ATF Cavity-BPM Analysis NanoBPM Project Third Mini-Workshop on Nano Project at ATF May 30-31, 2004 Toyoko Orimoto LBNL & UC Berkeley SLAC & KEK BPMs at ATF Two BPM experiments at ATF ATF BPMs 5/31/05 SLAC-BINP BPMs ATF BPM – Toyoko Orimoto ~ 6 meters 2 Introduction • • • • • • During March trip… connected ATF BPMs to SLAC generation 1 electronics Signal smaller than expected Short decay time Lower freq oscillation on top of usual ~20MHz Attempted calibration of KEK BPMs during March trip On this trip… waveforms from the BPMs look much better Another attempted calibration 5/31/05 ATF BPM – Toyoko Orimoto 3 Raw Waveforms from ATF BPMs 18 March ‘05 calibration run Trigger x1 y1 ~2 MHz ~24 MHz Ref SLAC x1 (for comparison) 5/31/05 x2 y2 x3 y3 ATF BPM – Toyoko Orimoto 4 Corrector Bump Calibration: Amp vs Event X 0→-875mm Dataset X2 X3 Amplitude X1 event X 0→+875mm Dataset X2 X3 Amplitude X1 5/31/05 ATF BPM – Toyoko Orimoto 5 event Waveforms BPM X1: X 0→-875mm 0 -125 -250 -375 -500 -625 -750 -875 5/31/05 0mm -125mm -250mm -375mm -500mm -625mm -750mm -875mm ATF BPM – Toyoko Orimoto 6 Amplitude: Cross-coupling (I) Y3 Amp Y1 Amp Y2 Amp X 0→-875mm Dataset X2 Amp X1 Amp X3 Amp 5/31/05 X1 Amp Y3 Amp Y1 Amp Y2 Amp X 0→+875mm Dataset ATF BPM – Toyoko Orimoto X2 Amp X3 Amp 7 Amplitude: Cross-coupling (I) Y3 Amp Y1 Amp Y2 Amp Y 0→-875mm Dataset X2 Amp X1 Amp X3 Amp Y3 Amp Y2 Amp Y1 Amp Y 0→+875mm Dataset 5/31/05 X1 Amp ATF BPM – Toyoko Orimoto X2 Amp X3 Amp 8 Waveforms from May 24 May ‘05 run Ref 5/31/05 X2 Y1 Y3 Y2 X3 ATF BPM – Toyoko Orimoto 9 Corrector Calibration • • • Bump beam in 50mm steps using corrector magnets Used correctors upstream of SLAC-BINP BPMs Quads off – from QD6X downstream Beam orbit vs extraction line BPM # 5/31/05 BINP ATF BPM – Toyoko Orimoto ATF 10 Corrector Calibration Amplitude Response in BINP BPMs is what we expected… BINP Y1 5/31/05 BINP Y2 ATF BPM – Toyoko Orimoto BINP Y3 11 event Corrector Calibration Amplitude X -700mm →+700mm Ref X2: Broken channel X3 Amplitude event Y1 5/31/05 Y2 ATF BPM – Toyoko Orimoto Y3 12 event Corrector Calibration Amplitude Y -700mm →+700mm Ref X2: Broken channel X3 Amplitude event Y1 5/31/05 Y2 ATF BPM – Toyoko Orimoto Y3 13 event Conclusions • • • Continue studying these BPMs Three shifts this week • Repair X2 broken channel ? • Steer beam through ATF BPMs • Perform proper calibration What changed between March and May data? 5/31/05 ATF BPM – Toyoko Orimoto 14 Corrector Bump Calibration: Amp vs Event Y 0→-875mm Dataset Y2 Y3 Amplitude Y1 event Y 0→+875mm Dataset Y2 Y3 Amplitude Y1 5/31/05 ATF BPM – Toyoko Orimoto 15 event Calibration: Amp vs Beam Offset X 0→-875mm Dataset BPM X2 BPM X3 Amplitude BPM X1 X 0→+875mm Dataset BPM X2 BPM X3 Amplitude BPM X1 5/31/05 ATF BPM – Toyoko Orimoto 16 Calibration: Amp vs Beam Offset Y 0→-875mm Dataset BPM Y2 BPM Y3 Amplitude BPM Y1 Y 0→+875mm Dataset BPM Y2 BPM Y3 Amplitude BPM Y1 5/31/05 ATF BPM – Toyoko Orimoto 17 Amplitude: Res & Cross-coupling (II) X3 Amp X1 Amp Y2 Amp X2 Amp X2 Amp Y2 Amp X 0→-875mm Dataset Y1 Amp Y3 Amp X1 Amp 5/31/05 X3 ATF AmpBPM – Toyoko Orimoto Y1 Amp Y2 Amp Y2 Amp X2 Amp X2 Amp X 0→+875mm Dataset Y3 Amp 18
© Copyright 2026 Paperzz