Bid Set - Royal Seal Companies

2/17/2017
11:
29:
36 AM
GAS WATER HEATER SCHEDULE
SCOPE
THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A
COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM. THE PLUMBING
TEMP.
G.P.M.
HEATER
HEATER
HEATER
RISE
FLOW
DEPTH
WIDTH
HEIGHT
199,000 B.T.U.
90°
9.8
10"
18.3"
26"
RINNAI
RUC98i/WRIK INSTALL KIT
199,000 B.T.U.
90°
9.8
10"
18.3"
26"
RINNAI
RUC98i/WRIK INSTALL KIT
DESIGNATION
INPUT
WH-1
WH-2
MANUFACTURER
ESIGN
MODEL NUMBER
CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT
a n d
NECESSARY TO COMPLETE THE PLUMBING WORK.
SITE EXAMINATION
THE PLUMBING CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE
NGINEERING
PLUMBING LEGEND
FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND WILL REPORT ANY
CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE
SYMBOL
DESCRIPTION
ABBREVIATIONS
PLUMBING WORK.
ARCHITECTS
I NC
COLD WATER (UNDERGROUND)
STANDARDS
VACUUM RELIEF VALVE
EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF
1‚" GAS SUPPLY LINE
STRUCTURAL AND CIVIL ENGINEERS
COLD WATER
C.W.
HOT WATER (TEMPERATURE, IF MORE THAN ONE)
H.W.
CLEAN-OUT
C.O.
1645 Westgate Circle
Brentwood , Tennessee
37027
fax: 370-9108
615-370-1779
www.dandeinc.us
OR DIP TUBE CONNECTION
ASME, ASTM, UL, NEMA, ANSI, ASHRAE, NFPA, AS APPLICABLE TO EACH
G
INDIVIDUAL UNIT OR ASSEMBLY.
CHECK VALVE (TYP.) INSTALL
THERMOMETER
CODES
COORDINATE FLUE VENTING
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE
w/MECHANICAL PLANS AND
STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE
WH EQUIP. MANUFACTURERS
DRAWINGS/SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST
RECOMMENDATION
STANDARD SHALL APPLY. THE MECHANICAL CONTRACTOR SHALL SATISFY CODE
(TYP.)
C.O.
C.O.
IN HORIZONTAL POSITION
1‚" COLD WATER TO HEATER
SS
SANITARY SEWER (UNDERGROUND)
SS
SANITARY SEWER
S.S.
VENT
V
AMTROL ST-12
1‚"
REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST.
V
1‚" 140°HOT
THE PLUMBING CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES
WATER TO SYSTEM
V.T.R.
G
AND INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING WORK.
VENT THROUGH THE ROOF
V.T.R.
NATURAL GAS
G
TE
OF LOUI
SI
A
A
N
PERMITS AND FEES
ST
A
EXPANSION TANK
MITCHELL D. SIMPSON
H
C
ME
E
R
I
NG
Licence No. 32323
PROFESSIONAL ENGINEER
WARRANTY
CD
CONDENSATE DRAIN
C.D.
GREASE WASTE
G.W.
G
THE PLUMBING CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE
G/W
FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1)
A
IN
N
E
IC
N
AL ENG I
1‚"
YEAR FROM THE DATE OF FINAL ACCEPTANCE AND WILL REPAIR OR REPLACE ANY
2/17/17
RISER IDENTIFICATION
DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER
EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS
AND WORKMANSHIP.
WH-2
WH-1
140°
140°
P-1
FIXTURE IDENTIFICATION (SEE SPECIFICATIONS)
VALVES (SEE SPECIFICATIONS FOR TYPE)
GALVANIZED
NIPPLE (TYP.)
GAS VALVE (PLUG COCK)
DIELECT.
MECHANICAL GAS VALVE
UNION
1"
(TYP.)
REDUCED PRESSURE BACKFLOW PREVENTER
R.P.B.P.
P-2
LAVATORY (WALL-HUNG, PUBLIC)
AMERICAN STANDARD DECLYN #0321.026 LAVATORY WITH
WALL HANGER.
AMERICAN STANDARD #0114.116.002 S.L.F. WITH GRID
STRAINER.
17 GA. CAST BRASS CHROME PLATED P-TRAP WITH CHROME
PLATED BRASS STOP WITH BRAIDED SUPPLY.
PROVIDE TRAP AND SUPPLY INSULATION PROTECTION.
•
•
1‚
1‚
P-3
HAND SINK w/SIDE SPLASH PANELS
PROVIDED BY KEC. (ITEM #90).
•
•
1‚
1‚
---
---
---
• TO T.P.
---
---
---
---
---
AS SHOWN
AS SHOWN
---
---
AS SHOWN
AS SHOWN
STATE & LOCAL CODES. PIPING SHALL BE ARRANGED AS SHOWN TO INSURE BALANCED
FLOW THROUGH EACH HEATER.
FINISH FLOOR LINE
INSTANTANEOUS GAS WATER HEATER DETAIL
JANITOR SINK
FIAT MOP RECEPTOR MODEL SB3624 36"x 24"x 6" DEEP
w/3" DRAIN.
NONE
WALL MOUNTED FAUCET PROVIDED IN KITCHEN EQUIP.
PACKAGE.
3" VENT (MIN.)
P-5
WALL HYDRANT
WOODFORD 17 FREEZE RESISTANT WALL HYDRANT
w/V.B., WALL FLANGE AND TEE KEY HANDLE
P-6
TRAP PRIMER
P.P.P. PRIME RITE
P-7
FLOOR SINK
PLASTIC ODDITIES FBH400FN PVC BODY WITH
3
4
GRATE,
SQUARE TOP WITH DOME BOTTOM STRAINER.
P-8
INLET
3' MIN.
OUTLET
HEAVY DUTY TRAFFIC
FLOOR DRAIN
PLASTIC ODDITIES PHD8GOR (3") PVC BODY WITH 6" S.S.
FULL GRATE ROUND TOP WITH BASKET STRAINER.
NARROW TRENCH DRAIN - RESTROOMS
RATED CAST IRON
ZURN MODEL Z880-(2)E1-(1)U1.5-POG-48" (COLOR BY ARCH.)
MANHOLE FRAME AND
MODULAR 2-1/2" WIDE TRENCH DRAIN WITH HDPE DRAIN GRATE.
COVER 20" MINIMUM
GRATE COVER SAND OR GRAY TO MATCH ADJACENT FLOOR TILE.
OPENING (SQUARE OR
PROVIDE w/2" DEEP SEAL P-TRAP PRIMER CONNECTION
ROUND) GROUTE INTO
AS REQUIRED BY LOCAL CODE AUTHORITY.
PLACE. (TYP.)
FINISHED GRADE (REF.)
VENT
4" OPEN TOP
SAN. TEE (TYP.)
CONC.
TRENCH DRAIN - ICE MACHINE
OR BRICK
ZURN MODEL Z886-(2)E1-(1)U4-SVF-PS-36" MODULAR
RISER
4" MIN. PIPE
9" MIN. 2" MIN.
SIZE (TYP.)
12"
MIN.
2" MINIMUM
CHANNEL DRAIN, BODY OF HDPE w/END CAPS, 4"
4" PIPE MIN.
EQ.
12" MIN.
EQ.
15" MIN.
4" TO SAN.
OUTLET, STAINLESS STEEL GRATE & FRAME.
SEWER SYSTEM.
PROVIDE w/DEEP SEAL TRAP.
Job Number:
68-0129
Revisions:
2'-6" MIN.
6'-0" MAX.
3,000 GALLON PRE-CAST
CONC. SEPTIC TANK
4" SANITARY
ELBOW MIN.
PLUMBING FIXTURE SCHEDULE NOTES:
(DESIGNED FOR HEAVY
TRAFFIC LOADING)
5' MIN.
1. CONTRACTOR SHALL FURNISH AND INSTALL CARRIER FOR EACH FIXTURE WHICH IS WALL HUNG, UNLESS OTHERWISE NOTED.
3" MIN.
PROVIDE APPRORIATE CARRIER PER FIXTURE TYPE AND REQUIREMENTS.
2/3 OF CAPACITY
1/3 OF CAPICITY
MIN. (500 GAL. MIN.)
MAX. (250 GAL. MIN.)
2. CONTRACTOR SHALL FURNISH AND INSTALL WATTS, ZURN, P.P.P. INC., OR EQUAL TRAP PRIMERS TO SERVE ALL APPROPRIATE FLOOR DRAINS
AND/OR OPEN RECEPTACLES AS REQUIRED BY LOCAL CODES.
3. ACCEPTABLE ALTERNATE MANUFACTURERS FOR ITEMS INCLUDING BUT NOT LIMITED TO CLEANOUTS/FLOOR DRAINS/FLOOR SINKS/HUB DRAINS: ZURN,
GREASE TRAP DETAIL
SCALE:
NONE
JOSAM, WADE.
4. WRAP ALL SUPPLIES AND P-TRAPS OF BARRIER FREE LAVATORIES WITH A PROTECTIVE INSULATING MATERIAL AND A SMOOTH JACKET (TRAP-WRAP
OR EQUAL).
NOTE:
IF NOT PROVIDED IN CIVIL DOCUMENTS
FEBRUARY 17, 2017
5. PLUMBING CONTRACTOR SHALL COORDINATE WITH ELEC. AND MECH. CONTRACTORS TO PROVIDE INFORMATION CONCERNING OPERATION OF WATER
HEATER FOR CONNECTION OF AUTOMATIC FLUE DAMPERS AND/OR MOTORIZED COMBUSTION AIR LOUVERS (WHEN REQUIRED).
COORD. LOCATION & CONFIRM WITH CIVIL PLANS.
6. SHOCK ARRESTORS FOR BRANCH PIPING TO FIXTURES WITH QUICK CLOSING VALVES SHALL BE BY P.P.P. INC, ZURN (OR EQUAL), SIZED PER
PDI REQUIREMENTS.
7. MAXIMUM FLOW RATES:
WATER CLOSETS: 1.28 GALLONS PER FLUSH
FAUCETS: 2.0 GALLONS PER MINUTE (SINKS AND LAVS)
FITTINGS SHALL BE MARKED AS SUCH AND CERTIFIED
8. PROVIDE WILKINS 1070 TEMPERING/MIXING VALVE AT EACH HAND WASH LAVATORY OR SINK.
P-3
PLUMBING
LEGENDS SCHEDULES
& DETAILS
CD-82E-17-SD-00
Bid Set
2
37211
4
N A SH V ILLE, TN
---
RIM HEIGHT, 1.28 G.P.F., ELONGATED BOWL, SIPHON JET,
FLUSH VALVE WATER CLOSET.
ZURN Z6000AV-HET, 1.28 GPF EXPOSED, MANUAL FLUSH VALVE.
CHURCH 9500 SSCT ELONGATED OPEN FRONT SEAT
w/SELF-SUSTAINING HINGE.
4. COORDINATE INSTALLATION WITH WATER HEATER MANUFACTURER'S RECOMMENDATIONS,
rsouthal
l
1
1
2"
3. PROVIDE CONTROLLER SYSTEM FOR MULTIPLE WATER HEATER UNIT CONTROL REU-EZC-1-US.
SCALE:
VENT (IN.)
AMERICAN STANDARD 2854.128 MADERA FLO-WISE, 16
2. SECURELY ANCHOR WATER HEATERS TO WALL PER MANUFACTURER'S RECOMMENDATIONS.
INCLUDE RECIRCULATING PUMP IN CONTROL SYSTEM.
WASTE (IN.)
SU ITE 3 0
WATER CLOSET (H'CAP.- FLR. MTD., F.V.)
H.W. (IN.)
6 2 4 G RA SSM ERE PA RK D RIV E,
P-1
C.W. (IN.)
FO R
STATE AND LOCAL CODES.
DESCRIPTION
LO C A TIO N
1. COORDINATE INSTALLATION WITH WATER HEATER MANUFACTURER'S RECOMMENDATIONS,
P-#
A N EW
NOTES:
A.F.F.
48"
CONNECTION DETAIL
RECOMMENDATION
SEE TYPICAL GAS
D 'S , LLC
FIXTURE CONNECTION SCHEDULE
GAS SUPPLY LINE
1‚" HEADER
C A P TA IN
DETAIL
H A M M O N D , LA
CONNECTION
(TYP.)
2 4 4 4 W ES T TH O M A S S TR EET,
SEE GAS
BALL VALVE
C A PTA IN
D 'S
DRIP LEG
8:
0 '
:
"/ i
n.
G:
\17021\P- 3.
dgn
GENERAL PLUMBING NOTES: