High Frequency Switch Mode Power Supply (Fan Cooling) Technical Instruction Version V1.3 Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. All rights reserved. The Instruction is not allowed to copy. The technical specification is subject to change without prior notice. Add:#12 Tianshan Sci-Tech Park, #319 Xiangjiang Rd, Shijiazhuang, China ZIP Code:050035 Fax:0311-86080409 Service hotline:0311-86032617 Web:www.sjzthdz.com TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 Catalogue CHAPTER 1 OVERVIEW ...................................................................................................................... - 1 §1.1 PREFACE................................................................................................................................. - 1 - §1.2 SYSTEM PERFORMANCE ..................................................................................................... - 1 - §1.3 MAIN FEATURES .................................................................................................................... - 1 - §1.4 MAIN FUNCTIONS .................................................................................................................. - 1 - §1.5 SPECIFICATION ...................................................................................................................... - 4 - §1.6 MODEL NAME ......................................................................................................................... - 5 - CHAPTER 2 MODULE CONFIGURAITON .................................................................................... - 5 §2.1 WORKING PRINCIPLE ............................................................................................................. - 5 - §2.2 SIZE AND DIMENSION ............................................................................................................. - 6 - §2.3 OPERATING INSTRUCTION .................................................................................................... - 9 - CHAPTER 3 SERVICE ENVIRONMENT ....................................................................................... - 12 - TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 Chapter 1 Overview §1.1 Preface “TH” series intelligent high-frequency switch power supply modules are specially developed to meet the demands of modern DC system. The charger rectifiers are designed with world leading patent technology “resonant voltage type soft switching power supply technology”. They feature high efficiency and stability, intelligent control, small size and light weight. The products listed in this manual are the fifth generation, which are of higher working frequency, smaller size and lighter weight compared with past products. Rated output voltage 220V and 110V RS-485 interface, easy to work with automation system. Applicable for electric and relevant industries. §1.2 System performance Modular design, N+1 hot backup, smooth expansion; Intelligent design, implement automatically via serial communication the following function: on/off, charging mode switch over, output voltage setting, output current setting, SYNC switch over and etc. With standard RS-485 interface, easy to work with automation system, “4-remotes” function. Hot swappable §1.3 Main Features High efficiency, over 93% High power converter frequency, small size and light weight. Isolation automatic current sharing technology, unevenness <±3%。 Built in output isolation diode LED digit display, display switchover button, V-adjust button, DIP on front panel, easy operation §1.4 Main Functions 1) Protection function Output voltage protection:To prevent the disastrous accident caused by output overvoltage, there is overvoltage protection circuit in the module. Once the output voltage is higher than the threshold, the module locks up automatically and fault indication light is on, the faulty module quits work automatically and doesn’t affect the normal operation of the entire system. The overvoltage protection threshold is set in the factory, 320V±15V for 220V series, 160V±5V for 110V series. Output current limit:The output current cannot increase infinitely. The maximum output current of is limited to 110% of the rated output current. If over load, the output voltage will drop to protect Short circuit protection:When short circuit, the output voltage drops to 0 immediately. Limit the -1- TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 short circuit current under 15% of rated output current. The module will not be damaged under short circuit state for a time, and resumes to work automatically after trouble shooting. V Load Short circuit I Fig.1 output characteristics Parallel protection:There is parallel protection circuit in each module to ensure that when the fault module quits the system, the normal work of other modules and the system won’t be affected. ·· · Module 1 Module 2 Protection circuit Protection circuit Module N Protection circuit + Fig.2 Parallel output diagram Over temperature protection:Over-temperature protection is mainly for protecting large power components. In particular case, when the temperature of the radiator is over the threshold 85℃, the charger module shuts down automatically to protect itself and resume to work after the temperature comes lower 75℃. Over current protection:to protect the high power converting components and no output if over load. Self recoverable. 2) Synchrotrans function:the modules in same working group are of synchrotrons function to ensure consistency of system running. They are: float/boost charging switchover, boost charging voltage adjust, float charging voltage adjust, charging current setting. 3) Measurement and display function:measure the output voltage, output current and working state and display on the LED screen. The user can easily get the running info of the system. 4) Fault alarm function:Display the fault code on the LED screen if any fault and the user can easily locate the fault and remove it. 5) Setting function Output voltage set -2- TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 Set the output voltage by use of the buttons on the front panel. Set right output voltage according to bus, charging state, float charging voltage, boost charging voltage and etc. Current limit set 10% - 110% settable Four remotes function Remote control:remote switch on/off, float/boost charging switchover Remote regulation:regulate the float/boost charging voltage, current threshold and over voltage alarm threshold; Remote metering:measure output voltage and current; Remote signaling:read the working state of the module 6) Communication function Communicate with host controller and other modules parallel connected via RS485. -3- TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 §1.5 Specification Model TH230D10NZ TH230D07NZ TH230D05NZ TH110D10NZ TH110D20NZ Output current(A) 10 7 5 10 20 Power(KW) 3 2.1 1.5 1.5 3 Weight (kg) 5 5 5 5 5 Cooling type Fan cooling Fan cooling Fan cooling Fan cooling Fan cooling ≤30℃ ≤30℃ ≤30℃ ≤30℃ ≤30℃ Item Radiator T-rise Input Min 323 323 323 323 323 voltage Typical 380 380 380 380 380 (VAC) Max 437 437 437 437 437 Output Min 176 176 176 88 88 voltage Typical 242 242 242 121 121 (VDC) Max 300 300 300 150 150 voltage regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% Current regulation ±1% ±1% ±1% ±1% ±1% Efficiency ≥93% ≥93% ≥93% ≥93% ≥92% Storage Min -40 -40 -40 -40 -40 temperature Typical 25 25 25 25 25 (℃) Max 60 60 60 60 60 Working Min -10 -10 -10 -10 -10 temperatur Typical 25 25 25 25 25 e (℃) Max 40 40 40 40 40 ±3% ±3% ±3% ±3% ±3% 3~8 3~8 3~8 3~8 3~8 ≤0.5% ≤0.5% ≤0.5% ≤0.5% ≤0.5% 320±15VDC 320±15VDC 320±15VDC 160±8VDC 160±8VDC Unbalance rate of load sharing Soft start time Ripple Over voltage protection The output current does not increase infinitely. When over load, there will be limited Automatic current limit constant current output. The maximum output current of is limited to 110% of the rated output current. Load grade Continuous working with Grade I(100%) rating output current Short circuit protection When short circuit, the module will protect itself from broken. Self recoverable Note:the influence of built in diode is neglected when mention voltage regulation Table 1 -4- TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 §1.6 Model name TH NZ Fan cooling, intelligent module Rated output current:20A,10A,7A,5A Module category: D electric power DC output voltage grade:220V,110V Chapter Module configuration §2.1 Working principle AC input Input protection DC output Bridge rectifier Passive PFC Overheat protection RS485 Smooth filter DC/DC convert Resonance voltage type double loop control circuit Microprocessor Digit display button&code switch Fig. 3 Functional block diagram -5- Smooth filter Feedback sampling Over voltage/current short circuit protection Output protection Current sharing control TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 §2.2 Size and dimension The fixing bolt on front panel is M4 The overview of module 3KW and lower power are same. The size is as follows: Fig.4:Front view Fig 5:Rear View Fig. 6:side view -6- TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Fig. 7(1) :Bore hole drawing Fig. 7(2) :3-room rack -7- Technical Instruction V1.3 TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 Fig 7(3) :4-room rack The connector (JMD18T) definition : Fig. 8 Terminal PIN SPEC DEFINE FUNCTION 1 Standard 12# A Input 380VAC 2 Standard 12# B Input 380VAC 3 Standard 12# C Input 380VAC 7 Standard 20# 485B COM B 8 Standard 20# 485A COM A 9 Standard 20# JL- Current share grounding -8- TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 10 Standard 20# JL+ Current share bus 15 Standard 12# DC+ DC output + 16 Standard 12# DC- DC output - 18 Standard 12# G Input grounding Table 2 NOTE: ① Undefined port is empty ② Keep a good ventilation around the charger module. ③ Connect according to the indication “current share +”, “current share -” to achieve the automatic current share. ② Wire terminal A and terminal B separately and connect with the host monitor (such as THJK002G-3 monitor) through terminal A & terminal B of RS485 A, which achieve communication between the module and monitor §2.3 Operation instruction 图 9 充电模块前面板示意图 Digit display screen Show the information including voltage, current, warning, OFF. Change over voltage/current display by the option button. In case alarm, check the fault code by option button. When power off, the OFF code displayed by pushing the option button. Indicating light There are 3 indicating lights and the functions are shown as table 3 Table 3 indication light function Indicator Power indicator Normal Abnormal ON OFF NO input voltage, the axuilary power inside the module does not work overheat(red) OFF ON Overheat inside the module fault(red) OFF ON Fault inside the module (green) Reasons -9- TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 Display option button For changing the display on LED screen. When the LED screen is output voltage, the user can read output current by pushing this option button and then come back output voltage by pushing again. Manual voltage regulating button The two built-in buttons on front panel are used for regulating the output voltage in manual mode. The voltage reduces 1V when push left button“▼”. And the output voltage will rise 0.5V when push the right button“▲”. Remark: this button works only in manual mode. Code switch For choosing control mode and communication address. The definition is shown as fig.9 Fig. 9 1.Control mode option code switch The leftmost code button is control mode option code, used for choosing automatic control mode or manual control mode. It is automatic control mode if this code is on the top and manual control mode if at the bottom. Shown as fig. 9 In automatic mode, the output voltages, current limit value, ON/OFF of the module are controlled by the host monitor and manual operation does not work. If the module is wired in switching power bus to charge the battery, normally select the automatic mode. In manual mode, the output voltage is regulated by the voltage regulating button mentioned above. The output voltage, current limits value and ON/OFF of the module are not controlled by host monitor. But those information could be transferred to the host monitor. If the module is wired in control bus and a stable voltage output required, the module should be set in manual mode. The user can set the output voltage manually and the current limit threshold is the 110% rated current. In parallel working, only one module could be set in manual mode and others should be set in automatic model. - 10 - TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 PS:The equalized/float charge voltage must be set same in each module when several modules work in parallel to prevent from damage the battery once host monitor fault . 2.Grouping DIP switch The second code button from left is grouping DIP switch (broadcast address identification code ) and used for identifying packets groups (Broadcasting Data packet.) if switch to the top side, the charger is in packet group 1, the broadcast address is 253, If switch to the bottom, the charger is in packet group 2, the broadcast address is 254; the address is 255 if send data to both groups. 3.Set DIP The right 4 communication addresses set DIP and the broadcast address identification code are composed of communication address set DIP switch, which is used for setting the communication address of the module. The address is binary number, and means 0 if the DIP is on the top and means 1 if at the bottom. The rightmost code among is the lowest digit and the leftmost code is the highest digit. For example: the set DIP is 5 digits, so the set range of communication address is 0~31. That is to say, maximally 32 modules could be connected to one serial port of the host controller. The address is the only sign the controller could identify each module and the address of each module must be different in one system. For one module, the communication address setting must be same as the address setting of the host controller module. Otherwise abnormal communication occurs. The address in controller is decimal digit and the relation table is as follows Table 4 Table 4 Relation between binary and decimal digit 二进 0000 0000 0001 0001 0010 0010 0011 0011 0100 0100 0101 0101 0110 0110 0111 0111 1 0 1 0 1 0 1 0 1 0 0 0 1 0 1 制 0 十进 制 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 二进 1000 1000 1001 1001 1010 1010 1011 1011 1100 1100 1101 1101 1110 1110 1111 1111 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 制 十进 制 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 For example:the DIP set above highlighted in black is binary digit 10101, corresponding decimal address is 21. This charger is in Group 2. Voltage/current inquiry Under voltage/current inquiry mode, switch over the display content between voltage and current on the LED screen by use of the switchover button V/A. If any fault, the fault information is display on the LED screen in fault code. Get the voltage display by press the switchover button. The fault code table 5 is as follows. - 11 - TonHe Shijiazhuang Tonhe Electronics Technologies Co.,Ltd. Technical Instruction V1.3 Table 5 Fault code and definition Code E01 E02 E04 E05 Identification Under voltage Over voltage Over voltage/current protection Over temperature E06 E20 Setting over range Input fault Communication function Communicate with superior end via RS485. Transfer the output voltage, current, protection and alarm information to superior end and execute the upper controller’s commands. Table 6 Communication function No. Item Spec 1 Remote signaling Transfer the faults info such as AC input, DC output over/under voltage, over temperature to monitor unit 2 Remote measuring 3 Remote control 4 Remote regulating Measure charging module output voltage, current and display in the screen. Same time transfer to superior monitor unit Control the switch on/off of the charging module and equalizing/float charge convert according the command from monitor Regulate the output voltage according to commands Regulate output current limit threshold within 10%~ 100% according to commands. Note ~ ~ With Manual control function, which disable the monitor function Note: When the charging module is in automatic mode, the output voltage will be adjusted to 234V automatically if there is not any communication in 4 minutes. Current limiting threshold will be open all to 110% of rated current value. Chapter 3 Working environment 3.1 Altitude 2000m; 3.2 Storage temperature: -40℃~+60℃; working temperature: -10C ~ +40C; 3.3 Relative humidity: 90%(operating temperature 25C); 3.4 No conductive and explosive dust, no caustic gas; 3.5 Indoor use only 3.6 If your circumstance and conditions cannot meet the request above, please mention it when placing the order so that we can adjust to make sure the products work normally. - 12 -
© Copyright 2026 Paperzz