NMEICT PROJECT Theory module: 03(MCQ) MEASUREMENT OF COLOUR: BASIC OF COLORIMETER AND SPECTROPHOTOMETER 1. Which of the following statement is incorrect regarding spectroscopy? A. Absorption spectroscopy studies radiation absorbed at various wavelengths B. Emission spectroscopy observes light emitted by atoms excited by radiation C. One of the useful applications of light scattering spectroscopy is Raman spectroscopy D. Spectroscopy studies the way non-electromagnetic radiation interacts with matter 2. The visible portion of the electromagnetic spectrum occurs between ___ nm and ___ nm. A. 1, 10 B. 10, 300 C. 400, 740 D. 800, 1200 3. Which part of the spectrophotometer is adjusted to select the desired wavelength? A. Filter B. Sample C. Light source D. Photo detector 4. In spectrophotometric experiments, the blank contains A. Solute B. Solvent C. Light source D. Absorption spectrum 5. Which of the following statement is incorrect regarding UV-visible spectrophotometry? A. It gives a measure of the amount of light absorbed by a sample B. The sample is exposed to UV-visible light of different wavelengths C. It is used to determine the concentration of a compound in solution D. The amount of UV-visible light absorbed by a sample during UV-visible spectrophotometry is called its absorbance DEVLOPMENT OF E-CONTENT ON FOUNDATION COURSE ON ANALYTICAL BIOCHEMISTRY AND SEPARATION TECHNIQUE CHRIST COLLEGE, RAJKOT, GUJARAT. Page 1 NMEICT PROJECT 6. The distance travelled by light as it passes through a cuvette is called A. Sample width B. Focal length C. Field length D. Path length 7. Which of the following statements is incorrect with respect to Beer-Lambert law? A. The amount of light absorbed is proportional to concentration of absorbing substance B. Io/I give transmittance C. Transmittance measures the amount of light transmitted after passing through the medium D. Intensity of transmitted light decreases exponentially with increase in concentration of absorbing substance 8. The plot of absorption verses wavelength for a particular compound is referred to as the A. Path length B. Emission spectrum C. Absorption spectrum D. None of these 9. Which of the following is not a limitation of Beer- Lambert law? A. Light must be of a narrow wavelength range and preferably monochromatic B. At high concentration, molecules may polymerize and thereby affecting absorption of solution C. Presence of fluorescent molecule in solution may interfere in the final absorbance of solution D. Beer- Lambert law does not form the quantitative basis for all types of absorption spectroscopy 10. The photomultiplier tube is a widely used ---------------in UV-Vis spectroscopy A. B. C. D. Wavelength selector Detector Signal processors Cuvette DEVLOPMENT OF E-CONTENT ON FOUNDATION COURSE ON ANALYTICAL BIOCHEMISTRY AND SEPARATION TECHNIQUE CHRIST COLLEGE, RAJKOT, GUJARAT. Page 2 NMEICT PROJECT Theory module: 03 (Assignment) MEASUREMENT OF COLOUR: BASIC OF COLORIMETER AND SPECTROPHOTOMETER 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. What is the difference between spectrophotometer and colorimeter? What is spectrophotometry? What are the limitations of spectrophotometers? What is colorimeter? What is the definition of a color? What is electromagnetic radiation? Define Beer Lambert laws? What are the limitations of Beer Lambert laws? What are the important parts of colorimeter and spectrophotometer? What are the source of light in spectrophotometer and colorimeter? What is complementary color? What is complementary wavelength? What is monochrome and polychromatic light? What are the types of cuvette used in spectrophotometer? What are the types of detectors used in spectrophotometer? DEVLOPMENT OF E-CONTENT ON FOUNDATION COURSE ON ANALYTICAL BIOCHEMISTRY AND SEPARATION TECHNIQUE CHRIST COLLEGE, RAJKOT, GUJARAT. Page 3 NMEICT PROJECT Theory module: 03 (References) MEASUREMENT OF COLOUR: BASIC OF COLORIMETER AND SPECTROPHOTOMETER Principles and techniques of biochemistry and molecular biology. Sixth edition. Edited Keith Wilson & John Walker. Cambridge University press Analytical biochemistry and separation techniques. – A laboratory manul for B.Sc and M.Sc students. Palanivelu, Introductory practical biochemistry. Edited by S.K Sawhney & Randhir Singh . Narosa Publishing house Pvt Ltd. http://teaching.shu.ac.uk/hwb/chemistry/tutorials/molspec/uvvisab3.htm DEVLOPMENT OF E-CONTENT ON FOUNDATION COURSE ON ANALYTICAL BIOCHEMISTRY AND SEPARATION TECHNIQUE CHRIST COLLEGE, RAJKOT, GUJARAT. Page 4 NMEICT PROJECT Theory module: 03 (Edutainment) MEASUREMENT OF COLOUR: BASIC OF COLORIMETER AND SPECTROPHOTOMETER DEVLOPMENT OF E-CONTENT ON FOUNDATION COURSE ON ANALYTICAL BIOCHEMISTRY AND SEPARATION TECHNIQUE CHRIST COLLEGE, RAJKOT, GUJARAT. Page 5 NMEICT PROJECT Across 41. the act of checking or adjusting (by comparison with a standard) the accuracy of a measuring instrument 16. When a parallel beam of monochromatic light passes through an absorbing medium, the amount of light that is absorbed is directly proportional to the number of light absorbing molecules or the concentration of the medium. Name the law 59. Spectrophotometer uses the deuterium or a ________________ lamp for uv light. 5. A spectrophotometer uses a________to separate light and a colorimeter uses filters. 66. When a parallel beam of monochromatic light passes through an absorbing medium, the amount of light that is absorbed is directly proportional to the length the medium through which the light passes. Give the name of this law 84. _____________ spectrum consist of wide range of radiations ranging from gamma rays and x-rays from one end and radio and television waves to other end. 23. It is a device that measures the intensity of the light before and after it has passed through a coloured solution 74. Cuvettes for uv range is made up of Down 1. When a coloured solution absorbs light maximally at a particular wavelength then that wavelength is known as ________________ wavelenght. 41. The containers for the sample and reference solution in spectrophotometer 2. Which part of the spectrophotometer is adjusted to select the desired wavelength? 12. It is an optical device that transmits a mechanically selectable narrow band of wavelengths of light or other radiation chosen from a wider range of wavelengths available at the input. 18. Light source in colorimeter = ______________ lamp 56. It converts the transmitted light energy in to electrical energy. 81. The distance travelled by light as it passes through a cuvette is called _________ length DEVLOPMENT OF E-CONTENT ON FOUNDATION COURSE ON ANALYTICAL BIOCHEMISTRY AND SEPARATION TECHNIQUE CHRIST COLLEGE, RAJKOT, GUJARAT. Page 6
© Copyright 2025 Paperzz