40 WATTS OUTPUT POWER 2:1 WIDE INPUT VOLTAGE RANGE INTERNATIONAL SAFETY APPROVAL PENDING SIX-SIDED CONTINUOUS SHIELD HIGH EFFICIENCY UP TO 90% STANDARD 3” X 2.6” X 0.4” PACKAGE FIXED SWITCHING FREQUENCY The FDC40 offer 40 Watts of output power from a 3 x 2.6 x 0.4 inch package. The FDC40 series have 2:1 wide input voltage of 9-18, 18-36 and 36-75VDC. The FDC40 features 1600VDC of isolation, short-circuit and over-voltage protection, as well as six sided shielding. Designed meets the safety of EN60950 and UL1950. All models are particularly suited to telecommunications, industrial, mobile telecom and test equipment applications. T E C H N I C A L S P E C I F I C AT I O N All specifications are typical at nominal input, full load and 25ºC otherwise noted OUTPUT SPECIFICATIONS GENERAL SPECIFICATIONS Output Power 40 Watts max Voltage accuracy Full load and nominal Vin Single & Dual Triple 3.3V/5V Auxiliary Voltage adjustability Minimum load (Note1) FDC40-XXD3305 3.3Voutput Others 20% min 10% of full load ± 0.5% (± 1%) ± 2% ± 5% LL to HL at FL single (dual) Triple 3.3V / 5V Auxiliary Line regulation Load regulation 10% to 100% FL Single Dual Triple 3.3V/5V Auxiliary Dual Triple 3.3V / 5V Auxiliary 20MHz bandwidth Cross regulation (Note2) Ripple and noise Temperature coefficient ± 0.5% ± 1% ± 2% ± 5% ± 1% ± 1% ± 5% 1% pk-pk of Vout 3.3V output 5V output 12V output 15V output Short circuit protection 500uS 3.9V 6.2V 15V 18V Hiccup, automatics recovery INPUT SPECIFICATIONS Input voltage range 9 – 18VDC 18 – 36VDC 36 – 75VDC 12V input 24V input 48V input Nominal Vin and constant resistor load Remote ON/OFF (Note4) Remote off input current 1600VDC Isolation resistance 10 ohms 500pF 9 Isolation capacitance Switching frequency 185KHz Approvals and standard UL1950, EN60950 Case material Nickel-coated copper Base material Non-conducted black FR4 Potting material Epoxy (UL94-Vo) Dimensions 3.00 x 2.60 x 0.40 Inches (70.2 x 66.0 x 10.2 mm) 125g (4.4 oz) Weight MTBF MIL-HDBK-217F, TA=25ºC full load DC-DC ON DC-DC OFF 5 2.294 x 10 hours ENVIRONMENTAL SPECIFICATIONS -40ºC to +85ºC (With derating) Operation temperature range +100ºC Maximum case temperature -55ºC to +105ºC Storage temperature range Thermal impedance Nature convection Thermal shock Vibration 5.7ºC/watt Mil-STD-810D 10~55Hz, 2G, 3minitues period, 30minitues along X,Y and Z 5% to 95% RH EMC CHARACTERISTICS Conducted emissions EN55022 Level A Radiated emissions EN55022 Level A 36VDC 50VDC 100VDC Conducted immunity EN61000-4-6 Perf. Criteria2 Radiated immunity EN61000-4-3 Perf. Criteria2 40mAp-p Surge EN61000-4-5 Perf. Criteria2 Fast transient EN61000-4-4 Perf. Criteria2 ESD EN61000-4-2 Perf. Criteria2 Pi type Input reflected ripple (Note3) Start up time See table Isolation Voltage Relative humidity 12V nominal input 24V nominal input 48V nominal input Input filter Input surge voltage 100mS max Efficiency ± 0.02% / ºC, max Transient response recovery time 25% load step change Over voltage Zener diode clamp ± 2% ± 2% ± 5% ± 10% 25mS typ Open or 3.5V < Vr < 12V Short or 0V < Vr < 1.2V 30mA Output Voltage Output Current FDC40-12S33 9 – 18 VDC 3.3VDC 10A 3.53A 83 25800uF FDC40-12S05 9 – 18 VDC 5VDC 8A 4.17A 84 13600uF FDC40-12S12 9 – 18 VDC 12VDC 3.4A 4.10A 87 2400uF FDC40-12S15 9 – 18 VDC 15VDC 2.7A 4.10A 87 1550uF FDC40-12D05 9 – 18 VDC ±5VDC +7A / -1A 4.33A 81 12000 / 1700uF FDC40-12D12 9 – 18 VDC ±12VDC ±1.8A 4.55A 83 ±1200uF FDC40-12D15 9 – 18 VDC ±15VDC ±1.4A 4.43A 83 ±750uF FDC40-12D3305 9 – 18 VDC 3.3 / 5VDC 4A / 4A 3.73A 78 10300 / 6800uF FDC40-12T0512 9 – 18 VDC 5 / ±12VDC 4A / ±850mA 4.49A 79 6800/±590uF FDC40-12T0515 9 – 18 VDC 5 / ±15VDC 4A / ±680mA 4.43A 80 6800/±380uF FDC40-24S33 18 – 36 VDC 3.3VDC 10A 1.72A 84 25800uF FDC40-24S05 18 – 36 VDC 5VDC 8A 2.01A 87 13600uF FDC40-24S12 18 – 36 VDC 12VDC 3.4A 1.98A 90 2400uF FDC40-24S15 18 – 36 VDC 15VDC 2.7A 2.00A 88 1550uF FDC40-24D05 18 – 36 VDC ±5VDC +7A / -1A 2.13A 82 12000 / 1700uF ±1200uF Input (5) Current 18 – 36 VDC ±12VDC ±1.8A 2.17A 87 18 – 36 VDC ±15VDC ±1.4A 2.14A 86 ±750uF FDC40-24D3305 18 – 36 VDC 3.3 / 5VDC 4A / 4A 1.84A 79 10300 / 6800uF FDC40-24T0512 18 – 36 VDC 5 / ±12VDC 4A / ±850mA 2.18A 81 6800/±590uF FDC40-24T0515 18 – 36 VDC 5 / ±15VDC 4A / ±680mA 2.16A 82 6800/±380uF FDC40-48S33 36 – 75 VDC 3.3VDC 10A 0.85A 85 25800uF FDC40-48S05 36 – 75 VDC 5VDC 8A 0.98A 89 13600uF FDC40-48S12 36 – 75 VDC 12VDC 3.4A 1.00A 89 2400uF FDC40-48S15 36 – 75 VDC 15VDC 2.7A 1.00A 88 1550uF FDC40-48D05 36 – 75 VDC ±5VDC +7A / -1A 1.06A 84 12000 / 1700uF FDC40-48D12 36 – 75 VDC ±12VDC ±1.8A 1.10A 86 ±1200uF FDC40-48D15 36 – 75 VDC ±15VDC ±1.4A 1.10A 86 ±750uF FDC40-48D3305 36 – 75 VDC 3.3 / 5VDC 4A / 4A 0.91A 80 10300 / 6800uF FDC40-48T0512 36 – 75 VDC 5 / ±12VDC 4A / ±850mA 1.06A 83 6800/±590uF FDC40-48T0515 36 – 75 VDC 5 / ±15VDC 4A / ±680mA 1.06A 83 6800/±380uF FDC40-48S05 Efficiency VS Input Voltage EFFICIENCY (%) The FDC40 series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. Cross regulation: Dual output—Asymmetrical load 25% to 100% full load Triple output – 3.3V / 5V 100% load and one of auxiliary 100% load, other auxiliary load change from 25% to 100% load Simulated source impedance of 12uH. 12uH inductor in series with +Vin. The ON-OFF control pin voltage is reference to negative input. Maximum value at nominal input voltage and full load Typical value at nominal input voltage and full load 90 89 88 87 86 85 84 83 82 81 80 36 40 45 50 55 60 65 70 75 6 7 8 INPUT VOLTAGE (V) FDC40-48S05 Derating Curve FDC40-48S05 Efficiency VS Output load EFFICIENCY (%) 3. 4. 5. 6. Capacitor Load max. FDC40-24D15 OUTPUT POWER (%) 2. Eff (%) FDC40-24D12 Note 1. (6) Input Range Model Number 100 75 50 Nature convection 25 0 -40 -25 -10 0 50 60 70 AMBIENT TEMPERATURE (ºC) 80 90 100 90 89 88 86 84 82 80 70 60 50 45 0.5 1 2 3 4 OUTPUT LOAD (A) 5 0.40 0.40 0.60 (15.2) (10.2) (10.2) 2 4 3 Single Dual Triple 3.3V/5V 7 7 9 6 6 8 10 8 5 5 8 5 TRIM UP TRIM DOWN 2.50 (63.5) Bottom View 3.00 (76.2) EXTERNAL OUTPUT TRIMMING 0.40 (10.2) DIA. 0.04 (1.0) 1 0.70 (17.8) 0.30 (7.6) 2.60 (66.0) PIN CONNECTION 5 6 7 8 0.50 (12.7) 0.30 (7.6) 9 10 0.40 0.40 0.40 (10.2) (10.2) (10.2) 0.32 (8.0) 0.30 (7.6) 1. All dimensions in Inches (mm) 2. Pin pitch tolerance ±0.014(0.35) PIN SINGLE DUAL TRIPLE 3.3V / 5V 1 2 3 4 5 6 7 8 9 10 CTRL + INPUT - INPUT SYNC TRIM DOWN TRIM TRIM UP + OUTPUT - OUTPUT NO PIN CTRL + INPUT - INPUT SYNC + OUTPUT CTRL + INPUT - INPUT SYNC + AUX CTRL + INPUT - INPUT SYNC +3.3V COMMON - OUTPUT TRIM NC NC COMMON (AUX) - AUX + OUTPUT - OUTPUT TRIM COMMON + 5V TRIM NC NC Converter 1 2 + Vin 4 3 - Vin + Sync - Application of synchronization 1. The unit is capable of external synchronization from an independent time base with a switching rate between 200kHz and 215kHz 2. The amplitude of the synchronizing pulse train is TTL compatible 3. The duty cycle of the CLK should be 20% high and 80% low 4. Synchronization is referenced to negative input (-Vin) Converter 2 2 4 3 + Sync ON/OFF Control application - Converter + Vin CLK 1 CLK Signal 80% - Vin ON/OFF Control 20% 2 3 + CTRL -
© Copyright 2026 Paperzz