| Force | Pressure | Temperature | Switch Electronical pressure switch MagSwitch One ore two adjustable switching outputs or One adjustable switching output with adjustable hysteresis Discription Features The compact electronic pressure switch MagSwitch provides pressure monitoring. Adjusting screws are used to set the switching point under pressure. Integrated LEDs indicate the current switching state. The principle of nonimpact measurement based on the Hall-effect ensures a pressure switch with high level of repeatability and durability, even in case of a high number pressure cycles. O non - contact measurement O long - life cycle O very good repeatability O one or two switching outputs O simple adjustment of the set points O status LED indication The contact functions (normally open / normally closed) and the contact types (p-switching / n-switching) are available as optional extras. Switching currents ranging from a few micro amps to 100 mA allow the MagSwitch to be easily integrated into almost any control system. The adjustable hysteresis enables to build up 2 point controllers easily without any additional external components. A pressure connection free of elastomers qualifies the MagSwitch for many liquid and gaseous media. The metal diaphragm can also be used without any problem for simultaneously occurring pressure and vacuum. O compact design O pressure connection in brass O p- or n-switching Measuring ranges O positive adjustment ranges from 0.005 up to 600 bar O vacuum ranges up to -900 mbar Applications O mechanical engineering O vacuum technology O refrigeration technology O filter monitoring O level measurement O building technology Model: S1100, S1200 tecsis GmbH Carl-Legien Str. 40-44 D-63073 Offenbach / Main Tel.: +49(0) 69 / 5806-0 Sales National Fax: +49(0) 69 / 5806-7788 Sales International Fax: +49(0) 69 / 5806-7788 e-Mail: [email protected] Internet: www.tecsis.de DE 740 k 03/2014 p. 1 / 4 -0.1 … 0 -0.16 … 0 -0.25 … 0 -0.4 … 0 -0.6 … 0 -0.9 … 0 S1100 S1200 0 ... 0.1 0 ... 0.16 0 ... 0.25 0 ... 0.4 0 ... 0.6 0 ... 1 0 ... 1.6 0 ... 2.5 0 ... 4 0 ... 6 0 ... 10 0 ... 16 0 ... 25 0 … 40 0 ... 60 0 ... 100 0 ... 160 0 ... 250 0 ... 400 0 ... 600 Reset point [bar] increasing pressure decreasing pressure Negative overpressure -0.095…0 -0.1 …-0.005 -0.152 ...0 -0.16…-0.008 -0.237 ...0 -0.25…-0.013 -0.38 ...0 -0.4 …-0.020 -0.57 ...0 -0.6 …-0.030 -0.85 ...0 -0.9 …-0.050 postive gauge pressure 0.005…0.1 0 ... 0.0995 0.008…0.16 0 ... 0.152 0.013…0.25 0 ... 0.237 0.02 ... 0.4 0 ... 0.38 0.03 … 0.6 0 ... 0.57 0.05… 1 0 ... 0.95 0.08… 1.6 0 ... 1.52 0.13… 2.5 0 ... 2.37 0.2 … 4 0 ... 3.8 0.3 … 6 0 ... 5.7 0.5 … 10 0 ... 9.5 1.6 … 16 0 ... 14.4 2.5 … 25 0 ... 22.5 2 … 40 0 … 38 3 … 60 0 … 57 5 ... 100 0 ... 95 8 ... 160 0 ... 152 13 ... 250 0 ... 237 20 ... 400 0 ... 380 30 ... 600 0 ... 570 5 5 5 5 5 5 0.4 0.6 1.0 1.6 2.4 4.0 4 6 10 16 24 40 5 5 5 5 5 5 5 5 5 5 5 10 10 5 5 5 5 5 5 5 0.4 0.6 1.0 1.6 2.4 4.0 6.0 10 16 24 30 32 40 80 120 200 320 500 800 1000 4 6 10 16 24 40 60 100 160 240 300 320 400 120 180 300 480 750 1200 1500 Sensor element Switching point [bar] Burst pressure [bar] Adjustment range [bar] Overrange limit [bar] Model Hysteresis [%] Adjustment ranges Diaphragm Bourdon tube The contact switches when the switching point is reached. The hysteresis determines the switch back point. The switching point can be modified within the adjustment range. Both the switching point and the switch back point have to be within the adjustment range. If there are several pressure cycles, all switching points are within the specified reproducibility. Dynamic loads up to the overload limit may be applied to the pressure switches. If the overload limit is exceeded, the pressure switch will be damaged. If the burst pressure is exceeded, even for short periods, the pressure switch will be destroyed. DE 740 k p. 2 / 4 Technical data Model Execution Pressure type Standard Optional Pressure connection Standard Optional Measuring principle Materials Measuring element Pressure connection Housing Electronic insert Load cycles Supply voltage Power consumption Switching outputs Number Switching function Standard Optional Power rating Adjustment Set point Hysteresis Standard Optional Accuracy Repeatability Temperature ranges Storage Media Ambient Temperature compensated range Temperature influence Electrical connection Protection class CE Electrical protection Weight S1100 Diaphragm S1200 Bourdon tube Positive or negative gauge pressure Positive and negative gauge pressure G1/4 B G1/8 B, 1/4NPT, 1/2NPT, only S1200: flange type Hall - effect Ni - and Cu - alloy Brass Brass Plastic 1 million pressure cycles 10 ... 30 V DC ≤ 25 mA (without load current) Stainless steel Brass Anodized aluminium Plastic 1 or 2 separately adjustable or 1 switching point with adjustable hyteresis Normally open, normally close p - switching n - switching 0.1 A Locally by adjustment screw (0) 5 ... 100 % of full scale ≤ 5 % of full scale For adjustment ranges 16 and 25 bar: ≤ 10 % of full scale Adjustable hysteresis: 5 … 95 % of full scale 1 % of full scale (limit point calibration) 1 % of full scale -30 ... + 80 °C -20 ... + 80 °C -20 ... + 70 °C 0 ... + 80 °C + 0.4 % of full scale per 10 K Round connector M12x1; 4 - pin IP65 Emission and interference acc. to EN 61 326 Over voltage protection Approx. 0.09 kg Approx. 0.27 kg DE 740 k p. 3 / 4 Dimensions [mm] Model S1100: S1200: Flange type Model S1200: Electrical connections Round connector M12 x 1 (4-pin) p-switching p-switching 1 switching output n-switching 2 switching outputs n-switching Connection for plug and cable outlet Signal Pin Cable outlet Supply: UB 1 Brown Supply: 0V 3 Blue Switching output: S 1 4 Black Switching output: S 2 2 White We recommend our accessories: M12x1 cable socket with 2 m wire Straight version, order no.: EZE53X011010 Angled version, order no.: EZE53X011011 Subject to technical alterations DE 740 k p. 4 / 4
© Copyright 2026 Paperzz