P1 and P1.A Series - ProMation Engineering

Data Sheet
P1 and P1.A Series
AdVanced Proportional Control
12v, 24v, 120v, 230v
ProMation Engineering developed the AdVanced
Proportional Controller specifically for applications
in Industrial Flow Control where repeatability and
ruggedness are key requirements. We designed the
board from the ground up using the latest surface mount
technology and a 16 bit microcontroller that provides
more functionality per square inch at a reduced price.
This AdVanced Controller
delivers high performance
and great value.
35% less than our
standard controller board
-- with more features.
••
••
••
••
••
SD14 P1P1A_all_VN4 Ver I_102214
AutoCalibration reduces setup time
Programmable Deadband
Self Tuning Feedback Signal
Diagnostic and Fault Indicators
Programmable Positioning on Loss
of Signal
•• Direct Acting or Reverse Acting
•• 4-20mA Input and Feedback signal
The P1 and P1.A series actuators with AdVanced Proportional
Control are ideally suited for multiple actuator OEM applications as
well as project work for flow control, heat transfer control, industrial
heating and cooling, chemical injection and process control.
Product Ordering Example:
Product Family
P1-
P1
P1.A
300”lbs/35Nm
445”lbs/50Nm
Voltage Options
Control Options
120
12
12VAC/DC610%
24
24VAC/DC610%
120
120VAC610%
230
230VAC610%
V
Special Designations
N
4 -
On/Off or V only
V
Advanced
Proportional
Page 1 of 4 P1 P1.A VN4 Series
N
Non-Spring
Return
4
NEMA
4X
AC
12 or 24VAC
DC
12 or 24VDC
XOV
No manual
override
(P1.A Only)
Note: Not all combinations are possible.
Please consult ProMation Engineering.
Product Specifications:
P1
Torque “lb/Nm
300”lbs/35Nm
Supply Voltage
12vac/vdc 24vac/vdc 120vac
Max Inrush Current
2.0A
1.1A
0.6
Running Current
1.9A
1.1A
0.6
Runtime (90° @ 60Hz/vdc)
15 sec
15 sec
12 sec
Runtime (90° @ 50Hz)
15 sec
15 sec
13 sec
230vac
0.4
0.3
12 sec
13 sec
P1.A
445”lbs/50Nm
Torque “lb/Nm
Supply Voltage
12vac/vdc 24vac/vdc
120vac
230vac
Max Inrush Current
1.5A
0.9A
0.6
0.4
Running Current
Runtime (90° @ 60Hz/vdc)
Runtime (90° @ 50Hz)
1.3A
20
20
0.8A
20
20
0.6
20
24
0.3
20
24
Common to both, (variations marked in yellow)
75%
1200 per hour
5lbs/2kg
7lbs/4kg | 6.6lbs/3kg
P1: ISO5211 F03/F05 8pt 14mm
P1.A ISO5211 F05/F07 8pt 17mm
Electrical Entry
P1-120VN4
(2) 1/2” NPT
Electrical Terminations
14-18ga
Environmental Rating
Manual Override: P1
Manual Override: P1.A
Control
Actuator Case material
NEMA 4/4X
8mm Socket Drive
5mm Hex Key (XOV has no override)
Proportional 4-20mA ONLY
Aluminum Alloy, Powder coated
DC Brush Type
230°F/110°C Thermal F* Class
Motor Protection
Typical Wiring Diagram for P1 and P1.A
Series with AdVanced Proportional Control
Refer to the proper IOM for your actuator for the
correct wiring diagram or visit www.promationei.com.
* CONNECTIONS
OPTIONAL
* Totally Enclosed Non-Ventilated Motors
Ambient Temperature
Operating Range
-22°F to +125°F
-30°C to +52°C
NOT OPEN*
12
OPEN COM*
11
OPEN*
10
NOT CLOSED*
9
CLOSED COM*
8
CLOSED*
7
MAX distance between Actuator
and Supply (feet)
4-20mA OUT +
Voltage
12vac/vdc
24vac/vdc
120vac
230vac
Actuator
Start Amps
P1
2.0A
P1
1.1A
P1
0.6A
P1
0.4A
18
41
150
1377
3960
16
65
236
2165
6223
(AC Hot or DC+)
14
105
381
3497
10052
(Neu or DC-)
P1.A
1.5A
P1.A
0.9A
P1.A
0.6A
P1.A
0.4
18
55
184
1377
3960
16
87
289
2165
6223
14
140
466
3497
10052
Actuator
Start Amps
AUXILIARY
SWITCH
SW4 (STANDARD)
SWITCH CARD
Wire Sizing Chart
Wire
Gage
SW3
AUXILIARY
SWITCH
(STANDARD)
24vac/24vdc/
120vac/230vac
12
4-20mA OUT -
11
4-20mA IN +
7
4-20mA IN -
6
5
4
H
HEATER
H
GND
GND Screw
M1
M2
M
THERMAL
SWITCH
DC DRIVE
MOTOR
FIELD WIRING
OTHERS)
Page 2 of 4 P1 P1.A VN4 Series
(BY
INTERNAL WIRING
(FACTORY)
SD14 P1P1A_all_VN4 Ver I_102214
Duty Cycle
Starts Per Hour
Weight: P1
Weight: P1.A | P1.A-XOV
Mechanical Connections
Mechanical Connections
2
2
Engineering Change Notice
REV Change Date
A
08.21.2013
B
04.15.2014
C
10.07.2014
E
F
Pushed square dimension to three decimal places
REV Change Date
A
08.21.2013
New Document
B
04.15.2014
B
Added tolerance on drive coupling
data04.15.2014
KHL
C
10.07.2014
Pushed square dimension to C
three decimal
places
10.07.2014
KHL
D
Added tolerance on drive coupling data
KHL
Notice
08.21.2013
New Document
KHL
04.15.2014
Added tolerance on drive coupling data
KHL
C
10.07.2014
D
E
Pushed square dimension to three decimal places
66 mm
57 mm
2.2 in
2.6 in
08.21.2013
New Document
KHL
Added tolerance on drive coupling data
KHL
KHL
Pushed square dimension to three decimal places
D
E
(Typical, some views rotated
for clarity)
F
F
B
A
P1.A Series Views
E
Name
Description
DescriptionName
Description
Date
REV Change
A
Dimensional Data
New Document
(Typical, some views
rotated for clarity)
Engineering
Change
D
REV Change Date
Name
Description
2
P1 Series Views
1
1
Engineering Change Notice
Engineering Chang
2
127 mm
5.0 in
KHL
127 mm
5.0 in
F
66 mm
2.6 in
57 mm
2.2 in
114 mm
4.5 in
1
B
57 mm
2.2 in
2
2
Engineering Change Notice
A
B
114 mm
4.5 in
REV Change Date
A
08.21.2013
B
04.15.2014
C
10.07.2014
D
A
SD14 P1P1A_all_VN4 Ver I_102214
35 mm
1.4 in
5 mm
0.2 in
Hex Key
0
C
1
F
70 mm
2.8 in
2.2 in
(2) 1/2" NPT
EMT Entry
[4.5"] to allow
for cover
removal
0
B
E
70 mm
57 mm 2.8 in
66 mm
2.6 in
Add 115mm
183 mm
[4.5"] to allow
7.2 in
for cover
removal
Add
115mm
(2) 1/2" NPT
EMT Entry
114 mm
4.5 in
A
B
229 mm
9.0 in
Add 115mm
[4.5"] to allow
for cover
removal.
106 mm
4.2 in A
Detail A-A
8 mm
14.00 mm 0.3
(2)in1/2" NPT
0.551 in EMT Entry
Square
8mm
50 mm
102
102(0.2
mmin)
A
14.00 mm
0.3mm
in
5mm
2.0
in
4.0
in
0.551 in 4.0 in
Hex
Key
Override
BHC
Square
50 mm
Drive Coupling (4)
Fabrication
Data
Coupling Fabrication Data
M6x1Drive
2.0 in
50 mm
10mm
BHC
+.00Bmm
2.0
in +.00 mm
17.00
0.4" 17.00 - .13
- .13 5 mm
BHC
0.2 in
(4) M6x1 +0.000
+0.000
0.669 - 0.005 in
0.669 - 0.005
HexinKey
10mm
B
0.4"
8 mm
(4) M6x1
0.3 in
(2) 1/2” NPT
EMT Entry
A
KHL
Pushed square dimension to three decimal places
66
2.6
REV Ch
F
183 mm
7.2 in
5 mm
0.2 in
Hex Key
Added tolerance on drive coupling data
KHL
D
106 mm
4.2 in
(2) 1/2" NPT
EMT Entry
KHL
E
106 mm
4.2 in
(2) 1/2" NPT
EMT Entry
66 mm
2.6 in
Name
Description
New Document
57
2.2
(2) 1/2" NPT
EMT Entry
183 mm
7.2 in
35 mm 36 mm
17.00 mm
17.00 mm
Add 115mm 0.669 in
1.4 in 1.4 in
0.669 in
mm
[4.5"] to allow
BHC
Square
Square
for cover
a00 in
36 mm
removal
(4) M5x0.8
05
70 mm
50 mm
1.4 in
00 mm
8mm
BHC
13
2.8 in
2.0 in
0.3"
000
BHC
BHC
in
(4) M5x0.8
005
8mm
(4) M8x1.25
A
A
+.00 mm
0.3"
.13
12mm
(4) M6x1
+0.000
F03/F05 ISO Flange
in
0.5"
0.005
10mm
10mm
8
mm
+.00
79 mm
35 mm
0 - .13 mm
+.00 mm
14.00
mm 0.3 in 0.4"102 mm
+
.00
8
mm
0.4"
3.117.00
in
1.4
in mm 17.00
mm
mm
17.00
17.00 - .13
- .13
0.551 in
+0.000
0.3
in0.669
8mm
(0.3 in)
4.0 in
ISO Flange
0.669 in
in
1 - 0.005 in F03/F05
Dwg. Name
+
Square
+
0.000
0.000
P1 F05 8P14 DimData.idw Socket Drive Override
on Engineering,
0.669
in
0.669
in
F05/F07 ISO Flange F05/F07 I

50
mm
ut the written
- 0.005
Drive Coupling Fabrication Data
36 mm 0.005
bidden.
Rev.
Drive Coupling
P1 Proportional Dimensional Data
2.0 in Fabrication Data
or Damages.
1.4
in
50 mm
+.00
C
Drawn By
Part No.
Drawn14.00
By
Created:
Part No.
Created:
mm
Drive
Coupling
Fabrication Data BHC
- .13
+.00 mm
Dwg. Name
4/25/2013BHC
KHL P1 Dimensional
KHL
2.0 in
P14/25/2013
F05
8P14
DimData.idw
Mation Engineering,
17.00
Data
for
Proportional
Units
352-544-8436
- .13
ithout the written
Checked By
By +0.000
LastChecked
Checked:
BHC
Last Checked:
0.551
in
52-544-8439
forbidden.
Rev.
(4)
M6x1
Dwg.
Name
Dwg.
Name
(4)
M5x0.8
+
0.005
0.000
4/15/2014
P1A F07 8P17 DimData.idw
Sheet
P1AinF07 8P17 DimData.idw
KHL
P1 Proportional
Dimensional
Data4/15/2014
KHL
This Document
isNumber:
the property of2ProMation
Engineering,
This Document
is the property of ProMation Engineering,
NO SCALE
ty for Damages.
0.669 - 0.005
C
Inc. Distribution
of this 
document
written of this document without the written
Inc.the
Distribution
10mm
Finish
8mm without
Material
Finish
Material
B
Aconsent of the owner is Strictly forbidden.
2
consent of the owner is Strictly forbidden.
Rev.
P1 Dimensional Data for Proportional
Unitswill incur0.3"
P1.A
DataProportional
Dim Da
Failure to comply
a liability forFailure
Damages.
0.4"Proportional DimP1.A
to comply will incur a liability for Damages.
ne: 352-544-8436
C
(4)
M6x1
: 352-544-8439
Dimensional Tolerances (Unless Otherwise
Noted): Tolerances (Unless Otherwise Noted):
Dimensional
Sheet
Number:
2 Promation Engineering Inc.
2.5mm [X.XEngineering
± .1]
X ± Promation
NO SCALEX ± 2.5mm [X.X ± .1]
Inc.
Dimensional Data for P1.A
Proportional
Dimensional
DataActuators
for P1.A
Proportion
X.X ± .3mm [X.XX ± .01"]
X.X ± .3mm [X.XX ± .01"]
10mm
Phone:16138
352-544-8436
Phone: 352-544-8436
16138 Flight Path Drive
Flight Path Drive
2 ± .13mm
X.XX ± .13mm [X.XXX ± .005"]
X.XX
[X.XXX ± .005"]
Fax: 352-544-8439
Fax: 352-544-8439
+
+
Brooksville,
Fl 34604
.00
.00
Brooksville,
Fl
34604
15.00 mm
ALL TOLERANCE FEATURES IN mm
0.4" 2
ALL
TOLERANCE FEATURES
mm Number:
mm IN mm
17.00 mm
14.00
NO SCALE
NO SCALE 17.00 - .13Sheet
- .13
8 mm
0.591 in
0.669 in
+
+
0.000
0.000
2
1 0.669
0.3 in
2 Flange
1
F03/F05 ISO
0.551
- 0.005 in
- 0.005 in
Page 3 of 4 P1 P1.A VN4 Series
ProMation Engineering, Inc.
ProMation Engineering, Inc.
n By
Created:
ked By
Last Checked:
KHL
KHL
4/24/2013
4/15/2014
Part No.
This Document is the property of ProMation Engineering,
ProMation Engineering,
Inc.
ProMation Engineer
KHL
ProMation
Engineering, Inc.
Dwg. Name
Drawn By
Created:
Checked By
Last Checked:
4/25/2013
P1 F05 8P14 DimData.idw
Part No.
Pro
Dwg. Name
P Series Exploded View
(P1-120VN4 shown)
Position indicator viewport
Aluminum Casting
NEMA 4X Protection
The P1 and P1.A quarter turn
actuators are weatherproof (NEMA
4X, IP67) with operating temperature
from -22°F to 125°F (-30°C to 52°C).
Indoors or outdoors, the P1 and
P1.A series actuators are built to
operate in demanding conditions.
Easily distinguishable yellow/red position indicator
Proportional
Control Card
Spacer
Switch
Card
Anti-Condensation Heater
NEMA 4X Cover Seal
Easily accessible switch &
cam stacks
Aluminum Casting
NEMA 4X Protection
Application Notes:
1. These actuators are to be mounted ONLY between a
horizontal and upright position.
2. When installing conduit, use proper techniques for
entry into the actuator. Use drip loops to prevent
conduit condensate from entering the actuator.
3. Both NPT conduit ports MUST use proper equipment
to protect the NEMA 4x integrity of the housing.
4. The anti-condensate heater is to be used in ALL
applications.
5. Do not install or store the actuator outdoors or in
humid environments without power to the heater.
6. Use proper wire size to prevent actuator failure (see wire
sizing chart).
7. Do not parallel wire multiple actuators together
without utilizing isolation relays! If this is your
intention, please contact ProMation Engineering for a
multiple actuator parallel wiring diagram.
8. There are no mechanical stops on P1 or P1.A models.
9. Auxiliary switches are rated 3A @ 250vac MAX.
Terminals marked A-F are dry type Form C.
10. All terminals accept 14-18AWG solid/stranded wire.
ProMation Engineering follows a policy of continual product updates and enhancements. Our website is the
best place to obtain the latest product documentation, including the wiring diagrams for these controllers.
Visit us at www.promationei.com or use the code to link to the site.
16138 Flight Path Drive
Brooksville, FL 34604
Phone (352) 544-8436 Fax (352) 544-8439
email: [email protected]
Page 4 of 4 P1 P1.A VN4 Series
Use your smart phone barcode
scanner app here.
SD14 P1P1A_all_VN4 Ver I_102214
Heavy Duty
Drive Motor