40 WATTS OUTPUT POWER SIX-SIDED CONTINUOUS SHIELD

40 WATTS OUTPUT POWER
2:1 WIDE INPUT VOLTAGE RANGE
INTERNATIONAL SAFETY APPROVAL PENDING
SIX-SIDED CONTINUOUS SHIELD
HIGH EFFICIENCY UP TO 90%
STANDARD 3” X 2.6” X 0.4” PACKAGE
FIXED SWITCHING FREQUENCY
The FDC40 offer 40 Watts of output power from a 3 x 2.6 x 0.4 inch package. The FDC40
series have 2:1 wide input voltage of 9-18, 18-36 and 36-75VDC. The FDC40 features
1600VDC of isolation, short-circuit and over-voltage protection, as well as six sided
shielding. Designed meets the safety of EN60950 and UL1950. All models are particularly
suited to telecommunications, industrial, mobile telecom and test equipment applications.
T E C H N I C A L S P E C I F I C AT I O N
All specifications are typical at nominal input, full load and 25ºC otherwise noted
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Output Power
40 Watts max
Voltage accuracy
Full load and nominal Vin
Single & Dual
Triple 3.3V/5V
Auxiliary
Voltage adjustability
Minimum load (Note1) FDC40-XXD3305 3.3Voutput
Others
20% min
10% of full load
± 0.5% (± 1%)
± 2%
± 5%
LL to HL at FL single (dual)
Triple 3.3V / 5V
Auxiliary
Line regulation
Load regulation
10% to 100% FL Single
Dual
Triple 3.3V/5V
Auxiliary
Dual
Triple 3.3V / 5V
Auxiliary
20MHz bandwidth
Cross regulation
(Note2)
Ripple and noise
Temperature coefficient
± 0.5%
± 1%
± 2%
± 5%
± 1%
± 1%
± 5%
1% pk-pk of Vout
3.3V output
5V output
12V output
15V output
Short circuit protection
500uS
3.9V
6.2V
15V
18V
Hiccup, automatics recovery
INPUT SPECIFICATIONS
Input voltage range
9 – 18VDC
18 – 36VDC
36 – 75VDC
12V input
24V input
48V input
Nominal Vin and constant resistor load
Remote ON/OFF
(Note4)
Remote off input current
1600VDC
Isolation resistance
10 ohms
500pF
9
Isolation capacitance
Switching frequency
185KHz
Approvals and standard
UL1950, EN60950
Case material
Nickel-coated copper
Base material
Non-conducted black FR4
Potting material
Epoxy (UL94-Vo)
Dimensions
3.00 x 2.60 x 0.40 Inches
(70.2 x 66.0 x 10.2 mm)
125g (4.4 oz)
Weight
MTBF
MIL-HDBK-217F, TA=25ºC full load
DC-DC ON
DC-DC OFF
5
2.294 x 10 hours
ENVIRONMENTAL SPECIFICATIONS
-40ºC to +85ºC
(With derating)
Operation temperature range
+100ºC
Maximum case temperature
-55ºC to +105ºC
Storage temperature range
Thermal impedance
Nature convection
Thermal shock
Vibration
5.7ºC/watt
Mil-STD-810D
10~55Hz, 2G, 3minitues period, 30minitues along X,Y and Z
5% to 95% RH
EMC CHARACTERISTICS
Conducted emissions
EN55022
Level A
Radiated emissions
EN55022
Level A
36VDC
50VDC
100VDC
Conducted immunity
EN61000-4-6
Perf. Criteria2
Radiated immunity
EN61000-4-3
Perf. Criteria2
40mAp-p
Surge
EN61000-4-5
Perf. Criteria2
Fast transient
EN61000-4-4
Perf. Criteria2
ESD
EN61000-4-2
Perf. Criteria2
Pi type
Input reflected ripple (Note3)
Start up time
See table
Isolation Voltage
Relative humidity
12V nominal input
24V nominal input
48V nominal input
Input filter
Input surge voltage
100mS max
Efficiency
± 0.02% / ºC, max
Transient response recovery time 25% load step change
Over voltage
Zener diode clamp
± 2%
± 2%
± 5%
± 10%
25mS typ
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
30mA
Output
Voltage
Output
Current
FDC40-12S33
9 – 18 VDC
3.3VDC
10A
3.53A
83
25800uF
FDC40-12S05
9 – 18 VDC
5VDC
8A
4.17A
84
13600uF
FDC40-12S12
9 – 18 VDC
12VDC
3.4A
4.10A
87
2400uF
FDC40-12S15
9 – 18 VDC
15VDC
2.7A
4.10A
87
1550uF
FDC40-12D05
9 – 18 VDC
±5VDC
+7A / -1A
4.33A
81
12000 / 1700uF
FDC40-12D12
9 – 18 VDC
±12VDC
±1.8A
4.55A
83
±1200uF
FDC40-12D15
9 – 18 VDC
±15VDC
±1.4A
4.43A
83
±750uF
FDC40-12D3305
9 – 18 VDC
3.3 / 5VDC
4A / 4A
3.73A
78
10300 / 6800uF
FDC40-12T0512
9 – 18 VDC
5 / ±12VDC
4A / ±850mA
4.49A
79
6800/±590uF
FDC40-12T0515
9 – 18 VDC
5 / ±15VDC
4A / ±680mA
4.43A
80
6800/±380uF
FDC40-24S33
18 – 36 VDC
3.3VDC
10A
1.72A
84
25800uF
FDC40-24S05
18 – 36 VDC
5VDC
8A
2.01A
87
13600uF
FDC40-24S12
18 – 36 VDC
12VDC
3.4A
1.98A
90
2400uF
FDC40-24S15
18 – 36 VDC
15VDC
2.7A
2.00A
88
1550uF
FDC40-24D05
18 – 36 VDC
±5VDC
+7A / -1A
2.13A
82
12000 / 1700uF
±1200uF
Input
(5)
Current
18 – 36 VDC
±12VDC
±1.8A
2.17A
87
18 – 36 VDC
±15VDC
±1.4A
2.14A
86
±750uF
FDC40-24D3305
18 – 36 VDC
3.3 / 5VDC
4A / 4A
1.84A
79
10300 / 6800uF
FDC40-24T0512
18 – 36 VDC
5 / ±12VDC
4A / ±850mA
2.18A
81
6800/±590uF
FDC40-24T0515
18 – 36 VDC
5 / ±15VDC
4A / ±680mA
2.16A
82
6800/±380uF
FDC40-48S33
36 – 75 VDC
3.3VDC
10A
0.85A
85
25800uF
FDC40-48S05
36 – 75 VDC
5VDC
8A
0.98A
89
13600uF
FDC40-48S12
36 – 75 VDC
12VDC
3.4A
1.00A
89
2400uF
FDC40-48S15
36 – 75 VDC
15VDC
2.7A
1.00A
88
1550uF
FDC40-48D05
36 – 75 VDC
±5VDC
+7A / -1A
1.06A
84
12000 / 1700uF
FDC40-48D12
36 – 75 VDC
±12VDC
±1.8A
1.10A
86
±1200uF
FDC40-48D15
36 – 75 VDC
±15VDC
±1.4A
1.10A
86
±750uF
FDC40-48D3305
36 – 75 VDC
3.3 / 5VDC
4A / 4A
0.91A
80
10300 / 6800uF
FDC40-48T0512
36 – 75 VDC
5 / ±12VDC
4A / ±850mA
1.06A
83
6800/±590uF
FDC40-48T0515
36 – 75 VDC
5 / ±15VDC
4A / ±680mA
1.06A
83
6800/±380uF
FDC40-48S05
Efficiency VS Input Voltage
EFFICIENCY (%)
The FDC40 series required a minimum 10% loading on the output to maintain
specified regulation. Operation under no-load condition will not damage these
devices, however they may not meet all listed specification.
Cross regulation:
Dual output—Asymmetrical load 25% to 100% full load
Triple output – 3.3V / 5V 100% load and one of auxiliary 100% load, other
auxiliary load change from 25% to 100% load
Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
The ON-OFF control pin voltage is reference to negative input.
Maximum value at nominal input voltage and full load
Typical value at nominal input voltage and full load
90
89
88
87
86
85
84
83
82
81
80
36
40
45
50
55
60
65
70
75
6
7
8
INPUT VOLTAGE (V)
FDC40-48S05 Derating Curve
FDC40-48S05
Efficiency VS Output load
EFFICIENCY (%)
3.
4.
5.
6.
Capacitor
Load max.
FDC40-24D15
OUTPUT POWER (%)
2.
Eff
(%)
FDC40-24D12
Note
1.
(6)
Input
Range
Model
Number
100
75
50
Nature convection
25
0
-40 -25 -10
0
50
60
70
AMBIENT TEMPERATURE (ºC)
80
90
100
90
89
88
86
84
82
80
70
60
50
45
0.5
1
2
3
4
OUTPUT LOAD (A)
5
0.40
0.40
0.60 (15.2) (10.2) (10.2)
2
4
3
Single
Dual
Triple
3.3V/5V
7
7
9
6
6
8
10
8
5
5
8
5
TRIM
UP
TRIM
DOWN
2.50 (63.5)
Bottom
View
3.00 (76.2)
EXTERNAL OUTPUT TRIMMING
0.40
(10.2)
DIA. 0.04 (1.0)
1
0.70 (17.8)
0.30 (7.6)
2.60 (66.0)
PIN CONNECTION
5
6
7
8
0.50
(12.7)
0.30 (7.6)
9
10
0.40
0.40
0.40
(10.2) (10.2) (10.2)
0.32
(8.0)
0.30 (7.6)
1. All dimensions in Inches (mm)
2. Pin pitch tolerance ±0.014(0.35)
PIN
SINGLE
DUAL
TRIPLE
3.3V / 5V
1
2
3
4
5
6
7
8
9
10
CTRL
+ INPUT
- INPUT
SYNC
TRIM DOWN
TRIM
TRIM UP
+ OUTPUT
- OUTPUT
NO PIN
CTRL
+ INPUT
- INPUT
SYNC
+ OUTPUT
CTRL
+ INPUT
- INPUT
SYNC
+ AUX
CTRL
+ INPUT
- INPUT
SYNC
+3.3V
COMMON
- OUTPUT
TRIM
NC
NC
COMMON (AUX)
- AUX
+ OUTPUT
- OUTPUT
TRIM
COMMON
+ 5V
TRIM
NC
NC
Converter 1
2
+ Vin
4
3
- Vin
+
Sync
-
Application of synchronization
1. The unit is capable of external synchronization from an
independent time base with a switching rate between 200kHz
and 215kHz
2. The amplitude of the synchronizing pulse train is TTL
compatible
3. The duty cycle of the CLK should be 20% high and 80% low
4. Synchronization is referenced to negative input (-Vin)
Converter 2
2
4
3
+
Sync
ON/OFF Control application
-
Converter
+ Vin
CLK
1
CLK Signal
80%
- Vin
ON/OFF Control
20%
2
3
+
CTRL
-