Round Robin Test Results Nick Conquest Matthew Wills Nhi Dinh Research Engineer Electrical Lab Manger Electrical Engineering Student Assistant 316.243.6940 316.978.5776 Wichita State University [email protected] [email protected] [email protected] 1 Round Robin Test Results Participants • Cessna Aircraft Co. • National Institute for Aviation Research • Cobham Technical Services • Rockwell Collins • DLS Electronic Systems • Thermo Fisher • Elite Electronic Engineering, Inc. • DnB • EMC Partner • Boeing • Electronics Test Center • Environ Thank you to all labs that participated! 2 Data Set • 12 companies participated in the testing. • Data was gathered from 25 different generators. • Multiple companies use a separate generator to produce WFM-1 and WFM1/WFM2. • 13 generators were “Custom Built” (DIY) • 12 generators were off the shelf (OTS) 3 Generator Types 4 ID# Generator Type ID# Generator Type Generator 1 DIY Generator 14 DIY Generator 2 OTS 1 Generator 15 DIY? Generator 3 OTS 1 Generator 16 DIY? Generator 4 OTS 1 Generator 17 OTS1 Generator 5 OTS 2 Generator 18 OTS3 Generator 6 OTS 2 Generator 19 DIY Generator 7 OTS 1 Generator 20 DIY Generator 8 DIY Generator 21 DIY Generator 9 OTS 2 Generator 22 DIY Generator 10 DIY Generator 23 OTS1 Generator 11 DIY Generator 24 OTS3 Generator 12 DIY Generator 25 OTS2 Generator 13 DIY OTS – Commercial Off the Shelf DIY- Do it Yourself – Lab Built Test Article 5 6 7 8 9 10 11 12 13 Round Robin Test Summary • DC resistance data was consistent across all test boxes and test houses. • Data on unshielded cabling and power lines with reasonable amount of impedance was very consistent. Voltage levels or limits are always obtained along with a low current and small standard deviation in current/voltage data. • Data on shielded and hybrid bundles show a lot of variation depending on the generator used. • Standard deviation of current on shielded and hybrid bundles was above 100A. • Labs were instructed to run the test as they would a standard DO160 test. – Some labs reran the testing with a different generator when the test level could not be reached, others did not. – This may simply be a “communication” error from the Working Group to the participants. 14 Round Robin Test Summary Continued • DIY generators typically showed variations • OTS generators of the same manufacturer typically gave similar results (likely due to similar generator source impedance) • Source impedance shown to be a determining factor on current/voltage measured on shielded and hybrid bundles. (Can be seen specifically in Generators 19-22, which are the same generator with different source impedance) 15 Plans for Next Round of Testing • What is an acceptable tolerance? • Determine generator source impedance during calibration? (i.e. Isc along with Voc at same generator output setting) – Will show variation between generator source impedances to help determine a tolerance between what is an acceptable test level. • Changes to Test boxes? Remove Shields? • Specific points of measurement? 16
© Copyright 2026 Paperzz