SECTION 7 ENERGY EFFICIENT GENERAL PURPOSE LOW VOLTAGE DISTRIBUTION TRANSFORMERS 600V Class, Single Phase & Three Phase Low Voltage Distribution Transformer Energy Efficiency Requirements......... HPS Energy Efficient Distribution Transformer Product Offering....................... 158 160 HPS Sentinel® Series - Energy Efficient General Purpose Transformers Standard Single Phase, Aluminum and Copper Specifications............................. HPS Sentinel® - Single Phase Selection Tables.......................................................... Standard Three Phase, Aluminum and Copper Specifications............................. HPS Sentinel® - Three Phase Selection Tables........................................................... 161 162 165 166 HPS Synergy® Series - Energy Efficient K-Factor Transformers K-Factor, Harmonics and Non-Linear Loads ............................................................. 173 Standard Three Phase, Aluminum and Copper Specifications............................. 175 HPS Synergy® - Three Phase Selection Tables........................................................... 176 HPS Centurion® Series - Energy Efficient Harmonic Mitigating Transformers 600V Class Harmonic Mitigating Transformer........................................................... 179 Standard Three Phase, Aluminum and Copper Specifications............................. 180 HPS Centurion® - Three Phase Selection Tables....................................................... 181 Enclosure Dimensional Drawings .................................................................................. 226 Accessories - Enclosure Mounting Kits, Anti-Vibration Pads & Isolators ...... 238 Termination Details ............................................................................................................. 242 SECTION 7 ENERGY EFFICIENT DISTRIBUTION TRANSFORMERS Low Voltage Distribution Transformers Energy Efficiency Requirements In the past decades, greenhouse gas emissions and their effects on our planet have become the focus of many governments, agencies, companies and individuals. Energy generation is a major contributor to greenhouse gas emissions. In addition to widespread efforts to make energy generation more environmentally friendly, lowering energy consumption within most industrial and commercial facilities also is a goal. HPS proudly supports these initiatives and is offering a complex Energy Efficient product basket that meets the current energy efficiency requirements both in US and Canada. Improving the energy efficiency of new transformers is a primary objective for regulatory bodies in both the U.S. and Canada. As a result the legislation issued by the U.S. Department of Energy - DOE 10 CFR p.431 and the Canadian Energy Efficiency Act – Energy Efficiency Regulations (SOR/94-651) have strict energy efficiency requirements for low-voltage dry-type and mediumvoltage dry-type distribution transformers. As the above legislation is evolving, HPS improves its energy efficient product lines to meet or exceed the prescribed levels of energy efficiency. HPS has a new line of energy efficient distribution transformers to meet the new DOE 10 CFR p.431 that comes in effect on January 1, 2016 also known as DOE 2016. More details about this product offer can be found in the HPS Sentinel Energy Efficient Distribution Transformer Selection Guide (DOESEL15). The Canadian product offer described in the current catalogue continues to comply with the CSA C802.2 energy efficiency requirements. This product line also meets the DOE energy efficiency levels that were in effect from January 1, 2007 to December 31, 2015 known also as TP-1 energy efficiency levels. SECTION 7 Effective December 1, 2015 our NEMA Premium product lines (SuperSentinel, SuperSynergy and SuperCenturion) are considered obsolete being replaced by the higher efficiency DOE 2016 product line. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 158 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT DISTRIBUTION TRANSFORMERS Low Voltage Distribution Transformers Canada - Energy Efficiency Regulations (CSA C802.2) The laws in Canada state that all low voltage dry-type distribution transformers (as defined below) manufactured after January 1st, 2005, must meet the minimum energy efficiency guidelines outlined by CSA C802.2 and referenced in the Canadian Energy Efficiency Act - Energy Efficiency Regulations (SOR/94-651). The range of product covered by these standards are: Primary (high) Voltage Up to 1.2 kV Secondary (low) Voltage Line Current Less than 4000 amps Dry-Type Rating Single Phase 15-333 kVA Three Phase 15-1000 kVA 60 Hz only Frequency For transformers exempted from the Canadian Efficiency Regulations please visit: http://laws.justice.gc.ca The HPS lines of 1.2 kV volt class energy efficient distribution transformers illustrated in this section, meet or exceed the minimum efficiencies required. These efficiencies are evaluated at 35% of the nameplate kVA transformer rating. The specifications covering 1.2 kV volt class energy efficiency in transformers in Canada are outlined in the CSA Efficiency Standard C802, “Maximum Losses for Distribution, Power and Dry-Type Transformers” as referenced in the Canadian Energy Efficiency Act - Energy Efficiency Regulations (SOR/94-651). CSA C802.2 Energy Efficiency Levels Dry-Type Distribution Transformers - Low Voltage Single Phase Three Phase Efficiency kVA Efficiency 15 25 37.5 50 75 100 167 250 333 97.70 98.00 98.20 98.30 98.50 98.60 98.70 98.80 98.90 15 30 45 75 112.5 150 225 300 500 750 1000 97.00 97.50 97.70 98.00 98.20 98.30 98.50 98.60 98.70 98.80 98.90 All efficiency values are at 35% of nameplate rated load DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 159 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 kVA SECTION 7 ENERGY EFFICIENT DISTRIBUTION TRANSFORMERS HPS Energy Efficient Distribution Transformer Product Offering: HPS offers three lines of energy efficient distribution transformers: Linear Load General Purpose Transformers (pages 161 to 172) General purpose distribution transformers are rated for 600 volts and below. They are generally used for supplying appliance, lighting, heating, motorized machine and power loads from electrical distribution systems. They are offered in a variety of enclosure types or as core & coil only. Non-Linear Load K-Factor Transformers (pages 173 to 178) The use of k-factor distribution transformers has become a popular means of supplying power fo non-linear loads such as electronic ballasts, drives, personal computers, telecommunications equipment, broadcasting equipment and other similar power electronics. These non-linear loads generate harmonic currents which can substantially increase transformer losses. Our K-rated transformers have been specifically designed to prevent failure due to overheating. K-factor is defined as a ratio between the additional losses due to harmonics and the eddy current losses at 60Hz. It is used to specify transformers for non-linear loads. Transformers with a rated k-factor of 4, 13, 20 and other are available. Harmonic Mitigating Transformers (pages 179 to 188) Harmonic Mitigating transformers are superior to the above transformers in that they reduce voltage distortion (flat-topping) and power losses due to current harmonics created by single-phase, non-linear loads such as computer equipment. Secondary windings are arranged to cancel zero sequence fluxes and eliminate primary winding circulating currents. They treat zero sequence harmonics (3rd, 9th and 15th) within the secondary windings and 5th and 7th harmonics upstream with appropriate phase shifting. SECTION 7 Our dual output, phase shifting Harmonic Mitigating Transformers provide extremely low output voltage distortion and input current distortion even under severe non-linear load conditions (data centers, internet service providers, telecom sites, call centers, broadcasting studios, etc.). Combining zero sequence flux cancellation with phase shifting treats 3rd, 5th, 7th, 9th, 15th, 17th and 19th harmonics within its secondary windings. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 160 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT GENERAL PURPOSE DISTRIBUTION HPS Sentinel® 600 VOLT CLASS ENERGY EFFICIENT GENERAL PURPOSE DISTRIBUTION TRANSFORMERS ALUMINUM & COPPER, SINGLE PHASE STANDARD SPECIFICATIONS 15 to 37.5 kVA 50 to 167 kVA 15 to 37.5 kVA 50 to 167 kVA Applications Energy efficient general purpose transformers are designed for linear loads and are most frequently used for applications such as commercial buildings to supply a variety of general loads. Efficiency Meets C802.2 efficiencies at 35% of rated load. Efficiencies are calculated under a linear load profile. UL Listed File: E112313 File: E112313 CSA Certified File: LR3902 File: LR3902 Frequency 60 Hz 60 Hz 220°C (150°C rise) 220°C (150°C rise) Heavy duty ventilated type 3R Heavy duty ventilated type 3R Enclosure Finish ANSI 61 Grey, UL50 ANSI 61 Grey, UL50 Standard Primary Taps Refer to wiring diagrams for details. Refer to wiring diagrams for details. Termination Front accessible separate high and low voltage terminals; connectors suitable for aluminum and copper are provided for easy cable installation. Front accessible separate high and low voltage terminals; connectors suitable for aluminum and copper are provided for easy cable installation. Conduit Knock-Outs Standard on all units (no knock-outs on Stainless Standard on 50 kVA, 75 kVA & 100 kVA units Steel enclosures). (no knock-outs on Stainless Steel enclosures). Impedance Typically 2.5% to 6.5% Typically 2.5% to 6.5% Mounting Floor or wall/ceiling mounting available. Refer to selection tables for details. Floor or wall/ceiling mounting available. Refer to selection tables for details. Seismic Seismically certified in accordance with IBC 2009; Section 1613 Earthquake Loads, for SDS <= 2.00g , z/h = 1.0, and IP = 1.5 Seismically certified in accordance with IBC 2009; Section 1613 Earthquake Loads, for SDS <= 2.00g , z/h = 1.0, and IP = 1.5 Meets NEMA ST-20 standards. Meets NEMA ST-20 standards. Insulation System Enclosure Type Optional type 4, 4X (stainless steel) and 12. (Optional low noise units available) (optional 115°C and 80°C rise available) Optional type 4, 4X (stainless steel) and 12. (Optional low noise units available) Other voltages and kVA sizes not listed in this section are available upon request for both aluminum and copper wound units. Standard features as listed above may differ. Please contact customer service for details, price and availability. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 161 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 Sound level (optional 115°C and 80°C rise available) SECTION 7 HPS SENTINEL® ALUMINUM WOUND, SINGLE PHASE 208 Primary Volts kVA 15 25 37.5 50 75 100 150 167 Catalog Number 120/240 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ4 NJ4 NMF015BE NMF025BE NMF037BE NMF050BE NMF075BE NMF100BE NMF150BE NMF167BE Width 19.40 23.90 23.90 26.00 32.00 32.00 32.00 32.00 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 32.50 50.00 32.50 50.00 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 170 220 260 375 500 650 850 950 F or W * F or W * F or W * F or W * F F F F SCD 32 SCD 31 SCD 31 SCD 2 SCD 39 SCD 39 SCD 39 SCD 39 kVA 15 25 37.5 50 75 100 150 167 Catalog Number NMF015LE NMF025LE NMF037LE NMF050LE NMF075LE NMF100LE NMF150LE NMF167LE 120/240 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NJ4 NJ4 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 32.00 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 32.50 50.00 32.50 50.00 kVA 15 25 37.5 50 75 100 150 167 Catalog Number Mtg Type W - Wall F - Floor (Pages 243 - 258) 170 220 260 370 500 650 850 900 F or W * F or W * F or W * F or W * F or W * F F F SCD 34 SCD 17 SCD 17 SCD 17 SCD 17 SCD 17 SCD 17 SCD 17 NMF015FE NMF025FE NMF037FE NMF050FE NMF075FE NMF100FE NMF150FE NMF167FE (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NJ4 NJ4 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 32.00 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 32.50 50.00 32.50 50.00 SECTION 7 kVA Catalog Number Mtg Type W - Wall F - Floor (Pages 243 - 258) 170 260 400 450 650 700 830 880 F or W * F or W * F or W * F or W * F or W * F F F SCD 32 SCD 31 SCD 31 SCD 31 SCD 31 SCD 39 SCD 39 SCD 39 15 25 37.5 50 75 100 150 167 NMF015HE NMF025HE NMF037HE NMF050HE NMF075HE NMF100HE NMF150HE NMF167HE (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NJ4 NJ4 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 32.00 Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 120/240 Secondary Volts Case Style 60 Hz Approx. Weight (Lbs.) For shielded units, please add the suffix “S” to the above part numbers. 416 Primary Volts Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 120/240 Secondary Volts Case Style 60 Hz Approx. Weight (Lbs.) For shielded units, please add the suffix “S” to the above part numbers. 277 Primary Volts Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. 240 X 480 Primary Volts 60 Hz Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 25.00 29.50 32.50 32.50 Height 21.50 28.75 28.75 38.00 38.00 41.00 50.00 50.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 220 260 400 480 650 850 900 F or W * F or W * F or W * F or W * F or W * F F F SCD 32 SCD 31 SCD 31 SCD 31 SCD 31 SCD 39 SCD 39 SCD 39 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. Note: For units smaller than 15kVA, please refer to the single phase encapsulated units in Section 8. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 162 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT GENERAL PURPOSE DISTRIBUTION ALUMINUM WOUND, SINGLE PHASE 600 Primary Volts kVA 15 25 37.5 50 75 100 150 167 Catalog Number NMF015PE NMF025PE NMF037PE NMF050PE NMF075PE NMF100PE NMF150PE NMF167PE 120/240 Secondary Volts Case Style (Pages 226- 234) NH5 NH6 NH6 NH3 NH3 NH4 NJ4 NJ4 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 32.00 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 32.50 50.00 32.50 50.00 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 220 220 260 400 480 650 850 900 F or W * F or W * F or W * F or W * F or W * F F F SCD 32 SCD 31 SCD 31 SCD 31 SCD 31 SCD 39 SCD 39 SCD 39 SINGLE PHASE, EXPORT MODEL 190/200/208/220 X 380/400/416/440 Primary Volts 120/240 Secondary Volts kVA Catalog Number 15 25 37.5 50 75 100 150 167 NMF015XE NMF025XE NMF037XE NMF050XE NMF075XE NMF100XE NMF150XE NMF167XE (Pages 226 - 234) NH6 NH6 NH6 NH3 NH3 NH4 Width 23.90 23.90 23.90 26.00 26.00 32.00 Approx. Dimensions (Inches) Depth 25.00 25.00 25.00 25.00 25.00 29.50 CONSULT FACTORY CONSULT FACTORY Height 28.75 28.75 28.75 38.00 38.00 41.00 50/60 Hz** Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 190 240 300 390 540 700 F or W * F or W * F or W * F or W * F or W * F F F SCD 30 SCD 30 SCD 30 SCD 30 SCD 30 SCD 30 SCD 30 SCD 30 COPPER WOUND, SINGLE PHASE kVA Catalog Number 15 25 37.5 50 75 100 150 167 NMF015BEC NMF025BEC NMF037BEC NMF050BEC NMF075BEC NMF100BEC NMF150BEC NMF167BEC 120/240 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NJ4 NJ4 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 32.00 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 25.00 29.50 32.50 32.50 Height 21.50 28.75 28.75 38.00 38.00 41.00 50.00 50.00 Mtg Type W - Wall F - Floor Catalog Number (Pages 243 - 258) 180 240 300 375 525 650 900 1000 F or W * F or W * F or W * F or W * F or W * F F F SCD 32 SCD 31 SCD 31 SCD 2 SCD 31 SCD 39 SCD 39 SCD 39 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 15 25 37.5 50 75 100 150 167 NMF015LEC NMF025LEC NMF037LEC NMF050LEC NMF075LEC NMF100LEC NMF150LEC NMF167LEC 120/240 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NJ4 NJ4 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 32.00 Wiring Diagram Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 25.00 29.50 32.50 32.50 Height 21.50 28.75 28.75 38.00 38.00 41.00 50.00 50.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 180 240 300 375 525 650 900 1000 F or W * F or W * F or W * F or W * F or W * F F F SCD 34 SCD 17 SCD 17 SCD 17 SCD 17 SCD 17 SCD 17 SCD 17 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please replace the suffix “C” with a ‘K’ on the above part numbers. Note: For units smaller than 15kVA, please refer to the single phase encapsulated units in Section 8. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 163 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 kVA 60 Hz Approx. Weight (Lbs.) For shielded units, please replace the suffix “C” with a ‘K’ on the above part numbers. 240 X 480 Primary Volts Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. **Note: Meets DOE 10 CFR Part 431 and C802.2 at 60 Hz. 208 Primary Volts Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details For shielded units, please add the suffix “S” to the above part numbers. Case Style 60 Hz SECTION 7 HPS SENTINEL® COPPER WOUND, SINGLE PHASE 277 Primary Volts kVA Catalog Number 15 25 37.5 50 75 100 150 167 NMF015FEC NMF025FEC NMF037FEC NMF050FEC NMF075FEC NMF100FEC NMF150FEC NMF167FEC 120/240 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NJ4 NJ4 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 32.00 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 25.00 29.50 32.50 32.50 Height 21.50 28.75 28.75 38.00 38.00 41.00 50.00 50.00 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 180 240 300 375 525 650 900 1000 F or W * F or W * F or W * F or W * F or W * F F F SCD 32 SCD 31 SCD 31 SCD 31 SCD 31 SCD 39 SCD 39 SCD 39 kVA 15 25 37.5 50 75 100 150 167 Catalog Number NMF015HEC NMF025HEC NMF037HEC NMF050HEC NMF075HEC NMF100HEC NMF150HEC NMF167HEC 120/240 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NJ4 NJ4 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 32.00 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 25.00 29.50 32.50 32.50 Height 21.50 28.75 28.75 38.00 38.00 41.00 50.00 50.00 600 Primary Volts 15 25 37.5 50 75 100 150 167 Catalog Number NMF015PEC NMF025PEC NMF037PEC NMF050PEC NMF075PEC NMF100PEC NMF150PEC NMF167PEC Mtg Type W - Wall F - Floor (Pages 243 - 258) 180 240 300 375 525 650 900 1000 F or W * F or W * F or W * F or W * F or W * F F F SCD 32 SCD 31 SCD 31 SCD 31 SCD 31 SCD 39 SCD 39 SCD 39 120/240 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NJ4 NJ4 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 32.00 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 32.50 50.00 32.50 50.00 SECTION 7 190/200/208/220 X 380/400/416/440 Primary Volts 15 25 37.5 50 75 100 150 167 NMF015XEC NMF025XEC NMF037XEC NMF050XEC NMF075XEC NMF100XEC NMF150XEC NMF167XEC Case Style (Pages 226 - 234) NH6 NH6 NH6 NH3 NH3 NH4 Width 23.90 23.90 23.90 26.00 26.00 32.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 180 240 300 375 525 650 900 1000 F or W * F or W * F or W * F or W * F or W * F F F SCD 32 SCD 31 SCD 31 SCD 31 SCD 31 SCD 39 SCD 39 SCD 39 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. SINGLE PHASE, EXPORT MODEL Catalog Number Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please replace the suffix “C” with a ‘K’ on the above part numbers. kVA 60 Hz Approx. Weight (Lbs.) For shielded units, please replace the suffix “C” with a ‘K’ on the above part numbers. kVA Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please replace the suffix “C” with a ‘K’ on the above part numbers. 416 Primary Volts 60 Hz 120/240 Secondary Volts Approx. Dimensions (Inches) Depth Height 25.00 28.75 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 CONSULT FACTORY CONSULT FACTORY 50/60 Hz** Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 190 240 300 390 540 700 F or W * F or W * F or W * F or W * F or W * F F F SCD 30 SCD 30 SCD 30 SCD 30 SCD 30 SCD 30 SCD 30 SCD 30 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. **Note: Meets DOE 10 CFR Part 431 and C802.2 at 60 Hz. Note: For units smaller than 15kVA, please refer to the single phase encapsulated units in Section 8. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 164 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT GENERAL PURPOSE DISTRIBUTION HPS Sentinel® 600 VOLT CLASS ENERGY EFFICIENT GENERAL PURPOSE DISTRIBUTION TRANSFORMER ALUMINUM & COPPER, THREE PHASE STANDARD SPECIFICATIONS 15 to 45 kVA 75 to 750 kVA 15 to 45 kVA 75 to 750 kVA Application Energy efficient general purpose transformers are designed for linear loads and are most frequently used for applications such as commercial buildings to supply a variety of general loads. Efficiency Meets C802.2 efficiencies at 35% of rated load. Efficiencies are calculated under a linear load profile. UL Listed File: E112313 File: E112313 CSA Certified File: LR3902 File: LR3902 Frequency 60 Hz 60 Hz Insulation System 220°C (150°C rise) 200°C (130°C rise) on 15 & 30kVA copper 220°C (150°C rise) Heavy duty ventilated type 3R Heavy duty ventilated type 3R Enclosure Finish ANSI 61 Grey, UL50 ANSI 61 Grey, UL50 Neutral Neutral terminal for field connection (on applicable units). Neutral terminal for field connection (on applicable units). Standard Primary Taps Refer to wiring diagrams for details. Refer to wiring diagrams for details. Termination Front accessible separate high and low voltage terminals; connectors suitable for aluminum and copper are provided for easy cable installation. Front accessible separate high and low voltage terminals; connectors suitable for aluminum and copper are provided for easy cable installation. Conduit Knock-Outs Standard on all units (no knock-outs on Stainless Steel enclosures). Standard on 75 kVA & 150 kVA units (no knock-outs on Stainless Steel enclosures). Impedance Typically 2.5% to 6.5% Typically 2.5% to 6.5% Mounting Floor or wall/ceiling mounting available. Refer to selection tables for details. Floor or wall/ceiling mounting available. Refer to selection tables for details. Seismic Seismically certified in accordance with IBC 2009; Section 1613 Earthquake Loads, for SDS <= 2.00g , z/h = 1.0, and IP = 1.5 Seismically certified in accordance with IBC 2009; Section 1613 Earthquake Loads, for SDS <= 2.00g , z/h = 1.0, and IP = 1.5 Meets NEMA ST-20 standards. Meets NEMA ST-20 standards. Enclosure Type Optional type 4, 4X (stainless steel) and 12. (Optional low noise units available) (optional 115°C and 80°C rise available) Optional type 4, 4X (stainless steel) and 12. (Optional low noise units available) Other voltages and kVA sizes not listed in this section are available upon request for both aluminum and copper wound units. Features as listed above may differ. Please contact customer service for details, price and availability. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 165 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 Sound level (optional 115°C and 80°C rise available) SECTION 7 HPS SENTINEL® ALUMINUM WOUND, THREE PHASE 208 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMK015BB NMK030BB NMK045BB NMK075BB NMK112BB NMK150BB NMK225BB NMK300BB NMK500BB NMK750BB 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243- 258) 200 280 375 540 775 850 1400 1700 2700 3250 F or W * F or W * F or W * F or W * F F F F F F SCD 7 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 25 SCD 25 kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMK015BK NMK030BK NMK045BK NMK075BK NMK112BK NMK150BK NMK225BK NMK300BK NMK500BK NMK750BK 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 SECTION 7 Catalog Number kVA Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 280 375 540 775 850 1400 1850 2700 3250 F or W * F or W * F or W * F or W * F F F F F F SCD 40 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 SCD 23 SCD 40 15 30 45 75 112.5 150 225 300 500 750 NMK015DB NMK030DB NMK045DB NMK075DB NMK112DB NMK150DB NMK225DB NMK300DB NMK500DB NMK750DB NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 208Y/120 Secondary Volts Case Style (Pages 226 - 234) 60 Hz Approx. Weight (Lbs.) For shielded units, please add the suffix “S” to the above part numbers. 240 Delta Primary Volts Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. 208 Delta Primary Volts 60 Hz Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 200 280 375 540 775 850 1400 1700 2700 3250 F or W * F or W * F or W * F or W * F F F F F F SCD 25 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 NO TAPS NO TAPS *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. Note: For units smaller than 15kVA, please refer to the three phase encapsulated units in Section 8. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 166 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT GENERAL PURPOSE DISTRIBUTION ALUMINUM WOUND, THREE PHASE 240 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMK015DK NMK030DK NMK045DK NMK075DK NMK112DK NMK150DK NMK225DK NMK300DK NMK500DK NMK750DK 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 280 375 540 775 850 1400 1700 2700 3250 F or W * F or W * F or W * F or W * F F F F F F SCD 40 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 NO TAPS NO TAPS kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMK015KB NMK030KB NMK045KB NMK075KB NMK112KB NMK150KB NMK225KB NMK300KB NMK500KB NMK750KB 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 280 375 540 775 850 1400 1400 2150 3200 F or W * F or W * F or W * F or W * F F F F F F SCD 7 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 20 SCD 20 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 15 30 45 75 112.5 150 225 300 500 750 NMK015KD NMK030KD NMK045KD NMK075KD NMK112KD NMK150KD NMK225KD NMK300KD NMK500KD NMK750KD 240 Delta/120 CT Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Wiring Diagram Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 200 280 375 540 775 850 1400 1700 2700 3250 F or W * F or W * F or W * F or W * F F F F F F SCD 13 SCD 21 SCD 21 SCD 21 SCD 21 SCD 21 SCD 21 SCD 21 SCD 22 SCD 22 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. Note: For units smaller than 15kVA, please refer to the three phase encapsulated units in Section 8. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 167 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 Catalog Number kVA 60 Hz Approx. Weight (Lbs.) For shielded units, please add the suffix “S” to the above part numbers. 480 Delta Primary Volts Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. 480 Delta Primary Volts 60 Hz SECTION 7 HPS SENTINEL® ALUMINUM WOUND, THREE PHASE 480 Delta Primary Volts Catalog Number kVA 15 30 45 75 112.5 NMK015KY NMK030KY NMK045KY NMK075KY NMK112KY 380Y/220, 400Y/231, 416Y/240, 430Y/248 Secondary Volts Case Style (Pages 226 - 234) NH6 NH6 NH6 NH3 NH3 Width 23.9 23.9 23.9 26 26 Approx. Dimensions (Inches) Depth Height 25 28.75 25 28.75 25 28.75 25 38 25 38 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 170 290 435 550 755 F or W* F or W* F or W* F F SCD 52 SCD 52 SCD 52 SCD 52 SCD 52 Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 NMK015KK NMK030KK NMK045KK NMK075KK NMK112KK NMK150KK NMK225KK NMK300KK NMK500KK NMK750KK 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 SECTION 7 Catalog Number kVA Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 280 375 540 775 850 1400 1700 2700 3250 F or W * F or W * F or W * F or W * F F F F F F SCD 25 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 20 SCD 20 15 30 45 75 112.5 150 225 300 500 750 NMK015PB NMK030PB NMK045PB NMK075PB NMK112PB NMK150PB NMK225PB NMK300PB NMK500PB NMK750PB NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 208Y/120 Secondary Volts Case Style (Pages 226 - 234) 60 Hz Approx. Weight (Lbs.) For shielded units, please add the suffix “S” to the above part numbers. 600 Delta Primary Volts Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. 480 Delta Primary Volts 60 Hz Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 200 280 375 540 775 850 1400 1700 2200 3250 F or W * F or W * F or W * F or W * F F F F F F SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 10 SCD 10 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. Note: For units smaller than 15kVA, please refer to the three phase encapsulated units in Section 8. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 168 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT GENERAL PURPOSE DISTRIBUTION ALUMINUM WOUND, THREE PHASE 600Y Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 NMK015PD NMK030PD NMK045PD NMK075PD NMK112PD NMK150PD NMK225PD NMK300PD NMK500PD NMK750PD 240 Delta Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 280 375 540 775 850 1400 1700 2700 3250 F or W * F or W * F or W * F or W * F F F F F F SCD 16 SCD 16 SCD 16 SCD 16 SCD 16 SCD 16 SCD 16 SCD 16 SCD 29 SCD 29 Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 NMK015PK NMK030PK NMK045PK NMK075PK NMK112PK NMK150PK NMK225PK NMK300PK NMK500PK NMK750PK 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. 600 Delta Primary Volts 60 Hz Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 200 280 375 540 775 850 1400 1700 2700 3250 F or W * F or W * F or W * F or W * F F F F F F SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 10 SCD 10 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please add the suffix “S” to the above part numbers. COPPER WOUND, THREE PHASE 208 Delta Primary Volts 15 30 45 75 112.5 150 225 300 500 750 NMK015BBCN NMK030BBC NMK045BBC NMK075BBC NMK112BBC NMK150BBC NMK225BBC NMK300BBC NMK500BBC NMK750BBC Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 200 300 400 600 850 975 1850 1850 2800 3550 F or W * F or W * F or W * F or W * F F F F F F SCD 7 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 25 SCD 25 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please replace the suffix “C” with “K” on the above part numbers. Note: For units smaller than 15kVA, please refer to the three phase encapsulated units in Section 8. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 169 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 Catalog Number kVA 208Y/120 Secondary Volts SECTION 7 HPS SENTINEL® COPPER WOUND, THREE PHASE 208 Delta Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 NMK015BKCN NMK030BKC NMK045BKC NMK075BKC NMK112BKC NMK150BKC NMK225BKC NMK300BKC NMK500BKC NMK750BKC 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 Height 21.50 28.75 28.75 38.00 38.00 41.00 41.00 51.50 59.00 66.00 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 300 400 600 850 975 1500 1850 2800 3550 F or W * F or W * F or W * F or W * F F F F F F SCD 40 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 SCD 23 SCD 23 kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMK015DBCN NMK030DBC NMK045DBC NMK075DBC NMK112DBC NMK150DBC NMK225DBC NMK300DBC NMK500DBC NMK750DBC 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 SECTION 7 Catalog Number kVA Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 300 400 600 850 975 1500 1850 2800 3550 F or W * F or W * F or W * F or W * F F F F F F SCD 40 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 NO TAPS NO TAPS 15 30 45 75 112.5 150 225 300 500 750 NMK015DKCN NMK030DKC NMK045DKC NMK075DKC NMK112DKC NMK150DKC NMK225DKC NMK300DKC NMK500DKC NMK750DKC (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 480Y/277 Secondary Volts Case Style 60 Hz Approx. Weight (Lbs.) For shielded units, please replace the suffix “C” with “K” on the above part numbers. 240 Delta Primary Volts Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please replace the suffix “C” with “K” on the above part numbers. 240 Delta Primary Volts 60 Hz Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 200 300 400 600 850 975 1500 1850 2800 3550 F or W * F or W * F or W * F or W * F F F F F F SCD 40 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 SCD 26 NO TAPS NO TAPS *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please replace the suffix “C” with “K” on the above part numbers. Note: For units smaller than 15kVA, please refer to the three phase encapsulated units in Section 8. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 170 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT GENERAL PURPOSE DISTRIBUTION COPPER WOUND, THREE PHASE 480 Delta Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 NMK015KBCN NMK030KBCN NMK045KBC NMK075KBC NMK112KBC NMK150KBC NMK225KBC NMK300KBC NMK500KBC NMK750KBC 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMK015KDCN NMK030KDCN NMK045KDC NMK075KDC NMK112KDC NMK150KDC NMK225KDC NMK300KDC NMK500KDC NMK750KDC Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 300 400 600 850 975 1500 1850 2500 3300 F or W * F or W * F or W * F or W * F F F F F F SCD 7 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 240 Delta/120 CT Secondary Volts Approx. Dimensions (Inches) Width Depth 19.40 20.20 23.90 25.00 23.90 25.00 26.00 25.00 26.00 25.00 32.00 29.50 32.00 29.50 39.50 34.00 48.50 38.40 51.50 43.40 Height 21.50 28.75 28.75 38.00 38.00 41.00 41.00 51.50 59.00 66.00 Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 300 400 600 850 975 1500 1850 2800 3550 F or W * F or W * F or W * F or W * F F F F F F SCD 13 SCD 21 SCD 21 SCD 21 SCD 21 SCD 21 SCD 21 SCD 21 SCD 22 SCD 22 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 15 30 45 75 112.5 150 225 300 500 750 NMK015KKCN NMK030KKCN NMK045KKC NMK075KKC NMK112KKC NMK150KKC NMK225KKC NMK300KKC NMK500KKC NMK750KKC 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Wiring Diagram Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 200 300 400 600 850 975 1500 1850 2800 3550 F or W * F or W * F or W * F or W * F F F F F F SCD 25 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 20 SCD 20 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please replace the suffix “C” with “K” on the above part numbers. Note: For units smaller than 15kVA, please refer to the three phase encapsulated units in Section 8. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 171 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 Catalog Number kVA 60 Hz Approx. Weight (Lbs.) For shielded units, please replace the suffix “C” with “K” on the above part numbers. 480 Delta Primary Volts Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. For shielded units, please replace the suffix “C” with “K” on the above part numbers. 480 Delta Primary Volts 60 Hz SECTION 7 HPS SENTINEL® COPPER WOUND, THREE PHASE 600 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMK015PBCN NMK030PBCN NMK045PBC NMK075PBC NMK112PBC NMK150PBC NMK225PBC NMK300PBC NMK500PBC NMK750PBC 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 300 400 600 850 975 1500 1850 2500 3550 F or W * F or W * F or W * F or W * F F F F F F SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 10 SCD 10 kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMK015PDCN NMK030PDC NMK045PDC NMK075PDC NMK112PDC NMK150PDC NMK225PDC NMK300PDC NMK500PDC NMK750PDC 240 Delta Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 Height 21.50 28.75 28.75 38.00 38.00 41.00 41.00 51.50 59.00 66.00 SECTION 7 kVA Catalog Number Mtg Type W - Wall F - Floor (Pages 243 - 258) 200 300 400 600 850 975 1500 1850 2800 3550 F or W * F or W * F or W * F or W * F F F F F F SCD 16 SCD 16 SCD 16 SCD 16 SCD 16 SCD 16 SCD 16 SCD 16 SCD 29 SCD 29 15 30 45 75 112.5 150 225 300 500 750 NMK015PKCN NMK030PKCN NMK045PKC NMK075PKC NMK112PKC NMK150PKC NMK225PKC NMK300PKC NMK500PKC NMK750PKC (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 480Y/277 Secondary Volts Case Style 60 Hz Approx. Weight (Lbs.) For shielded units, please replace the suffix “C” with “K” on the above part numbers. 600 Delta Primary Volts Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details For shielded units, please replace the suffix “C” with “K” on the above part numbers. 600Y Primary Volts 60 Hz Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 For shielded units, please replace the suffix “C” with “K” on the above part numbers. 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 200 300 400 600 850 975 1500 1850 2800 3550 F or W * F or W * F or W * F or W * F F F F F F SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 10 SCD 10 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. Note: For units smaller than 15kVA, please refer to the three phase encapsulated units in Section 8. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) For termination details see page 242 © Hammond Power Solutions Inc. 172 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT K-FACTOR HPS Synergy® Series 600V CLASS ENERGY EFFICIENT K-FACTOR TRANSFORMER The use of electronic equipment has continued to proliferate in both offices and industrial plants. These electronic devices are powered by either switching power supplies or a rectifier circuit. Examples of these devices include computers, fax machines, copiers, printers, cash registers, UPS’s and solid-state ballasts. They all contribute to the distortion of the current waveform and the generation of harmonics. HARMONICS AND NON-LINEAR LOADS Harmonics, in an electrical system, are currents created by non-linear loads that generate non-sinusoidal (non-linear) current waveforms. These current and voltage waveforms operate on frequencies that are in multiples of the fundamental 60 hertz frequency. That is, the fundamental frequency is at 60 hertz, the 2nd harmonic is at 120 hertz frequency (60 x 2), the 3rd at 180 hertz, and so forth. An example of a perfect waveform An example of harmonics Harmonics are principally the by-product of switch-mode power supply technology where AC is rectified to DC, and back again. In the process, a capacitor is charged in the first half-cycle and then discharged in the next half-cycle in supplying current to the load. This cycle is repeated. This action of recharging causes AC current to flow only during a portion of the AC voltage wave in abrupt pulses. These abrupt pulses distort the fundamental wave shape causing distortion to the various harmonic frequencies. Non-Linear Loads Today, non-linear loads make up the majority of all electrical demand. Rectified input, switching power supplies and electronic lighting ballasts are the most common single phase non-linear loads. Harmonic currents and voltages produced by single phase, non-linear loads which are connected phase-to-neutral in a three phase four wire system, are third order, zero sequence harmonics (the third harmonic and its odd multiples - 3rd, 9th, 15th, 21st, etc., phasors displaced by zero degrees). These third order, zero sequence harmonic currents do not cancel, but add up arithmetically on the neutral bus, creating a primary source of excessive neutral current. SECTION 7 DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 173 For accessories see pages 238 to 241 Data subject to change without notice. HPS SYNERGY® SECTION 7 HPS Synergy® Series 600V CLASS ENERGY EFFICIENT K-FACTOR TRANSFORMER continued... Energy efficient general purpose distribution transformers, most frequently used for applications such as commercial or institutional buildings, will supply widely varied single phase loads. Energy Efficient K-Factor transformers are energy efficient general purpose transformers, but are designed to tolerate the harmonic distortion associated with these loads. Harmonics indicate their presence in a number of ways: • • • • • Overheating Device malfunctions Telephone interference Equipment vibration Breakers tripping Harmonics For A 60Hz System SECTION 7 In a 60 Hz power system, the fundamental and harmonic frequencies are outlined in the table below. Fundamental 60 Hz 14th Harmonic 840 Hz 2nd Harmonic 120 Hz 15th Harmonic 900 Hz 3rd Harmonic 180 Hz 16th Harmonic 9600 Hz 4th Harmonic 240 Hz 17th Harmonic 1020 Hz 5th Harmonic 300 Hz 18th Harmonic 1080 Hz 6th Harmonic 360 Hz 19th Harmonic 1140 Hz 7th Harmonic 420 Hz 20th Harmonic 1200 Hz 8th Harmonic 480 Hz 21st Harmonic 1260 Hz 9th Harmonic 540 Hz 22nd Harmonic 1320 Hz 10th Harmonic 600 Hz 23rd Harmonic 1380 Hz 11th Harmonic 660 Hz 24th Harmonic 1440 Hz 12th Harmonic 720 Hz 25th Harmonic 1500 Hz 13th Harmonic 780 Hz K-Factor K-factor is defined as a ratio between the additional losses due to harmonics and the eddy current losses at 60Hz. It is used to specify transformers for non-linear loads. Transformers with a rated K-factor of 4, 7, 13, 20 and 30 are available. For balanced loading, a transformer with a K-factor of 4 should be specified when no more than 50% of the total load is non-linear. A transformer with K-factor 13 should be specified when 100% of the load is non-linear. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 174 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT K-FACTOR HPS Synergy® 600V CLASS ENERGY EFFICIENT K-FACTOR TRANSFORMERS ALUMINUM & COPPER, THREE PHASE STANDARD SPECIFICATIONS 15 to 45 kVA 75 to 750 kVA 15 to 45 kVA 75 to 750 kVA Application Most frequently used for applications such as commercial or institutional buildings, will supply widely varied single phase loads Efficiency Meets C802.2 efficiencies at 35% of rated load. Efficiencies are calculated under a linear load profile. UL Listed File: E112313 File: E112313 CSA Certified File: LR3902 File: LR3902 Frequency 60 Hz 60 Hz Insulation System 220°C (150°C rise) 200°C (130°C rise) on 15 & 30kVA copper 220°C (150°C rise) Electrostatic Shield 60dB Common Mode - typical 60dB Common Mode - typical Heavy duty ventilated type 3R Heavy duty ventilated type 3R Enclosure Finish ANSI 61 Grey, UL50 ANSI 61 Grey, UL50 Neutral Neutral terminal for field connection (on applicable units). Neutral terminal for field connection (on applicable units). Standard Primary Taps Refer to wiring diagrams for details. Refer to wiring diagrams for details. Termination Front accessible separate high and low voltage terminals; connectors suitable for aluminum and copper are provided for easy cable installation. Front accessible separate high and low voltage terminals; connectors suitable for aluminum and copper are provided for easy cable installation. Conduit Knock-Outs Standard on all units (no knock-outs on Stainless Steel enclosures). Standard on 75 kVA & 225 kVA units (no knockouts on Stainless Steel enclosures). Impedance Typically 2.5% to 6.5% Typically 2.5% to 6.5% Mounting Floor or wall/ceiling mounting available. Refer to selection tables for details. Floor or wall/ceiling mounting available. Refer to selection tables for details. Meets NEMA ST-20 standards. Meets NEMA ST-20 standards. Enclosure Type Optional type 4, 4X (stainless steel) and 12. (Optional low noise units available) (optional 115°C and 80°C rise available) Optional type 4, 4X (stainless steel) and 12. (Optional low noise units available) Other voltages and kVA sizes not listed in this section are available upon request for both aluminum and copper wound units. Features as listed above may differ. Features as listed above may differ. Please contact customer service for details, price and availability. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 175 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 Sound level (optional 115°C and 80°C rise available) HPS SYNERGY® SECTION 7 ALUMINUM WOUND, SHIELDED, THREE PHASE K-FACTOR 4 480 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT04K015KBS NMT04K030KBS NMT04K045KBS NMT04K075KBS NMT04K112KBS NMT04K150KBS NMT04K225KBS NMT04K300KBS NMT04K500KBS NMT04K750KBS Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 600 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT04K015PBS NMT04K030PBS NMT04K045PBS NMT04K075PBS NMT04K112PBS NMT04K150PBS NMT04K225PBS NMT04K300PBS NMT04K500PBS NMT04K750PBS 208Y/120 Secondary Volts Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Height 21.50 28.75 28.75 38.00 38.00 41.00 41.00 51.50 59.00 66.00 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor (Pages 243 - 258) 190 330 430 640 920 1050 1575 1830 2150 3375 F or W * F or W * F or W * F or W * F F F F F F SCD 7 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 20 SCD 20 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Wiring Diagram *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 208Y/120 Secondary Volts Case Style (Pages 226 - 234) Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 60 Hz Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 190 330 430 640 920 1050 1575 1830 3000 3375 F or W * F or W * F or W * F or W * F F F F F F SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 10 SCD 10 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. COPPER WOUND, SHIELDED, THREE PHASE K-FACTOR 4 SECTION 7 480 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT04K015KBKF NMT04K030KBKN NMT04K045KBK NMT04K075KBK NMT04K112KBK NMT04K150KBK NMT04K225KBK NMT04K300KBK NMT04K500KBK NMT04K750KBK 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 210 350 460 665 945 1070 1725 1925 2500 3300 F or W * F or W * F or W * F or W * F F F F F F SCD 7 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 20 SCD 20 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 600 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT04K015PBKF NMT04K030PBKN NMT04K045PBK NMT04K075PBK NMT04K112PBK NMT04K150PBK NMT04K225PBK NMT04K300PBK NMT04K500PBK NMT04K750PBK 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH3 NH4 NJ1 NJ1 NJ2 NJ3 Width 19.40 23.90 23.90 26.00 26.00 32.00 39.50 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 34.00 51.50 34.00 51.50 38.40 59.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 210 350 460 665 945 1070 1725 1925 2925 3375 F or W * F or W * F or W * F or W * F F F F F F SCD 9 SCD 9 SCD 19 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 10 SCD 10 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 176 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT K-FACTOR ALUMINUM WOUND, SHIELDED, THREE PHASE K-FACTOR 13 480 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT13K015KBS NMT13K030KBS NMT13K045KBS NMT13K075KBS NMT13K112KBS NMT13K150KBS NMT13K225KBS NMT13K300KBS NMT13K500KBS NMT13K750KBS Case Style (Pages 226 - 234) NH6 NH6 NH6 NH3 NH4 NH4 NJ1 NJ1 NJ3 NJ3 600 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT13K015PBS NMT13K030PBS NMT13K045PBS NMT13K075PBS NMT13K112PBS NMT13K150PBS NMT13K225PBS NMT13K300PBS NMT13K500PBS NMT13K750PBS 208Y/120 Secondary Volts Width 23.90 23.90 23.90 26.00 32.00 32.00 39.50 39.50 51.50 51.50 Approx. Dimensions (Inches) Depth 25.00 25.00 25.00 25.00 29.50 29.50 34.00 34.00 43.40 43.40 NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ1 NJ3 NJ3 Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 190 340 410 675 920 1050 1600 1830 3000 4300 F or W * F or W * F or W * F or W * F F F F F F SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 20 SCD 20 SCD 10 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 208Y/120 Secondary Volts Case Style (Pages 226 - 234) Height 28.75 28.75 28.75 38.00 41.00 41.00 51.50 51.50 66.00 66.00 60 Hz Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 39.50 51.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 29.50 29.50 34.00 34.00 43.40 43.40 Height 21.50 28.75 28.75 38.00 41.00 41.00 51.50 51.50 66.00 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 190 340 410 675 920 1050 1600 1900 3000 4300 F or W * F or W * F or W * F or W * F F F F F F SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 10 SCD 10 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. COPPER WOUND, SHIELDED, THREE PHASE K-FACTOR 13 480 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT13K015KBKF NMT13K030KBKN NMT13K045KBK NMT13K075KBK NMT13K112KBK NMT13K150KBK NMT13K225KBK NMT13K300KBK NMT13K500KBK NMT13K750KBK 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH6 NH6 NH6 NH3 NH4 NH4 NJ1 NJ1 NJ2 NJ3 Width 23.90 23.90 23.90 26.00 32.00 32.00 39.50 39.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 25.00 28.75 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 34.00 51.50 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 280 350 470 680 970 1200 1900 2150 3200 4500 F or W * F or W * F or W * F or W * F F F F F F SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 20 SCD 20 600 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT13K015PBKF NMT13K030PBKN NMT13K045PBK NMT13K075PBK NMT13K112PBK NMT13K150PBK NMT13K225PBK NMT13K300PBK NMT13K500PBK NMT13K750PBK 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH6 NH6 NH6 NH3 NH4 NH4 NJ1 NJ1 NJ2 NJ3 Width 23.90 23.90 23.90 26.00 32.00 32.00 39.50 39.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 25.00 28.75 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 34.00 51.50 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 295 350 480 700 970 1200 1900 2400 3200 4500 F or W * F or W * F or W * F or W * F F F F F F SCD 9 SCD 9 SCD 19 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 10 SCD 10 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 177 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. HPS SYNERGY® SECTION 7 ALUMINUM WOUND, SHIELDED, THREE PHASE K-FACTOR 20 480 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT20K015KBS NMT20K030KBS NMT20K045KBS NMT20K075KBS NMT20K112KBS NMT20K150KBS NMT20K225KBS NMT20K300KBS NMT20K500KBS NMT20K750KBS 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 CONSULT FACTORY 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 275 365 565 730 950 1400 1900 2400 3600 F or W * F or W * F or W * F or W * F F F F F SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 20 SCD 20 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 600 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT20K015PBS NMT20K030PBS NMT20K045PBS NMT20K075PBS NMT20K112PBS NMT20K150PBS NMT20K225PBS NMT20K300PBS NMT20K500PBS NMT20K750PBS 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 CONSULT FACTORY 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 275 365 565 730 950 1400 1900 2400 3600 F or W * F or W * F or W * F or W * F F F F F SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 10 SCD 10 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. COPPER WOUND, SHIELDED, THREE PHASE K-FACTOR 20 SECTION 7 480 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 NMT20K015KBKF NMT20K030KBKN NMT20K045KBK NMT20K075KBK NMT20K112KBK NMT20K150KBK NMT20K225KBK NMT20K300KBK NMT20K500KBK NMT20K750KBK 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 CONSULT FACTORY 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 275 440 700 860 1150 1600 2100 2600 3800 F or W * F or W * F or W * F or W * F F F F F SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 19 SCD 20 SCD 20 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 600 Delta Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 NMT20K015PBKF NMT20K030PBKN NMT20K045PBK NMT20K075PBK NMT20K112PBK NMT20K150PBK NMT20K225PBK NMT20K300PBK NMT20K500PBK NMT20K750PBK 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH6 NH6 NH3 NH3 NH4 NH4 NJ1 NJ2 NJ3 Width 23.90 23.90 26.00 26.00 32.00 32.00 39.50 48.50 51.50 Approx. Dimensions (Inches) Depth Height 25.00 28.75 25.00 28.75 25.00 38.00 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 CONSULT FACTORY 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 275 440 700 860 1150 1600 2100 2600 3800 F or W * F or W * F or W * F or W * F F F F F SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 9 SCD 10 SCD 10 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. Products listed on this page are available as ‘CE Mark’ products. Please consult our sales office. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 178 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT HARMONIC MITIGATING HPS Centurion® Series 600V CLASS HARMONIC MITIGATING TRANSFORMERS The HPS Centurion Energy Efficient, Harmonic Mitigating Transformers with zero sequence flux cancellation technology is specifically designed to treat the harmonics generated by computer equipment and other non-linear, power electronic loads. Harmonic mitigating transformers are superior to K-Rated and conventional transformers in reducing voltage distortion (flat-topping) and power losses due to current harmonics created by single-phase, non-linear loads such as computer equipment. Secondary windings are designed to cancel zero sequence fluxes and eliminate primary winding circulating currents. They treat zero sequence harmonics (3rd, 9th and 15th) within the secondary windings and 5th and 7th harmonics upstream with an appropriate phase shift. Dual Output Option Dual output, phase shifting HMT provides extremely low output voltage distortion and input current distortion even under severe non-linear loading conditions (Data Centers, Internet Service Providers, Telecom Sites, Broadcasting Studios, etc). Combining zero sequence flux cancellation with phase shifting treats 3rd, 5th, 7th, 9th, 15th, 17th and 19th harmonics within its secondary windings. HPS Centurion Series Harmonic Mitigating Transformer: Prevents voltage flat-topping caused by non-linear loads Reduces upstream harmonic currents Eliminates transformer overheating and high operating temperatures Eliminates primary winding circulating current Saves energy by reducing harmonic losses Maintains high energy efficiency even under non-linear loading conditions Electrostatic shielding for high frequency noise attenuation Lowers voltage distortion to prevent premature equipment failure Restores ride-through capability of computer equipment Treats power quality harmonic issues which K-rated transformers do not address Suitable for high K-factor loads Reduces current distortion at UPS, generator or Utility service Improves Upstream Total Power Factor SECTION 7 • • • • • • • • • • • • • DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 179 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 HPS CENTURION® HPS Centurion® 600V CLASS ENERGY EFFICIENT HARMONIC MITIGATING TRANSFORMERS THREE PHASE STANDARD SPECIFICATIONS 75 TO 750 KVA 15 to 45 kVA 15 to 45 kVA Application Typical applications of severe non-linear loading conditions include data centers, internet-service providers, telecom sites, call centers, broadcast centers, etc. Efficiency Meets C802.2 efficiencies at an operating range from 35% to 65% of rated linear load. Meets C802.2 efficiency standards when measured under a non-linear load profile up to K20 in an operating range from 35% to 50%. UL Listed File: E112313 File: E112313 CSA Certified File: LR3902 File: LR3902 Frequency 60 Hz 60 Hz Insulation System 220°C (150°C rise) 200°C (130°C rise) on 15 & 30kVA copper 220°C (150°C rise) Electrostatic Shield 60dB Common Mode - typical 60dB Common Mode - typical Heavy duty ventilated type 3R Heavy duty ventilated type 3R Enclosure Finish ANSI 61 Grey, UL50 ANSI 61 Grey, UL50 Neutral Neutral terminal for field connection (on applicable units). Neutral terminal for field connection (on applicable units). Standard Primary Taps Refer to wiring diagrams for details. Refer to wiring diagrams for details. Termination Front accessible separate high and low voltage terminals; connectors suitable for aluminum and copper are provided for easy cable installation. Front accessible separate high and low voltage terminals; connectors suitable for aluminum and copper are provided for easy cable installation. Conduit Knock-Outs Standard on all units (no knock-outs on Stainless Steel enclosures). Standard on 75 kVA & 150 kVA units (no knockouts on Stainless Steel enclosures). Impedance Typically 2.5% to 6.5% Typically 2.5% to 6.5% Mounting Floor or wall/ceiling mounting available. Refer to selection tables for details. Floor or wall/ceiling mounting available. Refer to selection tables for details. Meets NEMA ST-20 standards. Meets NEMA ST-20 standards. Enclosure Type SECTION 7 75 to 750 kVA Sound level (optional 115°C and 80°C rise available) Optional type 4, 4X (stainless steel) and 12 (Optional low noise units available) (optional 115°C and 80°C rise available) Optional type 4, 4X (stainless steel) and 12 (Optional low noise units available) * Optional TVSS available. Dual Output option also available. Features as listed above may differ. Contact sales for more details. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 180 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT HARMONIC MITIGATING ALUMINUM WOUND, THREE PHASE, SHIELDED 0° PHASE SHIFT 208 Delta Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 H1EM015BB00S H1EM030BB00S H1EM045BB00S H1EM075BB00S H1EM112BB00S H1EM150BB00S H1EM225BB00S H1EM300BB00S H1EM500BB00S H1EM750BB00S 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 208 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015BK00S H1EM030BK00S H1EM045BK00S H1EM075BK00S H1EM112BK00S H1EM150BK00S H1EM225BK00S H1EM300BK00S H1EM500BK00S H1EM750BK00S 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243- 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 480 Delta Primary Volts Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015KB00S H1EM030KB00S H1EM045KB00S H1EM075KB00S H1EM112KB00S H1EM150KB00S H1EM225KB00S H1EM300KB00S H1EM500KB00S H1EM750KB00S Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 181 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 kVA 208Y/120 Secondary Volts SECTION 7 HPS CENTURION® ALUMINUM WOUND, THREE PHASE, SHIELDED 0° PHASE SHIFT 480 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015KK00S H1EM030KK00S H1EM045KK00S H1EM075KK00S H1EM112KK00S H1EM150KK00S H1EM225KK00S H1EM300KK00S H1EM500KK00S H1EM750KK00S 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 600 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015PB00S H1EM030PB00S H1EM045PB00S H1EM075PB00S H1EM112PB00S H1EM150PB00S H1EM225PB00S H1EM300PB00S H1EM500PB00S H1EM750PB00S 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. SECTION 7 600 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015PK00S H1EM030PK00S H1EM045PK00S H1EM075PK00S H1EM112PK00S H1EM150PK00S H1EM225PK00S H1EM300PK00S H1EM500PK00S H1EM750PK00S 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 182 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT HARMONIC MITIGATING ALUMINUM WOUND, THREE PHASE, SHIELDED -30° PHASE SHIFT 208 Wye Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015BB30S H1EM030BB30S H1EM045BB30S H1EM075BB30S H1EM112BB30S H1EM150BB30S H1EM225BB30S H1EM300BB30S H1EM500BB30S H1EM750BB30S 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 208 Wye Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015BK30S H1EM030BK30S H1EM045BK30S H1EM075BK30S H1EM112BK30S H1EM150BK30S H1EM225BK30S H1EM300BK30S H1EM500BK30S H1EM750BK30S 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 43.40 Height 21.50 28.75 28.75 38.00 41.00 41.00 51.50 59.00 66.00 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 3200 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 480 Wye Primary Volts Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015KB30S H1EM030KB30S H1EM045KB30S H1EM075KB30S H1EM112KB30S H1EM150KB30S H1EM225KB30S H1EM300KB30S H1EM500KB30S H1EM750KB30S Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 183 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 kVA 208Y/120 Secondary Volts SECTION 7 HPS CENTURION® ALUMINUM WOUND, THREE PHASE, SHIELDED -30° PHASE SHIFT 480 Wye Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 H1EM015KK30S H1EM030KK30S H1EM045KK30S H1EM075KK30S H1EM112KK30S H1EM150KK30S H1EM225KK30S H1EM300KK30S H1EM500KK30S H1EM750KK30S 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 600 Wye Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 H1EM015PB30S H1EM030PB30S H1EM045PB30S H1EM075PB30S H1EM112PB30S H1EM150PB30S H1EM225PB30S H1EM300PB30S H1EM500PB30S H1EM750PB30S 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 43.40 Height 21.50 28.75 28.75 38.00 41.00 41.00 51.50 59.00 66.00 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. SECTION 7 600 Wye Primary Volts kVA 15 30 45 75 112.5 150 225 300 500 750 Catalog Number H1EM015PK30S H1EM030PK30S H1EM045PK30S H1EM075PK30S H1EM112PK30S H1EM150PK30S H1EM225PK30S H1EM300PK30S H1EM500PK30S H1EM750PK30S 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 43.40 Height 21.50 28.75 28.75 38.00 41.00 41.00 51.50 59.00 66.00 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 220 320 430 640 920 1100 1575 1830 2700 3800 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 184 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT HARMONIC MITIGATING COPPER WOUND, THREE PHASE, SHIELDED 0° PHASE SHIFT 208 Delta Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 H1EM015BB00 H1EM030BB00 H1EM045BB00 H1EM075BB00 H1EM112BB00 H1EM150BB00 H1EM225BB00 H1EM300BB00 H1EM500BB00 H1EM750BB00 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 208 Delta Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 H1EM015BK00 H1EM030BK00 H1EM045BK00 H1EM075BK00 H1EM112BK00 H1EM150BK00 H1EM225BK00 H1EM300BK00 H1EM500BK00 H1EM750BK00 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 480 Delta Primary Volts 15 30 45 75 112.5 150 225 300 500 750 H1EM015KB00 H1EM030KB00 H1EM045KB00 H1EM075KB00 H1EM112KB00 H1EM150KB00 H1EM225KB00 H1EM300KB00 H1EM500KB00 H1EM750KB00 Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 185 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 Catalog Number kVA 208Y/120 Secondary Volts SECTION 7 HPS CENTURION® COPPER WOUND, THREE PHASE, SHIELDED 0° PHASE SHIFT 480 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015KK00 H1EM030KK00 H1EM045KK00 H1EM075KK00 H1EM112KK00 H1EM150KK00 H1EM225KK00 H1EM300KK00 H1EM500KK00 H1EM750KK00 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 43.40 Height 21.50 28.75 28.75 38.00 41.00 41.00 51.50 59.00 66.00 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 600 Delta Primary Volts kVA 15 30 45 75 112.5 150 225 300 500 750 Catalog Number H1EM015PB00 H1EM030PB00 H1EM045PB00 H1EM075PB00 H1EM112PB00 H1EM150PB00 H1EM225PB00 H1EM300PB00 H1EM500PB00 H1EM750PB00 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 43.40 Height 21.50 28.75 28.75 38.00 41.00 41.00 51.50 59.00 66.00 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. SECTION 7 600 Delta Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015PK00 H1EM030PK00 H1EM045PK00 H1EM075PK00 H1EM112PK00 H1EM150PK00 H1EM225PK00 H1EM300PK00 H1EM500PK00 H1EM750PK00 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 186 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 ENERGY EFFICIENT HARMONIC MITIGATING COPPER WOUND, THREE PHASE, SHIELDED -30° PHASE SHIFT 208 Wye Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015BB30 H1EM030BB30 H1EM045BB30 H1EM075BB30 H1EM112BB30 H1EM150BB30 H1EM225BB30 H1EM300BB30 H1EM500BB30 H1EM750BB30 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 43.40 Height 21.50 28.75 28.75 38.00 41.00 41.00 51.50 59.00 66.00 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 208 Wye Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 H1EM015BK30 H1EM030BK30 H1EM045BK30 H1EM075BK30 H1EM112BK30 H1EM150BK30 H1EM225BK30 H1EM300BK30 H1EM500BK30 H1EM750BK30 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 43.40 Height 21.50 28.75 28.75 38.00 41.00 41.00 51.50 59.00 66.00 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 480 Wye Primary Volts Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015KB30 H1EM030KB30 H1EM045KB30 H1EM075KB30 H1EM112KB30 H1EM150KB30 H1EM225KB30 H1EM300KB30 H1EM500KB30 H1EM750KB30 Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth 20.20 25.00 25.00 25.00 29.50 29.50 34.00 38.40 43.40 43.40 Height 21.50 28.75 28.75 38.00 41.00 41.00 51.50 59.00 66.00 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 187 For accessories see pages 238 to 241 Data subject to change without notice. SECTION 7 kVA 208Y/120 Secondary Volts SECTION 7 HPS CENTURION® COPPER WOUND, THREE PHASE, SHIELDED -30° PHASE SHIFT 480 Wye Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015KK30 H1EM030KK30 H1EM045KK30 H1EM075KK30 H1EM112KK30 H1EM150KK30 H1EM225KK30 H1EM300KK30 H1EM500KK30 H1EM750KK30 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. 600 Wye Primary Volts Catalog Number kVA 15 30 45 75 112.5 150 225 300 500 750 H1EM015PB30 H1EM030PB30 H1EM045PB30 H1EM075PB30 H1EM112PB30 H1EM150PB30 H1EM225PB30 H1EM300PB30 H1EM500PB30 H1EM750PB30 208Y/120 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. SECTION 7 600 Wye Primary Volts kVA Catalog Number 15 30 45 75 112.5 150 225 300 500 750 H1EM015PK30 H1EM030PK30 H1EM045PK30 H1EM075PK30 H1EM112PK30 H1EM150PK30 H1EM225PK30 H1EM300PK30 H1EM500PK30 H1EM750PK30 480Y/277 Secondary Volts Case Style (Pages 226 - 234) NH5 NH6 NH6 NH3 NH4 NH4 NJ1 NJ2 NJ3 NJ3 Width 19.40 23.90 23.90 26.00 32.00 32.00 39.50 48.50 51.50 51.50 Approx. Dimensions (Inches) Depth Height 20.20 21.50 25.00 28.75 25.00 28.75 25.00 38.00 29.50 41.00 29.50 41.00 34.00 51.50 38.40 59.00 43.40 66.00 43.40 66.00 60 Hz Approx. Weight (Lbs.) Mtg Type W - Wall F - Floor Wiring Diagram (Pages 243 - 258) 240 360 465 740 1100 1350 1800 2250 3000 4200 F or W * F or W * F or W * F or W * F F F F F F SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 SCD 35 *Wall mounting kit and/or drip plate kit required. Refer to pages 238 to 239 for details. DOE 2016 product please see the HPS Sentinel® Energy Efficient Distribution Transformer Selection Guide (DOESEL15) © Hammond Power Solutions Inc. 188 For accessories see pages 238 to 241 Data subject to change without notice.
© Copyright 2026 Paperzz