TNA170A00 TRI-BAND 1x790-960MHz, 2x 1710-2170MHz Panel Antenna External RET available Electrical specifications* R1 Frequency Range (MHz) 790-960 B1, B2 Polarization Gain (dBi) 1710-2170 ±45º 16,5 16,8 2—10 2—10 Horizontal Beamwidth (º), -3dB 65,2 56,9 Vertical Beamwidth (º), -3dB 8,0 7,0 Front to Back Ratio (dB) 180º±30º total power >25 >25 Cross Polar Discrimination (dB) Boresight >17 >23 Sidelobe suppresssion (dB) First sidelobe above horizon 17 17 Typ 18 Typ 20 Electrical Tilt (continuously adjustable) First null fill (dB) Impedance (W) VSWR Intraband isolation (dB) Interband isolation (dB) Intermodulation IM3 (dBc) Max power per input (W) External RET 50 < 1.5:1 B2 B1 > 30 > 30 < -150 300 R1 AISG 2.0 / 3GPP Protocol *All specifications are subject to change without notice. Refer to TELNET for the most current information. Mechanical specifications Input Position Dimensions (mm), H x Ø 6 x 7/16 female connectors Bottom, 6 (7/16) 2230 x 273 x 164 Weight (Kg) 20 Max wind speed (Km/h) 200 1 of 2 www.telnet-ri.es V150505 TNA170A00 Materials Radome Fiber glass + polyester End Caps Plastic of high resistance for the exterior Screws and nuts Stainless Steel Environmental and mechanical tests IEC 60068-2-1: Cold IEC 60068-2-32: Free Fall Test IEC 60068-2-2: Dry heat IEC 60068-2-56: Damp Heat Steady State IEC 60068-2-6: Sine Vibration IEC 60068-2-64: Random Vibration IEC 60068-2-14: Change of Temperature IEC 60529: IP Code Test IEC 60068-2-18: Water (Handheld shower) IEC 60695-2-1/2: Resistance to fire IEC 60068-2-27: Shock Test UNE-EN 60598-2-3: Resistance to wind IEC 60068-2-29: Bump Test Particular Specification: Resistance to ice IEC 60068-2-30: Damp Heat Cyclic 2 of 2 www.telnet-ri.es V150505
© Copyright 2026 Paperzz