SAUTER EY3600 PDS 92.653 EYS153 en Product Data Sheet EYS153: nova106, Function card for 0-I-II-III/0-I-II-III-IV-V-VI commands This card enables the commands for 0-I-II-III or 0-I-II-III-IV-V-VI and the appropriate feedback signal to be registered. The command levels I to III can be fed back either real via an input or simulated via the card internally. The feedback signal for 'local' is always real; '0' must be derived from the software. The command outputs are effected via relays (the contacts of which can be loaded at 42 V, 2 A). Potential-free contacts, optocoupler or transistors with open collector can be connected to the feed-back inputs. Application: for controlling actuators with up to six switching levels. Products Type Description Weight (kg) EYS153F001 Function card for commands 0,18 EYS153F101 Function card for commands, with LED 0,18 Technical data Electrical supply Power supply Max. current EYS153F001 EYS153F101 Power loss, max. Inputs / Outputs Number of inputs Type of outputs Contact rating Number of feedback inputs Type of feedback inputs Threshold Max. output current of the feedback inputs Max cable resistance of the feedback inputs from rack 130 mA 134 mA approx. 4,6 W 2× 0-I-II-III 1× 0-I-II-III-IV-V-VI Relay 42 V/2 A 8 potential-free contacts optocoupler transistor (open collector) 1 V/4 V Permitted ambient conditions Operating temperature Storage and transport temperature Humidity 0…45 °C –25…70 °C 10…90% rh no condensation Standards, guidelines and directives CE conformity as per EMC Directive 2004/108/EC EN 61000-6-1/EN 61000-6-2 EN 61000-6-3/EN 61000-6-4 Additional information Fitting instructions MV 505538 Wiring diagram A04511 1,5 mA 600 Engineering notes The six digital outputs have, in groups of three, a common terminal to which the control voltage is applied. If two functions are occupied, terminal 1 must be connected with terminal 8. The relay contacts can be loaded at 42 V, 2 A ~/=. There are 8 feedback inputs available, so all the switching levels of both configurations (0...III and 0...VI) can be fed back. Using the S1 block of switches, it is possible to choose the type of feedback for the appropriate switching level for each of the functions. Switch Block S1 Position 1 2…7 8 Off On 2 × 0-I-II-III real FB No function 0-I-II-III-IV-V-VI simulated FB No function The simulated feedback signal stems from the relay's switching signal, so provides no guarantee that the actuator's reaction is correct. The real feedback is effected via an external contact. At the feedback inputs, 24 V is put to the terminals when the contacts are open. When the contacts are closed, the input is fed to earth and a current of approx. 1 mA flows. On the EYS153F101 card, the LED is switched from the relaycontrol facility, so is equivalent to a simulated indication. www.sauter-controls.com 1/2 EYS153 Wiring diagram EYS 153 F101 Numéro AS-Nr SA DO 0-I-II-III ou / 0-I-II-III-IV-V-VI Kartenplatz: Card slot: EMPLACEMENT Emplacement carte: 1 2 3 4 5 6 7 8 S1 Schalter Off - feedback S1-1/S1 On: False Pos 1 F1: I-II-III-IV-V-V F1 MFA . . . Max. 42 V/ 2A Loc. 1 F2 LED's 3 AR I II 4 10 LED's S1-5/ On:On F1-ST. IV F1: I-II-III Off:F2: F2-ST. IV-V-VII S1-6/ On:unechte F1-ST.RM V Funktion Off:keine F2-ST. II S1-7/ On: F1-ST. VI Off: F2-ST. III S1-8/ On: NC Off: NC AR Loc. I(IV) II(V) III(VI) III 5 11 9 2 MFA . . . Off: True - feedback S1-2/ I Pos 2...7 On: F1-ST. echte RM Pos 8 keine Funktion Off: F1-ST. I S1-3/ On: F1-ST. II Off: F1-ST. II S1-4/ On: F1-ST. III Off: F1-ST. III On Off 7 13 6 12 8 16 15 14 Ls I I II < 42 V II III III A04511b MM Wiring detail S1 Pos 1 S1-1 S1-1 Off On F1 I F1 II F1 III F2 I F2 II F2 III F1 I F1 II F1 III F1 IV F1 V F1 VI EYS 153 F101 • • • • • • © Fr. Sauter AG Im Surinam 55 CH-4016 Basle Tel. +41 61 - 695 55 55 Fax +41 61 - 695 55 10 www.sauter-controls.com [email protected] 2/2 Printed in Switzerland B04512 7192653003 04 www.sauter-controls.com
© Copyright 2026 Paperzz