NEW MHM Multisplit system heat pumps MultiSplit System with powers from 4.1 up to 11.6 kW with Inverter R410A x1 Dualsplit MHM_W x2 Dualsplit Remote control x3 Trialsplit Remote control x4 MHM_FS Quadrisplit MHM_C x5 MHM_CS Pentasplit MHM_F Wired control panel = MHM_W MHM_C MHM_CS MHM_D MHM_F MHM_FS Remote control MHM_D MHM Features Dualsplit: • MHM42, MHM52 and MHM72 outdoor units that can be coupled to 1 or 2 indoor unit Trialsplit: • MHM73 outdoor unit can be coupled to 2 or 3 indoor units Quadrisplit: • MHM84 and MHM104 outdoor unit can be coupled to 2, 3 or 4 indoor units Pentasplit: • MHM125 outdoor unit can be coupled to 3, 4 or 5 indoor units Indoor units selected from: • Wall (Wall installation) with remote control: MHM 20W - 25W - 35W - 50W • Cassette 600x600 (Suspended ceiling installation) with remote control and wired control panel: MHM 35CS - 50CS (coupling with the MHMGL40S accessory is mandatory) • Cassette 840x840 (Suspended ceiling installation) with remote control and wired control panel: MHM 35C - 50C - 70C (coupling with the MHMGL40 accessory is mandatory) • Floor Ceiling (Wall and/or ceiling installation) with remote control and wired control panel: MHM 25F - 35F - 50F - 70F • Ducted (Orizontal installation only) with remote control and wired control panel: MHM 25D - 35D - 50D - 60D - 70D • Console (Vertical installation only) with remote control: MHM 25FS - 35FS - 50FS • R410A refrigerant gas • Inverter device for large energy saving and optimisation of environment conditions • Indoor unit with 3 speed fan • Multi-speed single-fan external units • Variable speed rotary compressor • Air flow louvered fins with horizontal adjustment facility (MHM_W, MHM_C, MHM_CS, MHM_F, MHM_FS) • Air flow louvered fins with horizontal adjustment facility Motorized louver for vertical adjustment of outlet air flow direction (MHM_W, MHM_C, MHM_ CS, MHM_F, MHM_FS) • Silent functioning • Infrared ray remote control with liquid crystal display wired control panel for checking all functions • Wired control panel with liquid crystal display for checking all functions (MHM_C, MHM_CS, MHM_D, MHM_F) • Microprocessor control • Possibility to set the room temperature probe in intake of the indoor unit or in the wired control panel (MHM_C, MHM_CS, MHM_D, MHM_F) • Timer for programming switch-off or switchon • Cooling, heating, dehumidifying, fan only automatic functioning programs (heating/cooling) • Self-diagnostics function • Air filter with easy extraction and cleaning • Efficient defrosting contro • Standard supply condensate drain pump in the MHM_C, MHM_D versions • Refrigerant lines with flared connections • Systems with multi-line refrigerant connections, where every indoor unit is connected to the outdoor unit via dedicated refrigerant lines • Total length of the refrigerant lines: up to 20m for the outdoor units MHM42, MHM52 e MHM72 up to 70m for the outdoor units MHM73, MHM84 e MHM104 up to 80m for the outdoor units MHM125 Accessories • MHMGL40S: (600x600) MHMGL40: (840x840) Air flow and recovery grid. The flow louvers Mod. MHMGL40S MHMGL40 are powered. Equipped with infrared receiver and emergency functioning key. It is a mandatory accessory as the MHM_C and MHM_ MHM35CS MHM50CS ✔ ✔ CS units are delivered without. MHM35C MHM50C MHM70C ✔ ✔ ✔ Allowed combinations of indoor units MHM_C - MHM_CS - MHM_D - MHM_F - MHM_FS - MHM_W indoor units: Dualsplit MHM 42 (14k) outdoor unit Dualsplit: the installation of 1 or 2 indoor units is possible Dualsplit MHM 52 (18k) outdoor unit Dualsplit MHM 72 (24k) outdoor unit Total (k) Unit A Unit B Total (k) Unit A Unit B Total (k) Unit A Unit B 7 9 12 20 (7k) 25 (9k) 35 (12k) 20 (7k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) 25 (9k) 7 9 12 14 16 20 (7k) 25 (9k) 35 (12k) 20 (7k) 20 (7k) 20 (7k) 25 (9k) 14 16 18 19 21 20 (7k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) 25 (9k) 35 (12k) 35 (12k) 18 25 (9k) 25 (9k) 24 35 (12k) 35 (12k) 19 21 20 (7k) 25 (9k) 35 (12k) 35 (12k) 25 27 30 20 (7k) 25 (9k) 35 (12k) 50 (18k) 50 (18k) 50 (18k) 14 16 18 Total (k) 14 16 18 19 21 24 25 27 30 36 21 23 Total (k) 14 16 18 19 21 24 25 27 30 36 21 23 25 26 27 28 30 31 32 33 Unit A 20 (7k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) 35 (12k) 20 (7k) 25 (9k) 35 (12k) 50 (18k) 20 (7k) 20 (7k) Unit A 20 (7k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) 35 (12k) 20 (7k) 25 (9k) 35 (12k) 50 (18k) 20 (7k) 20 (7k) 20 (7k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) 20 (7k) 20 (7k) 25 (9k) Trialsplit: it is mandatory to install at least 2 indoor units for correct system functioning Trialsplit MHM 73 (24k) outdoor unit Unit B Unit C Total (k) Unit A 20 (7k) 25 20 (7k) 25 (9k) 26 20 (7k) 25 (9k) 27 25 (9k) 35 (12k) 28 20 (7k) 35 (12k) 30 25 (9k) 35 (12k) 31 20 (7k) 50 (18k) 32 20 (7k) 50 (18k) 33 25 (9k) 50 (18k) 34 20 (7k) 50 (18k) 36 25 (9k) 20 (7k) 20 (7k) 36 35 (12k) 20 (7k) 25 (9k) Unit B Unit C 25 (9k) 25 (9k) 20 (7k) 25 (9k) 25 (9k) 25 (9k) 35 (12k) 20 (7k) 35 (12k) 25 (9k) 25 (9k) 35 (12k) 35 (12k) 25 (9k) 35 (12k) 35 (12k) 35 (12k) 50 (18k) 35 (12k) 50 (18k) 50 (18k) 35 (12k) Quadrisplit: it is mandatory to install at least 2 indoor units for correct system functioning Quadrisplit MHM 84 (28k) outdoor unit Unit B Unit C Unit D Total (k) Unit A Unit B 20 (7k) 34 20 (7k) 25 (9k) (25 (9k) 36 25 (9k) 25 (9k) 25 (9k) 36 35 (12k) 35 (12k) 35 (12k) 37 20 (7k) 35 (12k) 35 (12k) 39 25 (9k) 35 (12k) 35 (12k) 42 35 (12k) 35 (12k) 50 (18k) 28 20 (7k) 20 (7k) 50 (18k) 30 20 (7k) 20 (7k) 50 (18k) 32 20 (7k) 20 (7k) 50 (18k) 33 20 (7k) 20 (7k) 20 (7k) 20 (7k) 34 20 (7k) 25 (9k) 20 (7k) 25 (9k) 35 20 (7k) 20 (7k) 25 (9k) 25 (9k) 36 25 (9k) 25 (9k) 20 (7k) 35 (12k) 37 20 (7k) 25 (9k) 25 (9k) 25 (9k) 38 20 (7k) 20 (7k) 25 (9k) 35 (12k) 39 20 (7k) 20 (7k) 25 (9k) 35 (12k) 39 25 (9k) 25 (9k) 35 (12k) 35 (12k) 40 20 (7k) 25 (9k) 20 (7k) 50 (18k) 41 20 (7k) 20 (7k) 35 (12k) 35 (12k) 42 25 (9k) 25 (9k) Quadrisplit MHM 104 outdoor unit (36k) Total power connectable to the outdoor unit between 50% and 150% of its rated power (36k) Pentasplit: it is mandatory to install at least 3 indoor units for correct system functioning Pentasplit MHM 125 outdoor unit (42k) Total power connectable to the outdoor unit between 50% and 150% of its rated power (42k) Unit C 50 (18k) 50 (18k) 35 (12k) 50 (18k) 50 (18k) 50 (18k) Unit D - 20 (7k) 20 (7k) 20 (7k) 25 (9k) 20 (7k) 25 (9k) 25 (9k) 25 (9k) 25 (9k) 35 (12k) 20 (7k) 25 (9k) 35 (12k) 25 (9k) 35 (12k) 25 (9k) 25 (9k) 35 (12k) 25 (9k) 35 (12k) 25 (9k) 35 (12k) 35 (12k) 50 (18k) 35 (12k) 35 (12k) 50 (18k) 35 (12k) Technical data Outdoor units MHM (nominal) W (min-max) W (nominal) W (min-max) W/W Cooling capacity Total input power EER *** Energy efficient class (nominal) (min-max) (nominal) (min-max) Heating capacity Input power COP *** Energy efficient class Compressor Sound Pressure Max number of units that can be connected Power Supply 42 4100 52 5000 72 7000 2050-4700 2050-6200 2700-8200 1150 1550 2180 2200 2480 3030 3590 500-2000 500-2250 750-4300 650-4500 650-4500 680-4500 850-5000 3.57 A 4500 3.23 A 5600 3.21 A 7700 3.21 A 8500 3.23 A 9300 3.23 A 11000 3.23 A 13000 2500-5500 2500-6650 3500-9500 1180 1540 2260 2350 2550 3010 3545 580-2000 580-2700 1000-4400 980-3950 980-3950 1500-4800 1600-4800 3.81 A 3.63 A 3.63 A 3.65 A 3.67 A dB (A) 56 57 59 54 54 n. 2 2 4 4 5 W W W W W/W Models Liquid refrigerant connections / Pipes Gas refrigerant connections / Pipes Models Liquid refrigerant connections / Pipes Gas refrigerant connections / Pipes Models Liquid refrigerant connections / Pipes Gas refrigerant connections / Pipes Models Liquid refrigerant connections / Pipes Gas refrigerant connections / Pipes Models Liquid refrigerant connections / Pipes Gas refrigerant connections / Pipes 104 9790 125 11600 2200-10000 2200-10000 2900-10700 2980-12350 3600-11000 2800-11000 3050-11360 3200-13240 3.41 3.62 A A Inverter Rotary 58 58 2 3 MHM73 Heating: - Room air temperature 20 °C - External air temperature 7 °C D.B.; 6 °C W.B. - Maximum speed OUTDOOR UNITS MHM84 with adaptors 1 9,52 (3/8") ➔ 12,7 (1/2") 9,52 (3/8") ➔ 12,7 (1/2") 9,52 (3/8") ➔ 12,7 (1/2") with adaptors 2 9,52 (3/8") ➔ 12,7 (1/2") 9,52 (3/8") ➔ 12,7 (1/2") with adaptors 3 with adaptors 4 with adaptors 5 with adaptors 6 with adaptors 7 with adaptors 8 with adaptors 9 with adaptors 10 Models Liquid refrigerant connections / Pipes Gas refrigerant connections / Pipes 84 8000 230V ~ 50Hz The performance refers to the following conditions: Sound pressure measures in a semianechoic chamber at 1m from the front Cooling: - Room air temperature 27 °C D.B.; 19 °C W.B. - External air temperature 35 °C - Maximum speed MHM72 73 7100 MHM20W 6,35 (1/4") 9,52 (3/8") INDOOR UNITS - WALL MHM25W MHM35W 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") INDOOR UNITS - DUCT MHM25D MHM35D 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") INDOOR UNITS - CASSETTE SMALL MHM35CS 6,35 (1/4") 9,52 (3/8") INDOOR UNITS - CASSETTE MHM35C 6,35 (1/4") 9,52 (3/8") INDOOR UNITS - FLOOR CEILING MHM25F MHM35F 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") INDOOR UNITS - CONSOLE MHM25FS MHM35FS 6,35 (1/4") 6,35 (1/4") 9,52 (3/8") 9,52 (3/8") MHM104 MHM125 9,52 (3/8") ➔ 6,35 (1/4") 9,52 (3/8") ➔ 6,35 (1/4") 9,52 (3/8") ➔ 12,7 (1/2") 9,52 (3/8") ➔ 12,7 (1/2") 9,52 (3/8") ➔ 12,7 (1/2") 12,7 (1/2") ➔ 9,52 (3/8") 12,7 (1/2") ➔ 9,52 (3/8") 12,7 (1/2") ➔ 9,52 (3/8") 12,7 (1/2") ➔ 9,52 (3/8") 12,7 (1/2") ➔ 9,52 (3/8") 12,7 (1/2") ➔ 15,9 (5/8") 12,7 (1/2") ➔ 9,52 (3/8") 15,9 (5/8") ➔ 9,52 (3/8") 12,7 (1/2") ➔ 15,9 (5/8") 12,7 (1/2") ➔ 15,9 (5/8") 12,7 (1/2") ➔ 15,9 (5/8") 15,9 (5/8") ➔ 9,52 (3/8") MHM50W 6,35 (1/4") 12,7 (1/2") MHM50D 6,35 (1/4") 12,7 (1/2") MHM60D 9,52 (3/8") 15,9 (5/8") MHM70D 9,52 (3/8") 15,9 (5/8") MHM50CS 6,35 (1/4") 12,7 (1/2") MHM50C 6,35 (1/4") 12,7 (1/2") MHM70C 9,52 (3/8") 15,9 (5/8") MHM50F 6,35 (1/4") 12,7 (1/2") MHM70F 9,52 (3/8") 15,9 (5/8") MHM50FS 6,35 (1/4") 12,7 (1/2") Dimensions (mm) MHM_W B A C MHM C MHMGL40 MHM_CS MHMGL40S MHM_D MHM_F MHM_FS MHM20W MHM25W MHM35W MHM50W A (mm) 794 794 848 945 B (mm) 265 265 274 298 C (mm) 182 182 189 208 Weight (kg) 9 9 10 13 MHM35CS* MHM50CS* MHMGL40S 600 600 650 600 600 650 230 230 50 20 20 5 MHM35C** MHM50C** MHM70C** MHMGL40 840 840 840 950 840 840 840 950 190 190 240 50 25 25 30 5 MHM25D MHM35D MHM50D MHM60D MHM70D 782 782 982 1182 1182 635 635 635 635 635 200 200 200 200 200 22 24 25 29 29 MHM25F MHM35F MHM50F MHM70F 1220 1220 1220 1220 700 700 700 700 225 225 225 225 40 40 40 45 MHM25FS MHM35FS MHM50FS 700 700 700 600 600 600 215 215 215 15 15 15 MHM42 MHM52 MHM72 MHM73 MHM84 MHM104 MHM125 903 903 963 963 963 950 1015 378 378 396 396 396 412 440 596 596 700 700 700 840 1103 43 43 59 59 60 73 102 * coupling with the MHMGL40S accessory is mandatory (mm 650x650) **coupling with the MHMGL40 accessory is mandatory (mm 950x950) The technical data given on this documentation is not binding. Aermec S.p.A. reserves the right to apply at any time all the modifications deemed necessary for improving the product. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel. 0442633111 - Telefax 044293730 www.aermec.com Cod.: SMHMUY.00P / 1202 MHM
© Copyright 2026 Paperzz