(SEMU) for Luminance Mura in FPD Image Quality

Background Statement for SEMI Draft Document 4913A
Revision to SEMI D31-1102, with title change from “Definition of
Measurement Index (SEMU) for Luminance Mura in FPD Image Quality
Inspection” to “Definition of Measurement Index (DSEMU) for
Luminance Mura in FPD Image Quality Inspection”
Notice: This background statement is not part of the balloted item. It is provided solely to assist the recipient in
reaching an informed decision based on the rationale of the activity that preceded the creation of this Document.
Notice: Recipients of this Document are invited to submit, with their comments, notification of any relevant
patented technology or copyrighted items of which they are aware and to provide supporting documentation. In this
context, “patented technology” is defined as technology for which a patent has issued or has been applied for. In the
latter case, only publicly available information on the contents of the patent application is to be provided.
Background:
SEMI D31 is the standard regarding FPD Mura, which was published in 2002. At that time, the panels up to 20
inches had predominated in the FPD industry, which resulted in viewing distance limited to 50 cm. However,
recently, panels up to 100 inches have been on the market. As the panel size becomes larger, the viewing distance
changes accordingly. As a result, there have been many cases where SEMI D31 is not applicable.
Revision of SEMI D31 is proposed in this ballot to redefine the level of Mura by changing viewing distance
according to the size of panels.
This document was voted at the cycles 1 in 2011 and was rejected by the mismatch among formulas of DSEMU
Definition. This mismatch has been discussed carefully and corrected by the D31 Revision Task Force under the
Japan FPD Metrology Committee and Doc.#4913A has been prepared.
The voting results of Doc.#4913A will be reviewed by the D31 Revision Task Force and will be adjudicated at the
Japan FPD Metrology Committee on November, 2 at SEMI Japan, Tokyo, Japan
Finally, the D31 Revision Task Force and the Japan FPD Metrology Committee would like to thank and
acknowledge the Taiwan FPD committee for their great support to revise D31.
If you have any questions, please contact the D31 Revision Task Force co-leaders as shown below:
- Keizo Ochi (Konica Minolta Optics) at [email protected],
- Kosei Tanahashi (Samsung Electronics)
- Masao Kochi (Highland)
or
SEMI Staff
Naoko Tejima (SEMI Japan) at [email protected]
Semiconductor Equipment and Materials International
3081 Zanker Road
San Jose, CA 95134-2127
Phone: 408.943.6900, Fax: 408.943.7943
SEMI Draft Document 4913A
Revision to SEMI D31-1102, with title change from “Definition of
Measurement Index (SEMU) for Luminance Mura in FPD Image Quality
Inspection” to “Definition of Measurement Index (DSEMU) for
Luminance Mura in FPD Image Quality Inspection”
1 Purpose
1.1 This standard defines the index of measurement for mura in FPD image quality inspection.
1.2 This standard defines distance factor.
1.3 Based on the result of investigation for human eye’s sensitivity to mura in ergonomics approach, this standard
proposes an index for level of mura by expressing the function of the major axis and contrast of mura.
2 Scope
2.1 This standard is applicable to Flat Panel Display (FPD) excluding Cathode-ray Tube (CRT) and Head Mount
Display (HMD). Applicable display sizes are from Type 10 (10" diagonal) to Type 100 (100" diagonal). Viewing
distance ranges from 0.5 m to 5 m.
NOTICE: SEMI Standards and Safety Guidelines do not purport to address all safety issues associated with their
use. It is the responsibility of the users of the Documents to establish appropriate safety and health practices, and
determine the applicability of regulatory or other limitations prior to use.
3 Limitations
3.1 Mura to be measured is limited as below:
3.1.1 This standard is not applicable to line defects narrower than 300 µm and pixel dot defects.
3.1.2 Background display is limited to monochrome displays/intermediate gray scale level. This standard is not applicable to
color background such as RGB and L0/L63 background.
4 Referenced Standards and Documents
4.1 SEMI Standard
SEMI D57 ― Definition of Measurement Index (VCT) for Mura in FPD Image Quality Inspection
NOTICE: Unless otherwise indicated, all documents cited shall be the latest published versions.
5 Terminology
5.1 Abbreviations and Acronyms
5.1.1 DSEMU ― distance-considered SEMI Mura
5.1.2 JND ― just noticeable difference
5.2 Definitions
5.2.1 distance-considered SEMI Mura (DSEMU) ―measurement index for distance-linked mura
5.2.2 just noticeable difference (JND) ―used in the field of Psychophysics; for a certain stimulus, the smallest
change in stimulus (luminance, for example) where a difference can be perceived. Specifically, it is often used to
indicate a statistical value where the probability of the difference being “perceptible” is 50% and the probability of
the difference “not being perceptible” is 50%. This is also expressed as j.n.d. using lower case letters.
6 DSEMU Definition
6.1 Under specific conditions, the below regressive relationship is shown between the major axis and contrast for
Human Mura JND (Refer to Related Information 1).
Cjnd = F(d)
= 2.2K (1/d0.33)
(1)
Cjnd: Contrast of mura at JND (Unit: %, relative to background [=100%])
d: Major axis of mura at above contrast (Unit: mm)
This is a Draft Document of the SEMI International Standards program. No material on this page is to be construed as an official or adopted Standard or Safety Guideline.
Permission is granted to reproduce and/or distribute this document, in whole or in part, only within the scope of SEMI International Standards committee (document
development) activity. All other reproduction and/or distribution without the prior written consent of SEMI is prohibited.
Page 2
Doc. 4913A  SEMI
LETTER (YELLOW) BALLOT
DRAFT
Document Number: 4913A
Date: 7/14/2017
Semiconductor Equipment and Materials International
3081 Zanker Road
San Jose, CA 95134-2127
Phone: 408.943.6900, Fax: 408.943.7943
6.1.1 In the above equation, contrast at JND is inversely proportional to the major axis powered by 0.33. In short, it
indicates that as mura major axis gets shorter, darker muras are sensed.
6.2 For the subject mura, the mura level, DSEMU, is calculated using the below formula, from equation (R1-1),
(R2-1), (R1-3), (R1-4)
DSEMU = |Cx| / Cjnd [d=dx]
= |Cx| / F(dx)
= |Cx| / (2.2K (1/ dx0.33))
(2)
Cx: Average contrast of mura being measured (Unit: %, relative to background [=100%])
dx: Major axis of mura being measured (Unit: mm)
K: Distance factor (Unit: m): 0.2D2-0.2D+1
D: Viewing Distance
7 Notation
7.1 DSEMU is a comparison ratio between contrast of the measurement target and its major axis, and thus has no
unit.
8 Test Methods
8.1 Comparative Measurement and Direct Measurement — The two methods for determining DSEMU levels on
panels are comparative measurement and direct measurement.
8.1.1 Comparative Measurement
8.1.1.1 The comparative measurement method involves a panel and software which simulate DSEMU level, to
which a person compares a mura on an actual panel, making adjustments, until a level which appears similar is
determined. This is a method that is used in the actual production site easily using the DSEMU simulation panel as
the variable level limit sample.
8.1.2 Direct Measurement
8.1.2.1 The direct measurement method captures the actual panel with a CCD camera, or the like, and is a method
of measuring the DSEMU level of the mura section, making it possible to directly determine the DSEMU from the
major axis and contrast of the mura section that is captured.
8.2 Measurement Equipment
8.2.1 DSEMU measurement consists of measurement of the major axis of Mura on the display surface and contrast
measurement, and needs to be appropriately calibrated.
8.3 Measurement Environment
8.3.1 DSEMU measurement is conducted in a darkroom environment.
8.4 Display Conditions
8.4.1 Background luminance for DSEMU measurement shall be 50±5cd/m2.
8.5 Contrast Measurement
8.5.1 The average contrast of the mura section shall be measured, and the contrast ratio of the mura section will be
expressed as a percentage, while the background = 100%.
This is a Draft Document of the SEMI International Standards program. No material on this page is to be construed as an official or adopted Standard or Safety Guideline.
Permission is granted to reproduce and/or distribute this document, in whole or in part, only within the scope of SEMI International Standards committee (document
development) activity. All other reproduction and/or distribution without the prior written consent of SEMI is prohibited.
Page 3
Doc. 4913A  SEMI
LETTER (YELLOW) BALLOT
DRAFT
Document Number: 4913A
Date: 7/14/2017
Semiconductor Equipment and Materials International
3081 Zanker Road
San Jose, CA 95134-2127
Phone: 408.943.6900, Fax: 408.943.7943
APPENDIX 1
Definition of Measurement Index (SEMU) for Luminance Mura in FPD
Image Quality Inspection
NOTICE: The material in this Appendix is an official part of SEMI [designation number] and was approved by full
letter ballot procedures on [A&R approval date].
A1-1 Terminology
A1-1.1 Definitions
A1-1.1.1 Semu ― Semi Mura, Mmeasurement index for mura
A1-2 SEMU Definition
A1-2.1 Under specific conditions, the below regressive relationship can be seen between area and contrast for
Human Mura JND. (Refer to Related Information.)
Cjnd = F(S) = 1.97/S0.33 + 0.72
(A1-1)
Cjnd: Contrast of mura at JND (Unit: %, relative to background [=100%])
S: Area of mura at above contrast (Unit: mm2)
A1-2.1.1 In the above equation, contrast at JND is inversely proportional to area raised to the 0.33 power. In short,
it indicates that as mura area gets smaller, only darker muras are sensed.
A1-2.2 For the subject mura, the mura leveland Semu are be calculated using the below formula.
Semu = |Cx| / Cjnd [S=Sx]
= |Cx| / F(Sx)
= |Cx| / (1.97/Sx0.33 + 0.72)
Cx: Average contrast of mura being measured (Unit: %, relative to background [=100%])
Sx: Surface area of mura being measured (Unit: mm2)
(A1-2)
This is a Draft Document of the SEMI International Standards program. No material on this page is to be construed as an official or adopted Standard or Safety Guideline.
Permission is granted to reproduce and/or distribute this document, in whole or in part, only within the scope of SEMI International Standards committee (document
development) activity. All other reproduction and/or distribution without the prior written consent of SEMI is prohibited.
Page 4
Doc. 4913A  SEMI
LETTER (YELLOW) BALLOT
DRAFT
Document Number: 4913A
Date: 7/14/2017
Semiconductor Equipment and Materials International
3081 Zanker Road
San Jose, CA 95134-2127
Phone: 408.943.6900, Fax: 408.943.7943
RELATED INFORMATION 1
EXPERIMENT OUTLINE FOR CALCULATION OF MEASUREMENT
INDEX FOR LUMINANCE MURA IN FPD IMAGE QUALITY INSPECTION
NOTICE: This Related Information is not an official part of SEMI [designation number] and was derived from the
work of the global [committee name] Technical Committee. This Related Information was approved for publication
by full letter ballot procedures on [A&R approval date].
R1-1 Purpose
R1-1.1 It has been reported that under the range of certain conditions, a basic expression of FPD mura quality level
can be made, using their size and contrast. Here, recreating those experiments, we verified their reproducibility,
conducting the experiment with a goal of calculating a measurement index for luminance mura for standardization.
R1-2 Experiment Method
R1-2.1 Experiment Equipment
R1-2.1.1 The experiment utilized a 19.0 inch, 1240 X 768 pixel backlit TFT/LCD. As there was a need to display
low contrast luminance muras, it was reworked to display 256 gradations in a 43 cd/m2 ~ 54 cd/m2 range. A program
capable of displaying rectangular and round muras as desired was created, and the muras were displayed in the
center of the prepared LCD. The subjects could freely adjust the luminance of the displayed luminance muras using
a keyboard.
R1-2.2 Experiment Conditions
R1-2.2.1 21 types of muras were used. These were six round types (diameter: 2 mm, 5 mm, 10 mm, 25 mm, 50 mm,
100 mm) Observation conditions were a viewing distance of 0.5 m, 1 m, 2 m and view angle normal to the center of
the LCD. The experiment room was a darkroom, and the background luminance of the luminance mura was 50
cd/m2. As for ellipse types (2:1 or 3:1), they were observed for reference.
R1-2.3 Subjects/Experiment Procedure
R1-2.3.1 The subjects for the experiment were randomly-selected 66 adults. Of the 66 subjects, there was an Expert
group of 20, consisting of engineers from LCD makers, who regularly conduct mura inspections and analysis. The
remaining 46 subjects were college students and working people, a Novice group who conducted luminance mura
evaluation for the first time. Using the keyboard, the subjects adjusted the luminance of mura, to a point “where
mura can just no longer be detected” (referred to as “jnd”: just noticeable difference below) and to a “point where
mura can clearly be detected”. The contrasts were recorded at these times. Muras brighter than the background and
lighter than the background were both targeted. For the purpose of getting data from wide range of people, subjects
were randomly selected.
R1-3 Experiment Results
R1-3.1 It became clear from the experiment that the longer the major axis is, the smaller the contrast (C) became
(Muras are more visible as the major axis becomes longer).
R1-3.2 The relation between mura major axis and contrast showed the same trend as in past experience, and the
quality of reproducibility was confirmed. Therefore at this point, for the sake of standardization, we examined the
function for mura major axis, and tried linear regression for it with contrast. Figure R1-1 shows the results. When
the horizontal axis is 1/(d)0.33(d is the major axis of mura. Unit is mm) , and the vertical axis is contrast, the bold line
shows a strong correlation coefficient, understood through linear regression. However, when mura is larger than a
specific size, it is not always the case.
R1-3.3 Regression equation in Figure R1-1 is proposed as a basis for standardization.
Cjnd = 2.2 f(d)
(R1-1)
f(d) = 1/(d)0.33
(R1-2)
Multiply the above value by distance factor: K. This is the final equation.
Cjnd= 2.2f(d)K
(R1-3)
K = 0.2D2-0.2D+1
(R1-4)
D: Viewing Distance
This is a Draft Document of the SEMI International Standards program. No material on this page is to be construed as an official or adopted Standard or Safety Guideline.
Permission is granted to reproduce and/or distribute this document, in whole or in part, only within the scope of SEMI International Standards committee (document
development) activity. All other reproduction and/or distribution without the prior written consent of SEMI is prohibited.
Page 5
Doc. 4913A  SEMI
LETTER (YELLOW) BALLOT
DRAFT
Document Number: 4913A
Date: 7/14/2017
Semiconductor Equipment and Materials International
3081 Zanker Road
San Jose, CA 95134-2127
Phone: 408.943.6900, Fax: 408.943.7943
R1-4 Summary
R1-4.1 A proposal was made regarding the quantization of FPD luminance mura. The quality level of a mura is
expressed as a function between mura major axis and contrast, using the contrast at the jnd point as criteria.
mura contrast
(relative to background)
Unit: %
4.0
f(d) = 1/d0.33
3.5
3.0
2.5
2.0
1.5
1.0
縦軸、横軸は Note でな
く軸の下(横)に字タイ
トルを記載する
0.5
0.0
f(d)
Figure R1-1
Relation between the Major Axis of Luminance Mura and Contrast (Viewing Distance: 0.5 m)
mura contrast
(relative to background)
Unit: %
4.0
f(d) = 1/d0.33
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
f(d)
Figure R1-2
Relation between the Major Axis of Luminance Mura and Contrast (Viewing Distance: 1.0 m)
This is a Draft Document of the SEMI International Standards program. No material on this page is to be construed as an official or adopted Standard or Safety Guideline.
Permission is granted to reproduce and/or distribute this document, in whole or in part, only within the scope of SEMI International Standards committee (document
development) activity. All other reproduction and/or distribution without the prior written consent of SEMI is prohibited.
Page 6
Doc. 4913A  SEMI
LETTER (YELLOW) BALLOT
DRAFT
Document Number: 4913A
Date: 7/14/2017
Semiconductor Equipment and Materials International
3081 Zanker Road
San Jose, CA 95134-2127
Phone: 408.943.6900, Fax: 408.943.7943
4.0
f(d) = 1/d0.33
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
f(d)
Figure R1-3
Relation between the Major Axis of Luminance Mura and Contrast (Viewing Distance: 2.0 m)
NOTICE: Semiconductor Equipment and Materials International (SEMI) makes no warranties or representations as
to the suitability of the Standards and Safety Guidelines set forth herein for any particular application. The
determination of the suitability of the Standard or Safety Guideline is solely the responsibility of the user. Users are
cautioned to refer to manufacturer’s instructions, product labels, product data sheets, and other relevant literature,
respecting any materials or equipment mentioned herein. Standards and Safety Guidelines are subject to change
without notice.
By publication of this Standard or Safety Guideline, SEMI takes no position respecting the validity of any patent
rights or copyrights asserted in connection with any items mentioned in this Standard or Safety Guideline. Users of
this Standard or Safety Guideline are expressly advised that determination of any such patent rights or copyrights,
and the risk of infringement of such rights are entirely their own responsibility.
This is a Draft Document of the SEMI International Standards program. No material on this page is to be construed as an official or adopted Standard or Safety Guideline.
Permission is granted to reproduce and/or distribute this document, in whole or in part, only within the scope of SEMI International Standards committee (document
development) activity. All other reproduction and/or distribution without the prior written consent of SEMI is prohibited.
Page 7
Doc. 4913A  SEMI
LETTER (YELLOW) BALLOT
murad contrast
(relative to background)
Unit: %
DRAFT
Document Number: 4913A
Date: 7/14/2017