S L I P- R E TA R D A N T F L O O R I N G SAFETY ZONE ™ Sheet & Tile SRF Product Structure SAFETY ZONE™ SHEET Slip-Retardant Flooring Exclusive Textured, Particle-Enhanced Surface Through-Pattern Wear Layer Fiberglass Layer Textured Cellulose Backing SAFET Y ZONE™ TILE Slip-Retardant Flooring Exclusive Textured, Particle-Enhanced Surface Through-Pattern Wear Layer Safety Zone Sheet 31500 saddle ™ Medintone Homogeneous Sheet H8303 almost black ™ Lasting Performance Where Slip-Retardant Performance Matters Healthcare and education facilities have an extraordinary responsibility to protect the health and well-being of occupants with an environment that is clean, comfortable, dry and safe. With Armstrong Safety Zone Sheet and Safety Zone Tile, you have two quality options for areas that require an extra measure of safety. ® ™ ™ The composition of Safety Zone Sheet provides dynamic underfoot safety, activating when compressed to supply sure-grip texture underfoot. And the through-pattern wear layer construction means the slip-retardant performance of Safety Zone Sheet won’t wear off, standing up to the heaviest traffic for the lifetime of the floor. The lasting slip-retardant performance, embossed surface for improved maintenance, and design flexibility of Safety Zone Sheet makes it the smart, effective solution for today’s commercial environments. Safety Zone Sheet is a safety floor without compromise – in performance, value, and style. 3 How Safety Zone Sheet Works ™ Smooth floors, in areas that require an additional measure of slip-retardant performance, are easy to clean but may not provide adequate traction underfoot. Rough floors offer additional traction, but are much harder to clean. The unique construction of Safety Zone Sheet combines the benefits of both. In its normal state, it is smooth enough for easy cleaning; however, when pressure is applied from walking, it becomes rough, providing dynamic traction. ™ Superior Durability, Through and Through The through-pattern wear layer of Safety Zone Sheet gives it an advanced level of durability and a longer effective lifespan. The aluminum oxide and quartz particles which give Safety Zone Sheet its slip-retardant performance go all the way through the wear layer. The silicon carbide particles throughout the surface layer provide additional initial grab when applying walking pressure. ™ Quartz Aluminum Oxide Fiberglass Layer Textured Cellulose Backing Safety Zone Sheet 31501 smoky 31507 mountain top ™ 4 Silicon Carbide Safety Zone Tile 57002 weathered alabaster 57004 slate black ™ Safety Zone Tile Modular Designs with Added Safety ™ Armstrong Safety Zone Tile offers a modular 12” x 12” tile option for slip-retardant safety flooring. Like Safety Zone Sheet, it features a through-pattern wear layer construction for lasting performance and scuff resistance under heavy traffic conditions. The embossed surface is embedded with proprietary particles for slip-retardant performance. ® ™ ™ Safety Zone Tile features our exclusive Fast Start Factory Finish which protects the tile surface during installation and makes initial maintenance quick and easy. It is an ideal choice for adding an extra measure of safety in areas where traditional maintenance protocols using polish are followed, since we recommend the application of polish and periodic restorative maintenance procedures for our Safety Zone Tile. ® The stain resistance of Safety Zone Tile can be enhanced with the addition of Armstrong S-495 Commercial Floor Sealer. ® NOTE: No standing water; walk-off mats required. 5 Targeted Designs for Freedom and Flexibility Safety Zone Sheet is available in a select color palette designed specifically to reflect current trends in healthcare, education, retail and other space interiors, and coordinates beautifully with other sheet products in the Armstrong Commercial Flooring portfolio. ™ ® The compatibility of Safety Zone Sheet with our full line of Armstrong Homogeneous, Heterogeneous and Linoleum sheet products means designers and building owners can integrate safety flooring in key areas without compromising the overall design intent of the space. Safety Zone Tile enables unique modular designs with creative combinations of colors and spot-color accents. Our palette coordinates well with Armstrong Vinyl Composition Tile for complementary designs in adjacent spaces. ™ ® With safety flooring solutions in both sheet and tile, the design options are greater than ever before. Safety Zone Sheet adds slip-retardant performance in front of food service counters while coordinating beautifully with the Heterogeneous Rejuvenations Sheet that extends into the dining area. ™ ™ Safety Zone Sheet 31502 outer space ™ Rejuvenations Heterogeneous Sheet StoneRun 34330 lithos andesite ™ ™ 6 Flooring Recommendation Guide Use Safety Zone Sheet or Tile to add an extra measure of safety and style in the following spaces. Contact your Armstrong Representative to discuss other appropriate spaces for safety sheet and tile. ™ Safety Safety Zone Sheet Safety Zone Tile Cafeteria, Dining Area (a) • • Commercial Parking Garages Walkways • • Corridors • • Dry Physical Therapy • • Elevators • • Emergency Room Entrance Areas • • Physical Therapy • • Laboratories (c) • • Ramps/Ramped Corridors (Dry) • • Scrub Areas (b) • Utility/Storage Room • • Vestibules/Entryways/Foyers (b) • • Cafeteria, Dining Area (a) • • Commercial Parking Garages Walkways • • Corridors • • Elevators • • Food Service Area (a) (b) • • Laboratories(c) • • Lavatories (b) • • Locker Rooms (No Spikes) (b) • • Ramps/Ramped Corridors (Dry) • • Utility/Storage Room • • Vestibules/Entryways/Foyers (b) • • ™ ™ Healthcare Education (a) These floors are not recommended for wet areas such as commercial kitchens, commercial food processing areas, behind fast-food counters, shower rooms and whirlpools/spas. (b) No standing water; walk-off mats required. (c) Not recommended in laboratories that require special decontamination procedures on surfaces, including floors. For additional space recommendations, please refer to the Armstrong Product Guide. 7 SAFETY ZONE SHEET ™ Slip-Retardant Flooring breeze 31504 31500 Weld Rod - WS005 mountain top 31507 31503 smoky 31506 outer space 31505 Weld Rod - WS003 Safety Zone Sheet requires no sealing, buffing, stripping, polishing, or restorative maintenance. Polish should not be used on Safety Zone Sheet. ™ 8 oceans Weld Rod - WS007 Weld Rod - WS002 31502 ecotone Weld Rod - WS004 Weld Rod - WS008 31501 saddle Weld Rod - WS001 grasslands Weld Rod - WS006 SAFETY ZONE TILE ™ Slip-Retardant Flooring 57002 weathered alabaster 57001 shale gray 57000 earth stone 57005 stone beige 57006 cobblestone peach 57008 soft cedar 57003 patina green 57009 forest floor 57012 dark basil 57007 babbling brook 57010 river rock 57004 slate black Safety Zone Tile is an ideal safety solution for spaces where polish and restorative maintenance are required, making traditional maintenance protocols consistent and efficient. ™ 9 Safety Zone Sheet & Tile ™ Worry-free Installation Safety Zone Sheet installs just like traditional Armstrong sheet products — no special tools or techniques required. The formulation makes the flooring more flexible and easier to handle, and the textured cellulose backing helps to provide adhesion when combined with the adhesive, even in high-moisture environments. Just install with Armstrong recommended adhesives: S-543 High-Moisture, S-599 Premium, S-240 Epoxy or Flip Spray Adhesive. Our weld rod colors add the finishing touch to the overall design, whether you use them to coordinate or contrast based on design intent. ™ ® ® Adhesives Flip Spray Adhesive ® • High-moisture guarantee • Warranted for heavy rolling loads • Simple one-step application process • Open time: varies depending on adhesive coverage • Working time: should not exceed 4 hours • Spread rate: L VT and Commercial Sheet: 140–170 sq. ft./bottle; VCT: 170–200 sq. ft./bottle S-240 Epoxy Adhesive • Great for heavy loads • Can be used on multiple substrates • Open time: 10–20 minutes • Working time: 60 minutes • Spread rate: 170–190 sq. ft./gal. (fine notch) S-543 Commercial Sheet Flooring and LVT Adhesive • High-moisture guarantee • Reduced need for moisture remediation • Open time: 10–20 minutes over porous, 30+ minutes over non-porous • Working time: 8 hours after dry to touch • Spread rate: 225–275 sq. ft./gal. (fine notch) S-599 Vinyl Sheet Adhesive Premium Commercial • Strong bond and shear strength • Can be used for vinyl-, glass- and felt-backed sheet • Open time: 10–20 minutes over porous, 30+ minutes over non-porous • Working time: 60 minutes after dry to touch • Spread rate: 250–300 sq. ft./gal. (fine notch) S-515 Floor Tile Adhesive • High moisture guarantee • Can also be used over cutback adhesive residue • Dries clear to easily see chalk lines • Open time: 30+ minutes • Working time: 24 hours • Spread rate: 285–335 sq. ft./gal. (fine notch) S-525 Bio-flooring Adhesive • High moisture guarantee • Can also be used over cutback adhesive residue • Water-resistant when fully cured • Open time: Minimum of 20 minutes or until dry-to-touch • Working time: 24 hours • Spread rate: 275–325 sq. ft./gal. Trowel: fine notch S-750 Premium Floor Tile Adhesive • Can also be used over cutback adhesive residue • Can be used as a primer • Open time: 30+ minutes • Working time: 6 hours • Spread rate: 350–400 sq. ft./gal. (fine notch) S-700 Floor Tile Adhesive Thin Spread • Black asphalt adhesive • Can also be used over cutback adhesive residue • Can be used over metal subfloors • Open time: 30+ minutes • Working time: 18 hours • Spread rate: 350–400 sq. ft./gal. (fine notch) 10 S&T SHEET & TILE High-Moisture 22 oz. Bottle 93% RH S&T Epoxy SHEET & TILE 1/2 Gallon 1 Gallon 90% RH 8 lbs. MVER S High-Moisture SHEET 1 Gallon 4 Gallon 90% RH 5 lbs. MVER for Sheet 7 lbs. MVER for LVT S High-Moisture SHEET 1 Gallon 4 Gallon 85% RH 5 lbs. MVER T High-Moisture TILE 90% RH 7 lbs. MVER T High-Moisture TILE 1 Quart 1 Gallon 4 Gallon 1 Gallon 4 Gallon 90% RH 7 lbs. MVER T Premium TILE 1 Gallon 4 Gallon 80% RH 5 lbs. MVER T Standard TILE 80% RH 5 lbs. MVER 1 Gallon 4 Gallon Safety Zone Sheet & Tile ™ Cleaner Floors with Minimal Disruption Safety Zone Sheet is a low-maintenance solution* that is suitable for a multitude of spaces, enabling the maintenance staff to quickly and easily clean the floors with minimal disruption. The de-aerated construction and non-porous surface prevents dirt from penetrating the surface. No sealing, buffing, stripping, polishing, or restorative maintenance needed. Ever. ™ *Polish should not be used on Safety Zone Sheet to retain its safety features. There When You Need It Safety Zone Tile is made in the U.S.A. with global and domestic content. Safety Zone Sheet is stocked in Lancaster, Pennsylvania. Both are readily available for your next project. ™ ™ Here When You Need Us Armstrong believes in creating customers for life. Our 150-year history of providing innovative products and reliable service is part of every floor. For information and assistance before, during, and after your project, contact your Armstrong sales rep, distributor or contractor. Learn more at ArmstrongFlooring.com/commercial. Safety Zone Sheet 31504 breeze 31502 outer space ™ 11 S L I P- R E TA R D A N T F L O O R I N G SAFETY ZONE Sheet & Tile ™ Materials and Construction Static Load Limit Sheet - An embossed, slip-retardant wear layer with mineral aggregates on saturated glass fiber backing. Mineral aggregates are dispersed uniformly throughout the thickness of the wear layer. Color pigments are insoluble in water and resistant to cleaning agents and light. Tile - An embossed tile composed of polyvinyl chloride resin, plasticizers, stabilizers, fillers and mineral aggregate. Protected by an acrylic factory finish, the color detail is dispersed throughout the thickness of the product. Color pigments are insoluble in water and resistant to cleaning agents and light. Sheet - A STM F970 250 lbs./sq. in. (17.6 kg/cm ) <0.005 in. residual indentation Tile - A STM F 970 125 lbs./sq. in. (8.79 kg/cm ) <0.005 in. residual indentation NOTE: Floors should be protected from sharp-point loads and heavy static loads. High-heeled traffic [1000 psi (70.3 kg/cm ) or more] may visibly damage wood, resilient and other floor coverings. For questions regarding product suitability and detailed instructions for floor preparation and installation in these applications, please contact Armstrong. 2 2 2 Fire Test Data Size Sheet - 6 ft. 7 in. (2.0 m) wide; up to 66 ft (20 m) long Tile - 12 in. x 12 in. (305 mm x 305 mm) Gauge (nominal thickness) Sheet - 0.080 in. ( 2.0 mm) overall (nominal) 0.060 wear layer (nominal) Tile - 1/8 in. (3.2 mm) overall Limitations Safety Zone Sheet and Tile should not be used in the following areas: • Hospital operating rooms. • Heavy industrial and exterior areas. • Commercial kitchens and commercial food processing areas. • Where pointed spikes such as golf or track shoes will be used. • Around swimming pools. • Wet areas, standing water (shower rooms, whirlpools/spas) NOTE: Concentrated static and dynamic loads such as hospital beds, rollout bleachers, portable x-ray machines, etc., may visibly damage resilient as well as other types of floor coverings. For questions regarding product suitability and detailed instructions for floor preparation and installation in these applications, please contact Armstrong. ™ Suitable for Application Over Sheet and Tile •Concrete, terrazzo, and other dry, structurally sound monolithic subfloors, which are suspended, on grade, or below grade. •Suspended wood subfloor construction with approved wood underlayments, and a minimum of 18 in. (45.72 cm) well-ventilated air space below. •Most metal floors and most existing single-layer resilient floors on approved underlayments. •Radiant-heated subfloors with a maximum surface temperature of 85˚ F (29˚ C). Unsuitable for Application Over Sheet and Tile • Subfloors where excessive moisture or alkali is present. • Sleeper-constructed wood subfloors, on grade or below grade. •Lightweight aggregate concrete subfloors having a density of less than 90 lbs. per cu. ft. (1442 kg/m ) or cellular concrete having a plastic (wet) density less than 100 lbs. per cu. ft. (1602 kg/m ) [94 lbs. per cu. ft. (1506 kg/m ) dry weight], or concrete having a compressive strength of less than 3500 psi (24 MPa). Concrete slabs with heavy static and/ or dynamic loads should have higher design strengths and densities calculated to accommodate such loads. 3 3 3 Concrete curing agents, sealers, hardeners, or parting agents should be removed. TECHNICAL DATA Shipping Weight Sheet - 4.5 lbs. /sq. yd. (2.44 kg /sq. m) Tile - 61 lbs./carton (27.7 kg); 45 tiles/carton Gloss (typical value) Sheet - 60 degree specular, Approximately 11-15 Tile - 60 degrees specular, 3-5 International Specifications Sheet - ASTM F 1303, Type II, Grade 1 Class A Backing Tile - ASTM F 1066; Class 2 – through-pattern Sheet and Tile ASTM E 648 Flooring Radiant Panel Critical Radiant Flux – 0.45 watts/cm or more – Class I ASTM E 662 Smoke Chamber Specific Optical Smoke Density – 450 or less Sheet CAN/ULC-S102.2: Flame Spread Rating – 75, Smoke Developed Classification - 120 Tile CAN/ULC-S102.2: Flame Spread Rating – 0, Smoke Developed Classification - 30 Numerical flammability ratings alone may not define the performance of the product under actual fire conditions. These ratings are provided only for use in the selection of products to meet the specified limits. 2 INSTALLATION Job Conditions Subfloors/underlayments shall be dry, clean and smooth. They shall be free of dust, solvents, varnish, paint, wax, oil, grease, residual adhesive, adhesive removers, permanent markers and other foreign materials that might affect the adhesion of resilient flooring or cause a discoloration of the flooring from below. Spray paints, permanent markers and other indelible ink markers must not be used to write on the back of the flooring material or used to mark the concrete slab as they could bleed through, telegraphing up to the surface and permanently staining the flooring material. If these contaminants are present on the substrate they must be mechanically removed prior to the installation of the flooring material. For more detailed requirements of concrete, wood and metal subfloors, as well as trowelable and wood underlayments, refer to the installation instructions at armstrong.com. Moisture testing must be performed on all concrete slabs regardless of their age or grade level including areas where resilient flooring has already been installed. Moisture Vapor Emission Rate (MVER) using Calcium Chloride (ASTM F1869) and/or percent internal relative humidity (ASTM F 2170) tests must be conducted in strict accordance with the most current edition of the ASTM test method. Following are the Armstrong maximum allowable moisture limits: •W hen using S-515 or S-525 Adhesive, moisture test results shall not exceed a MVER of 7.0 lbs./1000 sq. ft./24 hours per ASTM F 1869 and/ or 90% RH per ASTM F 2170. •W hen using S-700 or S-750 Adhesives, moisture test results shall not exceed a MVER of 5.0 lbs./1000 sq. ft./24 hours per ASTM F 1869 and/ or 80% RH per ASTM F 2170. •W hen using Flip Spray Adhesive, moisture test results shall not exceed 93% RH per ASTM F 2170. • When using S-599 Adhesive, moisture test results shall not exceed a MVER of 5.0 lbs. /1000 sq. ft. /24 hours per ASTM F 1869 and/or 85% RH per ASTM F 2170. • When using S-543 Adhesive, moisture test results shall not exceed a MVER of 5.0 lbs. /1000 sq. ft. /24 hours per ASTM F 1869 and/or 90% RH per ASTM F 2170. • When using S-240 Adhesive, moisture test results shall not exceed a MVER of 8.0 lbs. /1000 sq. ft. /24 hours per ASTM F 1869 and/or 90% RH per ASTM F 2170. On installations where both the Moisture Vapor Emission Rate and percent internal relative humidity tests are conducted, results for both tests shall comply with the allowable limits listed above. Before installation concrete floors should also be tested for pH following procedures in ASTM F 710. When testing for pH, the allowable readings for the installation of Armstrong flooring are 5 to 9 when using S-599, S-700, S-750 or S-240 and 5 to 11 when using Flip Spray Adhesive, S-543, S-515. Bond Tests should also be conducted for compatibility with the substrate. Temperature shall be maintained at a minimum of 65° F(18° C) and a maximum of 100° F (38° C) for 48 hours prior to installation, during installation and 48 hours after completion when using S-599 or S-543. When using S-240, the temperature shall be maintained at a minimum of 65° F(18° C) and a maximum of 85° F (29° C) for 48 hours prior to ® installation, during installation and 48 hours after completion. A minimum temperature of 55° F (13° C) shall be maintained thereafter. Condition all flooring materials and adhesives to room temperature for at least 48 hours prior to starting installation. Protect all materials from the direct flow of heat from hot-air registers, radiators, or other heating fixtures and appliances. Procedure Sheet Safety Zone Sheet must be installed full spread using Armstrong S-599 Adhesive or S-543 High Moisture Adhesive or S-240 Epoxy. It may also be installed using the Perimeter Plus Method using S-599 or S-543 in field areas with a 3-inch band of S-240 Epoxy around the perimeter of the room. In all cases there is the option to use S-580 Adhesive in flash cove areas. Seams must be heat welded. Refer to the Armstrong Guaranteed Installation Systems manual (F-5061) at ArmstrongFlooring. com/installationmanual and at floorexpert.com for proper installation, care and maintenance information. Tile Over concrete, ceramic, marble, terrazzo and approved wood underlayments, Safety Zone Tile must be installed using Armstrong S-515, S-525, S-700, S-750, S-240 Epoxy Adhesive or Flip Spray Adhesive. Over steel, stainless steel, aluminum and lead install with S-700 or S-240 Epoxy Adhesive. Over existing resilient flooring or the Tile-On System, install with S-515, S-525, S-750 or S-240 Epoxy Adhesive. When installing Safety Zone Tile in produce areas, around freezers, at entry ways, and other areas subject to surface water or cooler temperatures, install the first 3 to 5 rows with S-240 Epoxy. Other rows may be installed with S-515, S-525, and S-700 or S-750 Adhesives. Refer to the Armstrong Guaranteed Installation Systems manual (F-5061) at ArmstrongFlooring.com/installationmanual and at floorexpert.com for proper installation, care and maintenance information. ® ® MAINTENANCE Sheet - Safety Zone Sheet is a low-maintenance solution that is suitable for a multitude of spaces. No sealing, buffing, stripping, polishing or restorative maintenance needed. Polish should not be used on Safety Zone Sheet to retain its safety features. Initial Maintenance Immediately After Installation: • Sweep or vacuum thoroughly. • Do not wash, scrub or strip the floor for at least five days after installation. • Damp mop with a dilute neutral detergent solution such as Armstrong S-485 Floor Cleaner, carefully wiping up black marks and excessive soil. • Protective floor polishes, sealer or other site-applied finishes are not recommended and should not be used as they will affect the floor’s slip-retardant properties. Tile - Safety Zone Tile features our exclusive Fast Start Factory Finish which protects the tile surface during installation and makes initial maintenance quick and easy. We recommend the application of polish and periodic restorative maintenance procedures. Initial Maintenance Immediately After Installation: • Sweep or vacuum thoroughly. •D amp mop with a properly diluted neutral detergent solution such as Armstrong S-485 Floor Cleaner – carefully wiping up black marks and excessive soil. • S afety Zone Tile requires two coats of high-quality commercial floor polish such as Armstrong S-480 Floor Polish to protect the floor until regular maintenance procedures can be started. •D o not wash, scrub or strip the floor for at least four days after installation. Preparation for Commercial Use: For specific, ongoing maintenance procedures, see Armstrong Commercial Resilient Flooring Maintenance Recommendations booklet, F-8663. ™ ™ ® WARRANTIES Armstrong warrants its regular (first quality) Safety Zone Sheet and Tile commercial floors to be free from manufacturing defects and warrants the installation integrity for five years from the date of purchase, if installed according to the Armstrong Guaranteed Installation Systems, manual, F-5061. This warranty extends only to the original end-user. See Armstrong Commercial Floor Warranty, F-3349 or visit ArmstrongFlooring. com/commercial for warranty details, limitations and exclusions. ® ® ArmstrongFlooring.com/commercial | 1 888 276 7876 ISO 9001 Quality Management Standard FP7440F9362-317 Printed in United States of America. © 2017 AFI Licensing LLC The Armstrong logo and Armstrong are trademarks of AWI Licensing LLC. All other marks are trademarks of Armstrong Flooring, Inc., or its subsidiaries. ®
© Copyright 2026 Paperzz