ARCAT spec 07460may 07460may 2013-11-25

SECTION 07460
ALUMINUM SIDING AND SOFFITS
Display hidden notes to specifier. (Don't know how? Click Here)
Copyright 2016 Mayne Coatings Corp. - All rights reserved
PART 1 GENERAL
1.1
1.2
1.3
SECTION INCLUDES
A.
Aluminum Siding.
B.
Aluminum Soffits.
C.
Aluminum Thermally Broken Back framing System.
D.
Aluminum trim and accessories.
E.
Aluminum privacy screen system
RELATED SECTIONS
A.
Section 05400 - Cold-Formed Metal Framing: Metal framing for support of aluminum
soffits.
B.
Section 06100 - Rough Carpentry: Wood stud framing, furring, and sheathing for support of
aluminum soffits.
C.
Section 07210 - Building Insulation: Rigid thermal insulation installed behind siding.
D.
Section 07600 - Flashing and Sheet Metal: Sheet metal gutters and downspouts.
E.
Section 07900 - Joint Sealers: Sealants used in conjunction with aluminum siding
installation.
REFERENCES
A.
ASTM D 958 - Practice for Determining Temperatures of Standard ASTM Molds for Test
Specimens of Plastics.
B.
AAMA 2605-05 - Voluntary Specification, Performance requirements and Test Procedures
for Superior Performing Organic Coatings on Aluminum Extrusions and Panels.
C.
AAMA 2604 - Voluntary Specification, Performance requirements and Test Procedures for
High Performing Organic Coatings on Aluminum Extrusions and Panels.
07460-1
1.4
1.5
D.
AAMA 2603 - Voluntary Specification, Performance requirements and Test Procedures for
Pigmented Organic Coatings on Aluminum Extrusions and Panels.
E.
ASTM E2768-11 – Standard Test Method for Extended Duration Surface Burning
Characteristics for Building Materials (30 min Tunnel Test). Results: Zero Flame Spread,
Smoke Developed Index of 5. Meets criteria for Class A fire rating.
F.
ASTM E136 - Standard Test Method for Behavior of Materials in a Vertical Tube
Furnace at 750°C
G.
CAN/ULC S114 – Standard method of test for determination of noncombustibility in building materials.
PERFORMANCE REQUIREMENTS
A.
Components: Design and size components to withstand dead and live loads caused by
positive and negative wind pressure acting normal to plane of wall as calculated in
accordance with applicable code.
B.
Movement: Accommodate movement within system without damage to components or
movement within system; movement between system and perimeter components when
subject to seasonal temperature cycling; dynamic loading and release of loads; deflection
of structural support framing.
C.
Drainage: Provide positive drainage to exterior for moisture entering or condensation
occurring within panel system.
SUBMITTALS
A.
Submit under provisions of Section 01300.
B.
Product Data: Manufacturer's data sheets on each product to be used, including:
1.
Preparation instructions and recommendations.
2.
Storage and handling requirements and recommendations.
3.
Installation methods.
C.
Shop Drawings: Indicate dimensions, layout, joints, expansion joints, construction details,
methods of anchorage, and interface with adjacent materials.
D.
LEED Submittals: Provide documentation of how the requirements of Credit will be met:
1.
EAc1 Energy & Atmosphere: Provide documentation on how the aluminum siding
back framing system can reduce the design energy consumption and/or cost. (LEED
Form).
2.
MRc2 Construction Waste Management: For products being recycled,
documentation of total weight of project waste diverted from landfill. (LEED Form).
3.
MRc5 Local and Regional Materials: Product Data for Credit MR 5.1 and Credit MR
5.2. Submit data, including location and distance from project of material
manufacturer and point of extraction, harvest or recovery for main raw material.
(LEED Form).
4.
MRc8 Durable Building: Provide documentation on how the use of aluminum
siding/soffit will help increase the building's service life. (LEED Form).
5.
EQc4.2 Low Emitting Materials - Provide documentation on how the powder
coating on the aluminum siding/soffit indoors has no VOC's and will not contribute
to air pollution/ozone depletion. (VOC Certification Letter).
07460-2
6.
7.
1.6
1.7
1.8
E.
Selection Samples: For each finish product specified, two complete sets of color chips
representing manufacturer's full range of available colors and patterns.
F.
Verification Samples: For each finish product specified, two samples, minimum size 2
inches (51 mm) by 3-1/2 inches (89 mm), representing actual product, color, and gloss.
G.
Manufacturer's Certificates: Certify products meet or exceed specified requirements.
H.
Closeout Submittals: Provide manufacturer's maintenance instructions that include
recommendations for periodic cleaning and maintenance of components.
QUALITY ASSURANCE
A.
Manufacturer Qualifications: Minimum five years experience producing aluminum finishes
of the types specified and AkzoNobel, AAMA 2605 and 2605 Certified.
B.
Installer: Company specializing in performing Work of this section with minimum three
years documented experience.
C.
Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and
application workmanship.
1.
Finish areas designated by Architect.
2.
Do not proceed with remaining work until workmanship, color, and gloss are
approved by Architect.
3.
Refinish mock-up area as required to produce acceptable work.
DELIVERY, STORAGE, AND HANDLING
A.
Package and store products under cover in manufacturer's unopened packaging until ready
for transport and installation.
B.
Protect panels from accelerated weathering by removing or venting sheet plastic shipping
wrap.
C.
Store prefinished material off ground protected from weather, to prevent twisting,
bending, or abrasion, and to provide ventilation. Slope metal sheets to ensure drainage.
D.
Prevent contact with materials capable of causing discoloration or staining.
PROJECT CONDITIONS
A.
1.9
EQc7.1 Thermal Comfort: Provide documentation on how the aluminum siding
backframing system, which allows for external insulation, helps the building to
maintain an indoor level of comfort at greater energy efficiency. (LEED Form).
IDc1.1 Innovation in Design: Provide documentation on how the use of aluminum
siding/soffit with a powder coated finish supports innovation in design. (LEED
Form).
Maintain environmental conditions (temperature, humidity, and ventilation) within limits
recommended by manufacturer for optimum results. Do not fabricate products under
environmental conditions outside manufacturer's absolute limits.
COORDINATION
A.
Coordinate Work with installation of windows, louvers, and adjacent components or
materials.
07460-3
1.10
WARRANTY
A.
Mayne Coatings Corp. limited warranty against cracking, peeling and gloss/color retention
within the guidelines stated by the American Aluminum Manufactures Association
(AAMA).
1.
Standard Colors:
a.
D2000 - AAMA 2604 (5 Year Florida) 15 Year manufacturer's Warranty
b.
D3000 - AAMA 2605 (10 Year Florida) 20 Year manufacturer's Warranty
2.
Woodgrains
a.
AAMA 2604 (5 Year Florida) 15 Year manufacture's Warranty
PART 2 PRODUCTS
2.1
MATERIAL MANUFACTURERS
A. ACCEPTABLE MANUFACTURE: Mayne Coatings Corp., which is located at: 27575-50th Ave. ;
Langley, BC; Canada V4W 0A2; Tel: 604-607-6630; Fax: 604-607-6680; Email: request
info ([email protected]); Web: www.longboardproducts.com
2.2
B.
Substitutions: Not permitted.
C.
Requests for substitutions will be considered in accordance with provisions of Section
01600.
MATERIALS
A. Extruded Aluminum Siding and Soffits: Longboard Wood Grain Aluminum Siding and Soffits
with Alluminate bonded film finish is extruded aluminum with integrated venting system.
1.
Size:
101802
4” V Groove Siding & Soffit -12 pieces per box
101973
6” Channel Siding & Soffit - 8 pieces per box
102311
6” V Groove Siding & Soffit - 8 pieces per box
B. Accessories: Prefinished aluminum: Provide with matching accessories and starter strips as
required.
101957
102304
102000
102044
102324
102305
102611
102612
102613
102044
102355
2.5 inch perforated vent strip 12 ft length
2.5 inch V groove siding and soffit 12 ft length
J track 12 ft length
Wide Starter Strip 12 ft length
Inside Corner
Outside Corner
Finish Base & Cap (2pc set)
Base & U Cap (2pc set)
Base & Flat Cap (2pc set)
Powder Coated Wide Starter Strip
Quick Screen Clip
07460-4
C. Aluminum Privacy Screen System: Aluminum Tubes and Accessories
102549
Single Post 12 ft Lengths
102542
1” X 3” Tube 24 ft Lengths
102548
1” X 5” Tube 24 ft Lengths
102565
Single Post Base Plate
102566
Double Post Base Plate
102567
Corner Base Plate
102552-3
3” Tube End Caps
102552-5
5” Tube End Caps
102543-S
Single Post End Caps
102543-D
Double Post End Caps
102554
Flat Bar 12 ft lengths
102547
Mounting Brackets
102554-3
Flat Bar Spacers – 1” X3” Tube 1” Space
102598
#10 Black Screws (fasteners for post caps)
102554-5
Flat Bar Spacers 0 1” X 5” Tube 1” Space
102551
Block Spacers
D. Thermally Broken Back framing system: Provide clip sizes and girt lengths required.
102589
2" T-Clip
102510
3" T-Clip
102323
4" T-Clip
102511
5" T-Clip
102512
6" T-Clip
102509
Aluminum Girt 10'
102322
Aluminum Girt 12'
07460-5
2.3
FlNlSHES; Lead time varies based on colour and supply. Please check with manufacture for
anticipated lead time for solid and metallic colours.
A.
Pretreatment: E-CLPS Chrome Free five stage aluminum pretreatment system. Complies
with AAMA 2603 AAMA 2604 and AAMA 2605 Superior Performance Standard and meets
EPA, OSHA, State and Local environmental requirements and contains no chromates,
cyanides or other heavy metals. Waste treatment is usually a simple pH neutralization and
disposal to the sanitary sewer.
B.
Akzo Nobel Interpon D2000 Series electrostatically applied Architectural Powder Coatings
are approved to AAMA 2604 Performance Standard.
1.
Gloss Level: Standard Gloss is 30 percent, plus or minus 5 percent.
2.
Solid Colors:
a. Bone White YA200U
b. Common White YA0157
c. Milk White YA201U
d. Sandstone YD2797
e. Ivory YD200U
f. Linen YD2897
g. Cashmere YU2987
h. Almond YU2387
i. Coffee YU2377
j. C. Beige YD2917
k. PG Sandstone YU2367
l. Beige YU2697
m. Cream YD2907
n. Wicker Café YU20A7
o. Canyon Clay YT2847
p. Clay YU2397
q. Seawolf YD204U
r. Storm YU2357
s. Sandstone YD201U
t. Antique Bronze YD203U
u. Medium Bronze YM202U
v. Bronze YT2387
w. Night Hawk Gray YL202U
x. Dark Brown YT2687
y. Classic Bronze YM201U
z. Light Grey YL206U
07460-6
aa. Dove Grey YL201U
bb. Smoke Gray YL204U
cc. Slate Grey YL2407
dd. C. Charcoal YL2437
ee. Charcoal YL200U
ff. Atlantic Gray YL207U
gg. Black YN200U
hh. Military Blue YJ201U
ii. Medium Blue YJ202U
jj. Deep Blue YJ203U
kk. Midnight Blue YJ200U
ll. Summer Yellow YE200U
mm. Light Green YK201U
nn. Dark Ivy YK204U
oo. Interstate Green YK202U
pp. Hartford Green YK200U
qq. Forest Green YK1077
rr. Dark Green YK203U
ss. Sepia Brown YM204U
tt. Chocolate Brown YM2947
uu. Java Brown YM203U
vv. Redwood YG202U
ww. Brick Red YG201U
xx. Claret Red YG203U
yy. Boysenberry YG204U
Architectural Metallics:
a. Venus YW213Q
b. Saturn YW203Q
c. Moon Stone YW204Q
d. Platinum Ice YW202Q
e. Anodic Ice YW212Q
f. Seafoam Mist YW206Q
g. Patina YW207Q
h. Hartford Mist YW208Q
i. Azurite Copper YW210Q
j. Bronze YW209Q
k. Sapphire Ice YW205Q
l. Burgundy Mist YW211Q
C.
Akzo Nobel Interpon D3000 Series electrostatically applied Fluromax Architectural Powder
Coatings are approved to AAMA 2605 Superior Performance Standard.
1.
Gloss Level: Standard Gloss is 30 percent, plus or minus 5 percent.
2.
Solid Colors:
07460-7
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
k.
l.
m.
n.
o.
p.
q.
r.
s.
t.
u.
v.
w.
x.
y.
z.
aa.
bb.
cc.
Milk White 8A200Q
Bone White 8A201Q
Ivory 8D200Q
Light Gray 8L200Q
Sandstone 8D201Q
Seawolf 8D202Q
Antique Bronze 8D203Q
Dove Gray 8L201Q
Medium Bronze 8M202Q
Smoke Gray 8L204Q
Charcoal 8L203Q
Atlantic Gray 8L205Q
Night Hawk Gray 8L202Q
Black 8N200Q
Classic Bronze 8M203Q
Military Blue 8J200Q
Medium Blue 8J201Q
Deep Blue 8J202Q
Midnight Blue 8J203Q
Light Green 8K204Q
Dark Ivy 8K203Q
Interstate Green 8K202Q
Hartford Green 8K200Q
Dark Green 8K201Q
Java Brown 8M200Q
Redwood 8G200Q
Sepia Brown 8M201Q
Brick Red 8G202Q
Claret Red 8G201Q
dd. Boysenberry 8G203Q
Architectural Metallics:
a.
Fluoromax Silver 8W210Q
b.
Fluoromax Aluminum 8W211Q
c.
Fluoromax Slate 8W213Q
d.
Fluoromax Surf 8W207Q
e.
Fluoromax Steel 8W212Q
f.
Fluoromax Quartz 8W209Q
g.
Fluoromax Vega 8W203Q
h.
Fluoromax Azure 8W204Q
i.
Fluoromax Panther 8W205Q
j.
Fluoromax Carbon 8W214Q
k.
Fluoromax Moss 8W206Q
l.
Fluoromax Patina 8W208Q
m.
Fluoromax Burgundy Mist 8W200Q
n.
Fluoromax Bronze 8W202Q
o.
Fluoromax Copper 8W201Q
D.
Super Durable Powder Coatings: Alluminate Premium Wood Finishes use a polyurethane
powder coat with ink based wood grain patterns sublimated into the base powder
effectively tattooing the powder. The combined effect creates all the aesthetic aspects of
real wood while offering the same environmental advantages of powder coated finishes.
1.
Wood Grained
07460-8
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
k.
l.
m.
n.
o.
p.
q.
r.
s.
t.
u.
v.
2.4
Light Ash 1402/02-716
Dark Ash 1402/02-733
Light Cherry 1406/01-716
Dark Cherry 1406/01-733
Light Fir 1501/02-716
Dark Fir 1501/02-733
National Mahogany 1806/02-706
Light National Walnut 1806/02-716
Dark National Walnut 1806/02-733
Dark Knotty Pine 2101/01-716
Mahogany 1802/02-706
Dark Walnut 1802/02-733
Light Oak 2501/05-716
Dark Oak 2501/01-733
Dark Bamboo 2902/03-733
Light Bamboo 2902/03-716
Light Antique Oak 2504/01-716
Dark Antique Oak 2504/01-733
Cordoba Cherry 1404/02-716
Table Walnut 1804/05-733
Light Knotty Pine 2103/01-716
Italian Rosewood 1815/09L-775
FABRICATION
A.
Prepare surfaces, pre-treat and coat components in accordance with AAMA 2604 and 2605
Quality Standards and applicable European standards for the coating material specified.
B.
Wrap and package coated components using methods suitable for transit and covered site
storage without damage.
PART 3 EXECUTION
3.1
3.2
3.3
EXAMINATION
A.
Do not begin installation until colors have been verified.
B.
Verify framing members are ready to receive panel system.
C.
If preparation is the responsibility of another installer, notify Architect of unsatisfactory
preparation before proceeding.
PREPARATION
A.
Clean surfaces thoroughly prior to installation.
B.
Prepare surfaces using the methods recommended by the manufacturer for achieving the
best result for the material under the project conditions.
INSTALLATION
A.
Install in accordance with manufacturer's installation instructions.
B.
Barrier Protection: Do not install over cementitious materials, dissimilar metals or pressure
07460-9
treated material without adequate barrier protection.
1.
Install building paper horizontally on walls to receive metal siding.
2.
Weather lap edges 6 inches (150 mm) and ends minimum 6 inches (150 mm).
3.
Stagger vertical joints of each layer.
4.
Securely staple, nail in place.
3.4
3.5
3.6
3.7
C.
Fasten siding to structural supports; aligned, level, and plumb.
D.
Locate joints over supports.
E.
Install expansion control joints where indicated.
F.
Use concealed fasteners unless otherwise approved by Architect.
G.
Install soffits, and accessories in accordance with best practice, with all joint members
plumb and true.
FIELD QUALITY CONTROL
A.
After installation of soffits, check entire surface for obvious flaws or defects.
B.
Replace and repair any problem areas, paying close attention to the substrate for causes of
the problem.
CLEANING
A.
After application of soffits, clean as necessary to remove all fingerprints and soiled areas.
B.
Upon completion of soffit application, clean entire area, removing all scrap, packaging, and
unused materials related to this work.
PROTECTION
A.
Protect installed products until completion of project.
B.
Touch-up, repair or replace damaged products before Substantial Completion.
SCHEDULES
A.
:
B.
:
END OF SECTION
07460-10