Asbestos Analysts Registry AAT Performance Results Report 1/24/2014 Organization ID: 101861 Nghiep Vi Ly NVL Laboratories, Inc. 4708 Aurora Avenue N. Seattle, WA 98103 Dear Nghiep Vi Ly, Please find your organization’s Asbestos Analysts Testing (AAT) results for Round 108. It is the organization’s responsibility to thoroughly review results and to immediately contact the AIHA Registry Programs, in writing, if any errors are found in your report or to request the removal of any analyst, who is no longer affiliated with the organization, from the Asbestos Analysts Registry program. Unacceptable performance may be improved by successfully analyzing a set of retest samples. Retest Order Forms are available on the website at: http://www.aiharegistries.org/programs/AAR/AAT. The deadline for ordering a retest for this round is <retestorder>. Retest sample kits are mailed via USPS Priority Mail one business day after the order deadline. Any enrolled analyst, who is unable to participate in an AAT round, must request an "Excused Absence" in order to not receive 4 outliers and an unacceptable performance rating. This written request must be received by the AIHA Registry Programs before the AAT round closes. Please note that an ”Excused Absence“ shall not be granted for consecutive rounds Please handle, store and analyze your organization’s AAT samples in the same manner as routine client samples. To submit your organization’s data, please visit the Data Entry Portal at: http://apps.aiha.org/pat/. Always save the confirmation page after submitting data via the Data Entry Portal; this is your proof of submission. Your organization’s password, needed to access reports on the Data Entry Portal, was provided in the upper right hand corner (next to your organization ID#) of the label on the results worksheet included with your AAT samples. The proficiency demonstrated by the results of this round of AAT is valid until the results of the retest round post, if the organization chooses to participate, or until the results of the next AAT round are available on April 24, 2014. The AAT Deadlines and Retest Order Form are available at: http://www.aiharegistries.org/programs/AAR/AAT The Asbestos Analysts Registry Policy is available at: http://www.aiharegistries.org/documents-policies-fees I encourage you to contact me with any feedback, questions or if you wish to contest the assessment of your performance at [email protected] or (703) 846-0798. Sincerely, Carter Dezio ® Program Specialist, AIHA Registry Programs AIHA Registry Programs ® 3141 Fairview Park Dr Ste 777, Falls Church, VA 22042 USA main +1 703-846-0755 web www.aiharegistries.org Asbestos Analysts Registry AAT Performance Results Report 1/24/2014 Organization ID: 101861 Nghiep Vi Ly NVL Laboratories, Inc. 4708 Aurora Avenue N. Seattle, WA 98103 REPORT OF PERFORMANCE FOR ROUND # 108, ORGANIZATION # 101861 The following individuals have met all the requirements* for Registration in the Asbestos Analysts Registry (AAR) and are listed as Registered Analysts: Outliers ID Name RESULTS (f/mm2) FOR THE CURRENT ROUND (R108) 7412 Ly, Nghiep (Nick) A1081 145 B1081 112 C1081 306 D1081 7476 Khan, Munaf A1081 137 B1081 103~ C1081 335 D1081 Performance R108 R107 TOT 137 0 0 0 Acceptable 122 1 0 1 Acceptable The following individuals have applied for Registration in the AAR, but have not met all the criteria* or they have lost their Registered Analysts status due to non-proficiency or non-participation.: Outliers ID Name RESULTS (f/mm2) FOR THE CURRENT ROUND (R108) R108 R107 TOT Performance The determination of outliers for the above results is based on the following performance limits: Reference Values for Round #108 Sample ID Batch Reference Mean Lower Limit Upper Limit A1081 1 238 117 403 B1081 1 224 109 379 C1081 1 312 153 527 D1081 1 190 93 321 *Criteria for listing as a Registered Analyst: 1. The organization’s application shall be reviewed and approved by an AAR Subject Matter Expert and must meet all the requirements of the current AAR Policy and NIOSH 7400 method. 2. An analyst’s application shall be reviewed and approved by an AIHA Registry Programs Staff Reviewer and must have completed two (2) consecutive AAT rounds with no greater than 2 outliers combined. Note, Registration letters are sent to newly Registered Analysts within 10 business days from the date the results of the AAT round in which the analyst gains proficiency are posted. Legend: “--” denotes that the analyst did not submit data (resulting in 4 outliers). “~” denotes that a sample ID or sample result was not within acceptable range. Asbestos Analysts Testing Program Organization ID: 101861 AAT Round 108 Page 2 of 3 Asbestos Analysts Registry AAT Performance Results Report “X“ denotes that the analyst was not enrolled in the specified round at the time of testing. “E“ denotes an approved excused absence. Asbestos Analysts Testing Program Organization ID: 101861 AAT Round 108 Page 3 of 3
© Copyright 2026 Paperzz