1 SWR (Single Wall Round) – Spiral Duct METU-STREIMER spiral duct is built for the most stringent applications! Standard offerings can be made to meet or exceed SMACNA standards for ±10” wg!* METU-STREIMER spiral duct is made to SMACNA lock seam standard RL-1. METU-STREIMER spiral is constructed from narrow 5.394” – 5.906” wide strip, creating a consistent lock seam that is both pleasing to the eye and inherently rigid. The METU-STREIMER lock seam has a leakage rate less than that allowed by leakage class “3”, and fully complies with seal class “A”, making it an ideal choice to lower energy use by ensuring that conditioned air reaches its intended destination. “METU-STREIMER certifies that the Spiral Duct shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511, and comply with the requirements of the AMCA Certified Ratings Program.” See data on last page. METU-STREIMER spiral duct is available in the following material grades: • • • • • • Galvanized steel, lock forming quality, conforming to ASTM standards A653 and A924. 304L-2B & 316L-2B stainless steel, conforming to ASTM-A240. Aluminum T-3003, conforming to ASTM-B209. Paint Grip. PolyVinyl coated. Perforated. * - Stock pipe will be built to +10” wg / -2” wg as listed in “SMACNA HVAC Duct Construction Standards, Metal & Flexible 3rd Edition – 2005”, Table 3-10. METU-STREIMER Catalog, SWR – Spiral Duct, January 2011 – Rev. 08a 2 Spiral Duct – Ordering Details METU-STREIMER STANDARD SPIRAL DUCT SPECIFICATIONS * Catalog # D1002-001 D1002-002 D1002-003 D1002-004 D1002-005 D1002-006 D1002-007 D1002-008 D1002-009 D1002-010 D1002-011 D1002-012 D1002-013 D1002-014 D1002-015 D1002-016 D1002-017 D1002-018 D1002-019 D1002-020 D1002-021 D1002-022 D1002-023 D1002-024 D1002-025 D1002-026 D1002-027 D1002-028 D1002-029 D1002-030 D1002-031 D1002-032 D1002-033 D1002-034 D1002-035 D1002-036 D1002-037 D1002-038 Description SWR, Spiral Duct, 3" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 4" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 5" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 6" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 7" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 8" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 9" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 10" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 11" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 12" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 13" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 14" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 15" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 16" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 17" Ø x 24GA Galv, 120" Long SWR, Spiral Duct, 18" Ø x 24GA Galv, 120" Long SWR, Spiral Duct, 19" Ø x 24GA Galv, 120" Long SWR, Spiral Duct, 20" Ø x 24GA Galv, 120" Long SWR, Spiral Duct, 22" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 24" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 26" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 28" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 30" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 32" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 34" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 36" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 38" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 40" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 42" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 44" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 46" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 48" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 50" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 52" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 54" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 56" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 58" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 60" Ø x 20GA Galv, 120" Long (D) (L) Units Diameter (in.)† Length (ft.)§ Each 3 10 Each 4 10 Each 5 10 Each 6 10 Each 7 10 Each 8 10 Each 9 10 Each 10 10 Each 11 10 Each 12 10 Each 13 10 Each 14 10 Each 15 10 Each 16 10 Each 17 10 Each 18 10 Each 19 10 Each 20 10 Each 22 10 Each 24 10 Each 26 10 Each 28 10 Each 30 10 Each 32 10 Each 34 10 Each 36 10 Each 38 10 Each 40 10 Each 42 10 Each 44 10 Each 46 10 Each 48 10 Each 50 10 Each 52 10 Each 54 10 Each 56 10 Each 58 10 Each 60 10 (G) Reinforcement Class Gauge -2" wg 26 NR 26 NR 26 NR 26 NR 26 NR 26 NR 26 NR 26 NR 26 NR 26 NR 26 NR 26 NR 26 NR 26 NR 24 NR 24 NR 24 NR 24 NR 22 NR 22 NR 22 ** A 22 ** A 22 ** A 22 ** A 22 ** A 22 ** A 22 ** A 22 ** C 22 ** C 20 ** C 20 ** C 20 ** C 20 ** C 20 ** C 20 ** C 20 ** C 20 ** C 20 ** C * - Standard Duct is made from G90 galvanized steel. † - Diameter = Outside Dimension § - 1' to 20' lengths available for an additional charge. \\ - Gauge listed is for +10" / -2" wg per SMACNA HVAC Duct Construction Standards, Metal & Flexible 3rd Edition – 2005”, Table 3-10. ** - Reinforcement required. Duct > 24" Ø will be supplied with MF (METU FLANGE) flanged ends for reinforcement. Note: Custom Lengths, gauges, & materials available upon request. For pricing and ordering information, contact your METU-STREIMER sales support team. METU-STREIMER Catalog, SWR – Spiral Duct, January 2011 – Rev. 08a 3 Spiral Duct Tolerances METU-STREIMER STANDARD SPIRAL DUCT TOLERANCE Description SWR, Spiral Duct, 3" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 4" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 5" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 6" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 7" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 8" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 9" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 10" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 11" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 12" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 13" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 14" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 15" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 16" Ø x 26GA Galv, 120" Long SWR, Spiral Duct, 17" Ø x 24GA Galv, 120" Long SWR, Spiral Duct, 18" Ø x 24GA Galv, 120" Long SWR, Spiral Duct, 19" Ø x 24GA Galv, 120" Long SWR, Spiral Duct, 20" Ø x 24GA Galv, 120" Long SWR, Spiral Duct, 22" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 24" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 26" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 28" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 30" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 32" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 34" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 36" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 38" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 40" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 42" Ø x 22GA Galv, 120" Long SWR, Spiral Duct, 44" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 46" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 48" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 50" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 52" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 54" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 56" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 58" Ø x 20GA Galv, 120" Long SWR, Spiral Duct, 60" Ø x 20GA Galv, 120" Long (D) Diameter (in.) 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 Length Weight (Lbs / Ft) ¶ Ø Tolerance ‡ Tolerance (in.) 2.967 ± 0.03 ± 1/4 0.8 3.967 ± 0.03 ± 1/4 1.1 4.967 ± 0.03 ± 1/4 1.4 5.967 ± 0.03 ± 1/4 1.6 6.967 ± 0.03 ± 1/4 1.9 7.967 ± 0.03 ± 1/4 2.2 8.967 ± 0.03 ± 1/4 2.5 9.967 ± 0.03 ± 1/4 2.7 10.967 ± 0.03 ± 1/4 3.0 11.967 ± 0.03 ± 1/4 3.3 12.967 ± 0.03 ± 1/4 3.6 13.967 ± 0.03 ± 1/4 3.8 14.967 ± 0.03 ± 1/4 4.1 15.967 ± 0.03 ± 1/4 4.4 16.955 ± 0.03 ± 1/2 5.9 17.955 ± 0.03 ± 1/2 6.3 18.955 ± 0.03 ± 1/2 6.6 19.955 ± 0.03 ± 1/2 7.0 21.95 ± 0.04 ± 1/2 9.3 23.95 ± 0.04 ± 1/2 10.2 25.95 ± 0.04 ± 1/2 11.0 27.938 ± 0.04 ± 1/2 11.8 29.938 ± 0.04 ± 1/2 12.7 31.938 ± 0.04 ± 1/2 13.5 33.916 ± 0.04 ± 3/4 14.4 35.916 ± 0.04 ± 3/4 15.2 37.916 ± 0.04 ± 3/4 16.1 39.916 ± 0.04 ± 3/4 16.9 41.916 ± 0.04 ± 3/4 17.8 43.898 ± 0.05 ±1 22.4 45.898 ± 0.05 ±1 23.4 47.898 ± 0.05 ±1 24.4 49.898 ± 0.05 ±1 25.4 51.898 ± 0.05 ±1 26.4 53.898 ± 0.05 ±1 27.5 55.898 ± 0.05 ±1 28.5 57.898 ± 0.05 ±1 29.5 59.898 ± 0.05 ±1 30.5 ‡ - Inner pipe dimensions. Tolerances may vary if non-standard material is selected. ¶ - Calculated weight, based on standard gauge G90 galv. ** - Reinforcement required. Duct > 24" Ø will be supplied with MF (METU FLANGE) flanged ends for reinforcement. METU-STREIMER Catalog, SWR – Spiral Duct, January 2011 – Rev. 08a (G) Gauge 26 26 26 26 26 26 26 26 26 26 26 26 26 26 24 24 24 24 22 22 22 ** 22 ** 22 ** 22 ** 22 ** 22 ** 22 ** 22 ** 22 ** 20 ** 20 ** 20 ** 20 ** 20 ** 20 ** 20 ** 20 ** 20 ** 4 AMCA Licensed Ratings and Leakage Test Results Duct Gauge 26 24 22 20 18 16 14 Test Pressure Inch/wg 15 15 15 15 15 15 15 * Leakage Rate at test pressure 0.003 0.010 0.022 0.022 0.014 0.006 0.004 * - Leakage rate measured as CFM per 100 ft2 of duct surface area. Listed measurements have been converted from CFM to SCFM. Standard cubic feet per minute (SCFM) is the volumetric flow rate of a gas corrected to standardized conditions of temperature, pressure and relative humidity. Tests are based on 24"Ø x 10' long spiral duct samples. Maximum allowable leakage of a duct system per SMACNA Class 3 at 10 wg is 13.4 SCFM. Air leakage is based on operation between 50° F to 104° F. IMPORTANT! METU-STREIMER spiral duct can be used with our revolutionary MF Flange connecting system! METU-STREIMER Catalog, SWR – Spiral Duct, January 2011 – Rev. 08a
© Copyright 2026 Paperzz