1 USBPIX READOUT SYSTEM USING FE-I4/A CHIP STATUS UPDATE: TOT CALIBRATION AND FINALIZATION OF TUNING PROCEDURE Jimin Kim and Austin Piehl Department of Physics University of Washington 2 Table of Contents • Comments from Collaborators • Established Goals during last week • ToT Scan and Calibration • Finalized General Tuning Procedure • What’s next? • Questions 3 Comments from Collaborators • Bill Quayle at LBL • The result does look way better, but just to point out that changing the value of Vthin_Alt_Coarse from 0 to 1 is very rarely done • Lea Caminada at LBL • N/A • David Leon at CERN • N/A 4 Established Goals Last Week • Finalization of general tuning process • ToT Scan/Calibration • Reporting the suspected bug from the software • Successful installation of 4.4.1.0 5 ToT Scan and Calibration • Charge Measurement • Pixel Detector measures the charge corresponding to the energy lost by a particle traversing a silicon sensor • The charge measurement is used to differentiate hits from the noise and also, to improve the spatial resolution of multi-pixel cluster • The charge is collected and amplified by the charge sensitive preamplifier at FE-Chip • Charge that is above the predefined threshold value is only recognized • The deposited charge is measured using the recorded Time over Threshold (ToT): the period of time during which the preamplifier output signal is above a predefined threshold • ToT increases proportionally with the deposited charge and is digitized in clock cycles of the module controller chip • These digitized ToT signal is then converted to a charge value offline using functions obtained from fit calibration data 6 ToT Scan and Calibration • ToT Calibration • To obtain a uniform and best performance for charge measurement, ToT has to be tuned to the right value which encompasses the charge of MIP ~ particles that are way more energetic than MIP • The right value of ToT should also provide a sufficient resolution • FE-I4 has 2 parameters that are used in tuning ToT and it is based on 4-bit language PrmpVbpf parameter is used for global ToT adjustment FDAC: Global and local feedback adjustment, is used for pixel by pixel ToT adjustment 7 ToT Scan (Before IF_TUNE) 8 ToT Scan (After IF_TUNE, Target ToT = 6) 9 ToT Scan (After FDAC_TUNE, Target ToT =6) 10 Finalized Tuning Procedure for FE-I4/A • Global Tuning • DIGITAL_TEST • Strobe signal is fed repeatedly straight to the discriminator • Checks digital functionality/data communication • Also masks dead and weird pixels • ANALOG_TEST • Strobe signal larger than threshold is fed repeatedly into the Analog Cell • Checks Analog functionality/data communication • THRESHOLD_SCAN • VCAL/PulsarDAC injects various charges repeatedly into the analog pixel cell • Produces the histogram of mean threshold and dispersion/S-Curve of each pixel • TOT_CALIB_VERIF • Defined reference charge is injected repeatedly • Produces the histogram of mean ToT and dispersion • GDAC_TUNE • Calibrate the global threshold value (Vthin_Alt_Fine and Vthin_Alt_Coarse) and scans threshold for each step • Gives the optimal value for Vthin_Alt_Fine and possibly, Vthin_Alt_Coarse • IF_TUNE • Calibrate global ToT value (PrmpVbpf) and scans ToT for each step • Gives the optimal value for Prmpvbpf for global ToT adjustment • Repeat from GDAC_TUNE until there is no change in dispersion and mean • Usually repeated more than once 11 Finalized Tuning Procedure for FE-I4/A • Pixel Tuning • FDAC_TUNE • Calibrate the FDAC value of each pixel to be tuned to the desired ToT value • Create an FDAC map to be loaded in cfg file for pixel by pixel ToT adjustment • TDAC_FAST_TUNE • Roughly calibrate the TDAC value of each pixel to be tuned to the desired threshold value before the Fine tuning • Create an TDAC map to be loaded in cfg file for pixel by pixel threshold adjustment • TDAC_FINE_TUNE • Finely calibrate the TDAC value of each pixel to be tuned to the desired threshold value along with threshold measurement • Create an TDAC map to be loaded in cfg file for pixel by pixel threshold adjustment • Repeat from FDAC_TUNE until there is no change is mean and dispersion • Usually repeated more than once • THRESHOLD_SCAN • To check the final tuning result for threshold calibration • ToT_CALIB_VERIF • To check the final tuning result for ToT calibraion • NOISE_SCAN • Runs at 10Khz trigger rate • Identifies pixels with too high noise occupancy and create mask for those pixels 12 Final Tuning Result • Threshold Tuning (Target Threshold = 3100e) 13 Final Tuning Result • ToT Tuning (Target ToT = 6) 14 Short update on Software version 4.4.1.0 • David Lean’s solutions • Make sure Multi IO board is recognized after uninstalling the old driver • You cannot install the new driver by right clicking on the INF file and select install • The INF file is NOT executable file, therefore has to be installed manually 15 What’s Next? • Noise Scan and Crosstalk Scan? • Disabling the column 78~80? • Successful installation of 4.4.1.0 by manual installation • Reproduction of entire tuning process from the scratch • Update TeV page once solid reproduction is successful 16 Questions for future Q/A
© Copyright 2026 Paperzz