optivent in-line mdi spacer optimal performance and optimal value

OPTIVENT IN-LINE MDI SPACER
OPTIMAL PERFORMANCE AND
OPTIMAL VALUE
• Designed to optimize drug delivery
• Designed to reduce fluid accumulation
• Designed to optimize value and ease-of-use
8 0 0 . 3 4 5 . 6 4 4 3
R E S P I R O N I C S . C O M
7 2 4 . 3 8 7 . 4 0 0 0
OptiVent In-Line MDI Spacer for use in
Ventilator Circuits
MDI Canister
PRODUCT SPECIFICATIONS
DIMENSIONS
Length
6.0 in
Diameter
1.4 in
Weight
0.8 oz (22 gm)
MATERIALS
OptiVent is made of impact-resistant polypropylene.
QUALITY ASSURANCE
100% of OptiVent units are quality-control tested at the factory before shipment.
HOW SUPPLIED
Each OptiVent unit is individually packaged in a tamper-evident bag along with
instructions for use.
VENTILATOR COMPATIBILITY
OptiVent makes more fine particle dose available to
the patient. In a comparative study, aerosol testing
demonstrated OptiVent consistently provided a greater
fine particle dose of albuterol, beclomethasone, and
cromolyn sodium.1
More fine particle dose output means better patient
outcomes. Clinical research showed a greater improvement
in airway resistance and total work of breathing with
OptiVent, as compared to another in-line spacer.2
Less fluid accumulation with OptiVent means a reduction
(or elimination) in the number of times vent circuits must
be opened for drainage. A study of water accumulation in
three in-line spacers concluded OptiVent accumulated a
clinically insignificant amount of fluid (under simulated
use conditions).2
OptiVent has a 22mm ID connector on the patient end, and a 22mm OD connector on the
ventilator end.
MDI CANISTER COMPATIBILITY
OptiVent can be used with most currently available MDI canisters. OptiVent is designed to
guide the canister stem into the delivery port and to structurally support it during
actuation.
ORDERING INFORMATION
PRODUCT DESCRIPTION
REORDER NUMBER
UNITS/CASE
OptiVent
HS762-010
10
OptiVent with 15mm Adaptors
HS763-020
20
OptiVent
(CE marked with multilingual packaging)
HS762EU-001
1
OptiVent offers convenience to healthcare professionals.
OptiVent does not need to be manipulated or expanded to
be used in a ventilator circuit. It has the dual benefit of
minimal water collection and ease of use as compared to
other competitive products.3
References: 1. Dalby RN, et al. Evaluation of Aerosol Drug Output
From Ventilator Circuits Fitted with the OptiVent® and AeroVent®
In-Line Spacers. Respiratory Drug Delivery VI: Proceedings of an
International Symposia Organized by the School of Pharmacy of
Virginia Commonwealth University. May 1998. ISBN: 1-57491-076-0.
2. Waugh JB, et al. Bronchodilator response with use of OptiVent
versus Aerosol Cloud Enhancer metered-dose inhaler spacers in
patients receiving ventilatory assistance. Heart & Lung 1998;27:41823. 3. Waugh JB, Waugh JB, Rau JL. Evaluation of water
accumulation in the HealthScan OptiVent®, DHD ACE®, and
Monaghan AeroVent® MDI spacers under normal mechanical
ventilation conditions. Am J Respir Crit Care Med 1997;155(4):A671.
Rx Only
Envisioning tomorrow. Improving today.
SM
Customer Service: 800-345-6443 or 724-387-4000
Respironics Europe, Africa, Middle East: +33-1-47-52-30-00
Respironics Asia Pacific: +852-3194-2280
www.respironics.com
Respironics and OptiVent are registered trademarks of Respironics New Jersey, Inc. and
Envisioning tomorrow. Improving today. is a service mark of Respironics, Inc. and its affiliates.
© 2008 Respironics, Inc. and its affiliates. All rights reserved.
DD
MCI 4101778
PN 1054634