nt te ing Paend P MP-UI026 Rev.4, Sep. 2014 Extensive insertion path Maximum angulations for varying insertion path: User Manual Ball Anchor Angulated Abutment Recommended tightening moment 30 Ncm. (MB-AN152/MB-AN252) ^ The Ball anchor 15° angulated abutment allows a maximum 30° insertion path. ^ 30° ^ ^ ^ 50° ^ ^ The Ball anchor 25° angulated abutment allows a maximum 50° insertion path. ^ 15° 15° Recommended tightening moment 30 Ncm. ^ ^ ^ ^ 25° 25° MIS Implants Technologies Ltd. P.O.Box 7, Bar Lev Industrial Park, 2015600, ISRAEL Website: www.mis-implants.com Sterilization - The device is not sterile. - The device must be sterilized before use by autoclave, at a temperature of 134ºC (273ºF) during 6 minutes. Do not exceed 134ºC during sterilization. ® Key to codes used: Attention, see instructions for use Batch code EC Catalogue number Manufacturer 0483 REP MIS Implants Technologies GmbH Simeonscarre 2, 32423 Minden, Germany Tel: +49 571-972-7620 Email: [email protected] By prescription only © MIS Corporation. All rights Reserved. ® A definition of the product. Operating Procedure. The device is intended as an intra-oral abutment secured to implants onto which a multiple unit prosthetic restoration is screw-retained ■ Standard impression procedure ■ Standard restorative components ■ Low profile, allowing a wide spectrum of insertion possibilities for correction of up to 50° ■ Advanced solution for rehabilitation on implants in total edentulous patients ■ Use of supplemental standard MIS ball attachment system components. 3 The Ball anchor angulated abutment is now positioned in place and secured to the implant. 1 In cases where ball anchor angulated abutment is needed, select abutment according to the implant's angulations (15°/25°). The Ball Anchor Angulated abutment assembly components: Ball Ø2.25 Ø4.6 Abutment. MB-AN152 MB-AN152- Ball anchor 15° angulated abutment. 15° 3mm 1.7mm or Ø4 Ball Ø2.25 MB-AN252 MB-AN252- Ball anchor 25° angulated abutment. Characteristics .6 The Ball anchor angulated abutments are made of titanium Ti6Al4V ELI ■ The Ball anchor angulated abutment can be connected in one of 6 possible positions on the fixture head. 2 25° 3.5mm 1.7mm Place the Ball anchor angulated abutment (15°/25°) on the implant by the gripping bar. To screw the abutment to the implant, position the Hand Hex. Driver (MT-HHR13) through the gripping bar’s opening. Recommended tightening moment 30 Ncm. Gripping Bar. MM-PG250 The gripping bar indicates the direction when positioning the ball anchor angulated abutment and supports the abutment when screwed onto the implant. A. B. C.
© Copyright 2026 Paperzz