TEENAGE ESCAPE Hip Roof Overview Compact, classic open plan design, the TEENAGE ESCAPE affords you plenty of room with modern convenience. Two bedrooms with free flowing living and kitchen space and your choice of three different roofing styles give this shack a modern charm suitable for backyards or an affordable holiday home. x2 x1 x1 Living Space: 58.68m2 What Back Yard Shacks Supply With Your Shack • Complete building kit to lockup stage using 100% BlueScope materials, including – frame, cladding, roofing, external doors & windows. (Note: internal fixtures, internal doors plasterboard, kitchens, bathrooms, laundry’s etc are not included). • Delivery to your site. • Full engineering plans for frames, roof, sub floor or slab (for Region C2 and N3 wind code areas, this covers from Tasmania to Cairns, to WA excluding Norwest WA). • Full architectural elevations ready for submission to council. • Indicative electrical and plumbing plans for DIY. • Engineering plans for soil classifications A&S, M & MD. Total Area: 58.68m2 BACKYARD 3 Swanston Rd Launceston 1 Bass Hwy Roundhill Burnie 64 Channel Hwy Kingston SHACKS - 6339 4489 - 6432 3668 - 6229 1790 9360 0912 ASW WM BATH 1215 ASW BED 1 1215 ASW S WC SHR REF HP VB 920 CSD KITCHEN 6270 920 2.9 X 3.0 FLOOR PLAN LIVING/DINING 920 1215 ASW AREAS (TEENAGE ESCAPE): TOTAL AREA: 58.68 sqm 1218 ASW TEENAGE ESCAPE 6.0 X 4.2 BED 2 2.9 X 3.0 2124 ASD 1218 ASW Things You’ll Need • Site Plan – A site plan is required for a building application submission to council. • Soil Test – For soil classifications other than above, consult a local engineer to provide RC Slab/Footing engineering to suit your site. • House Energy Rating Report – The BCA (Building Code of Australia) now require a house energy rating report from your respective state. QLD, VIC, TAS, SA, NT & WA all use measures adopted from the BCA regulations, with the exception of NSW. NSW operates its own Building 9960 Sustainability Index or BASIX. ERTAINER • Local Building Certifier or Council Certifier – Home-owners are 215 ASW responsible for appointing 1218 ASW a Licensed Building 1215 ASW Certifier (Building S Surveyor) or council certifier. • A plumbing and Electrical Certifier – to ensure the plumbing drainage • Possible DA (Development Approval) from Local Council – You may need to submit a DA to the Local Planning and Land Authority or Council for approval. and electrical plans comply with prescribed standards. Certifiers must KITCHEN BED 2 be licensed. DINING 3.1 X 3.0 AREAS (ENTERTAINER): LIVING: 63.25 sqm VERANDAH: 9.13 sqm TOTAL AREA: 77.38 sqm FLOOR PLAN 920 920 REF Double Skillion Roof X 6.0 BATH• Mandatory BA3.5(Building Approval) – A BA application must be lodged 920 SHR with the permit authority or local council. LIVING BED 3 3.1 X 3.0 920 WC Skillion Roof BED 1 3.1 X 3.1 920 ROBE 2124 ASD 1215 ASW 1215 ASW VERANDAH BACKYARD 3 Swanston Rd Launceston 1 Bass Hwy Roundhill Burnie 64 Channel Hwy Kingston SHACKS - 6339 4489 - 6432 3668 - 6229 1790
© Copyright 2026 Paperzz