biosign steam-24 biological indicators bi bi

Biosign steam-24
Biological indicators
Biosign steam-24
Biological indicators
product specification
product specification
product
Designed for biological testing of 121ºC (250ºF) and 134ºC
(273ºF) prevacuum, gravity and flash steam sterilization cycles
with 24-hour readout.
product
Designed for biological testing of 121ºC (250ºF) and 134ºC
(273ºF) prevacuum, gravity and flash steam sterilization cycles
with 24-hour readout.
application
The Biosign Steam-24 Biological Indicator (BI) is a selfcontained BI containing ampuled growth medium and filter
paper with 104 Geobacillus stearothermophilus spores/carrier.
The Biosign Steam-24 utilizes the Biosign 55ºC
Steam Incubator.
application
The Biosign Steam-24 Biological Indicator (BI) is a selfcontained BI containing ampuled growth medium and filter
paper with 104 Geobacillus stearothermophilus spores/carrier.
The Biosign Steam-24 utilizes the Biosign 55ºC
Steam Incubator.
Place a Biosign Steam-24 BI in the sterilizer to be monitored.
Refer to the appropriate Association for the Advancement of
Medical Instrumentation (AAMI) guidelines for the proper use
of biological indicators in healthcare facilities. After processing
the Biosign Steam-24 BI, follow the instructions for use included
with your Biosign Steam-24 for activation and incubation.
A positive control should be run on each day that testing
is conducted.
The Biosign Steam-24 is also available as a Test Pack for
132ºC (270ºF) prevacuum cycles with an instant readout
integrator load card. The Biosign SSI Test Pack gives the user
instant reassurance based on a result from a steam integrator
card. The Biosign SSI Test Pack contains the Biosign
Steam-24 BI, giving assurance that the sterilizer operated at
proper sterilization parameters.
incuBate
Incubate 55ºC ± 3ºC for 24 hours.
results
Positive growth of the test strip (sterilization failure) is indicated
by media change from RED to YELLOW. Results in 24 hours.
eXpiration date
18 months from date of manufacture.
certification
A standards/certification card is provided with each order.
D value information is available upon request.
ordering information
description
Biosign Steam-24 Biological
Indicators, 50/box
catalog number
61301605426
Biosign Steam Incubator (55ºC),
21 wells and built-in vial crusher
61301600055
Spirit Filled Thermometer
for incubator
61301604335
recoVerY media
Self-contained, no transfer to media required.
Digital Thermometer
for incubator
61301606186
Bi includes
104 G. stearothermophilus ATCC 12980 or 7953
self-contained with media ampule.
Biosign SSI Test Pack
61301605372
storage
Store in a refrigerator or controlled room temperature ranging
from 2ºC-24ºC (36ºF-75ºF). Store away from excess heat,
moisture, sterilants, or chemical vapors.
Getinge USA, Inc.
1777 East Henrietta Road
Rochester, New York 14623-3133
U.S.A.
Phone: (800) 950-9912
Fax:
(800) 950-2570
[email protected]
www.getingeusa.com
© 2009 Getinge USA, Inc. Getinge
is a registered trademark. • Printed
in the U.S.A.
SSBioStm24 1209
Includes:
20 Biosign SSI Test Packs
with Instant Read Integrator,
Record Card, 20 Controls
Place a Biosign Steam-24 BI in the sterilizer to be monitored.
Refer to the appropriate Association for the Advancement of
Medical Instrumentation (AAMI) guidelines for the proper use
of biological indicators in healthcare facilities. After processing
the Biosign Steam-24 BI, follow the instructions for use included
with your Biosign Steam-24 for activation and incubation.
A positive control should be run on each day that testing
is conducted.
The Biosign Steam-24 is also available as a Test Pack for
132ºC (270ºF) prevacuum cycles with an instant readout
integrator load card. The Biosign SSI Test Pack gives the user
instant reassurance based on a result from a steam integrator
card. The Biosign SSI Test Pack contains the Biosign
Steam-24 BI, giving assurance that the sterilizer operated at
proper sterilization parameters.
incuBate
Incubate 55ºC ± 3ºC for 24 hours.
results
Positive growth of the test strip (sterilization failure) is indicated
by media change from RED to YELLOW. Results in 24 hours.
eXpiration date
18 months from date of manufacture.
certification
A standards/certification card is provided with each order.
D value information is available upon request.
ordering information
description
Biosign Steam-24 Biological
Indicators, 50/box
catalog number
61301605426
Biosign Steam Incubator (55ºC),
21 wells and built-in vial crusher
61301600055
Spirit Filled Thermometer
for incubator
61301604335
recoVerY media
Self-contained, no transfer to media required.
Digital Thermometer
for incubator
61301606186
Bi includes
104 G. stearothermophilus ATCC 12980 or 7953
self-contained with media ampule.
Biosign SSI Test Pack
61301605372
storage
Store in a refrigerator or controlled room temperature ranging
from 2ºC-24ºC (36ºF-75ºF). Store away from excess heat,
moisture, sterilants, or chemical vapors.
Getinge USA, Inc.
1777 East Henrietta Road
Rochester, New York 14623-3133
U.S.A.
Phone: (800) 950-9912
Fax:
(800) 950-2570
[email protected]
www.getingeusa.com
© 2009 Getinge USA, Inc. Getinge
is a registered trademark. • Printed
in the U.S.A.
SSBioStm24 1209
Includes:
20 Biosign SSI Test Packs
with Instant Read Integrator,
Record Card, 20 Controls