NEUTRON RESPONSE FUNCTION FOR A DETECTOR WITH 3He COUNTERS FOR THE 0.39 – 1.54 MeV NEUTRON ENERGY RANGE J. Černý1, Z. Dlouhý2, Z. Doležal1, M.P. Ivanov, P. Kubik1, E.A. Kuznetsova,Yu.E. Penionzkevich, E.A. Sokol, J. Švejda1 and I. Wilhelm1 1 -Institute of Particle and Nuclear Physics, Faculty of Mathematics and Physics, Charles University, 2180 00 Prague 8, Czech Republic; 2 -Nuclear Physics Institute, Academy of Sciences of the Czech Republic, 250 68 Rež near Prague, Czech Republic In the present work1), we have measured the response functions of two neutron detector arrays, with 39 3He proportional counters each, for monoenergetic neutrons within the 0.39 – 1.54 MeV neutron energy range. The main goals of the measurements were to obtain experimental data on the sensitivity of neutron counting to varying neutron energies and the influence of the thickness of the polyethylene moderator. The experimental data will be used for constructing optimal neutron detector arrays with modules for studies of the properties of the delayed neutrons from fission fragments within the framework of the Dubna Radioactive Ion Beams (DRIBs) and Accélérateur Linéaire auprés du Tandem d’Orsay (ALTO) projects. Each neutron detector array consisted of 39 modules arranged in six layers. In the first assembly, all the modules were identical and each of them consisted of a hexagonal polyethylene unit (distance between parallel planes – 50 mm) with a cylindrical cavity (diameter 32 mm) for a neutron counter. The length of the counter and the polyethylene moderator was 50 cm. The counters were filled with 3He up to a pressure of 7 atm. Every neutron counter was supplied with a pre-amplifier, which was mounted rigidly to the counter and had a cylindrical case; the cases of the pre-amplifiers were used for fixing the neutron counters in assembling. In the second assembly, the polyethylene moderator was removed from the modules of the 2nd and 4th rows. The detection assemblies were surrounded by a shield of boron loaded polyethylene with a window in the front side; this window was covered with 1 mm cadmium foil. The experiments described here were performed with the Van de Graaf electrostatic accelerator HV2500AN at Charles University, Prague, Czech Republic. Monoenergetic neutrons were produced as secondary particles from a 3 H(p,n)3He reaction on a Ti-T target (0.2 mg/cm2) with a molybdenum backing. The target was mounted at an angle of 45o to the incident proton beam, so the real thickness of the target was about 0.28 mg/cm2. The counting rates of the separate groups of neutron counters arranged in the central part of each layer of the detection assemblies and the monitor detectors were measured at different energies of incident neutrons. The good sensitivity of both arrays to a change in neutron energy is clearly seen, so the valid correlation of the count rate ratios for different rows of neutron counters with neutron energy was obtained. If the detection sensitivity versus neutron energy curve for one row of counters is quite different from that for another row of counters, the ratio of counts for the two rows will be a function of neutron energy. It is seen from a comparison of the two response functions that removing part of the moderator leads to the displacement of the maximum of the rate to the deeper layers of the counter and the total detector sensitivity drops with the decreasing of the volume of the moderator. For the detection assembly with a larger amount of moderator, the registration sensitivity is systematically higher for all neutron energies. As neutron energy increases, the neutron registration sensitivity increases. This can be explained by the fact that at low energies, a considerable fraction of neutrons are reflected by the front layers of the detectors and do not penetrate into the assembly; neutrons of higher energies penetrate deeper into the assembly and their losses due to reflection are smaller. 4detectors will register low-energy neutrons more effectively, because they do not abandon detectors due to reflections in the other internal layers, but high-energy neutrons will leave the assembly. The experimental sensitivity curves were compared with calculated response functions generated using the MCNP code2) version B. During calculations good agreement with experimental information was achieved. Calculations with a larger amount of moderator in detectors were conducted, the distance between the parallel planes of the polyethylene hexahedrons being changed from 5 cm to 6, 7 and 8 cm. The calculations showed that the distance between the parallel planes of the polyethylene hexahedrons about 6.5 cm is optimal. Taking into account that in experiments with 4 detectors, neutrons get into detectors isotropically, the effective thickness of moderator in our modules is near to optimal. It is also necessary to notice that an increase in the thickness of the moderator results in an increase in the neutron life time in the detectors, which, in experiments in studying delayed neutrons in coincidences with β-particles or γ-rays or in multiple neutron measurements, results in an increase in the background from random coincidences. Consequently, since neutron registration sensitivity depends weakly on the energy of incident neutrons up to an energy of 1.5 MeV, a neutron detector must consist of no less than 4-5 layers of modules comprising neutron detectors (7 atm 3Не, 32 mm in diameter) and moderator surrounding the detectors by a layer approximately 1 cm thick. REFERENCES 1) Černý J.et al., Nucl. Instr. & Meth., A540 (2005) 430. 2) Briesmeister J.F. (Ed.), Program MCNP, Version 4A, Los Alamos, Report LA12625-M, 1993.
© Copyright 2026 Paperzz