Strategic Energy Management For Resilience The Good, Bad and Ugly of Organizations for Energy Efficiency Norman Lee FIChemE 6 October 2015 1 Actsys Overview About Us Services Singapore Based Company Incorporated 2001 Operating regionally (Malaysia, Indonesia, Thailand, India) Core expertise Thermodynamic Performance Analysis Process Simulation / Pinch Analysis Utilities System Optimization Basic Engineering Design Operations and Maintenance experience Domain knowledge Power Plants, Refineries, Petrochemicals Accredited as Energy Service Company by Singapore National Environmental Agency 2 Actsys Overview About Us Services Power Plant Thermodynamic Performance Analysis Energy Auditing for Improvement Opportunities Measurement & Verification Energy Management System Online Dashboards ISO50001 Gap Analysis Process Studies and Front End Design Training Plant Operating Principles Energy Auditing / Performance Monitoring 3 Actsys Major Customers 4 Agenda Bad Good Maintenance X Operations X Performance Monitoring X X Retrofits X X Energy Dashboards Energy Management X X X 5 Bad Maintenance 6 Bad Maintenance 7 Bad Maintenance 8 Bad Maintenance 9 Bad Maintenance 10 Bad Maintenance Bare pipe heat loss : 2” (0.05m) diameter D, 2m length L Steam temperature Ts 180 degC Ambient temperature Ta 30 degC Heat Transfer Coeff Hc 25 W/m2C (normal light wind) Heat Loss = (πD2/4) * L * (Ts – Ta) * Hc = 15 W Equivalent to 15 Tons Extra Steam Consumption per Annum or approximately loss of $900 / Annum 11 Good Maintenance Regular condition monitoring of equipment to ensure timely corrective maintenance 12 Bad Maintenance 1” steam trap fixed incorrectly in reverse will allow 0.2 Tons/day steam loss worth $4380 per annum 13 ISO50001 Keywords Energy Training Energy Measurement Equipment Performance Energy Audits 14 Bad Operations Target 2% Every 1% excess O2 will result in 0.2% extra fuel consumption 15 ISO50001 Keywords Energy Targets Energy Deviation Monitoring Energy Training Continuous Improvement 16 Bad Performance Monitoring Crude to Furnace E21254 Crude from Storage To Storage Tank E21253 E21273 P21252 Max Target Furnace Crude Distillation Column C21251 17 Bad Performance Monitoring 5500 mmBtu/A lost Energy Recovery $100,000/A 18 Good Performance Monitoring Condensate Extraction Pump Bypass Valve Preheated Water To Deaerator V-1 E-3 Flue Gas Inlet Feed water Preheater Passing Valve Flue Gas to Stack 19 0.90 31-Dec-05 17-Dec-05 3-Dec-05 19-Nov-05 5-Nov-05 22-Oct-05 8-Oct-05 24-Sep-05 10-Sep-05 27-Aug-05 13-Aug-05 30-Jul-05 16-Jul-05 2-Jul-05 18-Jun-05 4-Jun-05 21-May-05 7-May-05 23-Apr-05 9-Apr-05 1.10 26-Mar-05 12-Mar-05 26-Feb-05 12-Feb-05 29-Jan-05 15-Jan-05 1-Jan-05 Good Performance Monitoring Stack /temp Vsand Feedwater Temperature (Actual) (New Clean Preheater Performance) Stack T Feedwater Preheater T 1.05 1.00 0.95 Valve Repaired 20 ISO50001 Keywords Energy Performance Indicators Equipment Performance Energy Training Energy Reporting 21 Bad Retrofits VSD Installed for Condenser Fans 22 Bad Retrofits Operation of Fan VSD 23 Bad Retrofits Power Generation Loss due to Lower Fan Speed by VSD 24 Good Retrofit 137 HS Legend: Preflash OVHD Kero Prod Kero PA Diesel Diesel PA LSWR 105 142 150 108 139 Desalter 110 251 deg C 140 Pre-flasher 50 kbbl/d 141 136 128 112 115 113 25 Good Retrofit 67 deg C E137B HS Legend: Preflash OVHD Kero Prod Kero PA Diesel Diesel PA LSWR 93 deg C E105C 131 deg C 98.5 deg C E139B Desalter E142C 251 deg C E140B E136B PROPRIETARY INFORMATION 229 deg C Pre-flasher C-116 50 kbbl/d 39 deg C 201 deg C 225 deg C 112 A/B 150 deg C 108 A/B E141B 208 deg C 26 Good Retrofit 260 degC Start-up Furnace Inlet Temperature 255 250 245 240 Last cycle before project commissioning 235 230 225 220 27 ISO50001 Keywords Energy Audits Energy Training Energy Measurement Energy Performance Indicators Continuous Improvement 28 Good Energy Dashboards 29 Good Energy Dashboards 30 Good Energy Management • Design • Historical best performance • Simulation equations • Performance Test Runs Current Plant Operation Actual Energy Operating Parameter Target Energy Operating Parameter • Changed energy index deviations • Improved plant performance Energy Index Deviation (EID) Plant Adjustments and improvements Operator Action / Maintenance Planning Excess Utility Consumption (Steam / FG / Electricity) • Changing set points • Adjusting control parameters • Plan for corrective maintenance 31 Good Energy Management MTBE Energy Specific Consumption & Energy Cost (2008-2012) 8,000,000.00 Savings 14.00 7,000,000.00 RM 2 Million/month 12.00 Energy Cost 10.00 5,000,000.00 8.00 4,000,000.00 ESC, mmBTU/MT Energy Cost, RM 6,000,000.00 MTBE Energy Specific Consumption 6.00 3,000,000.00 4.00 2,000,000.00 2.00 1,000,000.00 Nov-07 Jun-08 Dec-08 Jul-09 Jan-10 Aug-10 Feb-11 Sep-11 Apr-12 0.00 Oct-12 May-13 32 Bad Energy Management 5.753 25% thermal Efficiency loss 4.2131 Exhaust Dump MW Steam Energy MW 0.07 P T 536.74 12.40 P T 193.05 36142W H 573.08 5443.1W H 2786.5 13.00 P T 103.00 5443.1W H 432.69 S7 16.479 S14 Fuel Energy MW S9 S10 S8 S13 S2 S5 S6 SP1 0.07 P T 217.87 S4 31.000 DB1 Ambient DegC S16 EVAP1 ECON1 36142W H 215.06 S1 S17 GT D1 DU CT1 4.6552 GT Power MW 33 ISO50001 Keywords Energy Manager Equipment Planning Energy Measurement Energy Performance Indicators 34 Characteristics of Good and Bad Organizations for Energy Efficiency ISO50001 EnMS Gap Analysis Energy Manager Continuous Improvement Energy Plannning 50% Energy Training Energy Improvement activities… Energy Measurement 40% 30% 60% 10% 30% 30% Energy Reporting 10% 10% 50% Equipment Performance 30% 70% Energy Targets Energy Performance Indicators Energy Audits Energy Deviation Monitoring 35 36
© Copyright 2026 Paperzz