Audiometric sound rooms

Audiometric
sound rooms
View our portfolio of sound room
www.otometrics.com/soundrooms
GENIE™
Audiometric sound rooms
The GENIE™ series of audiometric sound rooms has provided state-of-the-art
performance and quality since 2001. Over the years, feedback from customers and
patients, audiologists, acousticians and engineers has been used to optimize the
design of the product. The GENIE sound room is a solution infused with science
and uncompromising dedication to customer needs.
Customized to your needs
GENIE sound rooms are fully
customizable. We offer a diverse
audiometric product line ranging from
double wall exam suites for optimal
noise management to small occupational
health mobile rooms. If a standard
size room doesn’t fit your needs, we
customize it to make the most of your
available space.
GENIE sound rooms have a variety of
configurable options, features and
accessories and offer a variety of trims
and finishes. A wide range of colors and
interior design packages are available to
match any decor. Simply select a size,
configuration, and feature package that
works best for your new clinic.
Equipment integration
The GENIE series is a state-of-the-art
audiometric sound room solution. It
integrates perfectly with any equipment
in your clinic. This integration allows
you to provide exceptional patient care
in a controlled environment today, and
adapts to the technologies you will be
using in the future.
Our experienced sales staff builds your
sound room according to how you want
to use your equipment. We help you
integrate your audiometric equipment
with your new noise controlled space.
Integrated instrumentation results in
an optimized workflow and a superior
patient experience in a controlled
acoustic environment.
End-to-end solution
Whether you are designing a new clinic
or adding to your existing space, we
guide you every step of the way. Our
extensive audiology experience and
consultative approach ensure a seamless
experience for you in sound room
design, delivery and installation.
Otometrics sound room division sales
engineers and our local partners work
closely with you throughout the entire
process. Each sound room comes with
professional project management and
complete installation. All of our sales
engineers and installation teams are
factory trained, evaluated and certified
for quality assurance.
03
GENIE™ sound rooms have a variety of configurable
options, features and accessories and offer a variety of
trims and finishes. A wide range of colors and interior
design packages are available to match any decor.
• Acoustically engineered doors
Our doors provide easy patient access, while ensuring proper
sound insulation. GENIE sound room doors are constructed
with a double magnetic gasket sealing system, heavy duty
cam-lift hinges and a compression threshold with an easy to
replace rubber seal.
• High Performance Lo Profile Floor (Hi-Lo)
Our unique Hi-Lo Floor puts the emphasis on acoustic
performance while allowing for a more natural entrance
in comparison to traditional sound room designs. Imagine
never having to worry about recessed pits or step ups again
and still maintaining adherence to local codes.
• Variable speed ventilation system
Our ventilation silencer, which includes one intake and one
outtake per room, are designed to provide increased patient
comfort while remaining whisper quiet.
• Acoustically engineered windows
Our windows are produced from double-glazed, laminated
1/4’’ (8 mm) safety glass, mounted in a heavy gauge steel
frame with rubber compression seals. The windows on the
Genie series sound room provide excellent sound insulation,
while offering a critical patient viewing experience.
• Electrical outlets
GENIE sound rooms come with both interior and exterior
electrical outlets. The electrical wiring runs inside the
acoustic wall and is connected to the outside by means of
top-mounted junction box. All components used are UL &
CE listed.
• Illuminating the experience
GENIE sound rooms are illuminated with roof mounted
state-of-the-art LED lighting systems. Dimmer switches are
standard on all rooms to give you control over the level of
lighting in the room.
• Pre-wired jack panel with cable pass through
Our pre-wired jack panel comes in a standard
configuration that contains jacks, USBs and data connections
covering all modern test equipment requirements. Jack
panels are acoustically engineered to guarantee performance
is not sacrificed for functionality.
Single wall audiometric sound rooms
Setting the clinical standard, the GENIE™ single wall audiometric exam room is constructed with our
standard 4’’ thick cam-locking wall panel design and uses 16 gauge galvanized steel (exterior skin) and
22 gauge perforated steel (interior skin) in an anti-standing wave design. Panels are filled with three
specific mineral materials for optimal attenuation across the frequency range. Pick from one of our
standard configurations below, or design your own to fit your customized needs.
Otometrics recommends a minimum 4”air gap between sound room and host wall.
Model
Number
Dimensions
Interior
Exterior
GN-11
2’9” x 3’8” x 6’6”H
(83.8 cm x 111.8 cm x 198.1 cm)
3’5” x 4’4” x 7’6”
(104.1 cm x 132.1 cm x 228.6 cm)
GN-12
3’8” x 4’5” x 6’6”H
(111.8 cm x 139.7 cm x 198.1 cm)
4’4” x 5’3” x 7’6”
(132.1 cm x 160.0 cm x 228.6 cm)
GN-12A
3’8” x 7’4” x 6’6”
(111.8 cm x 223.5 cm x 198.1 cm)
4’4” x 8’0” x 7’6”
(132.1 cm x 243.8 cm x 228.6 cm)
GN-13
4’7” x 5’6” x 6’6”
(139.7 cm x 167.6 cm x 198.1 cm)
5’3” x 6’2” x 7’6”
(160.0 cm x 188.0 cm x 228.6 cm)
GN-13A
4’7” x 7’4” x 6’6”
(139.7 cm x 223.5 cm x 198.1 cm)
5’3” x 8’0” x 7’6”
(160.0 cm x 243.8 cm x 228.6 cm)
GN-14
5’6” x 6’5” x 6’6”
(167.6 cm x 195.6 cm x 198.1 cm)
6’2” x 7’1” x 7’6”
(188.0 cm x 215.9 cm x 228.6 cm)
GN-15
6’5” x 7’4” x 6’6”
(195.6 cm x 223.5 cm x 198.1 cm)
7’1” x 8’0” x 7’6”
(215.9 cm x 243.8 cm x 228.6 cm)
GN-16
7’4” x 8’3” x 6’6”
(223.5 cm x 251.5 cm x 198.1 cm)
8’0” x 8’11” x 7’6”
(243.8 cm x 271.8 cm x 228.6 cm)
GN-17
8’3” x 9’2” x 6’6”
(251.5 cm x 279.4 cm x 198.1 cm)
8’11” x 9’10” x 7’6”
(271.8 cm x 299.7 cm x 228.6 cm)
Double wall audiometric sound rooms
When superior acoustic performance is required, consider the GENIE™ double wall audiometric exam
room as an option. The double wall sound room is comprised of a complete single wall series sound
room on the inside and a matching outer shell on the outside with walls extending down to the host
site floor. Our double wall sound room is constructed with our standard 4’’ thick cam-locking wall
panel design and uses 16 gauge galvanized steel (exterior skin) and 22 gauge perforated steel (interior
skin) in an anti-standing wave design. Panels are filled with three specific mineral materials for optimal
attenuation across the frequency range. Pick from one of our standard configurations below, or design
your own to fit your customized needs.
Otometrics recommends a minimum 4”air gap between sound room and host wall.
Model
Number
Dimensions
Interior
Exterior
GN-24
5’6” x 6’5” x 6’6”
(167.6 cm x 195.6 cm x 198.1 cm)
7’6” x 8’5” x 8’2”
(228.6 cm x 256.5 cm x 248.9 cm)
GN-25
6’5” x 7’4” x 6’6”
(195.6 cm x 223.5 cm x 198.1 cm)
8’5” x 9’4” x 8’2”
(256.5 cm x 284.5 cm x 248.9 cm)
GN-26
7’4” x 8’3” x 6’6”
(223.5 cm x 251.5 cm x 198.1 cm)
9’4” x 10’3” x 8’2”
(284.5cm x 312.4 cm x 248.9 cm)
GN-27
8’3” x 9’2” x 6’6”
(251.5 cm x 279.4 cm x 198.1 cm)
10’3” x 11’2” x 8’2”
(312.4 cm x 340.4 cm x 248.9 cm)
05
Single wall control/double wall exam
audiometric suites
The ultimate in noise controlled audiometric environments, the GENIE™
single wall control/double wall exam audiometric suite is the optimal design
when noise control is the objective for both the patient and operator. The
audiometric suite is comprised of a complete double wall examination room
on one side and an integrated single wall control room on the other. Both
sides of the suite are constructed with our standard 4’’ thick cam-locking
wall panel design and use 16 gauge galvanized steel (exterior skin) and 22
gauge perforated steel (interior skin) in an anti-standing wave design. Panels
are filled with three specific mineral materials for optimal attenuation across
the frequency range. Pick from one of our standard configurations below, or
design your own to fit your customized needs.
Otometrics recommends a minimum 4”air gap between sound room and host wall.
Model
Number
Dimensions
Control Room Interior
Exam Room Interior
Exterior
GN-121
7’4” x 5’6” x 7’9”
(223.5 cm x 167.6 cm x 236.2 cm)
6’0” x 6’8” x 6’6”
(182.9 cm x 203.2 cm x 198.1 cm)
8’0” x 14’6” x 8’2”
(243.8 cm x 442.0 cm x 248.9 cm)
GN-122
6’5” x 8’3” x 7’9”
(195.6 cm x 251.5 cm x 236.2 cm)
6’11” x 7’7” x 6’6”
(210.8 cm x 231.1 cm x 198.1 cm)
8’11” x 16’4” x 8’2”
(271.8 cm x 497.0 cm x 248.9 cm)
GN-123
9’2” x 7’4” x 7’9”
(279.4 cm x 223.5 cm x 236.2 cm)
7’10” x 8’6” x 6’6”
(238.8 cm x 259.1 cm x 198.1 cm)
9’10” x 18’2” x 8’2”
(299.7 cm x 553.7 cm x 248.9 cm)
GN-124
10’1” x 8’3” x 7’9”
(307.3 cm x 251.5 cm x 236.2 cm)
8’9” x 9’5” x 6’6”
(266.7 cm x 287.0 cm x 198.1 cm)
10’9” x 20’0” x 8’2”
(327.7 cm x 609.6 cm x 248.9 cm)
Single wall audiometric screening
rooms
Cost and efficiency are a priority for every business. The GENIE™ single wall
audiometric screening room is always ready to step in and help. Available in
either a right-hinged or a left-hinged model, the single wall screening room is
constructed with our specialized 3’’ thick cam-locking wall panel design and
uses 16 gauge galvanized steel (exterior skin) and 22 gauge perforated steel
(interior skin) in an anti-standing wave design. Panels are filled with three
specific mineral materials for optimal attenuation across the frequency range.
Each “mini-booth” comes standard with wheels (or natural rubber isolators),
an audiometric shelf and a standard mini-jack panel.
Otometrics recommends a minimum 4” air gap between sound room and host wall.
Right Hinged booth shown.
Dimensions
Model
Number
Interior
Exterior
GN-300
Right Hinged
2’1” x 2’11” x 5’5 ¾”
(63.5 cm x 88.9 cm x 167.0 cm)
2’7” x 3’5” x 6’4”
(78.7 cm x 104.1 cm x 193.0 cm)
GN-300
Left Hinged
2’1” x 2’11” x 5’5 ¾”
(63.5 cm x 88.9 cm x 167.0 cm)
2’7” x 3’5” x 6’4”
(78.7 cm x 104.1 cm x 193.0 cm)
Single wall space efficiency sound
rooms
Looking to save a little space in your office? Consider the GENIE™ single
wall space efficiency exam room as an alternative. The single wall room is
constructed from our standard 4’’ thick cam-locking wall panel design and
uses 16 gauge galvanized steel (exterior skin) and 22 gauge perforated steel
(interior skin) in an anti-standing wave design. Panels are filled with three
specific mineral materials for optimal attenuation across the frequency range.
This design optimizes external office space without sacrificing the high clinical
standards inside the sound room.
Otometrics recommends a minimum 4” air gap between sound room and host wall.
Model
Number
Dimensions
Interior
Exterior
GN-66
6’6” x 6’6” x 6’6”
(198.1 cm x 198.1 cm x 198.1 cm)
7’2” x 7’2” x 7’6”
(218.4 cm x 218.4 cm x 228.6 cm)
GN-86
6’6” x 8’6” x 6’6”
(198.1 cm x 259.1 cm x 198.1 cm)
7’2” x 9’2” x 7’6”
(218.4 cm x 279.4 cm x 228.6 cm)
Single wall control/single wall exam
audiometric suites
When you need a noise control solution for both patient and operator but a
restrictive host site doesn’t allow the space for a double wall suite, the GENIE™
single wall control/single wall exam audiometric suite will provide optimal
noise control with manageable space requirements. The audiometric suite
is comprised of two single wall examination rooms aligned and matched to
create an inviting and sound-secured testing environment. Both sides of the
suite are constructed with our standard 4’’ thick cam-locking wall panel design
and use 16 gauge galvanized steel (exterior skin) and 22 gauge perforated
steel (interior skin) in an anti-standing wave design. Panels are filled with three
specific mineral materials for optimal attenuation across the frequency range.
Pick from one of our standard configurations below, or design your own to fit
your customized needs.
Otometrics recommends a minimum 4” air gap between sound room and host wall.
Model
Number
Dimensions
Control Room Interior
Exam Room Interior
Exterior
GN-34
5’6” x 4’7” x 7’6”
(167.6 cm x 139.7 cm x 198.1 cm)
5’6” x 6’5” x 7’11”
(167.6 cm x 195.6 cm x 241.3 cm)
6’2” x 12’8” x 7’6”
(188.0 cm x 386.1 cm x 228.6 cm)
GN-45
6’5” x 5’6” x 6’6”
(195.6 cm x 167.6 cm x 198.1 cm)
6’5” x 7’4” x 7’11”
(195.6 cm x 223.5 cm x 241.3 cm)
7’1” x 12’8” x 7’6”
(215.9 cm x 442.9 cm x 228.6 cm)
GN-56
7’4” x 6’5” x 6’6”
(223.5 cm x 195.6 cm x 198.1 cm)
7’4” x 8’3” x 7’11”
(223.5 cm x 251.5 cm x 241.3 cm)
8’0” x 14’6” x 7’6”
(215.9 cm x 497.8 cm x 228.6 cm)
GN-67
8’3” x 7’4” x 6’6”
(251.5 cm x 223.5 cm x 198.1 cm)
8’3” x 9’2” x 7’11”
(251.5 cm x 279.4 cm x 241.3 cm)
8’11” x 18’2” x 7’6”
(271.8 cm x 553.7 cm x 228.6 cm)
07
Design the sound room that fits your space best
About Otometrics
Otometrics is the audiology industry leader providing instrumentation
and software solutions to hearing and balance care professionals
worldwide. For more than 50 years, Otometrics has been helping hearing
and balance care professionals succeed in improving the quality of life
for their clients and patients around the world by delivering expert
knowledge, reliable solutions and trusted partnership.
Otometrics develops, manufactures and markets computer-based
audiological, otoneurologic and vestibular instrumentation in more than
85 countries under the MADSEN®, AURICAL®, HORTMANN® and ICS® brand
names. Otometrics is part of the GN Group, one of the largest companies
in Denmark. For more information, please visit www.otometrics.com.
GN Otometrics, Headquarters. +45 45 75 55 55. [email protected]
GN Otometrics, North America. 1-800-289-2150. [email protected]
www.otometrics.com
Specifications are subject to change without notice. Copyright © GN Otometrics. 2015/03. 7-26-1911-EN/00. Part no. 7-26-19101-EN.