2008
1
O2016
1
A
A) Attention! Only use interfaces without LEDs
B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.27
Universal solutions for PLC input/
output cards
Selection guide
PLC SCHNEIDER – MICRO
A
DI
DO
TSX DMZ 28AR
TSX DMZ 28DR
TSX DMZ 28DT
TSX DMZ 28DTK
TSX DMZ 64DTK
AI
AO
Note
Cables
Standard
Manufacturer code
TSX DEZ 08A4
TSX DEZ 08A5
TSX DEZ 12D2 A)
TSX DEZ 12D2K
TSX DEZ 32D2
TSD DSZ 32R5
TSX DSZ 32T2
TSX DSZ 04T22
TSX DSZ 08R5
TSX DSZ 08T2
TSX DSZ 08T2K
TSX DMZ 16DTK
DI/DO
PLC
Input/Output cards
TSX AEZ 414
TSX AEZ 801
TSX AEZ 802
TSX ASZ 200
TSX ASZ 401
Number/Type of channels
8 DI
8 DI
12 DI
12 DI
32 DI
32 DI
32 DI
4 DO
16 DO
8 DO
8 DO
8 DI
8 DO
16 DI
12 DO
16 DI
12 DO
16 DI
12 DO
16 DI
12 DO
32 DI
32 DO
4 AI
8 AI
8 AI
2 AO
4 AO
Interfaces
Direct inputs/outputs
Order No.
7789307xxx
7789307xxx
7789312xxx
7789301xxx
7789314xxx
7789330xxx
7789314xxx
7789312xxx
7789308xxx
7789312xxx
7789301xxx
Quantity
1
1
1
1
1
1
1
1
1
1
1
7789834xxx
1
7789331xxx
1
7789331xxx
1
7789313xxx
1
7789301xxx
7789301xxx
7789301xxx
7789301xxx
7789309xxx
7789311xxx
7789311xxx
7789310xxx
7789310xxx
1
1
2
2
1
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
R1208
1
R1208
1
H2016
1
H2012
1
H2016
2
R3632
1
H2016
2
H2008
1
R2416
1
H2008
1
H2008
1
H2008
1
H2008
1
R2416
1
R2416
1
R2416
1
R2416
1
H2016
1
H2016
1
H2016
1
H2012
1
H2016
2
H2016
2
A1504
1
A2508
1
A2508
1
A1504
1
A1504
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
2
I2016
2
Insulated outputs
- see page A.70 Type
Quantity
O2008
1
O2008
O2008
1
1
O2008
1
O2016
1
O2012
1
O2016
2
A) Attention! Only use interfaces without LEDs
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.28
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC SCHNEIDER – PREMIUM
DI
DO
AI
AO
Note
PLC
Cables
Input/Output cards
Standard
Manufacturer code
TSX DEY 08D2
TSX DEY 16A2
TSX DEY 16A3
TSX DEY 16A4
TSX DEY 16A5
TSX DEY 16D2
TSX DEY 16D3
TSX DEY 16FK
TSX DEY 32D2K
TSX DEY 64D2K
TSX DSY 08R4D
TSX DSY 08R5
TSX DSY 08R5A
TSX DSY 08S5
TSX DSY 08T2
TSX DSY 08T22
TSX DSY 08T31
TSX DSY 16R5
TSX DSY 16S4
TSX DSY 16T2
TSX DSY 16T3 A)
TSX DSY 32T2K
TSX DSY 64T2K
TSX AEY 1600
TSZ AEY 414
TSX AEY 414
TSX AEY 420
TSX AEY 800
TSX AEY 810
TSX ASY 410
TSX ASY 410
TSX ASY 800
Number/Type of channels
8 DI
16 DI
16 DI
16 DI
16 DI
16 DI
16 DI
16 DI
32 DI
64 DI
8 DO
8 DO
8 DO
8 DO
8 DO
8 DO
8 DO
16 DO
16 DO
16 DO
16 DO
32 DO
64 DO
16 AI
4 AI, resistances applications
4 AI, current and voltage
applications
4 AI
8 AI
8 AI
4 AO, current applications
4 AO, voltage applications
8 AO
Interfaces
Direct inputs/outputs
- see page A.38 (H) or A.60 (A) Type
Quantity
H2008
1
R2416
1
R2416
1
R2416
1
R2416
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
4
R2416
1
R2416
1
R2416
1
R2416
1
H2008
1
R1208
1
R1208
1
R2416
1
R2416
1
H2016
1
H2016
1
H2016
2
H2016
4
A2508P
2
A2508P
1
Order No.
7789322xxx
7789315xxx
7789315xxx
7789315xxx
7789315xxx
7789322xxx
7789322xxx
7789301xxx
7789301xxx
7789301xxx
7789318xxx
7789316xxx
7789318xxx
7789316xxx
7789322xxx
7789317xxx
7789317xxx
7789316xxx
7789316xxx
7789322xxx
7789322xxx
7789301xxx
7789301xxx
7789259xxx
7789319xxx
Quantity
1
1
1
1
1
1
1
1
2
4
1
1
1
1
1
1
1
1
1
2
4
2
4
2
1
7789320xxx
1
A1504
1
7789259xxx
7789259xxx
7789261xxx
7789320xxx
7789321xxx
7789259xxx
1
1
1
1
1
1
A2508P
A2508P
A2508P
A1504
A1504
A2508P
1
1
1
1
1
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
I2016
I2016
I2016
I2016
Insulated outputs
- see page A.70 Type
Quantity
A
1
1
1
2
4
O2008
1
O2016
1
O2016
O2016
2
4
A) Attention! Only use interfaces without LEDs
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.29
Universal solutions for PLC input/
output cards
Selection guide
PLC SCHNEIDER – QUANTUM
A
DI
DO
DI/DO
140 DDM 390 00
140 AII 330 00
140 ARI 030 10
AO
Note
Cables
Standard
Manufacturer code
140 DAI 340 00
140 DAI 353 00
140 DAI 440 00
140 DAI 453 00
140 DAI 540 00
140 DAI 553 00
140 DAI 740 00
140 DDI 353 00
140 DDI 364 00
140 DDI 841 00
140 DDI 853 00
140 DAO 840 00
140 DAO 842 10
140 DDO 353 00
140 DDO 364 00
140 DDO 843 00
140 DRA 840 00
140 ACI 030 00
140 ACI 030 00
140 ACI 040 00
AI
PLC
Input/Output cards
140 AVI 030 00
140 AVI 030 00
140 ACO 020 00
140 ACO 130 00
140 AIO 330 00
Number/Type of channels
16 DI
32 DI
16 DI
32 DI
16 DI
32 DI
16 DI
32 DI
96 DI
16 DI
32 DI
16 DO
16 DO
32 DO
96 DO
16 DO
16 DO
16 DI
8 DO
8 AI, current applications
8 AI, voltage applications
16 AI
8 AI, 2-wire resistances
applications
8 AI, 2-wire resistances
applications
8 AI, current applications
8 AI, voltage applications
4 AO
8 AO, without monitoring
8 AIO
Order No.
7789118xxx
7789118xxx
7789118xxx
7789118xxx
7789118xxx
7789118xxx
7789118xxx
7789121xxx
7789301xxx
7789119xxx
7789121xxx
7789118xxx
7789113xxx
7789121xxx
7789301xxx
7789120xxx
7789118xxx
Interfaces
Direct inputs/outputs
Quantity
1
1
1
1
1
1
1
1
6
1
1
1
1
1
6
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
R3632
1
R3632
1
R3632
1
R3632
1
R3632
1
R3632
1
R3632
1
H2016
2
H2016
6
H2016
1
H2016
2
R3632
1
R2416
1
H2016
2
H2016
6
H2016
1
R3632
1
H2016
1
H2008
1
A2508
1
A2508
1
A3716
1
7789133xxx
1
7789125xxx
7789134xxx
7789123xxx
1
1
1
7789136xxx
1
A2508
1
7789135xxx
1
A2508
1
7789125xxx
7789134xxx
7789124xxx
7789126xxx
7789137xxx
1
1
1
1
1
A2508
A2508
A1504
A2508
A2508
1
1
1
1
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
I2016
I2016
I2016
Insulated outputs
- see page A.70 Type
Quantity
2
6
1
2
O2016
O2016
O2016
2
6
1
O2008
1
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.30
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC SCHNEIDER – TWIDO
DI
DO
TWD LMDA 20DRT C)
TWD LMDA 20DTK
TWD LMDA 20DUK D)
TWD LMDA 40DTK
TWD LMDA 40DUK D)
AI
AO
AI/AO
Note
Cables
Standard
Manufacturer code
TWD DDI 16DK
TWD DDI 16DT
TWD DDI 16DT A)
TWD DII 32DK
TWD DDI 8DT
TWD DDI 8DT A)
TWD DDO 16TK
TWD DDO 16UK B)
TWD DDO 32TK
TWD DDO 32UK B)
TWD DDO 8TT
TWD DDO 8UT A)
TWD DRA 16RT
TWD DRA 8RT
TWD LMDA 20DRT
DI/DO
PLC
Input/Output cards
TWD AMI 2HT
TWD AMO 1HT
TWD ALM 3LT
TWD AMM 3HT
Number/Type of channels
16 DI, positive logic
16 DI, positive logic
16 DI, negative logic
32 DI
8 DI, positive logic
8 DI, negative logic
16 DO
16 DO
32 DO
32 DO
8 DO
8 DO
16 DO
8 DO
12 DI, positive logic
8 DO
12 DI, negative logic
8 DO
12 DI, positive logic
8 DO
12 DI, positive logic
8 DO
24 DI, positive logic
16 DO
24 DI, positive logic
16 DO
2 AI
1 AI
2 AI
1 AO
2 AI
1 AO
Interfaces
Order No.
7789328xxx
7789100xxx
7789100xxx
7789328xxx
7789100xxx
7789100xxx
7789329xxx
7789328xxx
7789329xxx
7789328xxx
7789100xxx
7789100xxx
7789104xxx
7789108xxx
7789100xxx
7789104xxx
7789100xxx
7789104xxx
Quantity
1
1
1
2
1
1
1
1
2
2
1
1
1
1
1
7789327xxx
1
7789326xxx
1
7789327xxx
2
7789326xxx
2
7789250xxx
7789250xxx
1
1
7789250xxx
1
7789250xxx
1
1
Direct inputs/outputs
Insulated inputs
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
1
H2016
1
H2016
1
H2016
2
H2008
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
H2008
1
H2016
1
R2416
1
R1208
1
H2012
1
R2416
1
H2016
1
R2416
1
H2012
1
H2016
1
H2012
1
H2016
1
H2012
2
H2016
2
H2012
2
H2008
2
A1504
1
A1504
1
1
A1504
1
1
A1504
1
- see page A.66 Type
Quantity
I2016
1
I2016
1
I2016
I2016
Insulated outputs
- see page A.70 Type
Quantity
A
2
1
O2016
O2016
O2016
O2016
O2008
1
1
2
2
1
O2016
1
H2008
2
A) Attention! Only use interfaces without LEDs
B) A ttention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
C) Attention! Use only interfaces without LEDs for the direct input option
D) Attention! Use only interfaces without LEDs for the direct output option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated outlet option
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
•Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end.
These cables do not have a PLC connector. Colour code according to DIN 47100.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.31
Universal solutions for PLC input/
output cards
Selection guide
PLC SIEMENS – S7-200
A
DI
DO
PLC
Cables
Input/Output cards
Standard
Manufacturer code
6ES7221-1BF22-0XA0
6ES7221-1BH22-0XA0
6ES7221-1EF22-0XA0
6ES7222-1BD22-0XA0
6ES7222-1BF22-0XA0
6ES7222-1EF22-0XA0
6ES7222-1HD22-0XA0
6ES7223-1BF22-0AX0
6ES7223-1BH22-0XA0
6ES7223-1BL22-0XA0
DI/DO
6ES7223-1BM22-0XA0
6ES7223-1HF22-0XA0
6ES7223-1PH22-0XA0
6ES7223-1PL22-0XA0
6ES223-1PM22-0XA0
AI
AO
AI/AO
Note
6ES7231-0HC22-0XA0
6ES7231-0HF22-0XA0
6ES7232-0HB22-0XA0
6ES7232-0HD22-0XA0
6ES7235-0KD22-0XA0
Number/Type of channels
8 DI
16 DI
8 DI
4 DO
8 DO
8 DO
8 DO
4 DI
4 DO
8 DI
8 DO
16 DI
16 DO
32 DI
32 DO
4 DI
4 DO
8 DI
8 DO
16 DI
16 DO
32 DI
32 DO
4 AI
8 AI
2 AO
4 AO
4 AI / 1 AO
Interfaces
Direct inputs/outputs
Order No.
7789100xxx
7789100xxx
7789104xxx
7789100xxx
7789100xxx
7789104xxx
7789104xxx
Quantity
1
1
1
1
1
1
1
7789100xxx
2
7789100xxx
2
7789100xxx
2
7789100xxx
4
7789100xxx
7789108xxx
7789100xxx
7789108xxx
7789100xxx
7789104xxx
7789100xxx
7789104xxx
7789250xxx
7789252xxx
7789250xxx
7789250xxx
7789252xxx
1
1
1
1
1
1
2
2
1
1
1
1
1
- see page A.38 (H) or A.60 (A) Type
Quantity
H2008
1
H2016
1
R2416
1
H2008
1
H2008
1
R2416
1
R2416
1
H2008
1
H2008
1
H2008
1
H2008
1
H2016
1
H2016
1
H2016
2
H2016
2
H2008
1
R1208
1
H2008
1
R1208
1
H2016
1
R2416
1
H2016
2
R2416
2
A1504
1
A2508
1
A1504
1
A1504
1
A2508
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
Insulated outputs
- see page A.70 Type
Quantity
1
O2008
O2008
1
1
O2008
1
O2008
1
O2016
1
O2016
2
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
•Cables 7789100xxx, 7789104xxx, 7789106xxx, 7789108xxx, 7789250xxx, 7789252xxx and 7789254xxx have wire-end ferrules at one end.
These cables do not have a PLC connector. Colour code according to DIN 47100.
*
In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.32
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC SIEMENS – S7-300/ET- 200M
PLC
Cables
Input/Output cards
Standard
Manufacturer code
6ES7321-1BH00-0AA0
6ES7321-1BH01-0AA0
6ES7321-1BH02-0AA0
6ES7321-1BH50-0AA0
6ES7321-1BH80-0AA0
6ES7321-1BH81-0AA0
6ES7321-1BH82-0AA0
6ES7321-1BL00-0AA0
6ES7321-1BL80-0AA0
6ES7321-1BP00-0AA0
DI
DO
6ES7321-1CH20-0AA0
6ES7321-1CH80-0AA0
6ES7321-1EH00-0AA0
6ES7321-1EH01-0AA0
6ES7321-1EL00-0AA0
6ES7321-1FF00-0AA0
6ES7321-1FF01-0AA0
6ES7321-1FF81-0AA0
6ES7321-1FH00-0AA0
6ES7321-7BH00-0AB0 A)
6ES7321-7BH01-0AB0 A)
6ES7321-7BH80-0AB0 A)
6ES7321-7RD00-0AB0 B)
6ES7322-1BF00-0AA0
6ES7322-1BF01-0AA0
6ES7322-1BH00-0AA0
6ES7322-1BH01-0AA0
6ES7322-1BH10-0AA0
6ES7322-1BH81-0AA0
6ES7322-1BL00-0A00
6ES7322-1BP00-0AA0
6ES7322-1BP50-0AA0 C)
6ES7322-1CF00-0AA0
6ES7322-1CF80-0AA0
6ES7322-1EH00-0AA0
6ES7322-1EH01-0AA0
6ES7322-1EL00-0AA0
6ES7322-1FF00-0AA0
6ES7322-1FF01-0AA0
6ES7322-1FF81-0AA0
6ES7322-1FH00-0AA0
6ES7322-1FL00-0AA0
6ES7322-1HF80-0AA0
6ES7322-5RD00-0AB0 D)
6ES7322-5SD00-0AB0 D)
6ES7322-8BF00-0AB0
6ES7322-8BF00-0AB0
6ES7322-8BH01-0AB0
6ES7322-8BH01-0AB0
6ES7323-1BH00-0A00
6ES7323-1BH01-00A0
DI/DO
6ES7323-1BH80-0AA0
6ES7323-1BH80-0A00
6ES7323-1BL00-0AA0
1327330000 – 2012/2013
Number/Type of channels
16 DI
16 DI
16 DI
16 DI
16 DI
16 DI
16 DI
32 DI
32 DI
64 DI, positive logic
64 DI, negative logic A)
16 DI
16 DI
16 DI
16 DI
16 DI
8 DI
8 DI
8 DI
16 DI
16 DI
16 DI
16 DI
16 DI
8 DO
8 DO
16 DO
16 DO
16 DO
16 DO
32 DO
64 DO
64 DO
8 DO
8 DO
16 DO
16 DO
32 DO
8 DO
8 DO
8 DO
16 DO
32 DO
8 DO
4 DO
4 DO
8 DO, without redundancy
8 DO, with redundancy
16 DO, without redundancy
16 DO, with redundancy
8 DI
8DO
8 DI
8 DO
8 DI
8 DO
8 DI
8 DO
16 DI
16 DO
Interfaces
Order No.
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789236xxx
7789236xxx
7789771xxx
7789768xxx
7789211xxx
7789211xxx
7789212xxx
7789212xxx
7789215xxx
7789219xxx
7789219xxx
7789219xxx
7789212xxx
7789210xxx
7789210xxx
7789210xxx
7789801xxx
7789239xxx
7789239xxx
7789234xxx
7789234xxx
7789234xxx
7789234xxx
7789236xxx
7789246xxx
7789246xxx
7789191xxx
7789191xxx
7789211xxx
7789211xxx
7789211xxx
7789219xxx
7789219xxx
7789219xxx
7789211xxx
7789211xxx
7789190xxx
7789192xxx
7789192xxx
7789239xxx
7789830xxx
7789729xxx
7789730xxx
Quantity
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
2
1
1
1
1
2
1
1
1
1
1
1
1
7789237xxx
1
7789237xxx
1
7789237xxx
1
7789237xxx
1
7789236xxx
1
Direct inputs/outputs
Insulated inputs
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
2
H2016
4
H2016
4
R2416
1
R2416
1
R2416
1
R2416
1
R3632
1
R1208
1
R1208
1
R1208
1
R2416
1
R2416
1
R2416
1
R2416
1
H20
1
H2008
1
H2008
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
2
H2016
4
H2016
4
R1208
1
R1208
1
R2416
1
R2416
1
R2416
2
R1208
1
R1208
1
R1208
1
R2416
1
R2416
2
R2416
1
H2016
1
H2016
1
H2008
1
H2008
1
H2016
1
H2016
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2008
1
H2016
1
H2016
1
- see page A.66 Type
Quantity
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
2
I2016
2
I2016
4
I2016
Insulated outputs
- see page A.70 Type
Quantity
O2008
O2008
O2016
O2016
O2016
O2016
O2016
O2016
O2016
1
1
1
1
1
1
2
4
4
O2008
O2008
O2016
O2016
1
1
1
1
O2008
1
O2008
1
O2008
1
O2008
1
O2016
1
A
1
A.33
Universal solutions for PLC input/
output cards
Selection guide
PLC SIEMENS – Siemens S7-300 / ET- 200M
A
AI
AO
AI/AO
PLC
Cables
Input/Output cards
Standard
Manufacturer code
6ES7331-1KF01-0AB0
6ES7331-1KF02-0AB0
6ES7331-7KB00-0AB0
6ES7331-7KB01-0AB0
6ES7331-7KB02-0AB0
6ES7331-7KF00-0AB0
6ES7331-7KF01-0AB0
6ES7331-7KF02-0AB0
6ES7331-7NF00-0AB0
6ES7331-7PF00-0AB0
6ES7331-7PF00-0AB0 E)
6ES7331-7PF01-0AB0
6ES7331-7PF01-0AB0 E)
6ES7331-7RD00-0AB0
6ES7331-7RD00-0AB0
6ES7331-7TF01-0AB0
6ES7331-7TF01-0AB0
6ES7332-5HB00-0AB0
6ES7332-5HB00-0AB0 B)
6ES7332-5HB00-0AB0
6ES7332-5HB01-0AB0
6ES7332-5HB01-0AB0 B)
6ES7332-5HB01-0AB0
6ES7332-5HB81-0AB0
6ES7332-5HB81-0AB0 B)
6ES7332-5HB81-0AB0
6ES7332-5HD00-0AB0
6ES7332-5HD00-0AB0 B)
6ES7332-5HD00-0AB0
6ES7332-5HD01-0AB0
6ES7332-5HD01-0AB0 B)
6ES7332-5HD01-0AB0
6ES7332-5HF00-0AB0
6ES7332-5HF00-0AB0 B)
6ES7332-5RD00-0AB0
6ES7332-7ND01-0AB0
6ES7332-7ND01-0AB0 B)
6ES7332-7ND01-0AB0
6ES7332-7ND02-0AB0
6ES7332-7ND02-0AB0 B)
6ES7332-7ND02-0AB0
6ES7334-0CE01-0AA0
6ES7334-0KE00-0AB0
6ES7335-7HG01-0AB0
6ES7335-7HG02-0AB0
6ES7312-5BD00-0AB0
6ES7312-5BD01-0AB0
6ES7312-5BE03-0AB0
CPU
6ES7313-5BE00-0AB0
6ES7313-5BE01-0AB0
A.34
Number/Type of channels
8 AI
8 AI
2 AI
2 AI
2 AI
8AI
8 AI
8 AI
8 AI
8 AI, 2-wire applications
8 AI, 3 and 4-wire applications
8 AI, 2-wire applications
8 AI, 3 and 4-wire applications
4 AI, 2-wire applications
4 AI, 4-wire applications
8 AI, 2-wire applications
8 AI, 4-wire applications
2 AO, 2-wire voltage applications
2 AO, 4-wire voltage applications
2 AO, current applications
2 AO, 2-wire voltage applications
2 AO, 4-wire voltage applications
2 AO, current applications
2 AO, 2-wire voltage applications
2 AO, 4-wire voltage applications
2 AO, current applications
4 AO, 2-wire voltage applications
4 AO, 4-wire voltage applications
4 AO, current applications
4 AO, 2-wire voltage applications
4 AO, 4-wire voltage applications
4 AO, current applications
8 AO, voltage applications
8 AO, current applications
4 AO
4 AO, 2-wire voltage applications
4 AO, 4-wire voltage applications
4 AO, current applications
4 AO, 2-wire voltage applications
4 AO, 4-wire voltage applications
4 AO, current applications
4 AI + 2 AO
4 AI + 2 AO
4 AI + 2 AO
4 AI + 2 AO
10 DI
6 DO
10 DI
6 DO
10 DI
6 DO
16 DI
16 DO
8 DI
5 AI + 2 AO
16 DI
16 DO
8 DI
5 AI + 2 AO
Interfaces
Direct inputs/outputs
Order No.
7789604xxx
7789604xxx
7789224xxx
7789224xxx
7789224xxx
7789229xxx
7789229xxx
7789229xxx
7789231xxx
7789230xxx
7789759xxx
7789230xxx
7789759xxx
7789193xxx
7789194xxx
7789229xxx
7789800xxx
7789228xxx
7789801xxx
7789227xxx
7789228xxx
7789801xxx
7789227xxx
7789228xxx
7789801xxx
7789227xxx
7789228xxx
7789801xxx
7789227xxx
7789228xxx
7789801xxx
7789227xxx
7789759xxx
7789233xxx
7789195xxx
7789228xxx
7789801xxx
7789227xxx
7789228xxx
7789801xxx
7789227xxx
7789225xxx
7789196xxx
7789226xxx
7789226xxx
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7789221xxx
1
7789221xxx
1
7789221xxx
1
7789222xxx
1
7789223xxx
1
7789222xxx
1
7789223xxx
1
- see page A.38 (H) or A.60 (A) Type
Quantity
A3716
1
A3716
1
A1504
1
A1504
1
A1504
1
A2508
1
A2508
1
A2508
1
A3716
1
A2508
1
H40
1
A2508
1
H40
1
A1504
1
A2508
1
A2508
1
A2508
1
A1504
1
H20
1
A1504
1
A1504
1
H20
1
A1504
1
A1504
1
H20
1
A1504
1
A1504
1
H20
1
A1504
1
A1504
1
H20
1
A1504
1
H40
1
A2508
1
A1504
1
A1504
1
H20
1
A1504
1
A1504
1
H20
1
A1504
1
A3716
1
A2508
1
A3716
1
A3716
1
H2012
1
H2008
1
H2012
1
H2008
1
H2012
1
H2008
1
H2016
1
H2016
1
H2008
1
A2508P
1
H2016
1
H2016
1
H2008
1
A2508P
1
Insulated inputs
- see page A.66 Type
Quantity
I2016
Insulated outputs
- see page A.70 Type
Quantity
O2008
1
O2008
1
O2008
1
O2016
1
O2016
1
1
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC Siemens S7-300 / ET- 200M
PLC
Cables
Input/Output cards
Standard
Manufacturer code
6ES7313-5BF03-0AB0
6ES7313-6BE00-0AB0
6ES7313-6BE01-0AB0
6ES7313-6BF03-0AB0
6ES7313-6CE00-0AB0
6ES7313-6CE01-0AB0
6ES7313-6CF03-0AB0
6ES7314-6BF00-0AB0
CPU
6ES7314-6BF01-0AB0
6ES7314-6BF02-0AB0
6ES7314-6CF00-0AB0
6ES7314-6CF01-0AB0
6ES7314-6CF02-0AB0
Note
Number/Type of channels
16 DI
16 DO
8 DI
5 AI + 2 AO
16 DI
16 DO
16 DI
16 DO
16 DI
16 DO
16 DI
16 DO
16 DI
16 DO
16 DI
16 DO
16 DI
16 DO
8 DI
5 AI + 2 AO
16 DI
16 DO
8 DI
5 AI + 2 AO
16 DI
16 DO
8 DI
5 AI + 2 AO
16 DI
16 DO
8 DI
5 AI + 2 AO
16 DI
16 DO
8 DI
5 AI + 2 AO
16 DI
16 DO
8 DI
5 AI + 2 AO
Interfaces
Order No.
Quantity
7789222xxx
1
7789223xxx
1
7789222xxx
1
7789222xxx
1
7789222xxx
1
7789222xxx
1
7789222xxx
1
7789222xxx
1
7789222xxx
1
7789223xxx
1
7789222xxx
1
7789223xxx
1
7789222xxx
1
7789223xxx
1
7789222xxx
1
7789223xxx
1
7789222xxx
1
7789223xxx
1
7789222xxx
1
7789223xxx
1
Direct inputs/outputs
Insulated inputs
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
1
H2016
1
H2008
1
A2508P
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2016
1
H2008
1
A2508P
1
H2016
1
H2016
1
H2008
1
A2508P
1
H2016
1
H2016
1
H2008
1
A2508P
1
H2016
1
H2016
1
H2008
1
A2508P
1
H2016
1
H2016
1
H2008
1
A2508P
1
H2016
1
H2016
1
H2008
1
A2508P
1
- see page A.66 Type
Quantity
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
1
I2016
I2016
I2016
I2016
I2016
Insulated outputs
- see page A.70 Type
Quantity
O2016
1
O2016
1
O2016
1
O2016
1
O2016
1
O2016
1
O2016
1
O2016
1
O2016
1
O2016
1
O2016
1
O2016
1
O2016
1
A
1
1
1
1
1
A) Attention! Only use interfaces without LEDs
B) Attention! Only use these interfaces: 8537110000 or 0224261001. More information in chapter C
C) Attention! Use only interfaces without LEDs for the direct option. Only use these interfaces, 1129100000, 1129110000, 1129120000 or 1129130000 for the insulated option
D) This is not an ATEX solution. The interface cannot have LEDs, fuses, disconnectors or test points
E) Attention! Only use these interfaces: 8537140000 or 0224461001. More information in chapter C
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.35
Universal solutions for PLC input/
output cards
Selection guide
PLC SIEMENS – S7-400
A
DI
DO
AI
Note
AO
PLC
Cables
Input/Output cards
Standard
Manufacturer code
6ES7421-1BL00-0AA0
6ES7421-1BL01-0AA0
6ES7421-1EL00-0AA0
6ES7421-1FH00-0AA0
6ES7421-1FH20-0AA0
6ES7421-7BH00-0AB0
6ES7421-7BH01-0AB0
6ES7421-7DH00-0AB0
6ES7422-1BH10-0AA0
6ES7422-1BH11-0AA0
6ES7422-1BL00-0AA0
6ES7422-1FF00-0AA0
6ES7422-1FH00-0AA0
6ES7422-1HH00-0AA0
6ES7422-5EH10-0AB0
6ES7422-7BL00-0AB0
6ES7431-0HH00-0AB0
6ES7431-1KF00-0AB0
6ES7431-1KF00-0AB0
6ES7431-1KF10-0AB0
6ES7431-1KF20-0AB0
6ES7431-7KF10-0AB0
6ES7431-7QH00-0AB0
6ES7432-1HF00-0AB0
Number/Type of channels
32 DI
32 DI
32 DI
16 DI
16 DI
16 DI
16 DI
16 DI
16 DO
16 DO
32 DO
8 DO
16 DO
16 DO
16 DO
32 DO
16 AI
8 AI, voltage and resistance applications
8 AI, current applications
8 AI
8 AI
16 AI
16 AI
8 AO, 8 AO, common mode voltage applications
Order No.
7789292xxx
7789292xxx
7789278xxx
7789273xxx
7789273xxx
7789290xxx
7789290xxx
7789278xxx
7789291xxx
7789291xxx
7789292xxx
7789283xxx
7789273xxx
7789270xxx
7789291xxx
7789292xxx
7789284xxx
7789286xxx
7789287xxx
7789285xxx
7789285xxx
7789284xxx
7789284xxx
7789288xxx
Interfaces
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Direct inputs/outputs
Insulated inputs
- see page A.38 (H) or A.60 (A) Type
Quantity
H2016
2
H2016
2
R3632
1
R2416
1
R2416
1
H2016
2
H2016
2
R3632
1
H2016
1
H2016
1
H2016
2
R1208
1
R2416
1
R3632
1
H2016
1
H2016
2
A3716
1
A2508
1
A2508
1
A2508
1
A2508
1
A3716
1
A3716
1
A2508
1
- see page A.66 Type
Quantity
H2016
2
H2016
2
H2016
H2016
Insulated outputs
- see page A.70 Type
Quantity
2
2
O2016
O2016
O2016
1
1
2
O2016
O2016
1
2
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
* In
the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
A.36
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
Selection guide
PLC SIEMENS – S7-1200
DI
DO
PLC
Cables
Input/Output cards
Standard
Manufacturer code
6ES7221-1BF30-0XB0
6ES7221-1BH30-0XB0
6ES7222-1HF30-0XB0
6ES7222-1HH30-0XB0
6ES7222-1BF30-0XB0
6ES7222-1BH30-0XB0
6ES7223-1PH30-0XB0
DI/DO
6ES7223-1PL30-0XB0
6ES7223-1BH30-0XB0
6ES7223-1BL30-0XB0
AI
AO
AI/AO
6ES7231-4HD30-0XB0
6ES7231-4HF30-0XB0
6ES7232-4HB30-0XB0
6ES7232-4HD30-0XB0
6ES7234-4HE30-0XB0
Note
Number/Type of channels
8 DI
16 DI
8 DO
16 DO
8 DO
16 DO
8 DI
8 DO
16 DI
16 DO
8 DI
8 DO
16 DI
16 DO
4 AI
8 AI
2 AO
4 AO
4 AI
2 AO
Interfaces
Direct inputs/outputs
Order No.
1329110xxx
1329120xxx
1329130xxx
1329140xxx
1329150xxx
1329170xxx
1329180xxx
1329190xxx
1329200xxx
1329210xxx
1329180xxx
1329230xxx
1329200xxx
1329240xxx
1329250xxx
1329270xxx
1329280xxx
1329290xxx
Quantity
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1329300xxx
1
- see page A.38 (H) or A.60 (A) Type
Quantity
H2008
1
H2016
1
R1208
1
R2416
1
H2008
1
H2016
1
H2008
1
R1208
1
H2016
1
R2416
1
H2008
1
H2008
1
H2016
1
H2016
1
A1504
1
A2508
1
A1504
1
A1504
1
A2508
Insulated inputs
- see page A.66 Type
Quantity
Insulated outputs
- see page A.70 Type
Quantity
A
H2016
O2008
O2016
1
1
O2008
1
O2016
1
1
•Please, always take into account the characteristics of the PLC card (voltage, current…) when selecting interfaces. In some cases, the card can work at
higher voltages than those indicated in the interface.
•The last 3 digits of the cable code indicate its length in decimetres. For example, if the code ends in 100, the cable would be 10 m long.
*In the case that an input/output card does not appear in this table, you can check our on-line PLC selection guide at www.weidmueller.com where you will
always find the most up-to-date information.
1327330000 – 2012/2013
A.37
Universal solutions for PLC input/
output cards
Selection guide
A
RS IO – Selection guide for passive interfaces
for digital signals
Type
Family
Type of wiring
8-channel
H2008
R1208
2-wire
2-wire
12-channel
H2012
2-wire
Number of
channels
Connection
Screw
Tension clamp
connection
L
9445630000
RS 12IO 2W L H S
A.42
V
V
L
9445700000
9445710000
1311750000
1311770000
9445810000
1311780000
9445720000
9445730000
1311790000
1311800000
1311810000
9445750000
1311820000
1311830000
9445820000
1311850000
1311840000
1311870000
9445760000
9445770000
1311880000
1311890000
9441500000
9441860000
9441700000
9441560000
9441600000
RS 16IO 1W H S
RS 16IO 1W L H S
RS 16IO 1W H Z
RS 16IO 1W L H Z
RS 16IO 1W I-L H S
RS 16IO 1W I-L H Z
RS 16IO 2W H S
RS 16IO 2W L H S
RS 16IO 2W H Z
RS 16IO 2W L H Z
RS 16IO 2W I H S
RS 16IO 2W I-L H S
RS 16IO 2W I H Z
RS 16IO 2W I-L H Z
RS 16IO 2W F H S
RS 16IO 2W F-L H S
RS 16IO 2W F H Z
RS 16IO 2W F-L H Z
RS 16IO 3W H S
RS 16IO 3W L H S
RS 16IO 3W H Z
RS 16IO 3W L H Z
RS 16IO 1W R S
RS 16IO 1W I R S
RS 16IO 2W R S
RS 16IO 2W F R S
RS 16IO 3W I R S
A.43
A.43
A.43
A.43
A.44
A.44
A.45
A.45
A.45
A.45
A.46
A.46
A.46
A.46
A.47
A.47
A.47
A.47
A.48
A.48
A.48
A.48
A.49
A.49
A.50
A.50
A.51
9445900000
9445910000
9445870000
9445930000
9445950000
9445980000
9445960000
9445970000
9441510000
9441870000
9441710000
9441570000
9441610000
RS 32IO 1W H S
RS 32IO 1W L H S
RS 32IO 1W I-L H S
RS 32IO 2W L H S
RS 32IO 2W I-L H S
RS 32IO 2W F H S
RS 32IO 3W H S
RS 32IO 3W L H S
RS 32IO 1W R S
RS 32IO 1W I R S
RS 32IO 2W R S
RS 32IO 2W F R S
RS 32IO 3W I R S
A.52
A.52
A.53
A.54
A.54
A.55
A.56
A.56
A.57
A.57
A.58
A.58
A.59
Z
Z
V
V
Z
Z
H2032
32-channel
2-wire
3-wire
1-wire
R3632
A.38
2-wire
3-wire
L
I
I
I
I
F
F
F
F
L
V
V
L
L
Z
Z
L
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
I
I
L
L
Z
Z
1-wire
L
L
L
L
V
V
3-wire
Page
V
16-channel
2-wire
Interfaces
A.40
A.41
Z
Z
R2416
Type
RS 8IO 2W L H S
RS 8IO 2W R S
V
V
1-wire
Order No.
9445530000
9441540000
Z
3-wire
Fuse
L
V
2-wire
Disconnectable
V
V
1-wire
H2016
Features
LED by channel
I
F
I
L
L
L
L
I
I
F
L
I
F
I
Note 1:
Coding of the interface descriptions RS 8IO: 8 inputs/outputs
1W:1-wire
12IO: 12 inputs/outputs
2W:2-wire
16IO: 16 inputs/outputs
3W:3-wire
32IO: 32 inputs/outputs
Number of wires
Note 2:
2 units of the following products from the
H2016 family can be replaced by 1 unit
from the H2032 family
9445700000
9445710000
9445810000
9445730000
9445750000
9445820000
9445760000
9445770000
RS 16IO 1W H S
RS 16IO 1W L H S
RS 16IO 1W I-L H S
RS 16IO 2W L H S
RS 16IO 2W I-L H S
RS 16IO 2W F H S
RS 16IO 3W H S
RS 16IO 3W L H S
2 units
2 units
2 units
2 units
2 units
2 units
2 units
2 units
(empty): Direct
H HE connector (ribbon cable) S: Screw
I: Switch
R: RSV connector
Z: Tension clamp connection
L: LED
F: Fuse
I-L Switch + LED
F-L: Fuse + LED
9445900000
9445910000
9445870000
9445930000
9445950000
9445980000
9445960000
9445970000
RS 32IO 1W H S
RS 32IO 1W L H S
RS 32IO 1W I-L H S
RS 32IO 2W L H S
RS 32IO 2W I-L H S
RS 32IO 2W F H S
RS 32IO 3W H S
RS 32IO 3W L H S
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1327330000 – 2012/2013
A
1327330000 – 2012/2013
A.39
Universal solutions for PLC input/
output cards
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
A
RS IO - Interface
for 8 digital signals 2-wire H (HE connector)
system
RS 8IO 2W L H
H system, 2 wires with LED
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
green
yellow
No
3.15 A
No
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
74 mm / 87 mm
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
The common C may carry up to 3 A if the external jumpers are not used
Ordering data
Screw connection with LED
Type
RS 8IO 2W L H S
Height
72 mm
Order No.
9445530000
Note
Accessories
Note
A.40
1327330000 – 2012/2013
RS IO - Interface
for 8 digital signals 2-wire R system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS 8IO 2W R
R system, 2 wires
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Connector RSV 1.6
12-pole socket
No
No
No
3.15 A
No
250 V UC
1A
24 V DC ± 10%
3A
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 250 V AC
II
2
2.1 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
68 mm / 87 mm
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
The common C may carry up to 3 A if the external jumpers are not used
Ordering data
Screw connection without LED
Type
RS 8IO 2W R S
Height
72 mm
Order No.
9441540000
Note
Accessories
Note
1327330000 – 2012/2013
A.41
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS IO - Interface
for 12 digital signals 2-wire H system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 12IO 2W L H
H system, 2 wires with LED
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
green
yellow
No
3.15 A
No
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
95 mm / 87 mm
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
The common C may carry up to 3 A if the external jumpers are not used
Ordering data
Screw connection with LED
Type
RS 12IO 2W L H S
Height
72 mm
Order No.
9445630000
Note
Accessories
Note
A.42
1327330000 – 2012/2013
RS IO - Interface
for 16 digital signals 1-wire H system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 16IO 1W H
RS 16IO 1W L H
H system, 1 wire
H system, 1 wire with LED
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
No
yellow
No
3.15 A
No
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
green
yellow
No
3.15 A
No
25 V AC / 50 V DC
1A
24 V DC ± 10%
2A
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE; GOSTME25
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
46 mm / 87 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
46 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
46 mm / 87 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
46 mm / 87 mm
Ordering data
Screw connection without LED
Screw connection with LED
Tension-clamp connection without LED
Tension-clamp connection with LED
Note
Type
RS 16IO 1W H S
Height
72 mm
Order No.
9445700000
RS 16IO 1W H Z
72 mm
1311750000
Type
Height
Order No.
RS 16IO 1W L H S
72 mm
9445710000
RS 16IO 1W L H Z
72 mm
1311770000
Accessories
Note
1327330000 – 2012/2013
A.43
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS IO - Interface
for 16 digital signals 1-wire H system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 16IO 1W I-L H
H system, 1 wire with LED and disconnection per channel
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
green
yellow
No
3.15 A
No
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
110 mm / 87 mm
Tension clamp connection
0.14 mm² / 1.5 mm²
0.14 mm² / 1.5 mm²
TS 32, TS 35
110 mm / 87 mm
Ordering data
Screw connection without LED
Screw connection with LED
Tension-clamp connection without LED
Tension-clamp connection with LED
Note
Type
Height
Order No.
RS 16IO 1W I-L H S
72 mm
9445810000
RS 16IO 1W I-L H Z
72 mm
1311780000
Accessories
Note
A.44
1327330000 – 2012/2013
RS IO - Interface
for 16 digital signals 2-wire H system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 16IO 2W H
RS 16IO 2W L H
H system, 2 wires
H system, 2 wires with LED
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
No
yellow
No
3.15 A
No
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
green
yellow
No
3.15 A
No
25 V AC / 50 V DC
1A
24 V DC ± 10%
2A
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE; GOSTME25
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
87 mm / 87 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
87 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
87 mm / 87 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
87 mm / 87 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 16IO 2W H S
Height
72 mm
Order No.
9445720000
Type
Height
Order No.
72 mm
72 mm
1311790000
RS 16IO 2W L H S
RS 16IO 2W H Z
9445730000
RS 16IO 2W L H Z
72 mm
1311800000
Ordering data
Screw connection without LED
Screw connection with LED
Tension-clamp connection without LED
Tension-clamp connection with LED
Note
Accessories
Note
1327330000 – 2012/2013
A.45
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS IO - Interface
for 16 digital signals 2-wire H system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 16IO 2W I H
RS 16IO 2W I L H
H system, 2 wires with disconnection per channel
H system, 2 wires with LED and disconnection per channel
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
No
yellow
No
3.15 A
No
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
green
yellow
No
3.15 A
No
25 V AC / 50 V DC
1A
24 V DC ± 10%
2A
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
95 mm / 87 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
95 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
95 mm / 87 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
95 mm / 87 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 16IO 2W I H S
Height
72 mm
Order No.
1311810000
Type
Height
Order No.
72 mm
72 mm
1311820000
RS 16IO 2W I-L H S
RS 16IO 2W I H Z
9445750000
RS 16IO 2W I-L H Z
72 mm
1311830000
Ordering data
Screw connection without LED
Screw connection with LED
Tension-clamp connection without LED
Tension-clamp connection with LED
Note
Accessories
Note
A.46
1327330000 – 2012/2013
RS IO - Interface
for 16 digital signals 2-wire H system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 16IO 2W F H
RS 16IO 2W F-L H
H system, 2 wires with fuse per channel
H system, 2 wires with LED and fuse per channel
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
No
yellow
500 mA
3.15 A
No
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
green
yellow
500 mA
3.15 A
No
25 V AC / 50 V DC
1A
24 V DC ± 10%
2A
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
-25...+50°C
-40...+60 °C
CE
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
122 mm / 87 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
122 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
122 mm / 87 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
122 mm / 87 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 16IO 2W F H S
Height
72 mm
Order No.
9445820000
Type
Height
Order No.
72 mm
72 mm
1311840000
RS 16IO 2W F-L H S
RS 16IO 2W F H Z
1311850000
RS 16IO 2W F-L H Z
72 mm
1311870000
Ordering data
Screw connection without LED
Screw connection with LED
Tension-clamp connection without LED
Tension-clamp connection with LED
Note
Accessories
Note
1327330000 – 2012/2013
A.47
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS IO - Interface
for 16 digital signals 3-wire H system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 16IO 3W H
RS 16IO 3W L H
H system, 3 wires
H system, 3 wires with LED
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
No
yellow
No
3.15 A
No
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
green
yellow
No
3.15 A
No
25 V AC / 50 V DC
1A
24 V DC ± 10%
2A
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE; GOSTME25
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
90 mm / 87 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
90 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
90 mm / 87 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
90 mm / 87 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 16IO 3W H S
Height
72 mm
Order No.
9445760000
Type
Height
Order No.
72 mm
72 mm
1311880000
RS 16IO 3W L H S
RS 16IO 3W H Z
9445770000
RS 16IO 3W L H Z
72 mm
1311890000
Ordering data
Screw connection without LED
Screw connection with LED
Tension-clamp connection without LED
Tension-clamp connection with LED
Note
Accessories
Note
A.48
1327330000 – 2012/2013
RS IO - Interface
for 16 digital signals 1-wire R system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 16IO 1W R
RS 16IO 1W I R
R system, 1 wire
R system, 1 wire with disconnection per channel
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Connector RSV 1.6
24-pole female
No
No
No
No
No
Connector RSV 1.6
24-pole female
No
No
No
3.15 A
No
150 V UC
1A
24 V DC ± 10%
3A
250 V UC
1A
24 V DC ± 10%
3A
-25...+50°C
-40...+60 °C
CE; GOSTME25
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 150 V AC
II
2
1.5 kV
< 250 V AC
II
2
2.1 kV
Screw connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
97 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
127 mm / 87 mm
Ordering data
Screw connection without LED
Type
RS 16IO 1W R S
Height
68 mm
Order No.
9441500000
Type
RS 16IO 1W I R S
Height
72 mm
Order No.
9441860000
Note
Accessories
Note
1327330000 – 2012/2013
A.49
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS IO - Interface
for 16 digital signals 2-wire R system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 16IO 2W R
RS 16IO 2W F R
R system, 2 wires
R system, 2 wires with fuse per channel
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Rated voltage (text)
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Connector RSV 1.6
24-pole female
No
No
No
3.15 A
No
Connector RSV 1.6
24-pole female
No
No
1A
3.15 A
No
150 V UC
1A
24 V DC ± 10%
3A
150 V UC
1A
24 V DC ± 10%
3A
-25...+50°C
-40...+60 °C
CE; GOSTME25
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 150 V AC
II
2
1.5 kV
< 150 V AC
II
2
1.5 kV
Screw connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
123 mm / 87 mm
Screw connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
123 mm / 109 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 16IO 2W R S
Type
RS 16IO 2W F R S
Ordering data
Screw connection without LED
Height
72 mm
Order No.
9441700000
Height
72 mm
Order No.
9441560000
Note
Accessories
Note
A.50
1327330000 – 2012/2013
RS IO - Interface
for 16 digital signals 3-wire R system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS 16IO 3W I R
R system, 3 wires with disconnection per channel
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Connector RSV 1.6
24-pole female
No
No
No
3.15 A
No
250 V UC
1A
24 V DC ± 10%
3A
-25...+50°C
-40...+60 °C
CE; GOSTME25
250 V AC
II
2
2.1 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
116 mm / 109 mm
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
The common C may carry up to 3 A if the external jumpers are not used
Ordering data
Screw connection without LED
Type
RS 16IO 3W I R S
Height
84 mm
Order No.
9441600000
Note
Accessories
Note
1327330000 – 2012/2013
A.51
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS IO - Interface
for 32 digital signals 1-wire H system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 32IO 1W H
RS 32IO 1W L H
H system, 1 wire
H system, 1 wire with LED
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
2x Plug-in connector acc. IEC 603-1 / DIN 41651
2x20-pole plug
No
yellow
No
3.15 A
No
2x Plug-in connector acc. IEC 603-1 / DIN 41651
2x20-pole plug
green
yellow
No
3.15 A
No
25 V AC / 50 V DC
1A
24 V DC ± 10%
2A
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE
-25...+50°C
-40...+60 °C
CE
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
90 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
90 mm / 87 mm
Ordering data
Screw connection without LED
Screw connection with LED
Type
RS 32IO 1W H S
Height
72 mm
Order No.
9445900000
Type
Height
Order No.
RS 32IO 1W L H S
72 mm
9445910000
Note
Accessories
Note
A.52
1327330000 – 2012/2013
RS 32IO 1W I-L H
H system, 1 wire with LED and disconnection per channel
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
A
2x Plug-in connector acc. IEC 603-1 / DIN 41651
2x20-pole plug
green
yellow
No
3.15 A
No
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
220 mm / 87 mm
Type
Height
Order No.
RS 32IO 1W I-L H S
72 mm
9445870000
1327330000 – 2012/2013
A.53
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS IO - Interface
for 32 digital signals 2-wire H system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 32IO 2W L H
RS 32IO 2W I-L H
H system, 2 wires with LED
H system, 2 wires with LED and disconnection per channel
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
2x Plug-in connector acc. IEC 603-1 / DIN 41651
2x20-pole plug
green
yellow
No
3.15 A
No
2x Plug-in connector acc. IEC 603-1 / DIN 41651
2x20-pole plug
green
yellow
No
3.15 A
No
24 V DC ± 10%
1A
24 V DC ± 10%
2A
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE
-25...+50°C
-40...+60 °C
CE
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
170 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
170 mm / 87 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
Height
Order No.
Type
Height
Order No.
RS 32IO 2W L H S
72 mm
9445930000
RS 32IO 2W I-L H S
72 mm
9445950000
Ordering data
Screw connection without LED
Screw connection with LED
Note
Accessories
Note
A.54
1327330000 – 2012/2013
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS 32IO 2W F H
H system, 2 wires with fuse per channel
A
2x Plug-in connector acc. IEC 603-1 / DIN 41651
2x20-pole plug
No
yellow
500 mA
3.15 A
No
25 V AC / 50 V DC
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
248 mm / 87 mm
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 32IO 2W F H S
1327330000 – 2012/2013
Height
72 mm
Order No.
9445980000
A.55
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS IO - Interface
for 32 digital signals 3-wire H system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 32IO 3W H
RS 32IO 3W L H
H system, 3 wires
H system, 3 wires with LED
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
2x Plug-in connector acc. IEC 603-1 / DIN 41651
2x20-pole plug
No
yellow
No
3.15 A
No
2x Plug-in connector acc. IEC 603-1 / DIN 41651
2x20-pole plug
green
yellow
No
3.15 A
No
25 V AC / 50 V DC
1A
24 V DC ± 10%
2A
24 V DC ± 10%
1A
24 V DC ± 10%
2A
-25...+50°C
-40...+60 °C
CE
-25...+50°C
-40...+60 °C
CE
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
176 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
176 mm / 87 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 32IO 3W H S
Type
Height
Order No.
RS 32IO 3W L H S
72 mm
9445970000
Ordering data
Screw connection without LED
Screw connection with LED
Height
72 mm
Order No.
9445960000
Note
Accessories
Note
A.56
1327330000 – 2012/2013
RS IO - Interface
for 32 digital signals 1-wire R system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 32IO 1W R
RS 32IO 1W I R
R system, 1 wire
R system, 1 wire with disconnection per channel
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Connector RSV 1.6
36-pole female
No
No
No
No
No
Connector RSV 1.6
36-pole female
No
No
No
3.15 A
No
150 V UC
1A
24 V DC ± 10%
3A
250 V UC
1A
24 V DC ± 10%
3A
-25...+50°C
-40...+60 °C
CE
-25...+50°C
-40...+60 °C
CE
< 150 V AC
II
2
1.5 kV
< 250 V AC
II
2
2.1 kV
Screw connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
148 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
188 mm / 87 mm
Ordering data
Screw connection without LED
Type
RS 32IO 1W R S
Height
72 mm
Order No.
9441510000
Type
RS 32IO 1W I R S
Height
72 mm
Order No.
9441870000
Note
Accessories
Note
1327330000 – 2012/2013
A.57
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS IO - Interface
for 32 digital signals 2-wire R system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
RS 32IO 2W R
RS 32IO 2W F R
R system, 2 wires
R system, 2 wires with fuse per channel
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Connector RSV 1.6
36-pole female
No
No
No
3.15 A
No
Connector RSV 1.6
36-pole female
No
No
2A
3.15 A
No
150 V UC
1A
24 V DC ± 10%
3A
150 V UC
1A
24 V DC ± 10%
3A
-25...+50°C
-40...+60 °C
CE
-25...+50°C
-40...+60 °C
CE
< 150 V AC
II
2
1.5 kV
< 150 V AC
II
2
1.5 kV
Screw connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
200 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
200 mm / 109 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 32IO 2W R S
Type
RS 32IO 2W F R S
Ordering data
Screw connection without LED
Height
72 mm
Order No.
9441710000
Height
84 mm
Order No.
9441570000
Note
Accessories
Note
A.58
1327330000 – 2012/2013
RS IO - Interface
for 32 digital signals 3-wire R system
Digital input/output passive interface
• 1 , 2 or 3 wires
•W
ith LED indicator (optional)
•W
ith fuse or disconnection per channel (optional)
• F use powered protection
• S crew or tension clamp connection
Universal solutions for PLC input/
output cards
RS IO - Passive interface for digital signals
RS 32IO 3W I R
R system, 3 wires with disconnection per channel
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Fuse per channel
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Connector RSV 1.6
36-pole female
No
No
No
3.15 A
No
150 V UC
1A
24 V DC ± 10%
3A
-25...+50°C
-40...+60 °C
CE
< 150 V AC
II
2
1.5 kV
Screw connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
188 mm / 109 mm
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
The common C may carry up to 3 A if the external jumpers are not used
Ordering data
Screw connection without LED
Type
RS 32IO 3W I R S
Height
84 mm
Order No.
9441610000
Note
Accessories
Note
1327330000 – 2012/2013
A.59
Universal solutions for PLC input/
output cards
Selection guide
A
RS A – Selection guide for passive interfaces
for analogue signals
Type of Interface
Number of
Family
channels
Connection
Screw
Tension clamp
connection
Features
Common distribution
V
4-channels
A1504
Z
V
Z
4-channels M
A1504M
A2508
Z
V
Z
8-channel P
A2508P
V
8-channel M
A2508M
V
16-channel
A3716
V
Z
V
Z
Note:
T
T
M
M
M
M
I
I
M
I
M
M
M
M
I
I
T
T
T
T
Interfaces
Order No.
Type
Page
9448000000
1308230000
9448100000
1308240000
1289090000
RS 4AIO DP SD S
RS 4AIO DP SD Z
RS 4AIO I-M-DP SD S
RS 4AIO I-M-DP SD Z
RS 4AIO DP-M258 SD S
A.61
A.61
A.61
A.61
A.62
9448010000
1308250000
9448110000
9449110000
RS 8AIO DP SD S
RS 8AIO DP SD Z
RS 8AIO I-M-DP SD S
RS 8AIO I-M-DP SD Z
A.63
A.63
A.63
A.63
9448030000
RS 8AI PREM/APR SD S
A.64
9448040000
RS 8AI1AO MICRO SD S
A.64
9448020000
1308270000
9448120000
1308280000
RS 16AIO DP SD S
RS 16AIO DP SD Z
RS 16AIO I-M-DP SD S
RS 16AIO I-M-DP SD Z
A.65
A.65
A.65
A.65
Coding of the interface descriptions
RS 4AIO: 4 inputs/outputs DP: Power distribution
8AIO: 8 inputs/outputs
(empty)
8AI: 8 inputs
8AI1AO: 8 inputs/1 outputs
16AIO: 16 inputs/outputs
A.60
I
I
Test points
V
V
8-channel
M
M
M
M
Disconnectable
I-M: Switch + Test point
SD connector SUB-D
M258: For Schneider M258
PREM/APR: For Schneider Premium
MICRO: For Schneider Micro (empty)
S: Screw
Z: Tension clamp connection
1327330000 – 2012/2013
RS A - Passive interface
for 4 analogue signals
Analogue input/output passive interface:
•W
ith test points or disconnection per channel (optional)
• S crew or tension clamp connection
RS 4AIO DP SD
RS 4AIO I-M-DP SD
4 channels
4 channels, test points and disconnection per channel
Universal solutions for PLC input/
output cards
RS A - Passive interface for analogue signals
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
SUB-D plug, in compliance with IEC 807-2 / DIN 41652
15-pole plug
No
No
3.15 A
No
SUB-D plug, in compliance with IEC 807-2 / DIN 41652
15-pole plug
No
No
3.15 A
Diameter: 4 mm
≤ 25 V AC / 50 V DC
0.5 A
24 V DC ± 10%
3A
≤ 25 V AC / 50 V DC
0.5 A
24 V DC ± 10%
3A
-20...+50°C
-40...+60 °C
CE
-20...+50°C
-40...+60 °C
CE
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
75 mm / 87 mm
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
75 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
73 mm / 109 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
73 mm / 109 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 4AIO DP SD S
RS 4AIO DP SD Z
Type
RS 4AIO I-M-DP SD S
RS 4AIO I-M-DP SD Z
Ordering data
Screw connection
Tension clamp connection
Height
72 mm
72 mm
Order No.
9448000000
1308230000
Height
81 mm
81 mm
Order No.
9448100000
1308240000
Note
Accessories
Note
1327330000 – 2012/2013
A.61
Universal solutions for PLC input/
output cards
RS A - Passive interface for analogue signals
RSA - Interface
for 4 analogue signals for Schneider M258
Analogue input/output passive interface:
•W
ith test points or disconnection per channel (optional)
• S crew or tension clamp connection
RS 4AIO DP-M258 SD
4 channels for M258 (Schneider), config. by voltage or current
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
SUB-D plug, in compliance with IEC 807-2 / DIN 41652
15-pole plug
No
No
No
No
≤ 25 V AC / 50 V DC
0.5 A
24 V DC ± 10%
3A
-20...+50°C
-40...+60 °C
CE
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
45 mm / 70 mm
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Ordering data
Screw connection
Type
RS 4AIO DP-M258 SD S
Height
60 mm
Order No.
1289090000
Note
Accessories
Note
A.62
1327330000 – 2012/2013
RSA - Interface
for 8 analogue signals
Analogue input/output passive interface:
•W
ith test points or disconnection per channel (optional)
• S crew or tension clamp connection
RS 8AIO DP SD
RS 8AIO I-M-DP SD
8 channels
8 channels, test points and disconnection per channel
Universal solutions for PLC input/
output cards
RS A - Passive interface for analogue signals
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
SUB-D plug, in compliance with IEC 807-2 / DIN 41652
25-pole plug
No
No
3.15 A
No
SUB-D plug, in compliance with IEC 807-2 / DIN 41652
25-pole plug
No
No
3.15 A
Diameter: 4 mm
≤ 25 V AC / 50 V DC
0.5 A
24 V DC ± 10%
3A
≤ 25 V AC / 50 V DC
0.5 A
24 V DC ± 10%
3A
-20...+50°C
-40...+60 °C
CE; GOSTME25
-20...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
117 mm / 87 mm
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
117 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
114 mm / 109 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
114 mm / 109 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 8AIO DP SD S
RS 8AIO DP SD Z
Type
RS 8AIO I-M-DP SD S
RS 8AIO I-M-DP SD Z
Ordering data
Screw connection
Tension clamp connection
Height
72 mm
72 mm
Order No.
9448010000
1308250000
Height
81 mm
81 mm
Order No.
9448110000
9449110000
Note
Accessories
Note
1327330000 – 2012/2013
A.63
Universal solutions for PLC input/
output cards
RS A - Passive interface for analogue signals
RSA - Interface
for 8 and 9 analogue signals for Schneider
Micro/Premium
RS 8AI PREM/APR SD
RS 8AI1AO MICRO SD
8 channels for Premium (Schneider) config. by volt. or current
9 channels for Micro (Schneider)
Analogue input/output passive interface:
•W
ith test points or disconnection per channel (optional)
• S crew or tension clamp connection
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
SUB-D plug, in compliance with IEC 807-2 / DIN 41652
25-pole plug
No
No
No
No
SUB-D plug, in compliance with IEC 807-2 / DIN 41652
15-pole plug
No
No
No
No
≤ 25 V AC / 50 V DC
0.5 A
24 V DC ± 10%
3A
≤ 25 V AC / 50 V DC
0.5 A
24 V DC ± 10%
3A
-20...+50°C
-40...+60 °C
CE; GOSTME25
-20...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
116 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
100 mm / 87 mm
The common C may carry up to 3 A if the external jumpers are not used
Ordering data
Screw connection
Type
RS 8AI PREM/APR SD S
Height
72 mm
Order No.
9448030000
Type
RS 8AI1AO MICRO SD S
Height
72 mm
Order No.
9448040000
Note
Accessories
Note
A.64
1327330000 – 2012/2013
RSA - Interface
for 16 analogue signals
Analogue input/output passive interface:
•W
ith test points or disconnection per channel (optional)
• S crew or tension clamp connection
RS 16AIO DP SD
RS 16AIO I-M-DP SD
16 channels
16 channels, test points and disconnection per channel
Universal solutions for PLC input/
output cards
RS A - Passive interface for analogue signals
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
LED status display per channel
LED status of the supply voltage
Power supply fuse
Type of test point
Rated data
Operating voltage
Max. current per channel
Operating voltage (supply)
Operating current (supply)
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated insulation voltage
Surge voltage category
Pollution severity level
Pulse voltage test (1,2/50μs)
SUB-D plug, in compliance with IEC 807-2 / DIN 41652
37-pole plug
No
No
3.15 A
No
SUB-D plug, in compliance with IEC 807-2 / DIN 41652
37-pole plug
No
No
3.15 A
Diameter: 4 mm
≤ 25 V AC / 50 V DC
0.5 A
24 V DC ± 10%
3A
≤ 25 V AC / 50 V DC
0.5 A
24 V DC ± 10%
3A
-20...+50°C
-40...+60 °C
CE; GOSTME25
-20...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
III
2
0.8 kV
< 50 V AC
III
2
0.8 kV
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
205 mm / 87 mm
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
205 mm / 87 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
197 mm / 109 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
197 mm / 109 mm
The common C may carry up to 3 A if the external jumpers are not used
The common C may carry up to 3 A if the external jumpers are not used
Type
RS 16AIO DP SD S
RS 16AIO DP SD Z
Type
RS 16AIO I-M-DP SD S
RS 16AIO I-M-DP SD Z
Ordering data
Screw connection
Tension clamp connection
Height
81 mm
72 mm
Order No.
9448020000
1308270000
Height
81 mm
81 mm
Order No.
9448120000
1308280000
Note
Accessories
Note
1327330000 – 2012/2013
A.65
Universal solutions for PLC input/
output cards
Selection guide
A
RSM – Selection guide for insulated interfaces
for digital input signals
Type of Interface
Number of
Family
channels
16-channel
I2016
Design
C
C
C
C
Screw
Features
Connection
Tension clamp connection
V
Z
V
Z
Interfaces
Voltage
Order No.
Type
24 V DC
24 V DC
48 V DC
48 V DC
1312000000
1312010000
1312020000
1312030000
RSM-16DI 24VDC S
RSM-16DI 24VDC Z
RSM-16DI 48VDC S
RSM-16DI 48VDC Z
Page
A.67
A.67
A.68
A.68
Note
A.66
1327330000 – 2012/2013
RSM - isolated interfaces
for 16 digital input signals
Relay digital input interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system:
• E lectrical insulation using pluggable relays
(interchangeable with solid-state relays; MICROSERIES
family)
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital input signals
RSM-16 DI 24 V DC
6 mm relays; 24 V DC AU
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. DC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category input/input
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RSS
green
yellow
2A
24 V DC ± 10%
13 mA
24 V DC ± 10%
2A
AgNi, gold flashed
24 V DC ± 10%
0.1 A
1 mA
1V
5 x 106 switching cycles
-20...+50°C
-20...+70 °C
CE
≤ 50 V DC
≤ 50 V DC
III
III
2
1.5 kV
0.35 kVAC
≥ 6 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
124 mm / 109 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
124 mm / 109 mm
Ordering data
Screw connection without switch
Tension-clamp connection without switch
Type
RSM-16DI 24VDC S
RSM-16DI 24VDC Z
Height
72 mm
72 mm
Order No.
1312000000
1312010000
Note
Accessories
Note
1327330000 – 2012/2013
Relay 4061590000 RSS 24 V DC 1CO AU
A.67
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital input signals
RSM - isolated interfaces
for 16 digital input signals
Relay digital input interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system:
• E lectrical insulation using pluggable relays
(interchangeable with solid-state relays; MICROSERIES
family)
RSM-16 DI 48 V DC
6 mm relays; 48 V DC AU
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. DC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category input/input
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RSS
green
yellow
2A
48 V DC ± 10%
10 mA
24 V DC ± 10%
2A
AgNi, gold flashed
24 V DC ± 10%
0.1 A
2 mA
5V
10 x 106 switching cycles
-20...+50°C
-20...+70 °C
CE
≤ 50 V DC
≤ 50 V DC
III
III
2
1.5 kV
0.35 kVAC
≥ 6 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
124 mm / 109 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
124 mm / 109 mm
Ordering data
Screw connection without switch
Tension-clamp connection without switch
Type
RSM-16DI 48VDC S
RSM-16DI 48VDC Z
Height
72 mm
72 mm
Order No.
1312020000
1312030000
Note
Accessories
Note
A.68
1327330000 – 2012/2013
A
1327330000 – 2012/2013
A.69
Universal solutions for PLC input/
output cards
Universal solutions for PLC input/
output cards
Selection guide
A
RSM – Selection guide for insulated interfaces
for digital output signals
Type of Interface
Number of
Family
channels
8-channel
O2008
12-channel
O2012
16-channel
Note 1:
O2016
Design:
Note 2:
A.70
Design
Connection
Screw Tension clamp
connection
Features
Voltage
Type of
contact
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
1CO
1CO
1CO
1CO
1CO
1CO
V
V
24 V DC
24 V DC
1CO
1CO
C
C
C
C
V
V
1 line
1 line
1 line
1 line
2 lines
2 lines
1 line
1 line
1 line
1 line
1 line
1 line
1 line
V
V
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC (+/-)
24 V DC (+/-)
24 V DC (+/-)
24 V DC (+/-)
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC
1CO
1CO
1CO
1CO
1CO
1CO
1CO
1CO
1CO
1CO
1CO
1CO
2CO
2CO
1CO
1CO
1CO
C
C
C
C
V
V
2 lines
2 lines
V
C
Z
Z
Z
2 lines
Z
Z
Z
Z
V
Z
V
Z
V
Z
V
Z
V
C
Relays with 6 mm relay
Fuse
Switch
(coil)
Switch
(contact)
P
P
P
P
P
P
F
F
P
Interfaces
Order No.
Type
1128970000
1128990000
1128980000
1129000000
9445000000
9447000000
RSM-8 PLC C 1CO S
RSM-8 PLC C SW 1CO S
RSM-8 PLC C 1CO Z
RSM-8 PLC C SW 1CO Z
RSM-8 C 1CO S
RSM-8 C 1CO Z
A.71
A.71
A.71
A.71
A.72
A.72
1289100000
9445060000
RSM-12 PLC C 1CO S
RSM-12 C 1CO S
A.73
A.74
1129010000
1129030000
1129020000
1129040000
1129100000
1129120000
1129110000
1129130000
9445100000
9447100000
9444610000
9444660000
9445160000
9447160000
9445120000
9447120000
9445140000
RSM-16 PLC C 1CO S
RSM-16 PLC C SW 1CO S
RSM-16 PLC C 1CO Z
RSM-16 PLC C SW 1CO Z
RSM-16 PLC 1CO S
RSM-16 PLC SW 1CO S
RSM-16 PLC 1CO Z
RSM-16 PLC SW 1CO Z
RSM-16 C 1CO S
RSM-16 C 1CO Z
RSM-16 24V(-/+) 1CO S
RSM-16 24V(-/+) 1CO Z
RSM-16 2CO S
RSM-16 2CO Z
RSM-16 FUS 1CO S
RSM-16 FUS 1CO Z
RSM-16 FOR 1CO S
A.75
A.75
A.75
A.75
A.76
A.76
A.76
A.76
A.77
A.77
A.78
A.78
A.79
A.79
A.80
A.80
A.81
1 line
2 lines
RCL Relays arranged in 1 single line
RCL relays (arranged in 2 rows)
Page
Voltage: Modules indicated with 24 V DC (+/-) can function as positive or negative and can function with negative logic PLC cards
1327330000 – 2012/2013
RSM - Interfaces
for 8 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
RSM-8 PLC C 1CO
6 mm relay with 1 CO contact and switch
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RSS
green
yellow
No
2.5 A
24 V DC ± 10%
13 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
2.5 A
0.1 A
5V
5 x 106 switching cycles
-25...+50°C
-40...+60 °C
CE
< 50 V AC
250 V AC
III
II
2
6 kV
1.2 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
75 mm / 109 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
75 mm / 109 mm
Ordering data
Screw connection without switch
Screw connection with switch
Tension-clamp connection without switch
Tension-clamp connection with switch
Type
RSM-8 PLC C 1CO S
RSM-8 PLC C SW 1CO S
RSM-8 PLC C 1CO Z
RSM-8 PLC C SW 1CO Z
Note
Height
85 mm
85 mm
80 mm
80 mm
Order No.
1128970000
1128990000
1128980000
1129000000
Accessories
Note
1327330000 – 2012/2013
Relay 4060120000 RSS 24 V DC 1CO
A.71
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
RSM - Interfaces
for 8 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
RSM-8 C 1C
RCL relays (arranged in 2 rows) with 1 CO contact
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RCL
green
yellow
No
3.15 A
24 V DC ± 10%
20 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
5A
0.01 A
12 V
3 x 107 switching cycles
-25...+50°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
< 250 V AC
III
II
2
6 kV
1.2 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 35, TS 32
110 mm / 109 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 35, TS 32
110 mm / 109 mm
Ordering data
Screw connection without switch
Screw connection with switch
Tension-clamp connection without switch
Tension-clamp connection with switch
Type
RSM-8 C 1CO S
Height
68 mm
Order No.
9445000000
RSM-8 C 1CO Z
68 mm
9447000000
Note
Accessories
Note
A.72
Relay 8693260000 RCL314024 24 V DC 1CO
1327330000 – 2012/2013
RSM - Interfaces
for 12 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
RSM-12 PLC 1C
6 mm relay with 1 CO contact
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RSS
green
yellow
No
2.5 A
24 V DC ± 10%
13 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
2.5 A
0.1 A
5V
5 x 106 switching cycles
-25...+50°C
-40...+60 °C
< 50 V AC
250 V AC
III
II
2
6 kV
1.2 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
95 mm / 109 mm
Ordering data
Screw connection without switch
Type
RSM-12 PLC C 1CO S
Height
85 mm
Order No.
1289100000
Note
Accessories
Note
1327330000 – 2012/2013
Relay 4060120000 RSS 24 V DC 1CO
A.73
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
RSM - Interfaces
for 12 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
RSM-12 C 1CO S
RCL relays (arranged in 2 rows) with 1 CO contact
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RCL
green
yellow
No
3.15 A
24 V DC ± 10%
20 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
5A
0.01 A
12 V
3 x 107 switching cycles
-25...+40°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
< 250 V AC
III
II
2
6 kV
1.2 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 35, TS 32
147 mm / 109 mm
Ordering data
Screw connection without switch
Type
RSM-12 C 1CO S
Height
68 mm
Order No.
9445060000
Note
Accessories
Note
A.74
Relay 8693260000 RCL314024 24 V DC 1CO
1327330000 – 2012/2013
RSM - Interfaces
for 16 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
RSM-16 PLC C 1CO
6 mm relay with 1 CO contact and switch
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RSS
green
yellow
No
2.5 A
24 V DC ± 10%
13 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
2.5 A
0.1 A
5V
5 x 106 switching cycles
-25...+50°C
-40...+60 °C
CE
< 50 V AC
250 V AC
III
II
2
6 kV
1.2 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
111 mm / 109 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
111 mm / 109 mm
Ordering data
Screw connection without switch
Screw connection with switch
Tension-clamp connection without switch
Tension-clamp connection with switch
Type
RSM-16 PLC C 1CO S
RSM-16 PLC C SW 1CO S
RSM-16 PLC C 1CO Z
RSM-16 PLC C SW 1CO Z
Note
Height
85 mm
85 mm
80 mm
80 mm
Order No.
1129010000
1129030000
1129020000
1129040000
Accessories
Note
1327330000 – 2012/2013
Relay 4060120000 RSS 24 V DC 1CO
A.75
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
RSM - Interfaces
for 16 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
RSM-16 PLC 1CO
6 mm relay with 1 CO contact and switch
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RCL
green
yellow
No
2.5 A
24 V DC ± 10%
22 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
6A
0.01 A
12 V
3 x 107 switching cycles
-25...+50°C
-40...+60 °C
CE
< 50 V AC
250 V AC
III
II
2
6 kV
1.2 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 32, TS 35
255 mm / 109 mm
Tension clamp connection
0.13 mm² / 2.5 mm²
0.13 mm² / 2.5 mm²
TS 32, TS 35
255 mm / 109 mm
Ordering data
Screw connection without switch
Screw connection with switch
Tension-clamp connection without switch
Tension-clamp connection with switch
Type
RSM-16 PLC 1CO S
RSM-16 PLC SW 1CO S
RSM-16 PLC 1CO Z
RSM-16 PLC SW 1CO Z
Note
Height
68 mm
68 mm
68 mm
68 mm
Order No.
1129100000
1129120000
1129110000
1129130000
Accessories
Note
A.76
Relay 8693260000 RCL314024 24 V DC 1CO
1327330000 – 2012/2013
RSM - Interfaces
for 16 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
RSM-16 C 1CO
RCL relays (arranged in 2 rows) with 1 CO contact
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RCL
green
yellow
No
3.15 A
24 V DC ± 10%
20 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
5A
0.01 A
12 V
3 x 107 switching cycles
-25...+40°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
< 250 V AC
III
II
2
6 kV
1.2 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 35, TS 32
185 mm / 109 mm
Tension clamp connection
0.15 mm² / 1.5 mm²
0.15 mm² / 1.5 mm²
TS 35, TS 32
185 mm / 109 mm
Ordering data
Screw connection without switch
Screw connection with switch
Tension-clamp connection without switch
Tension-clamp connection with switch
Type
RSM-16 C 1CO S
Height
68 mm
Order No.
9445100000
RSM-16 C 1CO Z
68 mm
9447100000
Note
Accessories
Note
1327330000 – 2012/2013
Relay 8693260000 RCL314024 24 V DC 1CO
A.77
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
RSM - Interfaces
for 16 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
RSM-16 24 V(-/+) 1CO
RCL relays, 24 V DC voltage with 1 CO contact
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RCL
green
yellow
No
No
24 V DC ± 10%
22 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
5A
0.01 A
12 V
3 x 107 switching cycles
-25...+40°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
< 250 V AC
III
II
2
6 kV
2.5 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 35, TS 32
267 mm / 87.5 mm
Tension clamp connection
0.15 mm² / 1.5 mm²
0.15 mm² / 1.5 mm²
TS 35, TS 32
267 mm / 87.5 mm
Ordering data
Screw connection without switch
Screw connection with switch
Tension-clamp connection without switch
Tension-clamp connection with switch
Type
RSM-16 24V(-/+) 1CO S
Height
68 mm
Order No.
9444610000
RSM-16 24V(-/+) 1CO Z
68 mm
9444660000
Note
Accessories
Note
A.78
Relay 8693260000 RCL314024 24 V DC 1CO
1327330000 – 2012/2013
RSM - Interfaces
for 16 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
RSM-16 2CO
RCL relays with 2 CO contacts
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RCL
green
yellow
No
3.15 A
24 V DC ± 10%
17 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
4A
0.01 A
12 V
3 x 107 switching cycles
-25...+40°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
< 250 V AC
III
II
2
6 kV
2.5 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 35, TS 32
263 mm / 109 mm
Tension clamp connection
0.15 mm² / 1.5 mm²
0.15 mm² / 1.5 mm²
TS 35, TS 32
263 mm / 109 mm
Ordering data
Screw connection without switch
Screw connection with switch
Tension-clamp connection without switch
Tension-clamp connection with switch
Type
RSM-16 2CO S
Height
68 mm
Order No.
9445160000
RSM-16 2CO Z
68 mm
9447160000
Note
Accessories
Note
1327330000 – 2012/2013
Relay 4058570000 RCL424024 2CO
A.79
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
RSM - Interfaces
for 16 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
RSM-16 FUS 1CO
RCL relays, 1 CO contact with fuse relay contact
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RCL
green
yellow
5A
3.15 A
24 V DC ± 10%
20 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
5A
0.01 A
12 V
3 x 107 switching cycles
-25...+40°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
< 250 V AC
III
II
2
6 kV
1.2 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 35, TS 32
261 mm / 109 mm
Tension clamp connection
0.15 mm² / 1.5 mm²
0.15 mm² / 1.5 mm²
TS 35, TS 32
261 mm / 109 mm
Ordering data
Screw connection without switch
Screw connection with switch
Tension-clamp connection without switch
Tension-clamp connection with switch
Type
RSM-16 FUS 1CO S
Height
75 mm
Order No.
9445120000
RSM-16 FUS 1CO Z
75 mm
9447120000
Note
Accessories
Note
A.80
Relay 8693260000 RCL314024 24 V DC 1CO
1327330000 – 2012/2013
RSM - Interfaces
for 16 isolated digital output signals
Relay digital output interface for transmitting electrical
signals between the PLC and the field via pre-wired cables
of Weidmüller’s universal system.
• Input/output reinforced insulation (basic between
contacts)
Universal solutions for PLC input/
output cards
RSM - isolated interfaces for digital output signals
RSM-16 FOR 1CO
RCL relays, 1 CO contact and switch
A
Technical data
Connection data and functionality
Connection on control side
Number of poles (control side)
Relay type
LED status display per relay
LED status of the supply voltage
Fuse per relay
Power supply fuse
Nominal input data
Input voltage
Input current
Operating voltage (supply)
Operating current (supply)
Nominal output data
Contact material
Operating voltage
Max. AC continuous current
Minimum contact current
Minimum contact voltage
Mechanical service life
General data
Ambient temperature (operational)
Storage temperature
Approvals
Insulation coordination (EN50178)
Rated input insulation voltage
Rated output insulation voltage
Overvoltage category input/output
Overvoltage category output/output
Pollution severity level
Pulse voltage test (1,2/50μs)
Insulation test voltage
Clearance input/output
Dimensions
Clamping range, min. /max. [Field]
Clamping range, min. /max. [supply]
Mounting rail
Length x width
Note
Plug-in connector acc. IEC 603-1 / DIN 41651
20-pole plug
RCL
green
yellow
No
3.15 A
24 V DC ± 10%
17 mA
24 V DC ± 10%
2A
AgNi 90/10
250 V AC
2A
0.01 A
12 V
3 x 107 switching cycles
-25...+40°C
-40...+60 °C
CE; GOSTME25
< 50 V AC
< 250 V AC
III
II
2
6 kV
1.2 kVAC
≥ 5.5 mm
Screw connection
0.13 mm² / 6 mm²
0.13 mm² / 6 mm²
TS 35, TS 32
263 mm / 109 mm
Ordering data
Screw connection without switch
Screw connection with switch
Tension-clamp connection without switch
Tension-clamp connection with switch
Type
RSM-16 FOR 1CO S
Height
75 mm
Order No.
9445140000
Note
Accessories
Note
1327330000 – 2012/2013
Relay 8693260000 RCL314024 24 V DC 1CO
A.81
Universal solutions for PLC input/
output cards
Selection guide
A
PAC-UNIV Universal pre-asembled cables
You can choose the ideal pre-assembled cable for your PLC card from the following tables. Calculate voltage and current
values allowed by the cable as dictated by the application. More technical information can be found in our
on-line catalogue at www.weidmueller.com
Input/Output cards
Siemens S7-300
6ES7312-5BD00-0AB0
6ES7312-5BD01-0AB0
6ES7312-5BE03-0AB0
6ES7313-5BE00-0AB0
6ES7313-5BE01-0AB0
6ES7313-5BF03-0AB0
6ES7313-6BE00-0AB0
6ES7313-6BE01-0AB0
6ES7313-6BF03-0AB0
6ES7313-6CE00-0AB0
6ES7313-6CE01-0AB0
6ES7313-6CF03-0AB0
6ES7314-6BF00-0AB0
6ES7314-6BF01-0AB0
6ES7314-6BF02-0AB0
6ES7314-6CF00-0AB0
6ES7314-6CF01-0AB0
6ES7314-6CF02-0AB0
6ES7321-1BH00-0AA0
6ES7321-1BH01-0AA0
6ES7321-1BH02-0AA0
6ES7321-1BH50-0AA0
6ES7321-1BH80-0AA0
6ES7321-1BH81-0AA0
6ES7321-1BH82-0AA0
6ES7321-1BL00-0AA0
6ES7321-1BL80-0AA0
6ES7321-1BP00-0AA0
6ES7321-1CH20-0AA0
6ES7321-1CH80-0AA0
6ES7321-1EH00-0AA0
6ES7321-1EH01-0AA0
6ES7321-1EL00-0AA0
6ES7321-1FF00-0AA0
6ES7321-1FF01-0AA0
6ES7321-1FF81-0AA0
6ES7321-1FH00-0AA0
6ES7321-7BH00-0AB0
6ES7321-7BH01-0AB0
6ES7321-7BH80-0AB0
6ES7321-7RD00-0AB0
6ES7322-1BF00-0AA0
6ES7322-1BF01-0AA0
6ES7322-1BH00-0AA0
6ES7322-1BH01-0AA0
6ES7322-1BH10-0AA0
6ES7322-1BH81-0AA0
6ES7322-1BL00-0A00
6ES7322-1BP00-0AA0
6ES7322-1BP50-0AA0
6ES7322-1CF00-0AA0
6ES7322-1CF80-0AA0
6ES7322-1EH00-0AA0
6ES7322-1EH01-0AA0
6ES7322-1EL00-0AA0
6ES7322-1FF00-0AA0
6ES7322-1FF01-0AA0
6ES7322-1FF81-0AA0
6ES7322-1FH00-0AA0
6ES7322-1FL00-0AA0
A.82
Cables
7789606xxx
7789606xxx
7789606xxx
7789608xxx +
7789609xxx
7789608xxx +
7789609xxx
7789608xxx +
7789609xxx
7789608xxx
7789608xxx
7789608xxx
7789608xxx
7789608xxx
7789608xxx
7789608xxx +
7789609xxx
7789608xxx +
7789609xxx
7789608xxx +
7789609xxx
7789608xxx +
7789609xxx
7789608xxx +
7789609xxx
7789608xxx +
7789609xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789608xxx
7789608xxx
7789790xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789608xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789608xxx
7789790xxx
7789790xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
Unit/
card
1
1
1
1+1
1+1
1+1
1
1
1
1
1
1
1+1
1+1
1+1
1+1
1+1
1+1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
2
1
1
1
1
2
Input/Output cards
Siemens S7-300
6ES7322-1HF10-0AA0
6ES7322-1HF80-0AA0
6ES7322-5RD00-0AB0
6ES7322-5SD00-0AB0
6ES7322-8BF00-0AB0
6ES7322-8BH01-0AB0
6ES7323-1BH00-0A00
6ES7323-1BH01-00A0
6ES7323-1BH80-0A00
6ES7323-1BH80-0AA0
6ES7323-1BL00-0AA0
6ES7331-1KF01-0AB0
6ES7331-1KF02-0AB0
6ES7331-7KB00-0AB0
6ES7331-7KB01-0AB0
6ES7331-7KB02-0AB0
6ES7331-7KF00-0AB0
6ES7331-7KF01-0AB0
6ES7331-7KF02-0AB0
6ES7331-7NF00-0AB0
6ES7331-7PF00-0AB0
6ES7331-7PF01-0AB0
6ES7331-7RD00-0AB0
6ES7331-7TF01-0AB0
6ES7332-5HB00-0AB0
6ES7332-5HB01-0AB0
6ES7332-5HB81-0AB0
6ES7332-5HD00-0AB0
6ES7332-5HD01-0AB0
6ES7332-5HF00-0AB0
6ES7332-5RD00-0AB0
6ES7332-7ND01-0AB0
6ES7332-7ND02-0AB0
6ES7334-0CE01-0AA0
6ES7334-0KE00-0AB0
6ES7335-7HG01-0AB0
6ES7335-7HG02-0AB0
Input/Output cards
Rockwell Control-Logix
1756-IA16
1756-IA16I
1756-IA8D
1756-IB16
1756-IB16D
1756-IB16I
1756-IB32
1756-IC16
1756-IF16
1756-IF6I
1756-IF8
1756-IH16I
1756-IM16I
1756-IN16
1756-IR6I
1756-OA16
1756-OA16I
1756-OA8
1756-OA8D
1756-OA8E
1756-OB16D
1756-OB16E
1756-OB16I
1756-OB32
1756-OB8
1756-OB8EI
1756-OC8
1756-OF4
Cables
7789608xxx
7789608xxx
7789606xxx
7789606xxx
7789606xxx
7789608xxx
7789606xxx
7789606xxx
7789606xxx
7789606xxx
7789608xxx
7789609xxx
7789609xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
7789609xxx
7789609xxx
7789609xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
7789609xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
7789607xxx
Cables
7789731xxx
7789733xxx
7789731xxx
7789731xxx
7789733xxx
7789733xxx
7789733xxx
7789731xxx
7789734xxx
7789732xxx
7789734xxx
7789733xxx
7789733xxx
7789731xxx
7789732xxx
7789731xxx
7789733xxx
7789731xxx
7789731xxx
7789731xxx
7789733xxx
7789731xxx
7789733xxx
7789733xxx
7789731xxx
7789733xxx
7789731xxx
7789732xxx
Unit/
card
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Unit/
card
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
PAC- UNIV
Pre-assembled cables
•At one end of the PLC connector
•The other end has a wire-end ferrule
•Shielded cable with 0.25 mm2 cross section for
analogue cards and un-shielded for digital cards.
Input/Output cards
Rockwell Control-Logix
1756-OF6CI
1756-OF6VI
1756-OF8
1756-OH8I
1756-ON8
1756-OV16E
1756-OW16I
1756-OX8I
Cables
Input/Output cards
Omron CJ1W
ID231
ID232
ID261
ID262
OD231
OD232
OD233
OD261
OD262
OD263
Cables
Input/Output cards
Mitsubishi Melsec Q
QH42P
QX41
QX41-S1
QX41Y41P
QX42
QX42-S1
QX71
QX72
QX82
QX82-S1
QY41P
QY42P
QY71
Cables
7789732xxx
7789732xxx
7789732xxx
7789733xxx
7789731xxx
7789731xxx
7789733xxx
7789733xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
7789790xxx
Unit/
card
1
1
1
1
1
1
1
1
Unit/
card
1
1
2
2
1
1
1
2
2
2
Unit/
card
2
1
1
2
2
2
1
2
2
2
1
2
1
Universal pre-assembled cable composition
Cables
PLC Connector
7789606xxx
7789607xxx
7789608xxx
7789609xxx
7789731xxx
7789732xxx
7789733xxx
7789734xxx
7789790xxx
S7300 6ES7921-3AH0-1AA0 20P
S7300 6ES7921-3AH0-1AA0 20P
S7300 6ES7921-3AH20-1AA0 40P
S7300 6ES7921-3AH20-1AA0 40P
1756-TBNH 20P
1756-TBNH 20P
1756-TBCH 36P
1756-TBCH 36P
FCN 40P
Cable
type
LIYY
LiYCY
LIYY
LiYCY
LIYY
LiYCY
LIYY
LiYCY
LIYY
The last 3 digits of the cable code indicate its length in decimetres For example,
if the code ends in 100, the cable would be 10 m long.
1327330000 – 2012/2013