CEMTREX, INC. MODCON SYSTEMS LTD NIR Systems July 2010 NIR Spectroscopy Principle Beer–Lambert law Logarithmic dependence between the transmission T, of light through a substance and the product of the absorption A coefficient of the substance, α, and the distance the light travels through the material (i.e. the path length), ℓ. NIR Analyzers Advantage • Low Cost of Ownership • Optimized production processes by real time monitoring • Improved process knowledge • Expensive and time consuming laboratory analyses are no longer necessary • Improved quality assurance • Minimal maintenance required • Easy to calibrate - automatic calibration model updating • Powerful communication system Beacon 3000 NIR Analyzer Advantage • Connection to up to 8 process stream sensors • No longer location-specific can be situated up to 2 miles (3,2km) away from main analyzer • Use of standard telecommunication fiber optics • Contains no moving parts • No electricity required Block Diagram DCS Analyzer Processor Controller Fiber Optic Cable Field Units installed throughout the plant Field Unit Operation Conditions • • • • Haze free Max. Pressure Flow rate Temperature Field Unit - 550 psi (40 bar) - 1 l/min to 3 l/min - Above Cloud point to +160°C (300°F) Sample Cell Probe No Effect of Fiber Length 1.2 0.8 20 feet fiber 2 miles fiber 0.4 0.0 -0.4 -0.8 800 840 880 920 Wavelength, nm 960 1000 From Spectral Information to Electronic Data Light Source Field Unit Reports Detector Module Measured Spectra Measured Spectra 3.00 Properties Calculation 2.00 Processor 1.00 0.00 -1.00 -2.00 800 850 900 950 1000 Online Sample Collection and Model Building Control Room Analyzer Field Process Plant Lab Service Center Save Spectrum Save Spectrum Model Principles of Chemo-metrics Calibration Phase Reference Spectra Reference Measurements mix# 0.25 0.2 0.15 0.25 0.1 0.2 0.05 0.15 0 0.1 0.2 -0.05 810 0.05 0.15 860 0.1 0.2 -0.1 0 -0.05 810 0.05 0.15 860 -0.15 0.25 0.25 910 -0.1 0 0.1 -0.15 -0.05 810 0.05 -0.1 0 -0.15 -0.05 960 1010 910 860 810 960 910 860 + 1060 1010 960 910 1060 1010 960 1060 1010 1060 HCl 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 0 1.178964 0.790395 1.090314 1.06258 0.852719 0.99566 0.873404 0.988138 0.849897 1.000474 1.102819 1.135659 0.799425 0.950737 Calibration Model HF 0 0.39912 0.442637 0.496751 0.543865 0.593886 0.634382 0.669103 0.721126 0.778561 0.81478 0.853354 0.893109 1.009638 0.958367 -0.1 -0.15 Measurement Phase Unknown Spectra Real Time Results Calibration Model 0.25 0.2 + 0.15 0.1 0.05 A1(t) A2(t) tote changeover new lot changeover 0.04 0.03 0.02 0.01 0.05 0 0 -0.05 -0.01 -0.1 -0.02 -0.15 -0.03 -0.04 -0.2 -0.05 -0.25 Wed 07/7 Fri 09/7 Sun 11/7 Tue 13/7 Thu 15/7 Sat 17/7 Mon 19/7 Wed 21/7 Fri 23/7 Sun 25/7 Tue 27/7 Thu 29/7 Sat 31/7 Mon 02/8 Wed 04/8 Fri 06/8 Typical Gasoline Spectra 800 850 900 Wavelength, nm 950 1000 X and Y Data Single Spectrum (x1 , x2 ... xn ) x11 x12 2 2 x1 x 2 p p x1 x 2 800 848 884 908 944 Wavelength, nm Spectra x11 x12 2 x1 x 22 p p x1 x 2 X data x1n 2 xn p xn y 11 y 12 y 1p Y data Property x1n x n2 x pn 992 MON of Gasoline - Universal Model 96 93 NIR 90 87 84 81 78 78 81 84 87 Reference 90 93 96 Note on Lab Results Good Model Good Lab data and on Time Bad Lab data Good NIR Results GIGO Bad Model Bad NIR Results Statistic Nomenclature Root Mean Square Error of Prediction n 2 ( ŷ y ) i i RMSEP i 1 n ŷ - laboratory reference y - calculated value Standard Error of Prediction n 2 ( ŷ y Bias) i i SEP i =1 n -1 Average Difference between ŷ and n Bias i 1 ( yˆ i yi ) n y in Prediction Set Modcon Solution Free-tune Software This software program is composed of two sequential blocks: I. PLS regression is used to build a localized sensitive model (LSM) based on just a small number of samples. One of the characteristics of this model is its sensitivity to short term (hours) process variations. Since it is localized, the model can be quickly built and validated. This procedure takes up to one week and can be performed prior to startup. II. A proprietary software program processes the model, together with the specified plant data, to accurately quantify the properties. This part deals with predicting the long-term product variability. Monitored Variable NIR Spectra PreProcessing Laboratory Data LSM Advanced Processing Validity Flag Model Updating Model updating during the crude switching Fusion Solutions Stream 1 Stream 2 Stream 3 Distributed Control System NIR NIR Sample System Discrete Analyzer Modbus NIR Fiber optic cable Response time: 5-10 min Accuracy: according to ASTM Availability: above 98% (full-redundant system) NIR Analyzer with Freetune* software Thank You for Your Attention
© Copyright 2026 Paperzz