P15662: Linearly Reciprocating Friction Tester Armature Subsystem: Reba Conway, Kolby Irving, Chris Karamanos, Eric Kutil, Emeka Okoye Base Subsystem: Sean Cummings, Ethan Hanson, Matt Lebowitz, Tyler Nigolian, Alexandra Woodward Agenda Project Overview Constraints Engineering Requirements Customer Requirements Project Overview Constraints Constraint Was it met? Customer Requirements Customer Importance Description Reqt # Requirement Met? C1 9 Interface between Armature (P15660) and Reciprocating Base (P15661) C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 3 3 3 1 User and repair manual included System is safe to be around when running All data in SI units Physical size fits on desktop Ease of use Accommodate ball/pin contact holder Contact Holder to be removable and interchangeable Range of normal force applied to contact Zero resting force of armature (load release) Continuous force by voice coil Base does not deform under applied normal load Base accepts variable sized specimen Device will accommodate both dry and lubricated specimen tests Variable stroke Variable frequency Test rig must remain stationary during operation Data acquisition system integrates with LabVIEW Contact Holder to be easily adjustable Device reliable for long test durations Variety of precision weights meets requirement meets minimum requirement does not meet requirement Engineering Requirements (System) Eng Reqt # Source Engineering Requirement (metric) ER1 C1 ER2 ER3 ER4 ER5 ER6 ER7 ER8 ER9 ER10 ER11 ER12 ER13 C3 C3 C5 C20 C6 C9, C12 C10 C13 C13 C11 C15 C16 ER14 C7 Actual PASS/FAIL PASS PASS System Safety Fail Safe System not too large Test duration Base is easy to clean Testing load range Zero Resting Force of Armature Specimen diameter Specimen thickness Minimize weight of holder Stroke Frequency PASS/FAIL PASS/FAIL feet hours seconds N N mm mm kg mm Hz PASS PASS 4x6 0.1-10 60 0.01 0.5 - PASS PASS 2x1 24 45 0.5-20 0 20-50 5-25 0.25 2-10 +/- 0.5 1-10 +/- 0.5 46 PASS 0.0001962 19.41 - 53.27 PASS 0.285 PASS PASS N 30 >30 50.56 mm 30 >30 47.22 Minutes 2 <2 0.67 mm mm PASS/FAIL PASS/FAIL 35 35 PASS PASS >>35 >>35 PASS PASS 27 49 Secure Ball/Pin Holder and Resist Slippage C1, C6, C19 Adjustablity in the Z-axis ER16 C6, C8, C19 Ball/Pin Easily Adjustable and Interchangeable C1, C6 C1, C6 C4, C18 C18 Marginal Ideal Value Value Base and armature use the same interface ER15 ER17 ER18 ER19 ER20 Units Adjustablity in the X-axis Adjustablity in the Y-axis Record Frictional Force Data Acquisition works with LabView meets requirement meets minimum requirement does not meet requirement PASS 2x1.04x1.05 Project Deliverables Completed reciprocating friction tester Complete documentation package Drawings Process sheets Test plans Test data validating conformance to requirements Maintenance and operation manual Final Product – need to label other major parts, label x + y axis counterbalance strain gauges voice coil Final Product - need to label major parts, label x + y axis Test Results Project Status Major Issues
© Copyright 2026 Paperzz