MCR technology Highly compact signal conditioners - MINI Analog Analog IN/Analog OUT 3-way signal conditioner OUT 1 U,I US OUT IN Sensor / Field + 1 2 – 2 + 3 – 4 U,I U,I OUT U,I 5 + 5 active 4-wire GND IN IN U,I PLC / DCS GND 1 +24V passive GND 2 6 – +24V GND 3 7 + GND 3 OUT D W H 6 8 – Configurable, up to 36 signal combinations +24V GND 3 POWER Ex: Zone 2 Div. 2 Housing width 6.2 mm Technical data Input data Input signal – Highly compact signal conditioner for electrical isolation, conversion, amplification, and filtering of standard analog signals – Up to 36 signal combinations can be configured using DIP switches – 3-way isolation – Low power consumption – Power supply possible through the foot element (DIN rail connector) – Standard configuration: 0 ... 10 V input, 0 ... 20 mA output U input 0 ... 5 V / 1 ... 5 V 0 ... 10 V / 2 ... 10 V approx. 100 kΩ U output 0 ... 5 V / 1 ... 5 V 0 ... 10 V / 2 ... 10 V approx. 12.5 V Input resistance Output data Output signal Maximum output signal No-load voltage Short-circuit current Load RB Ripple General data Supply voltage UB Nominal supply voltage Current consumption I input 0 ... 20 mA / 4 ... 20 mA approx. 50 Ω I output 0 ... 20 mA / 4 ... 20 mA 28 mA approx. 12.5 V approx. 22 mA ≥ 10 kΩ < 20 mVPP (at 10 kΩ) U output 19.2 V DC ... 30 V DC 24 V DC < 9 mA (voltage output, at 24 V DC incl. load) < 500 Ω (at 20 mA) < 20 mVPP (at 500 Ω) I output < 19 mA (current output, at 24 V DC incl. load) Power consumption < 200 mW (voltage output) < 450 mW (current output) Maximum transmission error Temperature coefficient Cut-off frequency (3 dB) Step response (10-90%) Electrical isolation Test voltage, input/output/supply Degree of protection Ambient temperature (operation) Mounting Housing material Dimensions W / H / D Screw connection solid / stranded / AWG Spring-cage connection solid / stranded / AWG EMC note Conformance / approvals Conformance ATEX UL, USA / Canada ≤ 0.1 % (of final value) < 0.01 %/K, typ. < 0.002 %/K approx. 100 Hz approx. 3.2 ms Basic insulation according to EN 61010 1.5 kV (50 Hz, 1 min.) IP20 -20 °C ... 65 °C any PBT 6.2 / 93.1 / 102.5 mm 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 26 - 12 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 12 Class A product, see page 625 Notes: To order a product with an order configuration, enter the required configuration by referring to the adjacent order key. Information about power bridging, system cabling, and marking components can be found from page 116 CE-compliant II 3 G Ex nA IIC T4 Gc X UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL EMC 2 D GL Ordering data Description MCR 3-way signal conditioner, for electrical isolation of analog signals Order configuration Screw connection Order configuration Spring-cage connection Standard configuration Screw connection Standard configuration Spring-cage connection 92 Type Order No. MINI MCR-SL-UI-UI MINI MCR-SL-UI-UI-SP MINI MCR-SL-UI-UI-NC MINI MCR-SL-UI-UI-SP-NC 2864383 2864710 2864150 2864163 Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com PHOENIX CONTACT Pcs. / Pkt. 1 1 1 1 MCR technology Highly compact signal conditioners - MINI Analog Order key MINI MCR-SL-UI-UI(-SP) (standard configuration entered as an example) Input Order No. 2864383 Output / 2864383 = MINI MCR-SLUI-UI 2864710 MINI MCR-SLUI-UI-SP IN03 IN01 IN02 IN03 IN04 IN05 IN06 = = = = = = / 0 ... 20 mA 4 ... 20 mA 0 ... 10 V 2 ... 10 V 0 ... 5 V 1 ... 5 V OUT01 OUT01 OUT02 OUT03 OUT04 OUT05 OUT06 = = = = = = / 0 ... 20 mA 4 ... 20 mA 0 ... 10 V 2 ... 10 V 0 ... 5 V 1 ... 5 V Factory calibration certificate (FCC) NONE NONE = without FCC Yes = with FCC (a fee is charged) YESPLUS = FCC with 5 measuring points (a fee is charged) Configuration table for input and output signals Input 0 - 10 V Output 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA 0 - 10 V 2 - 10 V 0-5V 1-5V 2 - 10 V 0-5V 1-5V 0 - 20 mA 4 - 20 mA DIP 1 OFF OFF ON ON ON ON OFF OFF ON ON ON ON OFF OFF ON ON ON ON OFF OFF ON ON ON ON OFF OFF ON ON ON ON OFF OFF ON ON ON ON DIP switch SW 2 DIP 3 DIP 4 OFF OFF OFF OFF ON OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON ON OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON ON OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF ON OFF OFF OFF OFF OFF OFF ON OFF OFF ON ON ON OFF OFF ON OFF OFF DIP 2 OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF ON ON DIP 5 OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF DIP switch SW 1 DIP 1 DIP 2 OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON DIP 6 OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF OFF ON OFF ON OFF ON OFF OFF OFF OFF OFF OFF Application example: level measurement 24V Level sensor 0...10V 0...20mA 1 IN OUT 5 2 GND1 GND2 6 Controller 3 UB+ UB+ 7 4 GND3 GND3 8 MINI MCR-SL-UI-UI 24V Mains voltage Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com For further information and full technical data, visit phoenixcontact.net/products PHOENIX CONTACT 93
© Copyright 2026 Paperzz