RFC1628MIB表(140801).xls object identifer (1.3.6.1.2.1) 1.1.0 1.2.0 1.3.0 1.4.0 1.5.0 1.6.0 1.7.0 2.1.0 2.2.1.1.1 2.2.1.2.1 2.2.1.3.1 2.2.1.4.1 2.2.1.5.1 2.2.1.6.1 2.2.1.7.2 2.2.1.8.1 2.2.1.9.1 4.20.1.1.1 4.20.1.2.1 4.20.1.3.1 4.20.1.4.1 4.20.1.5.1 (1.3.6.1.2.1.33) 1.1.1.0 1.1.2.0 1.1.3.0 1.1.4.0 1.1.5.0 1.1.6.0 1.2.1.0 オブジェクト名 グループ SYNTAXorOBJECT 2014/8/1 アクセス ステータス 内容 sysDescr sysObjectID sysUpTime sysContact sysName sysLocation sysServices ifNumber ifIndex ifDescr ifType ifMtu ifSpeed ifPhysAddress ifAdminStatus ifOperStatus ifLastChange ipAdEntAddr ipAdEntIfIndex ipAdEntNetMask ipAdEntBcastAddr ipAdEntReasmMaxSize System Group System Group System Group System Group System Group System Group System Group Interfaces Group Interfaces Group Interfaces Group Interfaces Group Interfaces Group Interfaces Group Interfaces Group Interfaces Group Interfaces Group Interfaces Group IP Group IP Group IP Group IP Group IP Group DisplayString (SIZE (0..255)) OBJECT IDENTIFIER TimeTicks DisplayString (SIZE (0..255)) DisplayString (SIZE (0..255)) DisplayString (SIZE (0..255)) INTEGER (0..127) INTEGER INTEGER DisplayString (SIZE (0..255)) INTEGER(1-32) INTEGER Gauge PhysAddress INTEGER(1-3) INTEGER(1-4) TimeTicks IpAddress INTEGER IpAddress INTEGER INTEGER (0..65535) read-only read-only read-only read-write read-write read-write read-only read-only read-only read-only read-only read-only read-only read-only read-only read-only read-only read-only read-only read-only read-only read-only mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory mandatory システム説明 製造元番号 経過時間 管理者 機器名 設置場所 サービス インタフェース数 インデックス 名前 タイプ 最大パケット 転送速度 物理アドレス インターフェース状態 操作状態 時間 IPアドレス インデックス ネットマスク ブロードキャスト The size of the largest IP datagram upsidentManufacturer upsidentModel upsidentUPSSoftwareVersion upsidentAgentSoftwareVersion upsidentName upsidentAttachedDevices upsBatteryStatus upsIdent upsIdent upsIdent upsIdent upsIdent upsIdent upsBattery read-only read-only read-only read-only read-write read-write read-only current current current current current current current メーカー名"Yutaka Electric Mfg.Co.,Ltd." モデル名 UPSファームウエアバージョン SNMPエージェントバージョン UPS名 負荷装置名 バッテリステータス 1.2.2.0 1.2.3.0 1.2.4.0 1.2.5.0 1.2.6.0 1.2.7.0 1.3.1.0 1.3.2.0 1.3.3.0 1.3.3.1.0 upsSecondsOnBattery upsEstimatedMinutesRemaining upsEstimatedChargeRemaining upsBatteryVoltage upsBatteryCurrent upsBatteryTemperrature upsInputLineBads upsInputNumLine upsInputTable UpsInputentry upsBattery upsBattery upsBattery upsBattery upsBattery upsBattery upsInput upsInput upsInput upsInput 1.3.3.1.1.0 1.3.3.1.2.0 1.3.3.1.3.0 1.3.3.1.4.0 1.3.3.1.5.0 1.4.1.0 upsInputLineIndex upsInputLineFrequency upsInputLineVoltage upsInputLineCurrent upsInputLineTruePower upsOutputSource upsInput upsInput upsInput upsInput upsInput upsOutput 1.4.2.0 1.4.3.0 1.4.4.0 1.4.4.1.0 upsOutputFrequency upsOutputNumLines upsOutputTable upsOutputEntry upsOutput upsOutput upsOutput upsOutput 1.4.4.1.1.0 1.4.4.1.2.0 1.4.4.1.3.0 1.4.4.1.4.0 1.4.4.1.5.0 1.5.1.0 1.5.2.0 1.5.3.0 1.5.3.1.0 upsOutputLineIndex upsOutputVoltage upsOutputCurrent upsOutputPower upsOutputPercentLoad upsBypassFrequency upsBypassNumLines upsBypassTable upsBypassEntry upsOutput upsOutput upsOutput upsOutput upsOutput upsBypass upsBypass upsBypass upsBypass 1.5.3.1.1.0 1.5.3.1.2.0 1.5.3.1.3.0 1.5.3.1.4.0 1.6.1.0 1.6.2.0 1.6.2.1.0 upsBypassLineIndex upsBypassVoltage upsBypassCurrent upsBypassPower upsAlarmsPresent upsAlarmTable upsAlarmEntry upsBypass upsBypass upsBypass upsBypass upsAlarm upsAlarm upsAlarm 1.6.2.1.1.0 1.6.2.1.2.(index) upsAlarmId upsAlarmDescr upsAlarm upsAlarm DisplayString(SIZE(0-31)) DisplayString(SIZE(0-63)) DisplayString(SIZE(0-63)) DisplayString(SIZE(0-63)) DisplayString(SIZE(0-63)) DisplayString(SIZE(0-63)) INTEGER= unknown(1),batteryNormal(2),battery Low(3),batterydepleted(4) NonNegativeInteger PositiveInteger INTEGER(0-100) NonNegativeInteger Integer32 Integer32 Counter32 NonNegativeInteger SEUENCE OF UpsInputEntry SEQUENCE= upsInputLineIndex,upsInputLineFrequ ency,upsInputLineVoltage,upsInputLi neCurrent,upsInputLineTruePower PositiveInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger INTEGER = other(1),none(2), normal(3), bypass(4), battery(5),booster(6),reducer(7) NonNegativeInteger NonNegativeInteger SEQUENCE OF UpsOutputEntry SEQUENCE = upsOutputLineIndex,upsOutputVolta ge,upsOutputCurrent,upsOutputPow er,upsOutputPercentLoad PositiveInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger SEQUENCE OF UpsBypassEntry SEQUENCE = upsBypassLineIndex,upsBypassVolta ge,upsBypassCurrent,upsBypassPow PositiveInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger Gauge32 SEQUENCE OF UpsAlarmEntry SEQUENCE =upsAlarmId ,upsAlarmDescr,upsAlarmDescr PositiveInteger AutonomousType 1.6.2.1.3.0 1.6.3.1.0 1.6.3.2.0 1.6.3.3.0 1.6.3.4.0 1.6.3.5.0 1.6.3.6.0 1.6.3.7.0 1.6.3.8.0 1.6.3.9.0 1.6.3.10.0 1.6.3.11.0 1.6.3.12.0 1.6.3.13.0 1.6.3.14.0 1.6.3.15.0 1.6.3.16.0 1.6.3.17.0 1.6.3.18.0 1.6.3.19.0 1.6.3.20.0 1.6.3.21.0 1.6.3.22.0 1.6.3.23.0 1.6.3.24.0 1.7.1.0 upsAlarmTime upsAlarmBatteryBad upsAlarmOnBattery upsAlarmLowBattery upsAlarmDepletedBattery upsAlarmTempBad upsAlarmInputBad upsAlarmOutputBad upsAlarmOutputOverload upsAlarmOnBypass upsAlarmBypassBad upsAlarmOutputOffAsRequested upsAlarmUpsOffAsRequested upsAlarmChargerFailed upsAlarmUpsOutputOff upsAlarmUpsSystemOff upsAlarmFanFailure upsAlarmFuseFailure upsAlarmGeneralFault upsAlarmDiagnosticTestFailed upsAlarmCommunicationsLost upsAlarmAwaitingPower upsAlarmShutdownPending upsAlarmShutdownImminent upsAlarmTestInProgress upsTestId upsAlarm upsWellKnownAlarms1 upsWellKnownAlarms2 upsWellKnownAlarms3 upsWellKnownAlarms4 upsWellKnownAlarms5 upsWellKnownAlarms6 upsWellKnownAlarms7 upsWellKnownAlarms8 upsWellKnownAlarms9 upsWellKnownAlarms10 upsWellKnownAlarms11 upsWellKnownAlarms12 upsWellKnownAlarms13 upsWellKnownAlarms14 upsWellKnownAlarms15 upsWellKnownAlarms16 upsWellKnownAlarms17 upsWellKnownAlarms18 upsWellKnownAlarms19 upsWellKnownAlarms20 upsWellKnownAlarms21 upsWellKnownAlarms22 upsWellKnownAlarms23 upsWellKnownAlarms24 upsTest upsAlarmTime - - - - - - - - - - - - - - - - - - - - - - - - OBJECT IDENTIFIER TimeStamp - - - - - - - - - - - - - - - - - - - - - - - - read-write 1 / 2 ページ read-only current read-only current read-only current read-only current read-only current read-only current read-only current read-only current not-accessiblecurrent not-accessiblecurrent バッテリ運転経過時間(秒) バッテリ残量時間(分)(未使用) バッテリ残量(%) バッテリ電圧 バッテリ電流(未使用) バッテリ温度 入力電圧範囲 入力ライン相数 入力電圧ナンバーテーブル 入力ラインインデックス、入力周波数、入力電圧、入力 電流、入力電力の入力 not-accessiblecurrent read-only current read-only current read-only current read-only current read-only current 入力ラインインデックス 入力周波数 入力電圧(RMS Volt) 入力電流(0.1 RMS Amp) 入力電力(Watts) 出力状態 read-only current read-only current not-accessiblecurrent not-accessiblecurrent 出力周波数"0.1 Hertz" 出力ライン相数 出力電圧ナンバーテーブル 出力ラインインデックス、出力電圧、出力電流、出力電 力、出力負荷パーセントの入力 not-accessiblecurrent read-only current read-only current read-only current read-only current read-only current read-only current not-accessiblecurrent not-accessiblecurrent 出力ラインインデックス 出力電圧(RMS Volt) 出力電流(0.1 RMS Amp) 出力電力(Watts) 出力負荷(%) バイパス周波数"0.1 Hertz" バイパスライン相数 バイパス電圧ナンバーテーブル バイパスラインインデックス、バイパス電圧、バイパス 電流、バイパス電力の入力 not-accessiblecurrent read-only current read-only current read-only current read-only current not-accessiblecurrent not-accessiblecurrent バイパスラインインデックス バイパス電圧(RMS Volt) バイパス電流(0.1 RMS Amp) バイパス電力(Watts) アラームナンバー(発生個数) アラームテーブル アラームインデックス not-accessiblecurrent read-only current アラームID indexで示すアラーム内容が発生していればそのoid を、発生していなければ0を返す。 アラームの値は1.6.3.xxを参照。 アラーム発生時間(10mS。起動からの経過時間) バッテリ交換 バッテリ運転 ローバッテリ バッテリバックアップ時間(未対応) 温度異常 入力電圧異常 出力電圧異常 オーバロード バイパス運転 バイパス異常(未対応) 出力停止要求 UPS停止要求 充電異常(充電器異常、PFC異常) 出力停止 UPS停止 ファン異常 フューズ異常(未対応) 全体異常 診断異常(初期、インターバル、バッテリ異常) 通信エラー(未対応) 停電確認待ち(未対応) シャットダウン準備中 シャットダウン開始(未対応) テスト中 テストID current current current current current current current current current current current current current current current current current current current current current current current current current current RFC1628MIB表(140801).xls 1.7.2.0 1.7.3.0 upsTestSpinLock upsTestResultsSummary upsTest upsTest 1.7.4.0 upsTestResultsDetail upsTest 1.7.5.0 1.7.6.0 1.7.7.1.0 1.7.7.2.0 1.7.7.3.0 1.7.7.4.0 1.7.7.5.0 1.8.1.0 1.8.2.0 1.8.3.0 1.8.4.0 1.8.5.0 1.9.1.0 1.9.2.0 1.9.3.0 1.9.4.0 1.9.5.0 1.9.6.0 1.9.7.0 1.9.8.0 upsTestStartTime upsTestElapsedTime upsTestNoTestsInitiated upsTestAbortTestInProgress upsTestGeneralSystemsTest upsTestQuickBatteryTest upsTestDeepBatteryCalibration upsShutdownType upsShutdownAfterDelay upsStartupAfterDelay upsRebootWithDuration upsAutoRestart upsConfigInputVoltage upsConfigInputFreq upsConfigOutputVoltage upsConfigOutputFreq upsConfigOutputVA upsConfigOutputPower upsConfigLowBattTime upsConfigAudibleStatus upsTest upsTest upsWellKnownTests upsWellKnownTests upsWellKnownTests upsWellKnownTests upsWellKnownTests upsControl upsControl upsControl upsControl upsControl upsConfig upsConfig upsConfig upsConfig upsConfig upsConfig upsConfig upsConfig 1.9.9.0 1.9.10.0 2.1.0 upsConfigLowVoltageTransferPoint upsConfig upsConfigHighVoltageTransferPointupsConfig upsTrapOnBattery upsTraps 2.2.0 upsTrapTestCompleted upsTraps 2.3.0 2.4.0 upsTrapAlarmEntryAdded upsTrapAlarmEntryRemoved upsTraps upsTraps 2014/8/1 TestAndIncr read-write INTEGER= read-only donePass(1),doneWarning(2),doneErr or(3),aborted(4),inProgress(5),noTest sInitiated(6) DisplayString (SIZE (0..255)) read-only current current テストロック、ステータス情報表示 テスト結果 current TimeStamp TimeInterval - - - - - INTEGER =output(1),system(2) INTEGER (-1..2147483648) INTEGER (-1..2147483648) INTEGER (-1..300) INTEGER =on(1),off(2) NonNegativeInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger NonNegativeInteger INTEGER = disabled(1),enabled(2),muted(3) read-only read-only - - - - - read-write read-write read-write read-write read-write read-only read-only read-only read-only read-only read-only read-write read-write current current current current current current current current current current current current current current current current current current current current NonNegativeInteger NonNegativeInteger upsEstimatedMinutesRemaining, upsSecondsOnBattery,upsConfigLow BattTime upsTestId, upsTestSpinLock,upsTestResultsSu mmary, upsTestResultsDetail, upsTestStartTime, upsTestElapsedTime upsAlarmId, upsAlarmDescr upsAlarmId, upsAlarmDescr read-only read-only - current current current テスト結果詳細 "正常終了" "警告" "エラー" "中断" "実行中" "実行されたものなし" テスト開始時間 テスト経過時間 テストなし 進行中テスト中断 メーカの標準テスト クイックバッテリテスト バッテリキャルブレーション 停止タイプ 停止動作・停止遅延時間"seconds" 出力開始動作・出力遅延時間"seconds" Reboot時間"seconds" UPS再起動の有無 入力電圧定格"RMS Volts" 入力周波数定格"0.1 Hertz" 出力電圧定格"RMS Volts" 出力周波数定格"0.1 Hertz" 定格出力容量"Volt-Amps" 定格出力電力"Watts" バックアップ時間"minutes" UPS状態通知の可否(ブザー鳴動) 2:全ての異常、警告条件で鳴動 1:上記以外 停電検出電圧"RMS Volts" 過電圧検出電圧"RMS Volts" バッテリ運転時トラップ - current バッテリテスト完了時トラップ - - current current アラーム入力時トラップ アラーム削除時トラップ 2 / 2 ページ
© Copyright 2026 Paperzz