™ Highlights WiT-3300 LOD System • Detects live objects at the source resonator perimeter and automatically shuts down the system when an object crosses the perimeter boundary zone during energy transfer • Integrates with the WiTricity WiT-3300 EV Charging System for safe, effective wireless charging of EVs and HEVs • LOD software implemented on embedded processor – does not require an external computer1 • Design documentation package includes electrical and mechanical design data and LOD software LOD Evaluation System • LOD 1.0 frame sensor2 • LOD calibration and monitoring software Design Documentation • LOD 1.0 PCB layout and circuit schematics • SolidWorks CAD files • Bill of materials including approved vendor lists • System operation and instruction manual • LOD 1.0 software object code (embedded firmware for LOD unit embedded processor) • WiTricity IP licensees receive LOD 1.0 source code, including signal processing, calibration, and real-time detection and classification algorithms Overview The WiTricity WiT-3300 Live Object Detection (LOD) sensor helps ensure the safe operation of WiT-3300 electric vehicle (EV) charging systems. Built as a perimeter sensor for the WiT-3300 source resonator3, the device senses the presence of humans or animals that intrude into a detection zone around the source, and enables the automatic shutdown of the charging system. LOD Technology The patented WiT-3300 LOD sensor is implemented as a frame that fits around a WiT-3300 source resonator enclosure. It utilizes capacitive sensing technology and local signal processing and control for real time live object proximity detection. By utilizing a proprietary shielded sensor array that is unaffected by the energy transfer system, WiTricity’s LOD system can detect live objects as small as a human hand, foot or small animal as it intrudes into the detection zone. Once an object is detected a signal is output to shut down the power source. Note that the LOD sensor can be actively monitoring the detection zone while the system is charging the vehicle, and when the charging system is not operating. Optimized for detection of live objects such as a human hand or foot, WiTricity’s LOD sensor will be unaffected by dust or dirt that may accumulate on the sensor and will minimize false alarms due to detection of other low dielectric, non-metallic items made of wood, plastic, or paper. Furthermore, the proprietary LOD detection and signal processing algorithms compensate for drift in ambient humidity and temperature that may confuse less sophisticated proximity detectors that utilize capacitive sensing. ! ! requires FOD hardware R1.2 or higher for interface to CAN Bus. requires FOD enabled source resonator - R2.3 3 resonator revision R2.3 1 2 LOD System Specifications Detection Volume: From LOD sensor top surface to 15cm above. Dependent on object type, size and shape. Detection Latency: < 2 seconds Detection Capability: Live objects of size equal to or larger than human hand directly above sensor frame. Dependent on spatial position relative to LOD sensor frame. (Note: detectability will be improved close to LOD sensor frame top surface and will decrease with distance away) LOD Interface Software The LOD sensor is controlled either through the ASP menu of the WiT-3300 or via a dedicated LOD interface application. The WiT-3300 ASP menu controls LOD through the CANbus interface and will allow basic control functionality: enable / disable, system shutdown, and sensitivity setting. Alternatively, LOD can be controlled directly via USB and the interface application which will allow for real time signal information in addition to all ASP functionality. This separate interface application provides a real time numerical output level of the LOD signal allowing users to establish system response baselines for various objects and intelligently set detection threshold settings. Data & Power Interface To FOD board: direct ribbon cable connection To R3 electronics: CAN Bus 2.0B (via FOD board R1.2) LOD External Dimensions: 63cm x 63 cm x 5 cm Left: LOD Interface Application Right: Integrated R3LOD/FOD control Power Electronics Compatibility LOD/FOD Laptop Control: R2 or higher Integrated FOD Control: R3 or higher Contact Us WiTricity Corporation 149 Grove Street Watertown, MA 02472 www.witricity.com 617.926.2700 phone 617.926.2745 fax To discuss possible applications: [email protected] ! Copyright 2014 WiTricity Corporation. All rights reserved. Implementing LOD WiTricity offers a LOD Evaluation Kit, which includes a LOD sensor frame designed to fit around the perimeter of a 50cm x 50cm FOD enabled source resonator (resonator R2.3). A FOD enabled source resonator is necessary for LOD implementation as it provides the communication path to the R3 electronics or PC. Also available is a LOD Design Documentation Package, which includes the electrical and mechanical design data needed to reproduce the LOD 1.0 hardware and object code software. In addition, source code to the signal processing, calibration, and real-time detection and classification software is available to those organizations that execute a WiTricity technology license.
© Copyright 2024 Paperzz