LINCS100HN/XN Series

A0.1
Project
LINCS
Type
1” Modular Task Light
Low Voltage Halogen/Xenon
Project Location
LINCS100HN/XN Series
Catalog #
Description
The Little Inch Connecting System (LINCS) sets the standard for flexible,
inconspicuous undercabinet lighting. LINCS’ unique labor-saving plug-together
design affords premium quality at a low installed cost. The attractive extruded
aluminum design dissipates heat, is durable, lightweight and corrosion
resistant. LINCS is available with either halogen or xenon lamps to best suit
your application requirements. The wide variety of finishes and wiring options
make LINCS a great choice for both residential and commercial applications.
Additional features:
• Miniature 1” profile
• LINCS can be installed 4 times faster than conventional undercabinet
luminaires.
• Sandblasted glass lens minimizes lamp images on specular surfaces.
• Optional integral occupancy sensor automatically switches LINCS
on when the task area is occupied and off when vacant, helping to
maximize energy savings.
• Backed by a Lifetime Warranty.
Specifications
Construction .060” extruded aluminum housing with
injection molded polycarbonate endcaps and covers.
Reflector & Lens 5/32” tempered, sandblasted
glass lens to minimize lamp image on task surface.
Lens is secured to housing with two thumbscrews.
A white painted reflector is provided with black
finished models.
Finish LINCS is available in either a white or black
polyester powder-coat paint finish. In addition,
LINCS can be selected with a satin aluminum finish.
White painted models have matching white endcaps.
Black endcaps are provided with the black painted or
satin aluminum.
Lamps LINCS is supplied with halogen or xenon
lamps. Halogen lamps are 12v, 20W T3 lamps (G4 bipin base) with a 3000K color temperature and 2,000
hours rated life. A 10 watt lamp can be chosen as an
option or used as a future replacement lamp.
Xenon lamps are 12v, 18W T5 lamps (wedge
base) with a 2800K color temperature and 10,000
hours rated life. Xenon and halogen lamps are not
interchangeable.
Listings UL and CUL Listed for both direct-wired
and portable installations. The luminaire is also IBEW
labeled.
Electrical
Luminaires are supplied with an
electronic, high frequency 12v transformer. LINCS is
only available for 120 volt applications. Not available
for 277v or 347v installations. Optional passive
infrared occupancy sensor control (OSC) available.
Dimming
LINCS low voltage halogen/xenon
luminaires can be dimmed with a reverse phase
dimmer specifically designed for electronic low voltage
transformers.
Installation Male and female grounded Molex™
connectors are built into each end for modular,
plug-together electrical connection. LINCS can
also be connected with interconnect cords. A UL
recognized 3/8” flexible metal conduit/non-metallic
sheathed wiring connector is supplied with the
luminaire for direct-wiring into knockout in the back
of the housing or through adapter plate at the left
end. LINCS100HN18, 100XN18, 100HN27 and
100XN27 models have a wiring access panel with a
knockout to allow quick wiring of the first luminaire
without opening the wireway cover. For portable
installations, the power cord plugs directly into the
left end of the luminaire.
Warranty All luminaire components, except lamps
and transformers, are warranted against defects
during the life of the original installation (reference
Alkco’s Buying Guide for details).
Ordering Information
Sample Catalog No: LINCS100HN9-SGD - 120 - WHG - RSW
(Note: Separate multiple options with a comma.)
120
NOM.
LENGTH
Model Number
Voltage
LINCS100HN9-SGD (1) 20W T3 Halogen-G4 bi-pin base (12v)
9-7/8” LINCS100XN9-SGD (1) 18W T5 Xenon-Wedge base (12v)
LINCS100HN18-SGD (2) 20W T3 Halogen-G4 bi-pin base (12v)
18-7/8” LINCS100XN18-SGD (2) 18W T5 Xenon-Wedge base (12v)
120
Options
Finish
WHG White Glossy
MB Matte Black
SA Satin Aluminum
LINCS100HN27-SGD (3) 20W T3 Halogen-G4 bi-pin base (12v)
27-7/8” LINCS100XN27-SGD (3) 18W T5 Xenon-Wedge base (12v)
LINCS fixtures with CSJT-3 option can not be modularly connected.
To designate the cord color add a “W” for white or a “B” for black to the model number.
(Example: LINCS100ICSW)
3
OSC is not available with LINCS100HN9/XN9 models.
4
Switch controls individual fixture.
5
Specify voltage and finish for these options.
2
11500 Melrose Avenue Franklin Park, Illinois 60131 Phone: 847-451-0700 Toll-Free: 1-866-50ALKCO Fax: 847-451-7512 www.alkco.com 05/10
©2010 Alkco Lighting. All rights reserved. Product designs protected by copyright.
We reserve the right to change details of design, materials and finishes.
Alkco is a Philips group brand
Specify Qty. of Connectors Needed
1
QTY:
QTY:
QTY:
QTY:
QTY:
QTY:
QTY:
QTY:
QTY:
QTY:
10W CSJT-31,2 OSC3 RSW4
HLRSW4
SBF
LINCS100-15
LINCS100-1/RSW5
LINCS100-2/CO5
LINCS100PC32
LINCS100PC62 LINCS100PC102
LINCS100PCF42 LINCS100ICS2
LINCS100ICF2 LINCS100MSBRK
Note: Optional 10 watt halogen lamp
SJT cordset hard-wired into back of fixture. UL listed as a portable fixture for use in
office workstations
Integral occupancy sensor control
Rocker switch (on/off)
3-position rocker switch (high/low/off)
Slow blow fuse
Wiring module
Wiring module with rocker switch
Wiring module with duplex outlet
3’ Straight power cord
6’ Straight power cord
10’ Straight power cord
2’-4’ Flexible coiled power cord
6” Straight interconnect cord
12”-36” Flexible coiled interconnect cord
Mounting brackets for attachment to metal shelves (2 brackets)
Power cords plug into left end of the fixtures.
A0.1
Project
LINCS
Type
1” Modular Task Light
Low Voltage Halogen/Xenon
LINCS100HN/XN Series
Dimensional Data
LINCS100HN9-SGD
and LINCS100XN9-SGD
Halogen
1-3/16”
(30.16mm)
LINCS100-1
2-1/8”
1-7/8”
(53.97mm)
LINCS100-1/RSW
4-3/16”
4-3/16”
(106.36mm)
(106.36mm)
(47.63mm)
Left end
4-3/16”
5-1/4”
5-1/4”
(133.35mm)
(133.35mm)
(106.3mm)
4-15/16”
(125.41mm)
Xenon
4-15/16”
LINCS100-2/CO
(125.41mm)
9-7/8”
(250.83mm)
4-3/16”
1-3/16”
(30.16mm)
LINCS100HN18-SGD and LINCS100XN18-SGD
4-3/16”
(106.3mm)
(106.3mm)
7-1/4”
2-1/8”
1-7/8”
(184.2mm)
(53.97mm)
(47.63mm)
Left end
Installation Notes:
•
•
•
•
(1) End-plate supplied to allow direct wiring
into left end
When row mounting, allow 1” at end of a run
connection of last fixture
When using power cord, allow 3” at start of run
Subract 7/16” for each end-cover removed
in row mount applications.
9-7/16”
9-7/16”
(239.71mm)
(239.71mm)
18-7/8”
(479.42mm)
LINCS100HN27-SGD and LINCS100XN27-SGD
2-1/8”
1-7/8”
(53.97mm)
(47.63mm)
Left end
LINCS100HN27-SGD
13-15/16”
27-7/8”
Integral occupancy sensor control (OSC)
75˚
60
60˚
120
45˚
180
15˚
30˚
LEGEND:
0-deg:
90-deg:
180-deg:
Go to www.alkco.com for
additional Photometric Data
11500 Melrose Avenue Franklin Park, Illinois 60131 Phone: 847-451-0700 Toll-Free: 1-866-50ALKCO Fax: 847-451-7512 www.alkco.com 05/10
©2010 Alkco Lighting. All rights reserved. Product designs protected by copyright.
We reserve the right to change details of design, materials and finishes.
Alkco is a Philips group brand
(354.01mm)
(708.03mm)
90˚
0˚
13-15/16”
(354.01mm)
(3) 20W T3 Halogen G4 bi-pin base (12v)
320 lumens per lamp
Report No.: ITL55203
Efficiency: 49.4%
The OSC has a passive infrared occupancy (PIR) sensor
and a photocell for reading ambient light level. The
PIR sensor has a field-adjustable time delay that that
can be set for 30 sec., 10 min., 20 min., or 30 min. The
photocell allows a minimum ambient light alevel to
be set. If the ambient
illumination is above
this minimum level, the
luminaire will remain
off even if occupancy
is present. Connect
building power to
the LINCS luminaire
with the OSC. All
additional luminaires
interconnected to
that luminaire will
be controlled by
the single OSC.
ELECTRICAL DATA - Halogen
Model HN9
HN18
Lamp Wattage 20
40
Lamp Lumens 320
640
Input Watts 20
40
Max. Amps .17
.33
Power Factor >.93
>.93
HN27
60
960
60
.50
>.93
ELECTRICAL DATA - Xenon
Model XN9
XN18
Lamp Wattage 18
36
Lamp Lumens 264
528
Input Watts 20
40
Max. Amps .17
.33
Power Factor >.93
>.93
XN27
54
792
60
.50
>.93
Maximum of 6 total amps when row mounting
Maximum of 6 total amps when row mounting
A0.1
Project
LINCS
Type
1” Modular Task Light
Low Voltage Halogen/Xenon
LINCS100HN/XN Series
Photometric Data
LINCS100HN27-SGD
CO-EFFICIENTS OF UTILIZATION
(3) 20W T3 Halogen G4 bi-pin base (12v)
320 lumens per lamp
Report No.: ITL55203
Efficiency: 49.4%
rc
rw
90˚
75˚
60
60˚
120
45˚
180
0˚
15˚
30˚
LEGEND:
0-deg:
90-deg:
180-deg:
80
70 50 30 10
RCR 0
1
2
3
4
5
6
7
8
9
10
59
54
50
45
42
38
35
33
31
29
27
59
52
46
40
36
32
29
26
24
22
20
59
50
42
37
32
28
25
22
20
18
17
59
48
40
33
29
25
22
19
17
16
14
I
57
53
48
44
41
37
35
32
30
28
26
57
51
45
40
35
32
29
26
24
22
20
CANDLEPOWER DISTRIBUTION
Vertical
Angle
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
45°
177
177
173
164
150
125
88
53
29
13
5
90°
177
177
174
165
149
122
84
49
25
7
0
135°
177
177
175
167
149
114
71
39
17
0
0
57
49
42
36
31
28
25
22
20
18
17
57
47
39
33
28
25
22
19
17
15
14
180°
177
177
174
164
143
102
60
32
13
0
0
Zone
11500 Melrose Avenue Franklin Park, Illinois 60131 Phone: 847-451-0700 Toll-Free: 1-866-50ALKCO Fax: 847-451-7512 www.alkco.com 05/10
©2010 Alkco Lighting. All rights reserved. Product designs protected by copyright.
We reserve the right to change details of design, materials and finishes.
Alkco is a Philips group brand
55
49
43
38
34
31
28
25
23
21
20
55
47
40
35
31
27
24
22
20
18
16
55
46
38
33
28
24
21
19
17
15
14
30
50 30 10
53
47
41
37
33
30
27
25
23
21
19
53
46
39
34
30
27
24
21
19
18
16
Lumens % Lamp % Fixt.
0-30
142
14.8
30.0
0-40
235
24.4
49.5
0-60
396
41.2
83.5
0-90
473
49.3
99.9
90-120
1
0.1
0.1
90-130
1
0.1
0.1
90-150
1
0.1
0.1
90-180
1
0.1
0.1
474
49.4
100.0
0-180
Go to www.alkco.com for additional Photometric Data
50
50 30 10
ZONAL LUMEN SUMMARY
Horizontal Angle
0°
177
176
171
162
144
119
84
51
27
13
6
Effective floor cavity reflectance=20%
70
70 50 30 10
53
44
37
32
28
24
21
19
17
15
14
10
50 30 10
0
0
50
45
40
35
32
29
26
24
22
20
19
49
42
36
30
26
23
20
18
16
14
13
50
44
38
33
29
26
23
21
19
17
16
50
43
37
31
27
24
21
19
17
15
14