Sequence of Operation Test Form Insert logo here SEQUENCE OF OPERATION TEST FORM Building Information Building name: Building address: Owner’s name: Owner’s address: Owner’s phone/fax/e-mail: Installing Contractor Company name: Address: Contact person: Phone/fax/e-mail: System Input System Output 1. A. Actuate common alarm signal indicator B. Actuate audible alarm signal G. Display and print change of status and time of initiating event H. Transmit alarm to FD and central station masterbox J. Actuate associated exterior fire alarm beacons K. Actuate all evacuation signals for the building L. Release all magnetically held doors A. Actuate common alarm signal indicator B. Actuate audible alarm signal G. Display and print change of status and time of initiating event H. Transmit alarm to FD and central station masterbox J. Actuate associated exterior fire alarm beacons K. Actuate all evacuation signals for the building L. Release all magnetically held doors M. Recall associated elevator in accordance with recall sequence P. Elevator hoistway open A. Actuate common alarm signal indicator B. Actuate audible alarm signal G. Display and print change of status and time of initiating event H. Transmit alarm to FD and central station masterbox I. Illuminate associated detector LED indicator 2. 3. Typical manual pull station (by device) floors 1–5 Typical elevator recall smoke detector (by device) by floor (lobby) Elevator machine room smoke detector For individual use. No other reproduction or transmission in any form permitted. Test Results Date Initials 1 of 4 Sequence of Operation Test Form System Input System Output 3. J. Actuate associated exterior fire alarm beacons K. Actuate all evacuation signals for the building L. Release all magnetically held doors P. Elevator hoistway open A. Actuate common alarm signal indicator B. Actuate audible alarm signal G. Display and print change of status and time of initiating event H. Transmit alarm to FD and central station masterbox J. Actuate associated exterior fire alarm beacons K. Actuate all evacuation signals for the building L. Release all magnetically held doors M. Recall associated elevator in accordance with recall sequence A. Actuate common alarm signal indicator B. Actuate audible alarm signal F. Actuate audible trouble signal G. Display and print change of status and time of initiating event H. Transmit alarm to FD and central station masterbox J. Actuate associated exterior fire alarm beacons K. Actuate all evacuation signals for the building L. Release all magnetically held doors Typical wet sprinkler system flow control valve assembly tamper switch — by floor C. Actuate common supervisory signal indicator D. Actuate audible supervisory signal G. Display and print change of status and time of initiating event Typical preaction sprinkler system flow control valve assembly flow switch — by floor A. Actuate common alarm signal indicator B. Actuate audible alarm signal F. Actuate audible trouble signal G. Display and print change of status and time of initiating event H. Transmit alarm to FD and central station masterbox K. Actuate all evacuation signals for the building L. Release all magnetically held doors C. Actuate common supervisory signal indicator D. Actuate audible supervisory signal G. Display and print change of status and time of initiating event 4. 5. 6. 7. 8. Elevator machine room smoke detector (continued) Typical smoke detector (by device) computer room (3rd floor) preaction system Typical wet sprinkler system flow control valve assembly flow switch — by floor Typical preaction sprinkler system flow control valve assembly tamper switch — by floor For individual use. No other reproduction or transmission in any form permitted. Test Results Date Initials 2 of 4 Sequence of Operation Test Form System Input System Output 9. A. Actuate common alarm signal indicator B. Actuate audible alarm signal G. Display and print change of status and time of initiating event H. Transmit alarm to FD and central station masterbox L. Release all magnetically held doors 10. 11. 12. 13. 14. 15. 16. 17. 18. Kitchen cafeteria wet chemical system — 1st floor P. Elevator hoistway open Typical duct smoke detector (by device) — by floor G. Display and print change of status and time of initiating event N. Shutdown associated mechanical equipment Fire pump running C. Actuate common supervisory signal indicator D. Actuate audible supervisory signal G. Display and print change of status and time of initiating event C. Actuate common supervisory signal indicator D. Actuate audible supervisory signal G. Display and print change of status and time of initiating event C. Actuate common supervisory signal indicator D. Actuate audible supervisory signal G. Display and print change of status and time of initiating event C. Actuate common supervisory signal indicator D. Actuate audible supervisory signal G. Display and print change of status and time of initiating event C. Actuate common supervisory signal indicator D. Actuate audible supervisory signal G. Display and print change of status and time of initiating event E. Actuate common trouble signal indicator F. Actuate audible trouble signal G. Display and print change of status and time of initiating event E. Actuate common trouble signal indicator F. Actuate audible trouble signal G. Display and print change of status and time of initiating event E. Actuate common trouble signal indicator F. Actuate audible trouble signal G. Display and print change of status and time of initiating event Fire pump power failure Fire pump phase reversal Fire pump connected to emergency power Fire pump circuit breaker at generator output Fire alarm system open circuit Fire alarm system ground fault Fire alarm system battery disconnect For individual use. No other reproduction or transmission in any form permitted. Test Results Date Initials 3 of 4 Sequence of Operation Test Form System Input System Output 19. E. Actuate common trouble signal indicator F. Actuate audible trouble signal G. Display and print change of status and time of initiating event E. Actuate common trouble signal indicator F. Actuate audible trouble signal G. Display and print change of status and time of initiating event E. Actuate common trouble signal indicator F. Actuate audible trouble signal G. Display and print change of status and time of initiating event E. Actuate common trouble signal indicator F. Actuate audible trouble signal 20. 21. 22. Fire alarm system low battery Fire alarm system ac power failure Fire alarm system amplifier failure Generator status indicator Test Results Date Initials Date system left in service: Test Witnessed by Owner/authorized agent Title Date Owner/authorized agent Title Date Additional explanations/notes: For individual use. No other reproduction or transmission in any form permitted. 4 of 4
© Copyright 2025 Paperzz