CMA-180UC 1 THRU 5 5-15-15 W-PN 1-12-17

180UC
Quick Setup
Instructions
WARNING: Electrical and
plumbing connections need
to be made by a qualified
service person who will
comply with all available
Federal, State and Local
Health, Electrical,
Plumbing and Safety
codes.
1
110V POWER
CONNECTION
FOR DISPENSER
RINSE
INJECTION
DRAIN HOSE
NEUTRAL
GROUND
HOT
DETERGENT
INJECTION
WASH
SENSOR
RINSE
SENSOR
HARD WIRE
FOUR WIRE
POWER SUPPLY
STEP
1
WALL
DRAIN
1"AIR GAP
3
DRAIN VALVE
4
PUMP DRAIN
MOTOR
2
LEVELING
LEGS
4
STEP
3
FLOOR DRAIN
Connect the drain hose to wall or floor drain. The
floor drain must have a 1 inch air gap between
drain hose and floor drain.
STEP
2
Level dishmachine by adjusting leveling legs.
Dishmachine must be level front and back.
CMA PN: 10130.02
1/2" WATER INLET
Connect dishmachine to hot water source, minimum
temperature 180°F will remain in wash cycle until
booster heater temperature reaches 180°F, then it
will advance into rinse cycle.
STEP
4
When ever possible, remove pump drain if a floor
drain is available near by. Remove drain pipe and
place drain hose on the drain valve and allow
machine to gravity drain.
1-2017
180UC
Quick Setup
Instructions
WARNING: Electrical and
plumbing connections need
to be made by a qualified
service person who will
comply with all available
Federal, State and Local
Health, Electrical, Plumbing
and Safety codes.
180UC FRONT VIEW
DISHMACHINES
POWER
WASH TEMP 150O-160O
FINAL RINSE TEMP 180O-195O
OFF
ON
DRAIN
FILL
START
CYCLE
ELECTRICAL
BLOCK
5
START
DRAIN FILL
WASH
TEMPERATURE
DISPLAY
RINSE
TEMPERATURE
DISPLAY
6
RINSE
PRESSURE
GAUGE
POWER
SCRAP
DRAWER
7
STEP
5
RINSE
BOOSTER
HIGH LIMIT
SWITCH
DETERGENT
THERMOSTAT
7
Chemical dispenser electrical hookup is located
inside control box. Chemical dispenser is optional.
It is not sold with dishmachine.
STEP
6
STEP
NOTE: To prevent Heating Element
damage, the 180UC heater must be
filled with water before the heating
element is energized. For this reason
the High Liimit Switch has
intentionally been disconnected at
the factory and will require
re-connection.
7
After filling dishwasher for the first time, (CAUTION:
turn power supply off) reconnect the factory
unplugged wire to booster high-limit switch located
behind front panel.
STEP
8
FILL
Turn power supply back on. Allow machine to heat
up (about 5 minutes). Cycle machine by pushing
start switch. Observe “Rinse Cycle” (last 12 seconds
of cycle) must be minimum 180°F. If necessary adjust
the temperature by turning the adjustment stem
clockwise to increase.
Turn on power and the machine will be automatically
filled to correct level.
CMA PN: 10130.02
8
an Ali Group Company
The Spirit of Excellence
1-2017