Objectives • Compare calculated Q with experimental Q for PMMA coated toroidal devices. In these experiments, I varied the: • Wavelength (850nm, 980nm) • Film thickness (0-100nm) • I kept the input power very low, toroid geometry consistent H-S. Choi, 10/2009 Objective 1: 850nm measurements Increasing film thickness 0 nm 20nm 50nm Decreasing Q factor H-S. Choi, 10/2009 Objective 2: 980nm measurements Increasing film thickness 0 nm 20nm 50nm 100nm Decreasing Q factor H-S. Choi, 10/2009 Objective 3: Comparison of theory and experiment Q theory The experimental Q always seems to be nearly same amount below the theory Q – maybe surface roughness? Q theory H-S. Choi, 10/2009 Next Month • • • Finish testing PMMA (100nm at 850nm) Maybe try retesting to reach theory Q? Look at PS as well, using same experimental parameters (film thickness, wavelength, toroid size, input power) H-S. Choi, 10/2009