PRODUCT SPECIFICATION SHEET PE-BC SERIES Exit Sign with Emergency Light Function MODEL NO: TYPE: PROJECT: COMMENTS: Lightweight, injection-molded thermoplastic ABS housing Red or Green Legend Adjustable Dual LED Lamps White thermoplastic ABS design Single or Double-Sided Optional Self-Diagnostic Capability DESCRIPTION IOTA’s PE-BC Series injection-molded thermoplastic exit signs combine lightweight, durable design with emergency lighting capability for either wall or ceiling installations. IOTA PE-BC Series exit signs offer designs with either red or green illumination with dual adjustable 3.5W LED lamp heads for bi-directional illumination in the event of a loss of normal AC power. The PE-BC Series is suitable for both single-sided and double-sided applications. The PE-BC Series is UL Listed for use in damp locations. Self-Diagnostic option available. Refer to reverse side for Product Ordering Guide. FEATURES Lightweight, impact-resistant, injection-molded thermoplastic ABS construction. Bright, efficient, and long-lasting red or green LED illumination with 10-year design life. Dual LED lamp heads with directional adjustment for optimal emergency lighting. Designed for either single or double-sided installation with wall, side, or ceiling mounting. Removable directional indicators (chevrons). SPECIFICATIONS Input Voltage ................................................................................... (Dual) 120/277V, 60Hz Input Power......................................................... Refer to chart on reverse side for input rating details Light Source (exit compartment)........................................................... Long-life LED array Light Source (emergency fixture).................................................................... (2) 3.5W LED Lettering....................................................................................... 6″ height with .75″ stroke Operating Temp................................................................................................ 10° to 40° C Battery Type .......................................... Long-life self-contained maintenance-free Ni-Cad Operation........................................................................................................... 90 minutes Recharge Time ......................................................................................................... 24 Hrs Approval......................................................................................................... UL 924 Listed California Energy Commission Meets or exceeds NFPA 101, NFPA 70, and IBC requirements Additional battery option for remote light capability. Optional self-diagnostic function. Canopy and mounting hardware included. Includes test switch and charge indicator accessories. Low-voltage disconnect, AC lockout, and brownout protection. UL Listed for damp locations in temperatures ranging from 10° to 40° C. Meets or exceeds all NEC, IBC, and Life Safety Code emergency lighting requirements. DIMENSIONS 11 13/16" 5-Year Warranty. See Warranty Page for details. 1 13/16" RoHS Compliant MOUNTING CANOPY 4 5/8" 7 1/4" 9 1/2" 5 7/8" 1" IOTA REV 071015 IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 Product specifications are subject to change without notice TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com EXIT & EM FIXTURES UL Damp Location Listed Internal diffuser eliminates striations and hot spots, providing even illumination during all operating modes. PE-BC SERIES Exit Sign with Emergency Light Function ORDERING GUIDE Use the Ordering Guide below to determine the Catalog # of the model required for your application. Please note that some options may not be available on all products. PE BC R Red EXIT lettering G Green EXIT lettering (blank) R INPUT RATING REFERENCE 120VAC 277VAC PEBC - Red 2.9W 3.0W PEBC - Green 2.9W 2.8W PEBC - Red, w/ Battery (x2) 2.9W 3.0W PEBC - Green, w/ Battery (x2) 2.9W 2.9W PEBC - Red, Self-Diagnostics 2.9W 2.9W PEBC - Green, Self-Diagnostics 3.0W 2.9W PEBC - Red, Self-Diagnostics, w/ Battery (x2) 2.9W 2.9W PEBC - Green, Self-Diagnostics, w/ Battery (x2) 3.0W 3.0W MODEL TYPE Single Battery SD Self-Diagnostics Option Conducts automatic monthly and annual testing. Double Battery for optional remote light capacity SELF-DIAGNOSTIC FEATURE (OPTIONAL) When AC power is supplied to the fixture, the self-testing feature is automatically initiated as follows: Tests the status of the battery, charger board, lamps, and transformer every five seconds. Conducts a full 1-minute test once every month. Conducts a 30-minute test every six months. Conducts a 90-minute test every twelve months. The status of the unit is communicated via a dual-color LED indicator. If during the self-testing procedure, the unit encounters a fault, the dual-color LED indicator will flash Red, using the following diagnostic codes: One Flash Battery is not connected Two Flashes Battery is shorted or battery voltage drops below acceptable levels Three Flashes Charger Board failure Four Flashes Transformer failure Five Flashes Lamp failure Six Flashes Remote Lamp failure (if present) Seven Flashes Exit LED strip failure (for Exit Signs only) A four-second interval will occur between codes IOTA REV 071015 IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com
© Copyright 2026 Paperzz