Valve systems ► Base plates, according to standard ISO 15407-2 - inch Brochure 2 Valve systems ► Base plates, according to standard ISO 15407-2 - inch Base and end plates, type C Base plate ► ISO 15407-2 - inch ► standard: ISO 15407-2 ► Frame size: 26 mm ► type C ► Can be assembled into blocks ► Single base plate principle ► Reversed pressure supply permissible ► With collective pilot air exhaust ► for CD01-PI Base plate ► ISO 15407-2 - inch ► standard: ISO 15407-2 ► Frame size: 26 mm ► type C ► Can be assembled into blocks ► Double base plate principle ► Reversed pressure supply permissible ► for CD01-PI End plate right ► ISO 15407-2 - inch ► type C ► Reversed pressure supply permissible End plate left ► ISO 15407-2 - inch ► type C ► Reversed pressure supply permissible ► With collective pilot air exhaust 3 4 6 8 Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change 3 Valve systems ► Base plates, according to standard Base plate ► ISO 15407-2 - inch ► standard: ISO 15407-2 ► Frame size: 26 mm ► type C ► Can be assembled into blocks ► Single base plate principle ► Reversed pressure supply permissible ► With collective pilot air exhaust ► for CD01-PI 00135243 Standards ISO 15407-2, 26 mm Ambient temperature min./max. -15°C / +50°C Medium temperature min./max. -5°C / +50°C Medium Compressed air Working pressure min./max. -0.95 bar / 16 bar Number of valve positions 1 Grid dimension 27 mm Mounting screw with hexagon socket Tightening torque for mounting screws 5 Nm±0,5 Exhaust (3,5) With directional exhaust (3/5) Ports separated Compressed air connection according to ISO 15407-2 Materials: Base plate Aluminum Seals Acrylonitrile butadiene rubber Technical Remarks ■ The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! ■ The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C. ■ The oil content of compressed air must remain constant during the life cycle. ■ Use only the approved oils from AVENTICS, see chapter „Technical information“. Type Frame size Base plate for 1 single solenoid valve Base plate for a single or double solenoid valve Port 1/4″ NPTF R412012474 26 mm 1/4″ NPTF R412012478 Scope of delivery incl. seal and mounting screws Dimensions in mm 11 33 60,2 14,5 27 90 6,15 66 4 23 Part No. 26 mm 124 00135257 Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change 4 Valve systems ► Base plates, according to standard Base plate ► ISO 15407-2 - inch ► standard: ISO 15407-2 ► Frame size: 26 mm ► type C ► Can be assembled into blocks ► Double base plate principle ► Reversed pressure supply permissible ► for CD01-PI 00135244 Standards ISO 15407-2, 26 mm Ambient temperature min./max. -15°C / +50°C Medium temperature min./max. -5°C / +50°C Medium Compressed air Working pressure min./max. -0.95 bar / 16 bar Number of valve positions 2 Grid dimension 54 mm Mounting screw with hexagon socket Tightening torque for mounting screws 5 Nm±0,5 Ports separated Compressed air connection according to ISO 15407-2 Materials: Base plate Aluminum Seals Acrylonitrile butadiene rubber Technical Remarks ■ The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! ■ The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C. ■ The oil content of compressed air must remain constant during the life cycle. ■ Use only the approved oils from AVENTICS, see chapter „Technical information“. Type Base plate for two single or double solenoid valves Frame size Port Part No. 26 mm 1/4 NPT R412012482 Scope of delivery incl. seal and mounting screws Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change 5 Valve systems ► Base plates, according to standard Base plate ► ISO 15407-2 - inch ► standard: ISO 15407-2 ► Frame size: 26 mm ► type C ► Can be assembled into blocks ► Double base plate principle ► Reversed pressure supply permissible ► for CD01-PI Dimensions in mm 11 33 60,2 14,5 27 27 90 4 23 6,15 66 124 00135259 Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change 6 Valve systems ► Base plates, according to standard End plate right ► ISO 15407-2 - inch ► type C ► Reversed pressure supply permissible Ambient temperature min./max. -15°C / +50°C Medium temperature min./max. -5°C / +50°C Medium Compressed air Working pressure min./max. -0.95 bar / 16 bar Ports separated Materials: 00135241 Base plate Die-cast aluminum Seals Acrylonitrile butadiene rubber Technical Remarks ■ The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! ■ The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C. ■ The oil content of compressed air must remain constant during the life cycle. ■ Use only the approved oils from AVENTICS, see chapter „Technical information“. Input [1] 3/8 NPT Compressed air connection Exhaust Pilot control exhaust Pilot connection [3 / 5] [12] [14] 3/8-18 NPTF 1/8 NPT 1/8-27 NPTF Pilot Part No. external R412012470 internal R412012472 Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change 7 Valve systems ► Base plates, according to standard End plate right ► ISO 15407-2 - inch ► type C ► Reversed pressure supply permissible Dimensions in mm 119,5 32 7 77 46,5 18,3 90 5 55,2 13,85 27,5 64,7 60 93 62 43 3,35 17,2 12,5 11 130 00135255 Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change 8 Valve systems ► Base plates, according to standard End plate left ► ISO 15407-2 - inch ► type C ► Reversed pressure supply permissible ► With collective pilot air exhaust Ambient temperature min./max. -15°C / +50°C Medium temperature min./max. -5°C / +50°C Medium Compressed air Working pressure min./max. -0.95 bar / 16 bar Materials: Base plate Die-cast aluminum Seals Acrylonitrile butadiene rubber 00135242 Technical Remarks ■ The min. control pressure must be adhered to, since otherwise faulty switching and valve failure may result! ■ The pressure dew point must be at least 15 °C under ambient and medium temperature and may not exceed 3 °C. ■ The oil content of compressed air must remain constant during the life cycle. ■ Use only the approved oils from AVENTICS, see chapter „Technical information“. Compressed air connection Exhaust Pilot control exhaust Pilot connection [3 / 5] [12] [14] Input [1] Pilot Part No. 3/8-18 NPTF 3/8-18 NPTF 1/8 NPT 1/8-27 NPTF external R412012466 3/8 NPT 3/8-18 NPTF 1/8 NPT 1/8-27 NPTF internal R412012468 33 12 Dimensions in mm 77 119,5 46,5 67 93 67,4 90 43 3,35 10,5 12,5 21,7 23 13,85 27,5 55,2 18,3 110 00135256 Part numbers marked in bold are available from the central warehouse in Germany, see the shopping basket for more detailed information Pneumatics catalog, online PDF, as of 2017-04-13, ©AVENTICS S.à r.l., subject to change AVENTICS GmbH Ulmer Straße 4 30880 Laatzen, GERMANY Phone +49 511 2136-0 Fax +49 511 2136-269 www.aventics.com [email protected] Find more contact information at www.aventics.com/contact Only use the AVENTICS products shown in industrial applications. Read the product documentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. When integrating the product into applications, note the system manufacturer’s specifications for safe use of the product. The data specified only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that the products are subject to a natural process of wear and aging. 13-04-2017 An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. © AVENTICS S.à r.l. This document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS S.à r.l.. It may not be reproduced or given to third parties without its consent. PDF online
© Copyright 2026 Paperzz