Base and end plates, type C
Base plate
► ISO 15407-2 - inch ► standard: ISO 15407-2 ► Frame size: 26 mm ► type C ► Can
be assembled into blocks ► Single base plate principle ► Reversed pressure supply
permissible ► With collective pilot air exhaust ► for CD01-PI
Base plate
► ISO 15407-2 - inch ► standard: ISO 15407-2 ► Frame size: 26 mm ► type C ► Can
be assembled into blocks ► Double base plate principle ► Reversed pressure supply
permissible ► for CD01-PI
End plate right
► ISO 15407-2 - inch ► type C ► Reversed pressure supply permissible
End plate left
► ISO 15407-2 - inch ► type C ► Reversed pressure supply permissible ► With collective
pilot air exhaust
3
4
6
8
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change
3
Valve systems ► Base plates, according to standard
Base plate
► ISO 15407-2 - inch ► standard: ISO 15407-2 ► Frame size: 26 mm ► type C ► Can be assembled into blocks
► Single base plate principle ► Reversed pressure supply permissible ► With collective pilot air exhaust
► for CD01-PI
00135243
Standards
ISO 15407-2, 26 mm
Ambient temperature min./max.
-15°C / +50°C
Medium temperature min./max.
-5°C / +50°C
Medium
Compressed air
Working pressure min./max.
-0.95 bar / 16 bar
Number of valve positions
1
Grid dimension
27 mm
Mounting screw
with hexagon socket
Tightening torque for mounting screws
5 Nm±0,5
Exhaust (3,5)
With directional exhaust (3/5)
Ports separated
Compressed air connection
according to ISO 15407-2
Materials:
Base plate
Aluminum
Seals
Acrylonitrile butadiene rubber
Technical Remarks
■ The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
■ The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C.
■ The oil content of compressed air must remain constant during the life cycle.
■ Use only the approved oils from AVENTICS, see chapter „Technical information“.
Type
Frame size
Base plate for 1 single solenoid valve
Base plate for a single or double solenoid
valve
Port
1/4″ NPTF
R412012474
26 mm
1/4″ NPTF
R412012478
Scope of delivery incl. seal and mounting screws
Dimensions in mm
11
33
60,2
14,5
27
90
6,15
66
4
23
Part No.
26 mm
124
00135257
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change
4
Valve systems ► Base plates, according to standard
Base plate
► ISO 15407-2 - inch ► standard: ISO 15407-2 ► Frame size: 26 mm ► type C ► Can be assembled into blocks
► Double base plate principle ► Reversed pressure supply permissible ► for CD01-PI
00135244
Standards
ISO 15407-2, 26 mm
Ambient temperature min./max.
-15°C / +50°C
Medium temperature min./max.
-5°C / +50°C
Medium
Compressed air
Working pressure min./max.
-0.95 bar / 16 bar
Number of valve positions
2
Grid dimension
54 mm
Mounting screw
with hexagon socket
Tightening torque for mounting screws
5 Nm±0,5
Ports separated
Compressed air connection
according to ISO 15407-2
Materials:
Base plate
Aluminum
Seals
Acrylonitrile butadiene rubber
Technical Remarks
■ The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
■ The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C.
■ The oil content of compressed air must remain constant during the life cycle.
■ Use only the approved oils from AVENTICS, see chapter „Technical information“.
Type
Base plate for two single or double solenoid
valves
Frame size
Port
Part No.
26 mm
1/4 NPT
R412012482
Scope of delivery incl. seal and mounting screws
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change
5
Valve systems ► Base plates, according to standard
Base plate
► ISO 15407-2 - inch ► standard: ISO 15407-2 ► Frame size: 26 mm ► type C ► Can be assembled into blocks
► Double base plate principle ► Reversed pressure supply permissible ► for CD01-PI
Dimensions in mm
11
33
60,2
14,5
27
27
90
4
23
6,15
66
124
00135259
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change
6
Valve systems ► Base plates, according to standard
End plate right
► ISO 15407-2 - inch ► type C ► Reversed pressure supply permissible
Ambient temperature min./max.
-15°C / +50°C
Medium temperature min./max.
-5°C / +50°C
Medium
Compressed air
Working pressure min./max.
-0.95 bar / 16 bar
Ports separated
Materials:
00135241
Base plate
Die-cast aluminum
Seals
Acrylonitrile butadiene rubber
Technical Remarks
■ The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
■ The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C.
■ The oil content of compressed air must remain constant during the life cycle.
■ Use only the approved oils from AVENTICS, see chapter „Technical information“.
Input
[1]
3/8 NPT
Compressed air connection
Exhaust Pilot control exhaust
Pilot connection
[3 / 5]
[12]
[14]
3/8-18 NPTF
1/8 NPT
1/8-27 NPTF
Pilot
Part No.
external
R412012470
internal
R412012472
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change
7
Valve systems ► Base plates, according to standard
End plate right
► ISO 15407-2 - inch ► type C ► Reversed pressure supply permissible
Dimensions in mm
119,5
32
7
77
46,5
18,3
90
5
55,2
13,85
27,5
64,7
60
93
62
43
3,35
17,2
12,5
11
130
00135255
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change
8
Valve systems ► Base plates, according to standard
End plate left
► ISO 15407-2 - inch ► type C ► Reversed pressure supply permissible ► With collective pilot air exhaust
Ambient temperature min./max.
-15°C / +50°C
Medium temperature min./max.
-5°C / +50°C
Medium
Compressed air
Working pressure min./max.
-0.95 bar / 16 bar
Materials:
Base plate
Die-cast aluminum
Seals
Acrylonitrile butadiene rubber
00135242
Technical Remarks
■ The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result!
■ The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C.
■ The oil content of compressed air must remain constant during the life cycle.
■ Use only the approved oils from AVENTICS, see chapter „Technical information“.
Compressed air connection
Exhaust Pilot control exhaust
Pilot connection
[3 / 5]
[12]
[14]
Input
[1]
Pilot
Part No.
3/8-18 NPTF
3/8-18 NPTF
1/8 NPT
1/8-27 NPTF
external
R412012466
3/8 NPT
3/8-18 NPTF
1/8 NPT
1/8-27 NPTF
internal
R412012468
33
12
Dimensions in mm
77
119,5
46,5
67
93
67,4
90
43
3,35
10,5
12,5
21,7
23
13,85
27,5
55,2
18,3
110
00135256
Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information
Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change
AVENTICS GmbH
Ulmer Straße 4
30880 Laatzen, GERMANY
Phone +49 511 2136-0
Fax +49 511 2136-269
www.aventics.com
[email protected]
Find more contact information at
www.aventics.com/contact
Only use the AVENTICS products
shown in industrial applications.
Read the product documentation
completely and carefully before using
the product.
Observe the applicable regulations
and laws of the respective country.
When integrating the product into
applications, note the system
manufacturer’s specifications for safe
use of the product.
The data specified only serve to
describe the product.
No statements concerning a certain
condition or suitability for a certain
application can be derived from our
information.
The information given does not
release the user from the obligation
of own judgment and verification.
It must be remembered that the
products are subject to a natural
process of wear and aging.
13-04-2017
An example configuration is depicted on the title page. The delivered product may thus vary from that in the
illustration. Subject to change. © AVENTICS S.à r.l.
This document, as well as the data, specifications and other information set forth in it, are the exclusive property of
AVENTICS S.à r.l.. It may not be reproduced or given to third parties without its consent. PDF online