Audiometric sound rooms View our portfolio of sound room www.otometrics.com/soundrooms GENIE™ Audiometric sound rooms The GENIE™ series of audiometric sound rooms has provided state-of-the-art performance and quality since 2001. Over the years, feedback from customers and patients, audiologists, acousticians and engineers has been used to optimize the design of the product. The GENIE sound room is a solution infused with science and uncompromising dedication to customer needs. Customized to your needs GENIE sound rooms are fully customizable. We offer a diverse audiometric product line ranging from double wall exam suites for optimal noise management to small occupational health mobile rooms. If a standard size room doesn’t fit your needs, we customize it to make the most of your available space. GENIE sound rooms have a variety of configurable options, features and accessories and offer a variety of trims and finishes. A wide range of colors and interior design packages are available to match any decor. Simply select a size, configuration, and feature package that works best for your new clinic. Equipment integration The GENIE series is a state-of-the-art audiometric sound room solution. It integrates perfectly with any equipment in your clinic. This integration allows you to provide exceptional patient care in a controlled environment today, and adapts to the technologies you will be using in the future. Our experienced sales staff builds your sound room according to how you want to use your equipment. We help you integrate your audiometric equipment with your new noise controlled space. Integrated instrumentation results in an optimized workflow and a superior patient experience in a controlled acoustic environment. End-to-end solution Whether you are designing a new clinic or adding to your existing space, we guide you every step of the way. Our extensive audiology experience and consultative approach ensure a seamless experience for you in sound room design, delivery and installation. Otometrics sound room division sales engineers and our local partners work closely with you throughout the entire process. Each sound room comes with professional project management and complete installation. All of our sales engineers and installation teams are factory trained, evaluated and certified for quality assurance. 03 GENIE™ sound rooms have a variety of configurable options, features and accessories and offer a variety of trims and finishes. A wide range of colors and interior design packages are available to match any decor. • Acoustically engineered doors Our doors provide easy patient access, while ensuring proper sound insulation. GENIE sound room doors are constructed with a double magnetic gasket sealing system, heavy duty cam-lift hinges and a compression threshold with an easy to replace rubber seal. • High Performance Lo Profile Floor (Hi-Lo) Our unique Hi-Lo Floor puts the emphasis on acoustic performance while allowing for a more natural entrance in comparison to traditional sound room designs. Imagine never having to worry about recessed pits or step ups again and still maintaining adherence to local codes. • Variable speed ventilation system Our ventilation silencer, which includes one intake and one outtake per room, are designed to provide increased patient comfort while remaining whisper quiet. • Acoustically engineered windows Our windows are produced from double-glazed, laminated 1/4’’ (8 mm) safety glass, mounted in a heavy gauge steel frame with rubber compression seals. The windows on the Genie series sound room provide excellent sound insulation, while offering a critical patient viewing experience. • Electrical outlets GENIE sound rooms come with both interior and exterior electrical outlets. The electrical wiring runs inside the acoustic wall and is connected to the outside by means of top-mounted junction box. All components used are UL & CE listed. • Illuminating the experience GENIE sound rooms are illuminated with roof mounted state-of-the-art LED lighting systems. Dimmer switches are standard on all rooms to give you control over the level of lighting in the room. • Pre-wired jack panel with cable pass through Our pre-wired jack panel comes in a standard configuration that contains jacks, USBs and data connections covering all modern test equipment requirements. Jack panels are acoustically engineered to guarantee performance is not sacrificed for functionality. Single wall audiometric sound rooms Setting the clinical standard, the GENIE™ single wall audiometric exam room is constructed with our standard 4’’ thick cam-locking wall panel design and uses 16 gauge galvanized steel (exterior skin) and 22 gauge perforated steel (interior skin) in an anti-standing wave design. Panels are filled with three specific mineral materials for optimal attenuation across the frequency range. Pick from one of our standard configurations below, or design your own to fit your customized needs. Otometrics recommends a minimum 4”air gap between sound room and host wall. Model Number Dimensions Interior Exterior GN-11 2’9” x 3’8” x 6’6”H (83.8 cm x 111.8 cm x 198.1 cm) 3’5” x 4’4” x 7’6” (104.1 cm x 132.1 cm x 228.6 cm) GN-12 3’8” x 4’5” x 6’6”H (111.8 cm x 139.7 cm x 198.1 cm) 4’4” x 5’3” x 7’6” (132.1 cm x 160.0 cm x 228.6 cm) GN-12A 3’8” x 7’4” x 6’6” (111.8 cm x 223.5 cm x 198.1 cm) 4’4” x 8’0” x 7’6” (132.1 cm x 243.8 cm x 228.6 cm) GN-13 4’7” x 5’6” x 6’6” (139.7 cm x 167.6 cm x 198.1 cm) 5’3” x 6’2” x 7’6” (160.0 cm x 188.0 cm x 228.6 cm) GN-13A 4’7” x 7’4” x 6’6” (139.7 cm x 223.5 cm x 198.1 cm) 5’3” x 8’0” x 7’6” (160.0 cm x 243.8 cm x 228.6 cm) GN-14 5’6” x 6’5” x 6’6” (167.6 cm x 195.6 cm x 198.1 cm) 6’2” x 7’1” x 7’6” (188.0 cm x 215.9 cm x 228.6 cm) GN-15 6’5” x 7’4” x 6’6” (195.6 cm x 223.5 cm x 198.1 cm) 7’1” x 8’0” x 7’6” (215.9 cm x 243.8 cm x 228.6 cm) GN-16 7’4” x 8’3” x 6’6” (223.5 cm x 251.5 cm x 198.1 cm) 8’0” x 8’11” x 7’6” (243.8 cm x 271.8 cm x 228.6 cm) GN-17 8’3” x 9’2” x 6’6” (251.5 cm x 279.4 cm x 198.1 cm) 8’11” x 9’10” x 7’6” (271.8 cm x 299.7 cm x 228.6 cm) Double wall audiometric sound rooms When superior acoustic performance is required, consider the GENIE™ double wall audiometric exam room as an option. The double wall sound room is comprised of a complete single wall series sound room on the inside and a matching outer shell on the outside with walls extending down to the host site floor. Our double wall sound room is constructed with our standard 4’’ thick cam-locking wall panel design and uses 16 gauge galvanized steel (exterior skin) and 22 gauge perforated steel (interior skin) in an anti-standing wave design. Panels are filled with three specific mineral materials for optimal attenuation across the frequency range. Pick from one of our standard configurations below, or design your own to fit your customized needs. Otometrics recommends a minimum 4”air gap between sound room and host wall. Model Number Dimensions Interior Exterior GN-24 5’6” x 6’5” x 6’6” (167.6 cm x 195.6 cm x 198.1 cm) 7’6” x 8’5” x 8’2” (228.6 cm x 256.5 cm x 248.9 cm) GN-25 6’5” x 7’4” x 6’6” (195.6 cm x 223.5 cm x 198.1 cm) 8’5” x 9’4” x 8’2” (256.5 cm x 284.5 cm x 248.9 cm) GN-26 7’4” x 8’3” x 6’6” (223.5 cm x 251.5 cm x 198.1 cm) 9’4” x 10’3” x 8’2” (284.5cm x 312.4 cm x 248.9 cm) GN-27 8’3” x 9’2” x 6’6” (251.5 cm x 279.4 cm x 198.1 cm) 10’3” x 11’2” x 8’2” (312.4 cm x 340.4 cm x 248.9 cm) 05 Single wall control/double wall exam audiometric suites The ultimate in noise controlled audiometric environments, the GENIE™ single wall control/double wall exam audiometric suite is the optimal design when noise control is the objective for both the patient and operator. The audiometric suite is comprised of a complete double wall examination room on one side and an integrated single wall control room on the other. Both sides of the suite are constructed with our standard 4’’ thick cam-locking wall panel design and use 16 gauge galvanized steel (exterior skin) and 22 gauge perforated steel (interior skin) in an anti-standing wave design. Panels are filled with three specific mineral materials for optimal attenuation across the frequency range. Pick from one of our standard configurations below, or design your own to fit your customized needs. Otometrics recommends a minimum 4”air gap between sound room and host wall. Model Number Dimensions Control Room Interior Exam Room Interior Exterior GN-121 7’4” x 5’6” x 7’9” (223.5 cm x 167.6 cm x 236.2 cm) 6’0” x 6’8” x 6’6” (182.9 cm x 203.2 cm x 198.1 cm) 8’0” x 14’6” x 8’2” (243.8 cm x 442.0 cm x 248.9 cm) GN-122 6’5” x 8’3” x 7’9” (195.6 cm x 251.5 cm x 236.2 cm) 6’11” x 7’7” x 6’6” (210.8 cm x 231.1 cm x 198.1 cm) 8’11” x 16’4” x 8’2” (271.8 cm x 497.0 cm x 248.9 cm) GN-123 9’2” x 7’4” x 7’9” (279.4 cm x 223.5 cm x 236.2 cm) 7’10” x 8’6” x 6’6” (238.8 cm x 259.1 cm x 198.1 cm) 9’10” x 18’2” x 8’2” (299.7 cm x 553.7 cm x 248.9 cm) GN-124 10’1” x 8’3” x 7’9” (307.3 cm x 251.5 cm x 236.2 cm) 8’9” x 9’5” x 6’6” (266.7 cm x 287.0 cm x 198.1 cm) 10’9” x 20’0” x 8’2” (327.7 cm x 609.6 cm x 248.9 cm) Single wall audiometric screening rooms Cost and efficiency are a priority for every business. The GENIE™ single wall audiometric screening room is always ready to step in and help. Available in either a right-hinged or a left-hinged model, the single wall screening room is constructed with our specialized 3’’ thick cam-locking wall panel design and uses 16 gauge galvanized steel (exterior skin) and 22 gauge perforated steel (interior skin) in an anti-standing wave design. Panels are filled with three specific mineral materials for optimal attenuation across the frequency range. Each “mini-booth” comes standard with wheels (or natural rubber isolators), an audiometric shelf and a standard mini-jack panel. Otometrics recommends a minimum 4” air gap between sound room and host wall. Right Hinged booth shown. Dimensions Model Number Interior Exterior GN-300 Right Hinged 2’1” x 2’11” x 5’5 ¾” (63.5 cm x 88.9 cm x 167.0 cm) 2’7” x 3’5” x 6’4” (78.7 cm x 104.1 cm x 193.0 cm) GN-300 Left Hinged 2’1” x 2’11” x 5’5 ¾” (63.5 cm x 88.9 cm x 167.0 cm) 2’7” x 3’5” x 6’4” (78.7 cm x 104.1 cm x 193.0 cm) Single wall space efficiency sound rooms Looking to save a little space in your office? Consider the GENIE™ single wall space efficiency exam room as an alternative. The single wall room is constructed from our standard 4’’ thick cam-locking wall panel design and uses 16 gauge galvanized steel (exterior skin) and 22 gauge perforated steel (interior skin) in an anti-standing wave design. Panels are filled with three specific mineral materials for optimal attenuation across the frequency range. This design optimizes external office space without sacrificing the high clinical standards inside the sound room. Otometrics recommends a minimum 4” air gap between sound room and host wall. Model Number Dimensions Interior Exterior GN-66 6’6” x 6’6” x 6’6” (198.1 cm x 198.1 cm x 198.1 cm) 7’2” x 7’2” x 7’6” (218.4 cm x 218.4 cm x 228.6 cm) GN-86 6’6” x 8’6” x 6’6” (198.1 cm x 259.1 cm x 198.1 cm) 7’2” x 9’2” x 7’6” (218.4 cm x 279.4 cm x 228.6 cm) Single wall control/single wall exam audiometric suites When you need a noise control solution for both patient and operator but a restrictive host site doesn’t allow the space for a double wall suite, the GENIE™ single wall control/single wall exam audiometric suite will provide optimal noise control with manageable space requirements. The audiometric suite is comprised of two single wall examination rooms aligned and matched to create an inviting and sound-secured testing environment. Both sides of the suite are constructed with our standard 4’’ thick cam-locking wall panel design and use 16 gauge galvanized steel (exterior skin) and 22 gauge perforated steel (interior skin) in an anti-standing wave design. Panels are filled with three specific mineral materials for optimal attenuation across the frequency range. Pick from one of our standard configurations below, or design your own to fit your customized needs. Otometrics recommends a minimum 4” air gap between sound room and host wall. Model Number Dimensions Control Room Interior Exam Room Interior Exterior GN-34 5’6” x 4’7” x 7’6” (167.6 cm x 139.7 cm x 198.1 cm) 5’6” x 6’5” x 7’11” (167.6 cm x 195.6 cm x 241.3 cm) 6’2” x 12’8” x 7’6” (188.0 cm x 386.1 cm x 228.6 cm) GN-45 6’5” x 5’6” x 6’6” (195.6 cm x 167.6 cm x 198.1 cm) 6’5” x 7’4” x 7’11” (195.6 cm x 223.5 cm x 241.3 cm) 7’1” x 12’8” x 7’6” (215.9 cm x 442.9 cm x 228.6 cm) GN-56 7’4” x 6’5” x 6’6” (223.5 cm x 195.6 cm x 198.1 cm) 7’4” x 8’3” x 7’11” (223.5 cm x 251.5 cm x 241.3 cm) 8’0” x 14’6” x 7’6” (215.9 cm x 497.8 cm x 228.6 cm) GN-67 8’3” x 7’4” x 6’6” (251.5 cm x 223.5 cm x 198.1 cm) 8’3” x 9’2” x 7’11” (251.5 cm x 279.4 cm x 241.3 cm) 8’11” x 18’2” x 7’6” (271.8 cm x 553.7 cm x 228.6 cm) 07 Design the sound room that fits your space best About Otometrics Otometrics is the audiology industry leader providing instrumentation and software solutions to hearing and balance care professionals worldwide. For more than 50 years, Otometrics has been helping hearing and balance care professionals succeed in improving the quality of life for their clients and patients around the world by delivering expert knowledge, reliable solutions and trusted partnership. Otometrics develops, manufactures and markets computer-based audiological, otoneurologic and vestibular instrumentation in more than 85 countries under the MADSEN®, AURICAL®, HORTMANN® and ICS® brand names. Otometrics is part of the GN Group, one of the largest companies in Denmark. For more information, please visit www.otometrics.com. GN Otometrics, Headquarters. +45 45 75 55 55. [email protected] GN Otometrics, North America. 1-800-289-2150. [email protected] www.otometrics.com Specifications are subject to change without notice. Copyright © GN Otometrics. 2015/03. 7-26-1911-EN/00. Part no. 7-26-19101-EN. Simply use the below grid to customize what you would like your sound room to look like.
© Copyright 2026 Paperzz