6113 EDGE Base Station Test Set GSM I & C testing July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test What is the 6113? • GSM, GPRS and EDGE BTS tester • Verifies base station installation and commissioning • Provides maintenance/fault-finding capability • Verifies performance to GSM recommendations (11.21) • Independent evaluation of BTS RF performance July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test 6113 - Digital Radio Test Set • Supports GSM 850, 900, 1800 and 1900 frequency bands • Options to control & test ALL BTS types • Test sequences for full customization • Optimized for installation and commissioning, routine maintenance, fault finding and production testing • A-bis interface for FULL BTS control and bit error ratio (BER) measurements July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test 6113 Customers • • • • • • • • • • • • • • • • Airtel/Bharti, India Airnet Alcatel AT&T Wireless, USA Austrian PTT Belgacom, Belgium Bell Canada Bell South, New Zealand Birla/AT&T Comm, India China Mobile China Unicom Cingular Wireless, USA Digi, Malaysia DST, Brunei E-Plus, Germany Ericsson July 2004 6113 Customer.ppt • • • • • • • • • • • • • • • • • Eurotel, Czech Republic Eurotel, Hungary Interwave Italtel Macau PTT Mannesman Microcell Motorola Nederlands PTT Nokia Nortel Nortel Matra O2, UK Orbitel PKI (Lucent) Siemens Livingston Hire • • • • • • • • • • • • • • • • • Locamesure Omnitel, Italy Optus, Australia Orange, UK Orange, France Panavox, Greece PCCW Hong Kong People’s Telephone, HK Radiolinja, Finland Renault SC&C Thailand Sonofon, Denmark SmarTone HK Telecom Australia Telecom Eireann Telecom Finland Telecom Italia Mobile Commercial in Confidence • • • • • • • • • • • • • Telecom Americas, Brazil TeleDanmark Mobil, Denmark Telia Mobile, Sweden Telenor, Norway TIM, Brazil TIM, Chile T-Mobile UK T-Mobile USA Total Access Communication, Thailand Vodafone, Fiji Vodafone, Ireland Vodafone, UK Westel, Hungary 6113 Base Station Test Front View of the 6113 SoftKeys Spin Wheel RACAL INSTRUMENTS 6113E Digital Radio Test Set Enter 6113 PCS1900 POWER CONTRAST 1 2 3 4 5 6 7 8 9 +/- 0 . RF Out Key Pad RF In/Duplex MEMORY CARD PCMCIA A-bis Connections RF Out - RF In/Duplex - TNC female N-type female BNC or Banana July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Rear View of the 6113 Freq Ref Connections 10R Encryption Module July 2004 6113 Customer.ppt BOSS RF IN/Duplex (SMA female) & BOSS RF OUT(TNC female) Commercial in Confidence 6113 Base Station Test Maximum/Minimum Power Levels Input Front Panel Simplex Output Duplex Input Rear Panel July 2004 6113 Customer.ppt Simplex Output Duplex Minimum 0dBm -120dBm -120dBm Maximum 47dBm -40dBm +47dBm Minimum -50dBm -100dBm -100dBm Maximum 0dBm -20dBm +20dBm Commercial in Confidence 6113 Base Station Test 6113 Emulation Capability • Standard A-bis closed loop control • Cell Integrity Test / Analysis • Live Testing (Non Intrusive) July 2004 6113 Customer.ppt Commercial in Confidence 6113 BSC mobile BSC 6113 6113 mobile 6113 Base Station Test 6113 Test Capability Functional Transmitter Receiver A-bis link tests Cell control channel Bit error ratio (BER) Code download Bit error ratio (BER) Block error ratio (BLER) Configure BTS Block Error (BLER) TCH Absolute sensitivity Reset BTS Power RACH sensitivity Special functions Power Steps Rx level Power profile Rx quality Phase error Encryption Frequency error Modulation spectrum July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Abis Controlled Main Menu Parameters Main Menu 14 DEC 2003 14:12:44 Information 6113 Offsets Results Live Tests Special Functions A-bis File Controlled Manager PCS 1900 Self Tests / Tests Test Sequences System T.A. : GPIB : 20 July 2004 6113 Customer.ppt BTS RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On 6113 Base Station Test A-bis Controlled Testing BTS RF A-bis 61 13 61 • A-bis control software for different BTS manufacturers make product unique • Base station can be tested prior to connection to network 13 6113 July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Simulation • Automatic Simulation of Mobile • Layer 1 - RF • Layer 2 - LAPDm • Layer 3 - Call Processing as required • Automatic Simulation of BSC • Layer 1 - G 703/704 • Layer 2 - LAPD • Layer 3 - O & M - Manufacturer Specific and 08-58 July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Setup of 6113 for Abis Controlled Testing Setting Up The 6113 manually • BTS information • • • • • • • BTS manufacturer BTS model BTS s/w version BTS code path Mapping Table Interface RF connection • Enter an offset for RF losses • Write & save a parameter file • Setup results file July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test BTS Information A-bis Settings BTS Information 14 DEC 1995 Mapping 14:12:44 BTS Manufacturer BTS type Table Radio System : PCS 1900 Interface BTS Model BTS Manufacturer : Nokia Balanced BTS Model : RF Connect Radio System Ultrasite BTS Software Version : PU1 BTS Software Code Path : A:\ BTS Software Duplex BTS S/W Code Path T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXLEV: Std: 10 MHz RXQUAL: Results: Off Commercial in Confidence Offsets : On Exit 6113 Base Station Test RF Offsets Parameters Main Menu 14 DEC 1995 14:12:44 BTS Information 6113 Offsets Results Live Tests Special Functions File A-bis Manager Controlled PCS 1900 Self Tests / Test Sequences System T.A. : GPIB : 20 July 2004 6113 Customer.ppt Tests RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On 6113 Base Station Test Entering Offsets Results 14 NOV 1996 Parameter Cancel All 14:12:44 Edit parameter Value Default Level Offsets Off Off BTS Transmit Offset 0.00 0.00 dB BTS Receive Offset 0.00 0.00 dB Reset All Allowed List: Off, On (A negative value specifies loss in path) T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : Off EXIT 6113 Base Station Test Mapping Table • Define Abis Timeslot usage • Define TRXs in BTS Cabinet • Define Signalling and Traffic slots July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Parameter Files Parameters Main Menu 14 DEC 1995 14:12:44 Information 6113 Offsets Results Live Tests Special Functions A-bis File Controlled Manager PCS 1900 Self Tests / Tests Test Sequences System T.A. : GPIB : 20 July 2004 6113 Customer.ppt BTS RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On 6113 Base Station Test Read / Write Read File Parameters 14 DEC 1995 14:12:44 Write File GSM Parameters Timing Output Port T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On EXIT 6113 Base Station Test Writing a parameter file Memory Card A: Parameters 14 DEC 1995 14:12:44 Edit Filename Enter Parameter File to Write File Name: Directory: Description: TEST 2 Accept .PRM List Files A:\TESTS\BTS List Directories Parameter file for TEST BTS 2 Edit File Description T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On Cancel 6113 Base Station Test Test Results Display/Logging Parameters Main Menu 14 DEC 1995 14:12:44 6113 Offsets Results Live Tests Special Functions A-bis Controlled Tests File Manager PCS 1900 Self Tests / Test Sequences System T.A. : GPIB : 20 July 2004 6113 Customer.ppt BTS Information RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On 6113 Base Station Test Results Screen Results 14 DEC 1995 14:12:44 Results BTS Serial Number(s) Off Test Results Header Operator BTS Serial Number(s) Remarks Configure Printer 777 Operator John Doe Remarks ACU not working Print Header Print Footer T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On EXIT 6113 Base Station Test A-bis Control Testing • Three Test Modes • Single Test Mode • Test Sequences • Multimode July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Single Test Single Tests • Manual control of all parameters • PASS / FAIL and full results • Test can be repeated • Graphic screens if applicable • Results printout July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test GSM - Transmitter Tests July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test GSM A-bis Receiver Tests July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Receiver BER Parameter July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Receiver Bit Error Ratio A-bis interface Receive BTS Receiver 6113 RF interface Transmit • Known Bit Pattern sent to BTS • Monitor Bit Pattern on Abis TRAU/PCU frames on A-bis Interface • Identify Class Ib, Class II bits, FER • Available on Transmitter BTS Control Mode July 2004 6113 Customer.ppt Commercial in Confidence • Available Signalling Channels 6113 Base Station Test Receiver BER test result July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Sequences Test Sequence Generation Parameters Main Menu 14 DEC 1995 14:12:44 Information 6113 Offsets Results Live Tests Special Functions A-bis File Controlled Manager PCS 1900 Self Tests / Tests Test Sequences System T.A. : GPIB : 20 July 2004 6113 Customer.ppt BTS RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On 6113 Base Station Test Auto Test Sequences • Repeatable List of Tests • Easy-to-use Front panel ‘learn’ mode • Ability to Change all test parameters • Tests can be programmed using RIBASIC • Continue/Pause/Exit on Pass/Fail • Full and summary results printout • Seq/Results Stored on memory card July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Defining a sequence Parameters Define Sequence BTS Information 8 DEC 1995 14:07:49 Select Functional Tests Receiver BER Absolute Sensitivity Transmitter Tests RACH Test RX Level RX Quality T.A. : Select inRXLEV: order each test you want RXQUAL: GPIB : 20 July 2004 6113 Customer.ppt Receiver Tests Std: 10 MHz Results: Off Commercial in Confidence Offsets : On EXIT 6113 Base Station Test End of test action (each test) Define Sequence : End of Test Actions Parameter Value Test Passed Test Failed Print Results Condition Cancel All 14 DEC 1995 14:12:44 Edit Parameter Default Hold Repeat Both Continue Hold Both Allowed List : Continue, Hold, Exit, Repeat Select Action on Test Return Value Reset All T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On EXIT 6113 Base Station Test Running a sequence Load Sequence Sequence 9 DEC 1995 12:21:22 Define Sequence Repeat TESTSEQ1 T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On EXIT 6113 Base Station Test Sequence summary 12 DEC 1995 15:29:36 Results Summary : A:\JOB3.SEQ Overall Result FAIL Timeslot Test Channel 1 Configure BTS 2 Receiver BER 3 RACH Test T.A. : GPIB : 20 July 2004 6113 Customer.ppt Print Results - - 90 90 4 - X X RXQUAL: RXLEV: Std: 10 MHz Pass Results: Off Commercial in Confidence Offsets : On EXIT 6113 Base Station Test Editing a sequence • Cannot use the 6113. • Use a text editor on the PC SET EOTACTION ON, CONTINUE, ON, HOLD ! Step Number 2 - TEST Transmitter Test TEST TXTST 512, 0, 0, -85.0, 10, 1, 1, 0, 0, 0, 95.0, 5.00, 20.00, +42.0, 3.0, 1.0, 1 July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Sequence Basics • First two lines are special: • [Line 1]<Code version> - <Date> • [Line 2] File description • ! Comment • Keywords • Variable names • loops July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Multimode Multimode • Continuous real time readings • Graphics for easy diagnosis • Simple/Dynamic control of settings • Out of limits readings highlighted • Intermittent Fault Finding • Fault Isolation July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Multimode Results • • • • • • • Pass/Fail Samples/Events/Ratio for FER, Class lb and Class II. Phase Error (graph) Frequency Error BTS Power Power Profile (graph) Modulation Spectrum (graph). July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Multimode Power Profile Test Information Multimode : Power Profile 6 DEC 1995 15:08:24 Channel No. 90 10 0 BER Rx Level -10 -85.0 dBm -20 Phase Error d B -30 Timeslot 4 -40 -50 Summary -60 BTS Power MAX -70 0 20 40 60 80 100 120 140 Bits Modulation Spectrum Measured BTS Power T.A. : GPIB : 20 July 2004 6113 Customer.ppt Current 2.50 dBM RXLEV: Std:10 MHz Minimum 2.29 dBm Maximum 3.53 dBm More... RXQUAL: Results: Off Commercial in Confidence Offsets : On Abort 6113 Base Station Test Multimode Modulation Spectrum Test Information MultiMode : Modulation Spectrum 10 0 BER 6 DEC 1995 12:24:59 Channel No. 90 512 10 Rx Level -104.0 dBm -10 -20 Phase Error Timeslot d -30 B 4 -40 Power Profile BTS Power -50 MAX -60 -70 Summary -500 -400 -300 T.A. : GPIB : 20 July 2004 6113 Customer.ppt -200 -100 RXLEV: Std: 10 MHz 0 kHz 100 200 300 400 500 More... RXQUAL: Results: Off Commercial in Confidence Offsets : On Abort 6113 Base Station Test 6113 CITA What is CiTA? • Cell Integrity Test • Tests the whole cell – antennas as well as BTS RF performance • Used to assess the quality of the radio channel between a BTS and a mobile anywhere in the cell July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Benefits of CiTA • Checks Uplink & Downlink quality • Checks the citing & orientation of all antennas • Checks the performance of masthead LNAs • Checks UL/DL antenna balance of site • Checks voice quality& BER • Checks cell coverage • Identifies interference • Identifies potential site location • Optimises network performance July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test CiTA Process • • • • • Racal 6113 provides a one cell network Make calls using mobile/test sim Loopback in 6113 for voice quality assessment Loopback in 6113 for BER test measurements Monitors RxLevel/RxQuality Reports July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test How Does CiTA Work? TxBTS BTS Tx Level = 6 BTS 6113 RXLEVD RXQUALD RXLEVU RXQUALU sent to BSC DL_Attn = BTS Tx power (dB) - MS RxLev (dB) = 40 – (2 * 6) - (-57) = 85dB July 2004 6113 Customer.ppt Commercial in Confidence downlink RXLEVD RXQUALD sent to BTS Test SIM UL Att.(dB) DL Att.(dB) Min Max Av. Min Max Av. 81 95* 90 77 111* 87 83 89 87 76 86 82 80 99 92 81 97 90 84 95 89 82 92 87 81 91 86 77 91 82 89 99 95 81 94 85 79 88 82 75 85 77 6113 Base Station Test Call Info BSC BTS Test SIM 6113 July 2004 6113 Customer.ppt Logs following information: ARFCN Timeslot BTS power Mobile power Uplink RXLEV Uplink RXQUAL Downlink RXLEV Downlink RXQUAL Commercial in Confidence 6113 Base Station Test CiTA Results 5.01P - 24 Jan 00 CiTA PASS ARFCN 518 TRX ID 1 IMSI TS 1 2 3 4 5 6 7 Min 0.00 0.00 0.00 0.00 0.00 0.00 0.00 July 2004 6113 Customer.ppt Timeslot Format All TCH/F 001010123456789 BER Max 0.03 0.00 0.00 2.08 0.00 0.00 2.09 Av. 0.00 0.00 0.00 0.42 0.00 0.00 0.43 UL Att.(dB) Min Max Av. 81 95* 90 83 89 87 80 99 92 84 95 89 81 91 86 89 99 95 79 88 82 MS Tx Level BTS Tx Level UL Pwr Ctrl Call Set-up DL Att.(dB) UL QUAL Min Max Av. Mn Mx Av 77 111* 87 0 0 0 76 86 82 0 0 0 81 97 90 0 0 0 82 92 87 0 0 0 77 91 82 0 0 0 81 94 85 0 0 0 75 85 77 0 0 0 Commercial in Confidence 10 6 OFF MT DL QUAL Mn Mx Av 0 2 0 X 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6113 Base Station Test CiTA-GPS • CiTA with GPS • RF parametric measurements • • • • • • July 2004 6113 Customer.ppt UL/DL Level, Quality Loss BER, FER, Class 1b, Class 2 Timing Advance, Time Slot, DTMF Timestamped results stored on memory card Timestamped GPS location Time-matched using PC application to show location vs Cell performance (CiTA Data) Commercial in Confidence 6113 Base Station Test CiTA-GPS Screenshot July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Live Testing Main Menu Parameters Main Menu 14 DEC 2003 14:12:44 Information 6113 Offsets Results Live Tests Special Functions A-bis File Controlled Manager PCS 1900 Self Tests / Tests Test Sequences System T.A. : GPIB : 20 July 2004 6113 Customer.ppt BTS RXQUAL: RXLEV: Std: 10 MHz Results: Off Commercial in Confidence Offsets : On 6113 Base Station Test Live Testing Benefits • BTS in Real Traffic on real network conditions. • Don’t Need take site off air and so can perform routine maintenance. • Scan Mode to find Network BCCH(s) • Transmitter Tests (freq error, Phase Error, Mod Spectrum, BER) • Call Set-up for Receiver Sensitivity and Rx BER Tests July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Live Tests Process BSC BTS 6113 Connect to BTS Rx monitor port(s) Connect to ‘tee’ in up-link A-bis (high impedance) Perform Call Set-up with Live SIM Receiver Bit Error Ratio via A-bis Note: limited control with Call Setup July 2004 6113 Customer.ppt Commercial in Confidence SIM Reader Live SIM 6113 Base Station Test Live Testing Menu Live Tests 31 MAY 1997 12:42:48 CURRENT SETTINGS Radio System Type : BTS Manufacturer : BTS Model : Interface : RF Configuration : Unit Software Version : T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXLEV: Std: 10 MHz BTS Information RF Tests (B.O.S.S.) PCS 1900 A-bis Protocol Analysis XXXXXXXXX XXX A-bis, Unbalanced Simplex 5.01p RXQUAL: Results: Off Commercial in Confidence Offsets : On EXIT 6113 Base Station Test RF Testing - Channel Scan Channel Table Type Display CCH + TCH Scan Range Channel Level (dBm) MCC MNC LAC 1442 438 CCH TCH TCH TCH 23 12 13 14 -41.4 234 Banjo CCH 64 -73.6 234 1ABC TCH TCH TCH TCH CCH 65 69 73 77 121 -98.4 001 Test Progress T.A.: GPIB: July 2004 6113 Customer.ppt 1 JAN 1997 12:00:00 Channel 123 RXLEV: CI BSIC 7,4 427 923 1,0 0 0 0,5 Scan Range : 1 to 124 RXQUAL: Std: 10 MHz Results: Off Commercial in Confidence Offsets : Off Stop 6113 Base Station Test RF Testing Summary Screen BER RF Tests - Summary 1 JAN 1997 12:00:00 BER Test Status Phase Error Power Profile No call present BTS Tx Power -16 10 4.80 Deg Peak Phase Error 0 40 12.60 Deg Power Profile Signal CI T.A.: Parameters July 2004 6113 Customer.ppt 2.50 dBm 0 MCC Print 16 RMS Phase Error Frequency Error -100 Modulation Spectrum GPIB: 100 Modulation Spectrum Pass Control Channel 234 18325 Register Call Status MNC Test Network LAC RXLEV: 43210 -96.70 Hz Off NCC 1 BCC Scan/ Scan/ Channel Channel Table Table Lock to CCH Not Registered CCH Channel Place Call 90 90 4 More... RXQUAL: Std: 10 MHz Results: Off Commercial in Confidence Offsets : Off EXIT 6113 Base Station Test Call Set-up Screen 19 JUN 1998 12:00:00 Call Setup Edit Parameter Place Call Cancel All Value Parameter Number to Dial Reset All Default 01628123456 6 6 Test Pattern Allowed list : N/A T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXQUAL: RXLEV: 10 MHz Rslts : OFF Commercial in Confidence S D Offsets : 0.00 dB F R EXIT 6113 Base Station Test Call Present RF Tests - Summary BER Rx Class II RBER Phase Error Power Profile 19 JUN 1998 12:00:00 0 BTS Tx Power -16 4 0.00 % 16 2.50 dBm RMS Phase Error 0 10 4.80 Deg Peak Phase Error 0 40 12.60 Deg Frequency Error -100 Modulation Spectrum Power Profile Signal MCC Configure Printer CI T.A. : Parameters July 2004 6113 Customer.ppt GPIB : 20 100 Modulation Spectrum Pass Traffic Channel Call Status MNC Test Network 234 18325 LAC 43210 1 Off Call Ch 62, TS 4 BCC RXQUAL: RXLEV: 10 MHz Rslts : OFF Measure BTS Rx Sensitivity 90 More... 4 S D Offsets : 0.00 dB Commercial in Confidence Re-Scan A-bis -96.70 Hz CCH Channel NCC Clear Call F R EXIT 6113 Base Station Test BTS Rx Sensitivity Screen Edit Parameter Test : Sensitivity 19 JUN 1998 12:00:00 Value Parameter Initial Level Final Step Size Pass/Fail Threshold Test Pattern Sample Time FER Limit Class Ib Limit Class II Limit Cancel All Reset All -80.0 0.5 -104.0 6 10 0.200 0.400 2.000 Run Test Default -80.0 0.5 -104.0 6 10 0.200 0.400 2.000 dBm dB dBm s % % % Allowed list : -120.0 to -40.0 dBm T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXQUAL: RXLEV: 10 MHz Rslts : OFF Commercial in Confidence S D Offsets : 0.00 dB F R EXIT 6113 Base Station Test Special Functions Power Meter Signal Generator Special Functions Menu Special Functions 14 JUN 1997 14:12:44 Signal Generator Power Meter T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXLEV: Std: 10 MHz RXQUAL: Results: Off Commercial in Confidence Offsets : On EXIT 6113 Base Station Test Special Functions - Power Meter Scan Type MAX POWER Power Meter 14 JUN 1997 BTS Tx Power 0 Signal Nearest ARFCN 50 -7.42 14:12:44 ARFCN 90 dBm FOUND 90 Re-Scan T.A. : GPIB : 20 July 2004 6113 Customer.ppt RXLEV: Std: 10 MHz RXQUAL: Results: Off Commercial in Confidence Offsets : On EXIT 6113 Base Station Test Special Function - Signal Generator Edit Parameter Test : Signal Generator 31 OCT 1996 Value Parameter Channel Number Frequency Offset Output Level Cancel All Signal Format Pulsing Training Sequence Reset All Run Test Default 90 0 90 0 -20.0 Off Off 0 -20.0 Off Off 0 Hz dBm Range : 0 to 124, 975 to 1023 T.A. : GPIB : 20 July 2004 6113 Customer.ppt 12:42:48 RXLEV: Std: 10 MHz RXQUAL: Results: Off Commercial in Confidence Offsets : On EXIT 6113 Base Station Test Other Features • Synchronisation port for Spectrum Analyser • Full control of Global GSM Parameters • Full remote control via GPIB • Self test • Software upgrade program July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test EDGE features, applications and tests EDGE Features, Applications and Tests • 6113 EDGE option for testing EDGE capable base stations • Similar functionality to existing 6113 • A-bis interface for full BTS control and BLER measurements • Support for all major manufacturers July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test (E)GPRS channels supported • In addition to the current GSM channel types, the following (E)GPRS channels are also supported: • CS-1 to CS-4 • MCS-1 to MCS-4 • MCS-5-9 * GMSK GMSK 8-PSK MCS-6 to MCS-9 will be added as part of the ongoing enhancements and software support July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test A-bis Measurement Mode July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test EDGE Mapping Table • Define EDGE Abis Timeslot usage by Allocating EDGE Traffic slots to TRXs July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test EDGE Transmitter Tests • • • • • Signal power level Modulation spectrum Frequency Burst profile Phase error (GMSK) or EVM (8-PSK) July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Transmitter Test July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test TxTest - Modulation Spectrum July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test TxTest - Power Profile July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test TxTest - EVM July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test TxTest - IQ Vector Plot July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Transmitter BLER July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test EDGE Receiver Tests • • • • Receiver BLER test Absolute sensitivity test RX Level test RX Quality test July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Receiver BLER July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Manufacturers supported • • • • • • Alcatel Ericsson Motorola Nokia Nortel Siemens July 2004 6113 Customer.ppt • Support for other BTS manufacturers will be considered on a case by case basis Commercial in Confidence 6113 Base Station Test 6113 EDGE • Available now • • • • Ericsson Nortel Nokia Siemens July 2004 6113 Customer.ppt • Available Q2/FY05 • Alcatel • Motorola Commercial in Confidence 6113 Base Station Test Upgrades and new test sets Upgrading an existing test set • Order options 440R and S440 • Hardware upgrades: • Units manufactured before Dec 03 need to be returned to local RIWS service centre for hardware upgrade • Units manufactured from Jan 04 will be shipped with EDGE capable hardware to allow softwareonly upgrade to be carried out at the customer’s site July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test Ordering a new test set • Order manufacturer options plus EDGE options 440 and S440 July 2004 6113 Customer.ppt • Manufacturer support: • • • • • • Commercial in Confidence Alcatel Ericsson Motorola Nokia Nortel Siemens option 275 option 220 option 255 option 270 option 250 option 235 6113 Base Station Test Software Support • Software support contracts ensure that the 6113 EDGE remains up to date with the latest base station software and functionality. • As part of the ongoing software support additional EDGE functionality will be added to the test set: • • • • • Tx/Rx BLER MCS-6 to MCS-9 Tx Downlink Power Control Rx Absolute Sensitivity MCS-6 to MCS-9 Rx Quality and Rx Level Multimode • Valid software support contract needs to be in place for new units and units that are to be upgraded July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test I and C Testing Our strengths • • • • • • • Transmitter and receiver testing Manufacturer specific software One box dedicated solution Accuracy of measurement Single button testing Racal experience and reputation Industry standard with 2000 units in use by virtually every GSM operator in the world July 2004 6113 Customer.ppt Commercial in Confidence 6113 Base Station Test
© Copyright 2024 Paperzz