Fuse-links with blade contacts FUSE-LINKS PN PN fuse-links with blade contacts and with utilization category gG feature high breaking capacity, high current limiting capacity and low values of overvoltage during fuse-link action. These fuse-links are suitable for the use in fuse switch-disconnectors, fuse-rails and fuse-bases. Fuse-links with blade contacts PN In Utilization category gG Size [A] 4 6 8 10 12 16 20 000 25 32 (00C) 35 40 50 63 80 100 125 160 63 80 00 100 125 160 6 10 16 20 25 32 35 40 50 1 63 80 100 125 160 200 224 250 32 35 40 50 63 80 100 125 2 160 200 224 250 315 350 400 1) Un = 400 V a.c. D4 Type PN000 6A gG PN000 10A gG PN000 16A gG PN000 20A gG PN000 25A gG PN000 32A gG PN000 35A gG PN000 40A gG PN000 50A gG PN000 63A gG PN000 80A gG PN000 100A gG PN000 125A gG PN000 160A gG 1) PN00 125A gG PN00 160A gG PN1 6A gG PN1 10A gG PN1 16A gG PN1 20A gG PN1 25A gG PN1 32A gG PN1 35A gG PN1 40A gG PN1 50A gG PN1 63A gG PN1 80A gG PN1 100A gG PN1 125A gG PN1 160A gG PN1 200A gG PN1 224A gG PN1 250A gG PN2 32A gG PN2 35A gG PN2 40A gG PN2 50A gG PN2 63A gG PN2 80A gG PN2 100A gG PN2 125A gG PN2 160A gG PN2 200A gG PN2 224A gG PN2 250A gG PN2 315A gG PN2 350A gG PN2 400A gG Power Product losses code [W] 07008 1.09 07010 1.42 07011 2.16 07012 2.3 07013 2.88 07014 2.86 07015 3.22 07016 3.14 07017 3.98 07018 4.94 10419 6.09 10420 6.88 13365 7.13 13366 9.0 07058 7.93 07060 9.0 10408 1.29 10409 1.72 07197 2.67 07201 2.86 07205 3.55 07209 3.32 07213 3.64 07217 4.2 07221 4.6 07225 6.1 07229 6.67 07233 7.82 07237 9.34 07241 11.07 07100 14.44 07104 16.1 07107 17.8 34360 2.99 07245 3.31 07249 3.65 07253 4.25 07257 5.49 07261 6.81 07265 8.21 07269 10.63 07273 12.1 07277 14.14 07281 15.81 07285 17.35 07125 20.07 07128 21.53 07130 25.4 Utilization category gG for protection of lines, cables and other equipment against overload and short circuit. Utilization category aM for protection of motors, overcurrent relays, contactors and similar devices only against short circuit. The fuse-links do not contain harmful substances according to RoHS Regulation (cadmium, lead and other). Utilization category aM Type PN000 PN000 PN000 PN000 PN000 PN000 PN000 PN000 PN000 4A aM 6A aM 8A aM 10A aM 12A aM 16A aM 20A aM 25A aM 32A aM PN000 40A aM PN000 50A aM PN00 63A aM PN00 80A aM PN00 100A aM PN00 125A aM PN00 160A aM PN1 40A aM PN1 50A aM PN1 63A aM PN1 80A aM PN1 100A aM PN1 125A aM PN1 160A aM PN1 200A aM PN1 250A aM PN2 125A aM PN2 160A aM PN2 200A aM PN2 250A aM PN2 315A aM PN2 400A aM Power Product losses code [W] 07803 0.4 07143 0.5 07804 0.6 07144 0.6 07805 0.7 07145 0.9 07146 1.1 07147 1.4 07148 1.8 07149 2.4 07150 3.1 07155 4.6 07157 6.8 07158 7.5 15195 7 15196 9 10496 3.3 10497 4.2 10498 5.4 10499 7.1 10500 7.4 10501 8.3 10502 11.7 07171 17 07173 19.5 10503 8.6 10504 12.5 10505 16 10506 18.5 07179 28 07181 34 Weight Packing [kg] [pcs] 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.13 0.16 0.16 0.16 0.13 0.13 0.13 0.16 0.16 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.22 0.52 0.52 0.52 0.44 0.44 0.44 0.44 0.44 0.44 0.44 0.44 0.44 0.44 0.44 0.44 0.59 0.59 0.59 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Fuse-links with blade contacts FUSE-LINKS PN Fuse-links with blade contacts PN Utilization category gG Size Power In Product losses [A] Type code [W] 80 PN3 80A gG 34398 7.34 100 PN3 100A gG 07289 8.16 125 PN3 125A gG 07293 10.59 160 PN3 160A gG 07297 12.4 200 PN3 200A gG 07301 14.56 PN3 224A gG 07305 15.7 3 224 250 PN3 250A gG 07309 17.2 315 PN3 315A gG 07313 19.5 350 PN3 350A gG 07317 21.6 400 PN3 400A gG 07321 25.6 500 PN3 500A gG 07137 31.85 630 PN3 630A gG 07140 40.32 630 PN4a 630A gG 34386 43.0 800 PN4a 800A gG 34387 59.0 4a 1000 PN4a 1000A gG 34388 84.0 1250 PN4a 1250A gG 34389 104.0 1600 PN4a 1600A gG 34390 148.0 Utilization category aM Power Product losses code [W] 10507 26.2 10508 33.2 07185 40 07186 47 - Type PN3 PN3 PN3 PN3 315A 400A 500A 630A - aM aM aM aM Weight Packing [kg] [pcs] 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 0.61 061 1.08 1.08 2.0 2.0 2.0 2.0 2.0 3 3 3 3 3 3 3 3 3 3 3 3 1 1 1 1 1 * Fuse-links PN4a are not manufactured in Cd/Pb free version Parameters Rated voltage Un Breaking capacity (rms) I1 500 V a.c. (PN000 160A gG - 400 V a.c.) 250 V d.c. 120 kA/500 V a.c. 50 kA/250 V d.c. gG aM Utilization category Discrimination 1 : 1.6 Standards IEC 60269 DIN 43620, EN 60269 Approval marks . Dimensions . . . Size 000 00 00*) 1 (01) 1 2 (02) In [A] a1 a2 a3 a4 b (min) c1 d e1 e2 f 160 78.5±1.5 52±2 45±1.2 49±1.5 15 35±0.8 2±0.3 39.4±0.8 20.4±0.6 7+1 160 78.5±1.5 52±2 45±1.5 49±1.5 15 35±0.8 2±0.5 35±0.8 29±0.7 8+2 160 78.5±1.5 52±2 45±1.5 49±1.5 15 35±0.8 2+0.6 45±0.9 29±0.7 12+2 160 135±2.2 70±2 62+2 68±2.2 15 40±0.8 2.5±0.5 45±0.9 29±0.7 12+2 250 135±2 70.5±2 61±2.5 68±2 20 40±0.8 2.7±0.3 50±1 44±1 12+2 250 150±2 70.5±2 61±1.5 68±2 20 48±0.8 2.7±0.3 50±1 44±1 12+2 *) for PN00 125A and 160A aM, gG D5 Fuse-links with blade contacts FUSE-LINKS PN Dimensions Size In [A] a1 a2 a3 a4 b (min) c1 d e1 e2 f 2 3 (03) 3 4a 4a 400 150±2 70.5+2 61±1.5 68±2 25 48±0.8 2.7±0.3 58±1.3 50±1.3 12+2 400 150±2 70.5+2 61±1.5 68±2 25 60±0.8 2.7±0.3 58±1.3 50±1.3 12+2 630 150±2 73.5+1.5 61±2.5 68±2 32 60±0.8 3.5±0.2 73±1.5 71±1.5 15+2 1000 200±3 86.5 84±3 90±3 50 85±2 3 102 87 30 1600 200±3 97 84±3 90±3 50 85±2 3 110 95 30 Characteristics 4 125 160 10 I n [A] 125 160 20 25 6 10 16 4 Prearcing time/current characteristic PN00 125 and 160A gG 32 35 40 50 63 80 100 10 In [A] Prearcing time/current characteristic PN000 6 ÷ 160A gG 2h 2h 5 5 1h 1h 30 30 10 20 3 10 10 5 20 3 10 5 4 4 10 2 2 10 1min 5 2 2 1min 5 40 40 20 20 10 1 10 10 6 5 1 10 6 5 4 4 2 2 10 0 10 1s 100 -2 10 -3 1ms 100 10 -2 10 10 -3 1ms 5 -4 10 10 1 5 10 2 5 I p [A] D6 -1 5 5 10 10 5 5 10 t v [s] t v [s] -1 5 10 1s 5 5 10 0 10 3 5 10 4 -4 10 1 5 10 2 5 I p [A] 10 3 5 10 4 Fuse-links with blade contacts FUSE-LINKS PN Characteristics 32 35 40 50 63 80 100 125 160 200 224 250 16 20 25 6 10 In [A] 4 4 10 32 35 40 50 63 80 100 125 160 200 224 250 315 350 400 10 In [A] Prearcing time/current characteristic PN2 gG Prearcing time/current characteristic PN1 gG 2h 2h 5 5 1h 1h 30 30 10 20 3 10 5 20 3 10 10 5 4 4 10 2 2 1min 5 2 2 10 1min 5 40 40 20 10 1 20 1 10 10 6 5 10 6 5 4 4 2 0 2 1s -1 100 -2 -2 10 10 5 -3 1ms -3 10 5 10 100 5 5 10 -1 10 5 10 1s 5 t v [s] t v [s] 5 10 0 10 1ms 5 -4 10 1 5 10 2 10 5 3 5 10 10 4 -4 5 10 2 5 10 4 1h 630 4 800 1000 1250 10 5 2h 5 In [A] Prearcing time/current characteristic PN4a gG 160 200 224 250 315 350 400 500 630 In [A] 80 100 125 4 3 I p [A] Prearcing time/current characteristic PN3 gG 10 10 5 I p [A] 1600 10 1h 30 10 20 3 10 5 10 5 30 20 3 10 4 10 4 2 2 10 5 1min 5 40 2 2 1min 40 20 20 1 6 5 4 2 10 0 10 5 t v [s] -1 100 10 5 10 10 5 1ms 10 5 5 10 -2 5 10 -3 5 10 -4 10 2 5 10 3 5 I p [A] 10 4 5 10 5 1 10 6 4 2 1s 5 10 10 5 10 t v [s] 10 10 0 1s -1 100 -2 10 -3 1ms -4 10 2 5 10 3 5 10 4 5 10 5 Ip [A] D7 Fuse-links with blade contacts FUSE-LINKS PN Characteristics I2t characteristic PN000 ÷ 4a gG Cut-off characteristic PN000 ÷ 4a gG ~500V ~500V cos ϕ = 0.1 - 0.3 cos ϕ = 0.1 - 0.3 10 10 7 8 1600 1250 5 5 1000 800 10 10 6 7 I n[A] 5 5 630 500 400 I n [A] 1250 5 630 500 350 315 224 200 5 125 10 63 35 4 100 50 32 20 5 10 1000 350 315 6 800 400 250 5 250 224 200 10 125 100 160 160 I2 ttotal [A2 s] Ic [A] 10 1600 80 40 25 5 80 5 16 63 10 50 6 10 40 35 32 3 10 5 4 5 25 20 10 2 10 2 10 5 3 5 10 4 5 10 5 5 10 6 Ip [A] 10 3 16 5 10 10 6 2 10 2 5 10 3 5 10 4 5 I p [A] Correction factor „k“ of I2t dependence on operating voltage (I2t total) f(U) = k x I2t total PN000 ÷ 4a gG k 1.2 1.0 0.8 0.6 100 200 300 400 U [V] D8 500 600 10 5 5 10 6 Fuse-links with blade contacts FUSE-LINKS PN Characteristics Prearcing time/current characteristic PN000 aM 10 Prearcing time/current characteristic PN00 aM 4 10 5 4 5 1h 1h 30 10 10 10 2 8 20 3 10 5 4 10 12 16 20 25 32 40 50 6 4 In [A] 5 10 30 20 3 4 2 10 1min 5 2 2 1min 5 40 40 20 10 20 10 10 6 5 1 10 6 5 4 4 2 10 0 2 1s 10 10 1s -1 100 -2 10 5 -1 100 t v [s] t v [s] 5 0 5 10 5 10 -2 10 10 5 5 10 -3 1ms 10 5 -3 1ms In [A] 5 10 -4 10 1 5 10 2 5 10 3 5 10 10 4 63 100 125 160 -4 10 2 5 10 3 Ip [A] 5 10 4 5 4 1h 10 5 4 10 5 3 10 5 2 10 5 1 10 5 0 1h 30 20 30 1min 5 40 4 250 315 400 2 I n [A] 100 125 160 200 250 80 40 50 63 I n [A] 2 10 4 160 200 10 125 20 3 5 10 2 1min 40 20 10 5 Prearcing time/current characteristic PN2 aM 5 10 10 Ip [A] Prearcing time/current characteristic PN1 aM 10 80 1 20 10 6 5 4 10 6 4 2 10 0 2 1s 10 -1 100 5 10 -2 -3 5 10 10 5 10 10 5 1ms 10 5 5 10 t v [s] t v [s] 5 -4 10 2 5 10 3 5 Ip [A] 10 4 5 10 5 10 1s -1 100 -2 10 -3 1ms -4 10 2 5 10 3 5 10 4 5 10 5 Ip [A] D9 Fuse-links with blade contacts FUSE-LINKS - PN Characteristics Time/current ranges PN000 ÷ 3 aM Prearcing time/current characteristic PN3 aM 4 10 10 5 3 10 5 2 10 10 2 3 -minimum melting time t vmin 30 -maximum breaking time t vmax 20 10 5 -overload capacity characteristic 3 4 630 500 1 1h 30 20 315 400 4 5 1h I n [A] 10 5 4 2 10 1min 40 2 2 3 1min 5 40 20 10 5 1 20 10 10 6 4 5 1 10 6 4 1 2 10 5 10 5 10 5 10 0 1s 10 2 0 1s 5 -1 100 t v [s] t v [s] 10 5 2 10 -1 100 5 -2 10 10 -2 10 5 -3 1ms 10 -3 1ms 5 -4 10 2 10 3 5 5 10 4 10 10 5 5 -4 10 0 10 1 5 5 I p [A] 10 2 I2t characteristic PN000 ÷ 3 aM Cut-off characteristic PN000 ÷ 3 aM ~ 500 V ~ 500 V cosϕ = 0.1-0.3 10 10 3 5 x In cosϕ = 0.1-0.3 6 10 7 In [A] 5 5 630 500 400 5 630 5 315 160 10 10 6 In [A] 80 4 40 20 5 I c [A] 10 500 250 125 5 50 32 25 16 12 8 10 5 80 63 5 50 40 6 32 3 10 5 10 200 160 125 100 100 63 4 10 315 250 400 200 I2 t total [A2 s] 10 25 20 16 12 10 4 5 8 2 10 3 5 6 5 4 10 1 10 2 5 10 3 5 10 Ip [A] D10 4 5 10 5 5 10 6 10 2 2 10 5 3 10 5 4 10 Ip [A] 5 5 10 5 6 10
© Copyright 2026 Paperzz