Infusion Pump J1060MN

Vet Pump
Volumetric Infusion Pump
What do Veterinarians want from an Infusion pump?
J1060MN
*Uses any standard IV set.
Store up to 20 brands in
memory
*NO DRIP DETECTOR
*Reliable and accurate
within -/+ 5%
*Affordable-New, not
refurbished
*Easy to read, bright
LCD screen
*Easy to navigate
menu options
*Lightweight and portable
*2 year limited warranty
Components and functions:
Alarm light
Handle for carrying
Bright LCD Display
Easy open pump
door handle
Keyboard for
data entry
Fluid path
*Runs on standard 110V AC, or battery.
Battery lasts over 4 hours when fully
charged.
Occlusion pressure
sensor, top
Peristaltic finger
pump
*Simple to navigate menu screen lets
you set infusion parameters, as well as
change speaker volume, occlusion
pressures, air sensitivity and calibrate
IV sets.
Air sensor
Occlusion pressure
sensor, bottom
Tube clamp
(inside of door)
Ease of use of the JorVet Infusion Pump:
Battery level indicator
In-progress flow
indicator
Remaining volume to be
infused
Remaining infusion time
Flow Rate
Chose between:
*ml/hr
*drips/min
*volume/time
infusion
Total volume infused
IV set brand and type
Exit Key: Return to
previous menu
Menu Key: To enter
the menu or return
to the main screen
Alarm silence key
Switch Key:
Moves cursor
Start/Stop Key
Set/Enter Key: To activate or
confirm settings
Clear Key: To clear
alarm or parameter
Power Key
Up/down keys: To
set parameters
and scroll through
menu
Prime key
Battery indicator light
AC Power indicator light
Specifications for the J1060MN:




No drip detector
Easy to navigate menu screens
Pumping mechanism: Peristaltic finger pump
Applicable IV set: 10, 15, 20 and 60 d/ml (with outer diameter 3.4 ~ 4.5mm)
Can program up to 20 different brands of IV sets.
 Flow rate setting range: 1.0 -1200 ml hr (can set in 0.1ml increments up to
100 ml)
 Infusion rate options: Set at ml/hr, drops/ minute or volume/time
 Flow rate accuracy: +/- 5% (after calibration)
 Volume limit: 1-9999 mls
 KVO: 1 ml
 Occlusion pressure: 40 ~ 140 KPa, 8 sensitivity setting
 Purge rate: 600 ml/hr
 Bolus mode
 Audio and visual alarms: Air-in-line, Door open, Upstream occlusion,
Downstream occlusion, Infusion finished, No operation, Bottom empty,
Battery low, Pump error, Motor reverse, AC power lost.
 Self check during start up and during infusion.
 Power source: AC100V ~ 240V, 50Hz/60Hz
 Internal battery: Rechargeable Ni-MH battery, DC12V, 2000mAh,
Approx. 4 hrs at 25ml/hr
 Display: Blue LCD with high brightness
 Dimensions: 6”w x 6”d x 9”h
 Weight: 5 lbs
 IV pole mount
 2 year limited warranty
 In house technical support
Jorgensen Laboratories, Inc.
1450 Van Buren Ave
Loveland, Colorado 80538
Telephone: (800) 525-5614
Fax: (970) 663-5042
www.jorvet.com
[email protected]